UREA FORMALDEHYDE FOAM INSULATION Much Ado About Nothing?

Similar documents
When Building a New Home

Sick Building Syndrome. By MaryJo Franciskovich. Every Product we use begins as a part of the earth, whether plant, mineral, or animal.

VOCs) For more information, see EPA's Substance Registry System on VOCs. Contents

INDOOR AIR QUALITY PROGRAM

Your Zero Energy Ready Home Story

Green Building Practice Summary 03/17/2011

According to our research and study most occupant complaints relating to IAQ are attributable to the following factors:

Indoor Air Pollution. Indoor air pollution can be an even greater health threat than outdoor air pollution. Common pollutants often

2/22/2008. Indoor Environmental (Air) Quality. Time Spent in Locations: Indoors & Outdoors. Why Should You Care About Indoor Air Quality?

VOLUSIA COUNTY HEALTH DEPARTMENT BUILDING DISASTER ASSESSMENT REPORT Pg 1 of 5

Keep It Pest and Contaminant Free

University of Rochester Environmental Health & Safety Indoor Air Quality Program March 23, 2005

INDOOR AIR QUALITY ASSESSMENT

Residential and commercial construction applications. Product Description: Non-treated dimensional lumber products manufactured from softwoods.

April 21, Dear Mike,

KEEP IT PEST AND CONTAMINANT FREE 10/26/2017 HEALTH CONCERNS PESTICIDES CAN CAUSE: Pests Can

Indoor Air Quality Program

Indoor Air Quality Assessments

What is Asbestos? Asbestos was also used in household items, such as: oven gloves ironing board pads simmer mats for stoves fire blankets.

What s in the Air - Truths, Myths & Simple Strategies

Hazard 10: Volatile Organic Compounds (VOCs)

Health Impacts of the Built Environment. Duane Woik, Green Building Consultant Earth Advantage Institute

Sumit Sharma, Ved Prakash Sharma, R Suresh TERI GRIHA SUMMIT 2016

FOUNDATIONS Bamboo Flooring

Improving Indoor Air Quality. Presented by Theo Cole, EIT

TECHNICAL BULLETIN. MR 7.0 Certified Wood Encourage environmentally responsible forest management.

Healthy Green Buildings

Chinese Drywall Lawsuit: Chinese Drywall Victims Must Act NOW to Join Knauf Plasterboard Lawsuit

Living and working in a busy metropolis like Hong Kong, we normally spend 80% to 90%

RENOVATION UPGRADE REPORT

LEED Best Practices Save $$$

Corrosion of Roof Truss Connector Plates in Farm Buildings S. Beadle, P. Eng.

Corrosion of Roof Truss Connector Plates in Farm Buildings S. Beadle, P. Eng.

Outdoor Air Pollution. Primary vs. Secondary Air Pollutants

About Insulation & R Value - cmhc.ca

Upgrading To An A-Rated Home

The 411 on emitting materials Designing Healthy Interiors A. Costello, P.E., LEED-AP

October 31, Colorado State Judicial Branch 101 West Colfax Avenue, Suite 500 Denver, Colorado 80202

Commercial Building Inspection Course Summary

Debunking Five Common Geothermal Complaints

Which indoor air pollutants raise concern? How can indoor air quality be determined?

NORTH CAROLINA ENERGY STAR CONFERENCE

Emperor Penguins and Efficient Buildings. Resisting frigid temps with thermal breaks.

SAFETY DATA SHEET. SECTION 2 - Hazard Information. SECTION 3 - Composition (may contain one or more of the following ingredients)

ASHRAE and Indoor Air Quality

NADCA S MOLD AWARENESS

Got Mold? A Beginner's Guide on How to Identify Mold and What to Do About It. An Advanced Mold Diagnostics Whitepaper

GDU - MULTISENS. Datalogger with built in sensors Made for accurate indoor air quality measurements. Key features of the GDU MultiSens

Notes on Indoor Air Quality

The opinion on risk assessment on indoor air quality by SCHER

Aalborg Universitet. Formaldehyde in newly built dwellings. Gunnarsen, Lars; Logadóttir, Ásta; Funch, Lis Winther. Published in: Indoor Air 2008

LEED And Your Indoor Environment

Biz Guru Writing Services

Repair Insulate Transform

txt PRODUCT IDENTIFIER: DRICON(R*) FIRE RETARDANT TREATED WOOD AND LUMBER

Pennsylvanians Buying 2012 IECC Homes Will Save Thousands

Indoor Air Quality Self Inspection Checklist

Theory versus practice of energy and comfort in 4 low energy houses in Belgium

Indoor Air Quality Program

SUNDOLITT LTD MANUFACTURERS SAFETY DATA SHEET EXPANDED POLYSTYRENE

NEW HOME ENERGY SAVINGS PROGRAM

* * * Section 1 Chemical Product and Company Identification * * * * * * Section 2 Composition / Information on Ingredients * * *

Dealing with Expansion

OF PARTICLEBOARD. U.S. Department of Agriculture Forest Service Forest Products Laboratory Madison, Wis. USDA FOREST SERVICE RESEARCH PAPER FPL 212

IAQ Workshop. Assessing Common IAQ Contaminants and Ventilation Systems. Dru Sahai

Introduction. IAQ - 5 School Building Summary 2009

Fact: There s increasing interest in assessing and controlling AQ in residences and office buildings

NEW HOME ENERGY SAVINGS PROGRAM

bout your house before you start Repairing or Replacing Roof Finishes

SDS #009. Page 1 of 6 SAFETY DATA SHEET 1. PRODUCT AND COMPANY IDENTIFICATION 2. HEALTH HAZARDS IDENTIFICATION CHRONIC EFFECTS: PRODUCT NAME:

Gemtex Abrasives SAFETY DATA SHEET Coated Abrasives RFD; Mini RFD

Resinoid Bonded Abrasives (08/12)

Safety data sheet for AIREX PXc & PXw

1. Product and company identification. 2. Hazards identification. Page No. 1. a) Product Name : D532

Master Specification ENERTITE by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

Make way for fresh air, live and work healthier

How Do You Spell IAQ? BY HOME ENERGY MAGAZINE

Benchmarking of Energy Savings Associated with Compact Fluorescent Lighting in Homes

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

BEFORE THE ADMINISTRATOR UNITED STATES ENVIRONMENTAL PROTECTION AGENCY PETITION FOR RECONSIDERATION

MOLD INSPECTION REPORT Block Home Inspections LLC

1204 North Road (Rt. 117) Groton, Connecticut 06340

SDS SDS Number: Page 1 of 5

SECTION SUSTAINABLILITY CERTIFICATION REQUIREMENTS - GREEN GLOBES

Indoor Air Quality Assessment Report

Standard practice for installing cellulose building insulation

SOFTWOOD PLYWOOD (Phenol-Formaldehyde Bonded) Construction and other operations where a high quality, high strength, roofing product is desired.

Superintendent of Schools. October 23, Dear Dwight Families,

AN ORDINANCE OF THE TOWNSHIP OF MOUNT PLEASANT PERTAINING TO OUTDOOR FIRES AND TO OUTDOOR FURNACES Ordinance 49-11

SECTION 1 - IDENTIFICATION WRBX (613) (CANUTEC) SECTION 2 - HAZARDS IDENTIFICATION

THE REVISION OF STANDARD 62: WHAT A DIFFERENCE A DECADE MAKES

Analysis of VOCs & Formaldehyde

MATERIAL SAFETY DATA SHEET

This page has been left blank intentionally.

SECTION STRUCTURAL INSULATED PANELS

DECOUSTICS MATERIAL SAFETY DATA SHEET MATERIAL SAFETY DATA SHEET

Health performance indicators of housing

Improve Schools Indoor Environment

Delist, Delay, Decipher

Testing indoor air quality

Transcription:

UREA FORMALDEHYDE FOAM INSULATION Much Ado About Nothing? The purpose of this paper is to provide home owners and home buyers with the facts, and some guidance, concerning the use and safety of urea formaldehyde foam insulation (UFFI). What is it? Urea formaldehyde foam insulation is injected as a mixture of urea formaldehyde resin, an acidic foaming agent, and a propellant, such as air. It was commonly used in existing houses by injecting the foam into areas, such as behind walls, where it was impractical to provide conventional insulation. The insulation was approved in Canada for use in exterior wood-frame walls only. It has a reasonably good R value (thermal resistance). Some formaldehyde gas is released during the on-site mixing and curing. Formaldehyde is colorless, but has a very strong odor, which can generally be detected at concentrations above one part per million. It is this by-product of the curing of the foam that became a controversial issue. Formaldehyde is both a naturally occurring chemical, and an industrial chemical. It is found in dry cleaning chemicals, paper products, no-iron fabrics, diapers, pillow cases, the glue in particle board and plywood, cosmetics, paints, cigarette smoke, and the exhaust from automobiles, gas appliances, fireplaces, wood stoves. It occurs naturally in forests and is a necessary metabolite in our body cells. Ambient formaldehyde levels in houses are typically.03 to.04 parts per million. By comparison, typical levels in the smoking section of a cafeteria are 0.16 ppm. Houses with new carpeting can also reach these levels. The rate at which formaldehyde gasses are released from materials into the air depends on temperature and humidity. The higher the humidity levels and the higher the temperature, the more gas is likely to be released. When Was Urea Formaldehyde Foam Insulation Used? The insulation was used in the 1970's, most extensively from 1975 to 1978, during the period of the Canadian Home Insulation Program (CHIP), when financial incentives were offered by the government to upgrade home insulation levels. The insulation was banned in December 1980, in Canada. It is estimated that over 100,000 homes in Canada were insulated with UFFI (commonly pronounced "you-fee"). The insulation was also used extensively in the United States during the 1970's, and has been used in Europe over the last thirty years. UFFI is still used in Europe, where it was never banned and is considered one of the better "retrofit" insulations. In the United States, the Consumer Product Safety Commission banned the sale of UFFI in the United States in 1982, and shortly thereafter a law prohibiting the sale of urea formaldehyde was enacted. In April 1983, the U.S. Court of Appeal struck down the law because there was no substantial evidence clearly linking UFFI to health complaints. UFFI is not widely used in the USA today. Who Installed It? UFFI was not a do-it-yourself product. The foam was machine mixed on-site, and injected into wall cavities where it expanded to fill the cavity. Like many new and fast growing industries (particularly those supported by government grants), workmanship and quality control were often less than perfect.

What Caused The Controversy? One of the first problem cases involving formaldehyde was in the United States. This involved an extremely air-tight and poorly ventilated mobile home, apparently with a poorly-mixed, half-formed UFFI. This started to raise government suspicions about the insulation. (In other mobile home studies, any elevated levels of formaldehyde were traced to the paneling or carpets, not UFFI.) A laboratory study which produced nasal cancers in rats that were exposed to high levels of formaldehyde, increased the concern. Following some press releases and cautioning by authorities, a number of home owners began to report problems that included respiratory difficulties, eye irritation, running noses, nosebleeds, headaches and fatigue. Very quickly, fear and suspicion led to the conclusion that a problem must exist. Few issues have stronger impact than a potential health concern, especially if the suspected cause is new, poorly understood and widely used. In the case of UFFI, the uneasiness and uncertainty were especially difficult to fathom or control, since the material was hidden from sight, and the reported symptoms were identical to those often experienced in our heated, dry indoor air. Although there were no substantiated problems clearly attributable to the foam, urea formaldehyde foam insulation was banned as a precautionary measure. Research was initiated to evaluate the problem, and to determine what should be done. No one knew exactly how many homes had UFFI, and it was often difficult to find out whether a home had UFFI. The problem was further complicated by the fact that the foam was often used somewhat inappropriately in walls of solid masonry houses, in attics, in cavities where freeze-up of pipes had occurred, and even as an acoustical insulation in party walls in row houses, and in the ceilings between the first and second floor of the house. The fears of cancer and other health problems were only the beginning of the story. These fears caused a reduction in the value of real estate. The costly "remedial" measures and the long term stigma attached to UFFI houses became a marketplace reality because of the perceived health problems. The federal government set guidelines for reducing formaldehyde levels in houses, and removal techniques were specified. The initial threshold level set for formaldehyde gas was 1.0 part per million (ppm). As testing methods improved, the level was brought down to 0.5 ppm and, eventually, 0.1 ppm. The threshold level became very conservative, indeed. A court case which eventually set records was initiated in Quebec, in which the claimants accused the federal government, manufacturers and others of bringing a dangerous material to the market. An Interesting Twist Those charged with the task of designing and refining remedial measures set out to find the worst cases to test their theories, but they encountered an unexpected problem. They couldn't find any UFFI insulated houses with formaldehyde gas levels above 0.1 ppm, let alone 0.5 ppm or 1.0 ppm. Even in the few houses that tested at levels approaching 0.1 ppm, these results were rarely duplicated in subsequent testing. It became known that the levels of formaldehyde decrease rapidly after the foam has been installed. Within several days of the application, formaldehyde levels typically return to ambient house levels. As the body of information grew, it became clear that finding a single house that exceeded this very conservative threshold level was going to be a challenge. In fact, in reviewing several thousand files, not one house was found with levels of formaldehyde which remained above 0.1 ppm! The highest levels were found in homes with brand new carpeting which were tested on a hot summer day. The same house tested two weeks later showed levels typical of any house, with or without UFFI.

The presence of UFFI does not affect the amount of formaldehyde in the indoor air. Indeed, while not statistically significant, the homes tested were found, on average, to have formaldehyde levels slightly below that of homes of similar ages without UFFI. In a study in Britain, people who worked in environments with high formaldehyde levels, such as morticians and laboratory technicians, were studied for possible health effects. These subjects were found to have a less than average number of respiratory diseases, and actually lived slightly longer on average, on the whole. (Again, while this may not be statistically significant, it suggests that low levels of formaldehyde are not harmful.) A number of studies have been done examining the health effects of UFFI. Studies using random samples of UFFI and non-uffi homes done before the ban showed no impact of UFFI on health. However, studies done after the ban showed increased reporting of symptoms, even for such things as constipation and deafness which have no biological basis. When no correlation could be found between formaldehyde gas and health problems, other possible problems related to UFFI were investigated. Mould and fungi, dust mites, and un-named "UFFI gases" were all investigated as possibilities. None were linked to UFFI. There was no damage to house framing or materials caused by UFFI. Conclusions UFFI is one of the most thoroughly investigated, and most innocuous building products we have used. After the longest and most expensive civil case ever held in Canada (eight years) was concluded in the Quebec Superior Court, not only was no basis for a settlement found, but the plaintiffs were obliged to pay most of the costs. The conclusion to be drawn from all this is that urea formaldehyde foam insulation has not been shown to be a health concern. It is not the purpose of this paper to determine why or how all of this controversy arose without any proof. Suffice to say that people with the best intentions were working in the public interest, and perhaps erred on the conservative side. In retrospect, although the results were unfortunate, we would hate to think that people responsible for the health of consumers would err on the other side. We believe that those who have urea formaldehyde foam insulation in their homes should enjoy their houses, and sleep well at night. It is the sincere hope of the authors that the market place will respond appropriately. The owners of properties with this type of insulation should not be penalized financially, and no stigma should be attached to these homes. We would further urge real estate associations and boards across Canada to consider dropping the UFFI clause from purchase contracts. Similarly, we would ask mortgage lenders not to penalize those who have UFFI in their homes. UFFI is simply not the problem it was once feared to be. Still Concerned? While we do not believe UFFI to be a problem, other household materials and products can produce formaldehyde, and other air pollutants for that matter. If you suspect your indoor air quality to be poor, there are Environmental Consultants listed in the Yellow Pages of your phone book, often in the Business and Industrial section.

References/Bibliography Development Of A Canadian Standard For Urea Formaldehyde Thermal Wall Insulation The National Research Council of Canada (1981) Building Practice Note #19 - Urea Formaldehyde Foam Insulation Division of Building Research The National Research Council of Canada (April 1981) Building Practice Note #23 - Urea Formaldehyde Foam Insulation Problem Identification & Remedial Measures for Wood Frame Construction Division of Building Research The National Research Council of Canada (August 1981) Exposure To High Concentration Of Formaldehyde. A Case Study The Institute For Research In Construction The National Research Council of Canada (1985) Mr. Bob Platts - Canada Consultants Limited - Ottawa, Ontario Dr. Geoffrey Norman - Department of Clinical Epidemiology & Biostatistics McMaster University Health Science Center Hamilton, Ontario Warning On Urea Formaldehyde Foam Insulation Energy Mines Resources Canada An Update On Formaldehyde U.S. Consumer Product Safety Commission, Washington, D.C. (1990) Builder's Note #3 - Formaldehyde The Canadian Home Builder's Association Millions To Remove Urea Foam, But Health Risk Still Unknown The Globe & Mail Newspaper (March 29, 1986) Consumer and Corporate Affairs Canada (UFFI Centrex) Booklet About UFFI Information Bulletin - Formaldehyde Information Booklet - UFFI Information Bulletin - How To Determine Whether You Have UFFI In Your Home. Information Bulletin - Technical Research Information Bulletin - Purchase Of A Home Insulated With UFFI Information Bulletin - Information Update Information Bulletin - Corrective Measures - Ceiling Information Bulletin - Interim Corrective Measures Checklist Information Bulletin - Heat Recovery Ventilators Home Owners With Urea - Foam Insulation Lose Civil Suit For Damages The Globe & Mail Newspaper, Toronto (December 14, 1991)

Dropping The UFFI Clause: What Are Members Bound To Do? The Law Reference File #9 - Quebec Real Estate Association House Buyers Find UFFI, But Only Get $100 Damages From B.C. Judge Lawyer's Weekly (July 7, 1989) Comparison of Health of Occupants and Characteristics of Houses Among Controlled Homes and Homes Insulated With Urea Formaldehyde Foam Broder, I., Cole, P., Corey, P., Lipa, M., Mintz, S. & Nethercott, J. Rosen, (1988) " Environmental Research, Volume 45", Pages 141-203. Contents of this site Copyright 2013/2014 Carson, Dunlop & Associates Ltd. All rights reserved. No text or graphical material may be copied from this site without the express written permission of Carson, Dunlop & Associates Ltd. Line drawings are from the Carson Dunlop Home Inspection Training Program and Home Inspection Software Tool - Horizon