inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Similar documents
inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Design of a standalone, modular test facility for measuring sound transmitted through a common ceiling plenum

Volume II FWPRDC PN Maximising impact sound resistance of timber framed floor/ceiling systems. Page 183

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Relationship between flanking noise through a common ceiling plenum and plenum absorption George van Hout, John Pearse and Brian Donohue

Maximising impact sound resistance of timber framed floor/ ceiling systems Volume 3

ICF/Building System FSTC Test Report

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Measurements of junction vibration level differences of timber framed constructions

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

KINETICS NOISE CONTROL TEST REPORT #AT001049

Determination of the sound reduction and sound absorption of a railroad noise barrier

COMPARISON OF MEASURED AND PREDICTED SOUND INSULATION FOR A THERMAL RETROFITTED BUILDING

Flanking sound transmission in an innovative lightweight clay block building system with an integrated insulation used at multifamily houses

1.0 INTRODUCTION BUILDING REGULATIONS SOUND INSULATION REQUIREMENTS TEST PROCEDURE AND ANALYSIS...3

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

KINETICS NOISE CONTROL TEST REPORT #AT001110

NODALIZATION OF ISOLATOR FOR FLOATING FLOOR DESIGN. C.K. Hui and C. F. Ng

LABORATORY MEASUREMENT OF THE SOUND REDUCTION IMPROVEMENT INDEX BY ACOUSTICAL LININGS DUE ONLY TO RESONANT TRANSMISSION

Results of FIIC and FSTC Measurements at Harvard Estates

KINETICS NOISE CONTROL TEST REPORT #AT001021B

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF BAILEY INTERIORS EXPOSED NU SHADEX PERFORATED PLASTER CEILING TILES (600MM

Measurement of Airborne & Impact Sound Insulation. University of Durham, Pavilion H, Howlands Farm, Durham.

Measurement of Sound Absorption Coefficient for Perfopan slotted Wall Panels Code No. SLT 7x7-PR 12%, DS 270, on 45 mm mineral wool

Roomtmove 3/9 Church Road MAddington WA 6109

Communal 51 Ceiling Systems by Vogl

B Page 1 of 21-

KINETICS NOISE CONTROL TEST REPORT #AT001052

NO. 19 WILBERFORCE ROAD COXHEATH, MAIDSTONE, KENT ME17 4HD SOUND INSULATION TESTING. On behalf of: Oscar Acoustics

Test report No B0082 IN CM 26-M56-I

Test report No B0082 IN CM 26-M55-I

Testing Procedure: AS ISO

ACOUSTIC EFFICIENCY OF FALSE CEILINGS: STUDY ON THE INFLUENCE OF DISTANCE FROM THE CEILING SLAB

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF 2MM ECHOPANEL WALL TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

Testing Procedure: AS ISO

THE FRAME RESIDENTIAL DEVELOPMENT, SPORTCITY, MANCHESTER THE CONCRETE CENTRE LTD 1.0 INTRODUCTION...2

TECHNICAL DOCUMENT - SOUND INSULATION R9 SYSTEM. Dated: 30 August 2013

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF BAILEY INTERIORS CASINO 600MM

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF BAILEY INTERIORS CELL AIR 1200MM

CASE STUDY OF THE SOUND REDUCTION OF VARIOUS RESIDENTIAL GLAZING TREATMENTS

The uncertainty in sound insulation of an industrially prefabricated lightweight timber construction

Comparative Impact Performances of Lightweight Gym Floors

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Modal analysis and flanking sound insulation in connected panels of cross-laminated-timber at low frequencies

KINETICS NOISE CONTROL TEST REPORT #AT001067

Façade insulation at low frequencies influence of window design

KINETICS NOISE CONTROL TEST REPORT # AT001084

SPEEDPANEL. Fire & Acoustic Rated Wall Systems. Speedpanel. Intertenancy systems SPEEDPANEL

The specimen B W was identified by the client as a Skyfold Classic operable partition, with panels, seals, and clearances in configuration 4E.

INTRODUCTION SPECIMEN DESCRIPTION

ISO INTERNATIONAL STANDARD

KINETICS NOISE CONTROL TEST REPORT #AT001032

Measurement series to verify the accuracy of Stora Enso Acoustic Prediction tool - SEAP

Façade sound insulation of residential houses within Hz

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

KINETICS NOISE CONTROL TEST REPORT #AT001108

The Optimization of a Wooden Floor Design Based on Validated Finite Element Models

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Comparison of measured and predicted sound insulation for a thermal retrofitted building

CONDUCTED: Page 1 of 6

RC CHANNEL ACOUSTIC ASSEMBLY

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Hive Acoustic Report.

Proceedings of Meetings on Acoustics

Prediction of the acoustic performance of floor coverings on lightweight floors

Delia Chamberlain, Vice President, Kolay Floors Steve Hedback and Joel Esselstrom, SSA Acoustic, LLP

Testing Procedure: AS ISO

Ozone Panel 120 Acoustic Assessment and Optimization

Low frequency noise and induced vibration from air-traffic and military training Processes and new mitigation measures

DETAILED ANALYSIS OF MEASUREMENT RESULTS OF FLANKING TRANSMISSION ACROSS A JUNCTION COM- POSED OF DOUBLE WALLS CARRIED OUT ON A HALF SCALED TEST BENCH

OLIVE VILLAS, SANDOWN LANE, LIVERPOOL, L15 4HU

REDUCING THE INGRESS OF URBAN NOISE THROUGH VENTILATION OPENINGS

COMPARISON AMONG METHODS TO MEASURE THE SOUND INSULATION OF BUILDING FAÇADES

Laboratory measurements of the reduction of transmitted impact sound by floor coverings on a heavyweight reference floor (According to ISO )

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

KINETICS NOISE CONTROL TEST REPORT #AT001035

CONCRETE PERFORMANCE. Jeff Dyson Head of Housing Solutions. The Concrete Centre

ASTM C 423 SOUND ABSORPTION TEST REPORT. Rendered to: FABRI TRAK SYSTEMS, INC. SERIES/MODEL: FabriSpan. TYPE: Ceiling System. Summary of Test Results

Experimental study of sound insulation performance in the wood-framed building

Evidence of Performance Joint sound reduction of filling material

Rating of Sound Insulation of Wall Impact Sounds in Buildings. Shih-Pin Huang and Rong-Ping Lai. Reprinted from JOURNAL OF BUILDING ACOUSTICS

CONSIDERATIONS ON THE AIRBORNE SOUND INSULATION OF A MODERNISED HOTEL

Speech Privacy outcomes from Green star Design and As-Built v1.1 rating tool

FLANKING TRANSMISSION IN STEEL-CONCRETE COMPOSITE FLOORS

SABIN 3.0 tutorial. The reverberation time of a newly designed room has to be given a certain desired value.

Rainfall and impact noise measurements on metal roof tiles

Lightweight floor/ceiling systems with improved impact sound insulation

On the use of scaled models in building acoustics

Numerical prediction and experimental validation of sound transmission loss for different acoustic materials

Measuring L n without using a tapping machine?

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Rainfall and impact noise measurements on metal roof tiles

A combined approach for base isolation design

Specialists in Acoustic Flooring and House to Flat Conversions

LABORATORY MEASUREMENT OF AIRBORNE SOUND INSULATION OF PIR ROOF PANELS (According to ISO )

Acoustic Performance of Light Steel Framed Systems

Transcription:

Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 5.1 INCLUSION OF DAMPING IN A FEM MODEL OF LOW FREQUENCY SOUND IN ROOMS S. Maluski, B.M. Gibbs Acoustics Research Unit, The University of Liverpool, PO BOX 147, L69 3BX, Liverpool, United Kingdom Tel.: +44 151 794 4936 / Fax: +44 151 794 4937 / Email: s.maluski@liv.ac.uk Keywords: DAMPING, LOW FREQUENCY, FEM, SMALL ROOMS ABSTRACT A Finite Element (FE) model was developed to investigate the sound insulation between dwellings at low frequencies. It has been found that for small empty rooms (smaller than 50m 3 ), the airborne sound insulation properties of the party wall depend on the structural modal characteristic of the party wall and on the acoustic modal characteristics of the two rooms. They therefore are influenced by the edge conditions of the party wall and by room configuration and size. As dwellings usually are furnished, it also is necessary to examine the effects of localized absorption on the acoustic modal characteristic. Preliminary comparisons between measurements and prediction of the frequency response and sound level difference were promising despite the fact that damping was not included in the FE model. At higher frequencies, the agreement is less good for the empty room and damping must be included in an appropriate form, before investigating the effects of furniture and fittings. Different ways of including room damping are considered and comparisons between measured and predicted frequency response were carried out to validate the FE model. 1 - INTRODUCTION The airborne sound insulation in dwellings at low frequencies has been investigated by developing a Finite Element (FE) model [1]. The model was validated by comparing measurements and predictions, which were promising despite the fact that damping was not included in the model. The outcomes of this investigation highlighted that the sound pressure level difference is controlled by the modal characteristics of the party wall and of the acoustic fields of the two empty rooms. However, the aim of this investigation is to recreate what is happening in dwellings. As rooms usually are furnished, it then becomes necessary to examine the effects of surface and localized absorption on the acoustic modal characteristic and level difference. Damping must therefore be included in the FE model of an empty room in a suitable form before investigating the effects of furniture and fittings. The present paper describes the adjustments to the FE model in order to obtain the most accurate predicted frequency response for empty rooms. 2 - MEASUREMENTS The sound field of different room constructions have been investigated, including brickwork walls, concrete floor and concrete ceiling, and timber-frame walls and timber floors. The acoustic fields were measured using MLSSA [2] and a large speaker, located in a corner, with a flat frequency response from 30Hz to 2kHz. The room frequency response was measured from 25Hz up to 205Hz, for each room. 3 - ASSIGNMENT OF DAMPING TO THE ACOUSTIC F.E. MODEL Using the same software package as in a previous investigation [1 3], different F.E. models were defined to represent the field measurements. The model was defined according to the room dimensions and to the upper frequency of interest, 205Hz. The acoustic modes were processed and a point source defined at a corner of the room. The frequency response was processed at field points identified from the selected microphone positions in the field. The power of the real speaker being unknown, the predicted frequency response was adjusted to the measurements by visual inspection.

Copyright SFA - InterNoise 2000 2 Acoustic damping can be included in the acoustic F.E. model either by assigning a complex admittance to the six surfaces or by providing a modal damping factor to the room modes. The surface admittance, which relates to the absorption coefficient, is included as an impedance matrix C to the undamped expression of the acoustic field. The sound field is expressed as ( [K] + iω [C] ω 2 [M] ) {p} = iρ 0 ω {Q} (1) where K is the stiffness matrix and M is the mass matrix; where p and Q are the amplitudes of nodal pressures and flows, respectively. In this model, the surface absorption must be assigned before processing the room modes and therefore does not vary with frequency. The modal damping is equivalent to adding an extra imaginary term proportional to the eigenfrequency and can vary between 0 (i.e. no damping) to unity. The advantage of this method compared with the surface absorption is that a frequency dependent value can be assigned. 4 - EFFECT OF SURFACE ABSORPTION At present, no accurate method of measurement for absorption at low frequencies is available [4,5]. Therefore, preliminary estimates were made by calculating the acoustic damping from the half-power bandwidth of the peaks of the measured room response. Half-power bandwidth can only be estimated from well separated peaks. However, despite the non-statistical acoustic field of small rooms, only one or two peaks were sufficiently separated in the frequency range of interest. Therefore, a best fit was obtained by incremental variation of input damping. Figure 1 shows the measured and predicted frequency response of a room of plastered brick walls and concrete floor and ceiling. The room dimensions are 5.75 x 4.88 x 4.24m. Peaks and dips are displayed and show that a surface of assumed absorption coefficient of 0.02 gives a best agreement with measurement. Figure 1: Surface absorption to model the frequency response of a room with brick walls and concrete floor and ceiling. Figure 2 shows the measured and predicted frequency response of a room with plasterboard and timberframe walls, floor and ceiling for a range of surface absorption coefficients. The room of dimensions 4.24 x 2.84 x 2.40m was a bedroom in a semi-detached house. The predicted curves display the same signature as the measured. Agreement is best for values of absorption coefficient around 0.15. Figure 3 shows the predicted and measured frequency responses with a resolution of 1/12 octave band. An absorption coefficient of 0.15 seems the most appropriate to represent the sound field. However, as seen in Figures 1 and 2, agreements could be improved in some parts of the spectra by setting different values. Adjustment of the FE model by modal damping also was considered. Figure 4 displays the predicted frequency response for different values of modal damping compared with the frequency response of the room with plastered and timber-frame walls. The room of dimensions 2.62 x 2.32 x 2.40m also was a

Copyright SFA - InterNoise 2000 3 Figure 2: Surface absorption to model the frequency response of a room with timber-frame walls, floor and ceiling. bedroom in a semi-detached house. It can be observed again that the predicted frequency responses have the same signature as the measured frequency response. A modal damping of 0.05 gives a predicted response that is over-damped values above 120Hz whereas a modal damping of 0.025 gives better agreement. This agreement can be improved by assigning different values of modal damping to different parts of the spectrum. For example, a value of 0.05 up to 120Hz, 0.025 up to 135Hz and 0.01 up to 175Hz. 5 - CONCLUDING REMARKS Attempts were made to improve the agreement between field measurements and predictions by assigning a surface absorption or modal damping to the acoustic F.E. model. It was found that both methods provide good agreement between measurements and prediction over the frequency range of interest. Modal damping offers the advantage that the damping can be varied with frequency. However it is not suitable for investigating the effect of furniture which might introduce frequency shifts and extra peaks as well as damping to the room response. It seems therefore more appropriate to consider the surface admittance method which not only reproduces the effect of the acoustic damping on the frequency response but can also include the effect of wall vibrations. It was observed that a surface absorption coefficient of 0.02 is required to model a room made of brickwork and concrete and a surface absorption coefficient of 0.15 is required for a room of plastered timber-frame walls, floor and ceiling. ACKNOWLEDGEMENTS The authors gratefully acknowledge the financial support by the Engineering and Physical Sciences Research Council of the United Kingdom. REFERENCES 1. S. Maluski and B.M. Gibbs, Application of a Finite Element model to low frequency sound insulation in dwellings, Submitted for final approval in Journal of Acoustical Society of America 2. MLSSA, Reference Manual, version 9.0, DRA Laboratories, 1994 3. Sysnoise, Software V.5.4, 1996 4. J.L. Davy, The variance of decay rate at low frequencies, Applied Acoustics, Vol. 23, pp. 63-79, 1988 5. J.L. Davy, The variance of reverberation time measurements due to loudspeaker position variation, Journal of Sound and Vibration, Vol. 132(3), pp. 403-409, 1989

Copyright SFA - InterNoise 2000 4 Figure 3: Surface absorption compared with measured with a 1/12 octave band resolution. 6. D.A. Bies and C.H. Hansen, Engineering Noise Control theory and practice, 2nd Ed. E & FN SPON, 1996

Copyright SFA - InterNoise 2000 5 Figure 4: Effect of modal damping on the predicted frequency response of room with timber-frame walls.