Seismic Design Requirements

Similar documents
Sponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts

Emeryville's Seismic Hazard Mitigation Ordinance

City of Tacoma Planning and Development Services

PRESCRIPTIVE COMPLIANCE METHOD

RESIDENTIAL SEISMIC RETROFITS

BUILDING AND SAFETY DIVISION STRUCTURAL OBSERVATION - REVISITED, A YEAR LATER

Structural Engineering

FEMA P 50 & FEMA P 50 1

PRESCRIPTIVE COMPLIANCE METHOD

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS

Simplified Seismic Assessment & Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & FEMA P-50-1

CODE ANALYSIS REPORT SECOND FLOOR

Available at: Last Modified: December 2012

Commercial Remodel Permit

CTC MEETING #25 CHILD WINDOW SAFETY REPORT

Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

SEATTLE CENTRAL COLLEGE BROADWAY PERFORMANCE HALL SEATTLE, WASHINGTON STRUCTURAL EVALUATION FOR PREPARED BY PCS STRUCTURAL SOLUTIONS

2015 International Existing Building Code Overview Based on the International Existing Building Code (IEBC )

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

STRUCTURAL DESIGN REQUIREMENTS (SEISMIC PROVISIONS) FOR EXISTING BUILDING CONVERTED TO JOINT LIVING AND WORK QUARTERS

CALIFORNIA BUILDING AND SAFETY COMMISSIONERS. nmi 'DEI ERIC GARCETTI MAYOR PROPOSED SUBSTANTIAL STRUCTURAL DAMAGE ORDINANCE- COUNCIL FILE

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE

2012 IEBC Fundamentals 12/11/2017. Copyright 2012 International Code Council 1

October 25, Honorable Mayor and City Council. THROUGH: Public Safety Committee. Planning Department

Commercial Reroof Permit Program

ADMINISTRATIVE BULLETIN. TITLE : Procedures for Implementation of SFBC Chapter 34B

3.5 Tier 1 Analysis Overview Seismic Shear Forces

HALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE

Commercial Solar Photovoltaic System Permit

Title 15 BUILDINGS AND CONSTRUCTION

Chapter 13C GREEN BUILDING REQUIREMENTS

A minimum of 25% of any money spent upgrading areas of primary function shall be devoted to ADA upgrades. Existing non-compliant areas include:

1.0 General Provisions

TOWN OF ECKVILLE BYLAW 638/02 BUILDING PERMIT BYLAW

CEQA Categorical Exemption Determination

Minnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

WABO TCD ASSEMBLY MOTION VOTING RECOMMENDATIONS (2016 GROUP B)

2015 IBC Chapters 1 and 35

gwinnettcounty RACKING SHELVING CONVEYOR CONSTRUCTION CODE COMPLIANCE GUIDELINES Permitting Procedure

PROPOSED SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS 2016 Edition

SEISMIC DESIGN GUIDELINES

COMMERCIAL BUILDING PERMIT

BUILDING PERMIT APPLICATION PACKAGE

ADMINISTRATION CHAPTER 1

101.1 Title. These regulations shall be known as the Existing Building Code of Massachusetts, hereinafter referred to as this code.

Building Code 8 th Edition

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Deck Permit Zoning requirements Adopted Code Submission Requirements Fees Review time Contractor licensing Inspections

Signage Code. H101.2 Signs exempt from permits. The following signs are exempt from the requirements to obtain a permit before erection:

Permit and Application Fee Schedule Plan Review Fees are in addition to permit application fees.

SANTA BARBARA COUNTY ZONING ADMINISTRATOR STAFF REPORT October 21, 2011

INTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004

Tohono O odham Nation. Adoption of Building Codes

New Commercial Construction Permit

ORDINANCE NO. 16- The City Council of the City of West Hollywood does hereby ordain as follows:

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

TITLE 15: BUILDINGS AND CONSTRUCTION GENERAL PROVISIONS

Requirements for Municipal and Private Developments Document Last Updated in Database: April 27, 2016

CLEAR CREEK COUNTY BUILDING DEPARTMENT PERMIT PROCEDURES AND REQUIREMENTS FOR COMMERCIAL AND MULTI-FAMILY DEVELOPMENTS

635 BUREAU OF BUILDING CODES AND STANDARDS MAINE UNIFORM BUILDING AND ENERGY CODE - COMMERCIAL BUILDING CODE OF MAINE

Municipal Services Agency Building Inspection General Information: (916)

Ordinance No July 1, 2016

Alameda County Assessor s Records. Step 1. Fill-in the Building Owner information below, and then go to Step 2. Building Owner NAME.

HAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS

ADMINISTRATIVE BULLETIN. TITLE : Local Equivalency for Exiting Through a Garage Area for Type V, Group R Buildings

Fill out all sections or mark with N/A (not applicable)

The International Building Code (IBC ) is a model code that provides minimum requirements to safeguard the public health, safety and general welfare

Structural Design Issues for Housing and Small Buildings in British Columbia: Information for Local Authorities, Homeowners and Developers

The Commonwealth of Massachusetts Department of Public Safety Code and Other Requirements for Building Permits Filing Instructions

3. SURVEY AND ASSESSMENT PROCEDURES FOR EXISTING BUILDINGS

JDB CODE SERVICES, INC.

HONEY BROOK TOWNSHIP

Fill out all sections or mark with N/A (not applicable)

CTC to BCAC IBC/ADA Coordination/ IEBC 3-2, 4-1 thru 4-8a, 7-1 thru 7-3, 8-1, 12-1, 14-1 and 15-1

Burbank Municipal Code A300: ADOPTION OF CODE: Page 8 of 13

CHAPTER 6 INTERNATIONAL RESIDENTIAL CODE

(d) Metal buildings used for industrial uses are not exempt from additional landscape standards as required in Section (e).

Solar Photovoltaic System Permit

The Council of the City of Palo Alto does ORDAIN as follows:

SITE PLAN CRITERIA FOR MUNICIPAL SOLID WASTE & RECYCLABLES STORAGE & ENCLOSURE REQUIREMENTS

ARTICLE 10: Wireless Services and Communications

CEQA Categorical Exemption Determination

Inspection and Quality Assurance Requirements for Metal Plate Connected Wood Trusses. Educational Overview

Individual Truss Marking Is it a Building Code Requirement?

Culver City Building Safety Division Mandatory Green Building Program

DRAFT ORDINANCE NO. RD:JAC:CER 9/1/2016

2012 NC Energy Conservation Code (2012 NCECC) Commercial Building Compliance

Phoenix Building Construction Code Updated Amendments to the Administrative Provisions

ADDENDA #9- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services

EXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application

CHAPTER 34 EXISTING BUILDINGS

SUMMARY OF FIRE SPRINKLER REQUIREMENTS FOR ALTERATIONS TO EXISTING BUILDINGS 2015 I-Codes

City of Placerville Planning Commission AGENDA

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Transcription:

City of Medford Municipal Code Chapter 9 Presented by the Building Safety Department

THESE PROVISIONS PRESCRIBE THE DESIGN REQUIREMENTS OF EXISTING BUILDINGS UNDERGOING: CHANGE OF OCCUPANCY ADDITIONS ALTERATIONS SECTION 9.600

FOR CHANGE OF OCCUPANCY AND STRUCTURAL ADDITIONS THE DESIGN STANDARD SHALL BE THE CURRENT EDITION OF OREGON STRUCTURAL SPECIALTY CODE. FOR OTHER WORK COVERED UNDER THESE PROVISIONS THE DESIGN STANDARD SHALL BE FEMA 178, NEHRP HANDBOOK FOR THE SEISMIC EVALUATION OF EXISTING BUILDINGS. SECTION 9.610

THE USE OR CHARACTER OF A QUALIFIED HISTORIC BUILDING OR PROPERTY, OR PORTION THERE OF, SHALL BE PERMITTED TO CONTINUE IN USE REGARDLESS OF ANY PERIOD OF TIME IT MAY HAVE BEEN UNOCCUPIED OR IN OTHER USE; PROVIDED THE BUILDING OR PROPERTY OTHERWISE CONFORMS TO ALL APPLICABLE REQUIREMENTS OF THIS CHAPTER. SECTION 9.615

THE TABLE BELOW IS USED TO CLASSIFY THE RELATIVE HAZARD OF ALL BUILDING OCCUPANCIES; RELATIVE HAZARD OCC. CLASSIFICATION 5 (HIGHEST) A, E,I-1.1, 1-3, H-1, H-3, H-6, H-7 4 R-1, SR, 1-2, 1-3.1 3 B, I-1.2, I-1.3, M 2 F, S, H-4, H-5 1 (LOWEST) R-3, U SECTION 9.620

AN OCCUPANCY CHANGE OF THE SAME OR A LOWER RELATIVE HAZARD CLASSIFICATION NUMBER WILL NOT REQUIRE SIESMIC IMPROVEMENTS, UNLESS THE CHANGE RESULTS IN AN OCCUPANT LOAD INCREASE OF MORE THAN 20% SECTION 9.620

AN OCCUPANCY CHANGE TO A HIGHER RELATIVE HAZARD CLASSIFICATION NUMBER WILL NOT REQUIRE SEISMIC IMPROVEMENTS, WHEN THE NET FLOOR AREA OF THE CHANGED PORTION OCCUPIES LESS THAN 15% OF THE NET FLOOR AREA OF THE BUILDING AND WHERE THE CHANGE DOES NOT RESULT IN AN INCREASE IN OCCUPANT LOAD AS DEFINED BY THE OREGON STRUCTURAL SPECIALTY CODE OF MORE THAN 100 PERSONS. SECTION 9.620

ALL OTHER CHANGES TO A HIGHER RELATIVE HAZARD OCUPANCY WILL REQUIRE SEISMIC IMPROVEMENTS USING THE CURRENT EDITION OF THE OREGON STRUCTURAL SPECIALTY CODE. SECTION 9.620

ALL STRUCTURES, WHICH ARE BEING CONVERTED TO ESSENTIAL FACILITIES, AS DEFINED IN THE OREGON STRUCTURAL SPECIALTY CODE, SHALL COMPLY WITH CURRENT SEISMIC REQUIREMENTS, REGARDLESS OF OTHER REQUIREMENTS IN THIS SECTION. SECTION 9.620

AN ADDITION THAT IS NOT STRUCTURALLY INDEPENDENT FROM AN EXISTING BUILDING SHALL BE DESIGNED AND CONSTRUCTED SUCH THAT THE ENTIRE BUILDING CONFORMS TO THE SEISMIC FORCE RESISTANCE REQUIREMENTS FOR NEW BUILDINGS UNLESS THE FOLLOWING THREE CONDITIONS ARE MET: SECTION 9.625

THE ADDITION SHALL COMPLY WITH THE REQUIREMENTS FOR NEW BUILDINGS, AND THE ADDITION SHALL NOT INCREASE THE SEISMIC FORCES IN ANY STRUCTURAL ELEMENT OF THE BUILDING BY MORE THAN 5 PERCENT UNLESS THE CAPACITY OF THE ELEMENT SUBJECT TO THE INCREASED FORCES IS EQUAL TO OR GREATER THAN THAT REQUIRED FOR NEW BUILDINGS, AND SECTION 9.625

THE ADDITION SHALL NOT DECREASE THE SEISMIC RESISTANCE OF ANY STRUCTURAL ELEMENT OF THE EXISTING BUILDING UNLESS THE REDUCED SEISMIC RESISTANCE OF THE ELEMENT IS EQUAL TO OR GREATER THAN THAT REQUIRED FOR NEW BUILDINGS. SECTION 9.625

IF A BUILDING IS DAMAGED BY FIRE, ALL DAMAGED LATERAL LOAD RESISTING COMPONENTS OF A BUILDING S STRUCTURAL SYSTEM MUST BE DESIGNED AND REBUILT TO CURRENT PROVISIONS OF THE OREGON STRUCTURAL SPECIALTY CODE. SECTION 9.630

THESE COMPONENTS MUST ALSO BE CONNECTED TO THE BALANCE OF THE UNDAMAGED LATERAL LOAD RESISTING SYSTEM IN CONFORMANCE WITH CURRENT CODE PROVISIONS. UNDAMAGED COMPONENTS NEED NOT BE UPGRADED TO CURRENT LATERAL LOAD PROVISIONS OF THE CURRENT CODE, UNLESS REQUIRED BY OTHER PROVISIONS OF THE OREGON STRUCTURAL SPECIALTY CODE. SECTION 9.630

WHEN AND ALTERATION, FOR WHICH A BUILDING PERMIT IS REQUIRED, HAS A VALUE OF MORE THAN $100,000 A FEMA 178 EVALUATION IS REQUIRED. A LETTER OF INTENT TO HAVE A FEMA 178 EVALUATION PERFORMED MAY BE SUBMITTED ALONG WITH THE PERMIT APPLICATION. THE EVALUATION MUST BE COMPLETED BEFORE ANY FUTURE PERMITS WILL BE ISSUED. THE FOLLOWING SHALL BE EXEMPTED FROM THIS REQUIREMENT: SECTION 9.635

BUILDINGS CONSTRUCTED OR RENOVATED TO SEISMIC ZONE 2, 2B OR 3 UNDER A PERMIT ISSUED AFTER JANUARY 1, 1974. ONE-AND-TWO FAMILY DWELLINGS. SINGLE STORY, LIGHT METAL BUILDINGS LESS THAN 5,000 SQUARE FEET IN AREA. LIGHT WOOD BUILDINGS LESS THAN 5,000 SQUARE FEET IN AREA. A PREVIOUSLY PREPARED SEISMIC STUDY MAY BE SUBMITTED FOR CONSIDERATION BY THE DEPARTMENT AS EQUIVALENT TO A FEMA 178 EVALUATION. SECTION 9.635

SEISMIC HAZARDS SHALL BE MITIGATED IN CONJUCTION WITH BUILDING ALTERATIONS AND REPAIRS IN UNREINFORCED MASONRY BUILDINGS, AS FOLLOWS: WHEN THE ROOF COVERING IS REPAIRED OR REPLACED, THE BUILDING STRUCTURAL ROOF SYSTEM, ANCHORAGE, AND PARAPET SHALL BE REPAIRED AND REHABILITATED PER APPENDIX C OF THE DESIGN STANDARDS- FEMA 178, OR SECTION 9.640

WHEN THE COST OF ALTERATION WORK WHICH REQUIRES A BUILDING PERMIT IN A 2 YEAR PERIOD EXCEEDS A $15 PER SQUARE FOOT FOR THE TOTAL NET FLOOR AREA IN THE BUILDING, THEN THE BUILDING SHALL BE IMPROVED SEISMICALLY PER SECTION 9.610. SECTION 9.640

COSTS FOR SITE IMPROVEMENTS AND MANDATORY FM41 AGREEMENTS, MANDATED ADA IMPROVEMENTS, MANDATED LANDSCAPING AND MANDATED OR VOLUNTARY SEISMIC IMPROVEMENTS WILL NOT BE INCLUDED IN THE $15 PER SQUARE FOOT AMOUNT. SECTION 9.640

THE BUILDING SAFETY DIRECTOR MAY APPROVE A MULTI-YEAR PHASED PROGRAM OF SEISMIC IMPROVEMENTS WHEN THE IMPROVEMENTS ARE PRE-DESIGNED AND AN IMPROVEMENT/IMPLEMENTATION PLAN IS APPROVED BY THE BUILDING SAFETY DIRECTOR. THE MAXIMUM TOTAL TIME ALLOWED FOR COMPLETION OF PHASED IMPROVEMENTS SHALL BE TEN YEARS. SECTION 9.645

BUILDING PERMIT APPLICATIONS TO IMPROVE THE SEISMIC CAPABILITY OF A BUILDING SHALL NOT TRIGGER: ACCESSIBILITY IMPROVEMENTS SO LONG AS THE SEISMIC IMPROVEMENT DOES NOT LESSEN ACCESSIBILITY. FIRE LIFE SAFETY IMPROVEMENTS SO LONG AS THE SEISMIC IMPROVEMENT DOES NOT LESSON THE BUILDING S FIRE RESISTANCE OR EXITING CAPABILITY. SECTION 9.650

LANDSCAPE IMPROVEMENTS REQUIRED BY THE LAND DEVELOPMENT CODE CHAPTER 10. STREET TREE IMPROVEMENTS REQUIRED BY THE LAND DEVELOPMENTS CODE. CONFORMANCE WITH THESE INTERIM REGULATIONS MAY NOT EXEMPT BUILDINGS FROM FUTURE SEISMIC REQULATIONS. SECTION 9.650

BUILDING PERMIT, PLAN REVIEW AND FIRE LIFE SAFETY REVIEW FEES ARE WAIVED WHEN SUCH FEES TOTAL LESS THEN $2,500, AND REDUCED BY 50% WHEN SUCH FEES WOULD TOTAL $2,500 OR MORE. SECTION 9.655

BECAUSE UNANTICIPATED CIRCUMSTANCES MAY ARISE IN THE ENFORCEMENT OF THESE REQUIREMENTS FOR EXISTING BUILDINGS, CONSIDERATION AS TO THE REASONABLE APPLICATION OF THIS CHAPTER MAY BE ADDRESSED THROUGH THE UNITED APPEAL BOARD. SEE SECTION 2.475 THROUGH 2.481. SECTION 9.655

GUIDELINES FOR STRUCTURAL WORK IN EXISTING BUILDINGS APPLICATION FOR WORK ON EXISTING BUILDING ADDITION with LOAD > 5% on BLDG? No CHANGE OF OCCUPANCY (To higher hazard) OR 20% increase of occupant load? No PERMIT VALUE > $100,000? No URM BLDG. Unreinforced Masonry Bldg? Yes PERMIT VALUE >$15/Sq Ft? No ROOF REPAIR 50% or more of roof covering? No Any new structural elements requiring structural design or are fire-damaged structural elements being replaced? No Any work done to existing structural elements? No NO STRUCTURAL REQUIREMENTS Yes Yes Yes Yes Yes Yes Yes Upgrade building to UBC.1994 Upgrade building to UBC.1994 FEMA 178 EVALUATION REHABILITATE, CONFORM TO FEMA 178, appendix C ATTACH WALLS TO ROOF structure and BRACE PARAPETS as needed per FEMA 178, appendix c New elements conform to UBC.1994 Does work cause existing element to become overloaded? (Strength and / or stiffness) No Element can be modified without conforming to code for new work Yes Element must be improved to UBC.1994