PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

VSM/55600/N2, Hollow piston rod cylinder Magnetic piston, double acting

F64G - Olympian Plus Plug-In System General purpose filter

M/44000/M LINTRA rodless cylinders Double acting, magnetic piston

RA/28000;.../M, RA/28300;.../M Pneumatic cylinder, ISO Non-magnetic & magnetic piston, single acting Ø mm

Field case for temperature transmitter Model TIF11

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Type Type 2000 Transducers. I/P & E/P Transducers

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Diaphragm pressure gauge

DM/..., DC/95000, DM/..., DC/96000

ACCESSORIES LS/520, LC/520 Heavy duty non-return valves 1/ LT1000 Block form flow regulators (uni-directional) 1/8 & 1/4

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)

Thermophil INFRAsmart R 300 / R 301 / R 302

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

QGO Oxygen Sensor. Building Technologies HVAC Products

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

Magnetic float switch For vertical installation Model FLS for nuclear power plants

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

SITRANS P measuring instruments for pressure

4-Beam-Turbidity Meter ITM-4

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables

SELECTION GUIDE Appearance Sensing distance Operation Mode Connector Shape example (M8) Outer diameter (Ferrous material only) Wiring Output Output no

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Flow Rate Transmitters/ Flow Switches

Bedhead Service Systems. Instructions for Use. July 2016 ASF-18 (0)

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

Miniature High Power Relay SRRHN/SRP

Flow measurement of Liquids and Gases

new Saturno LED - suspension

Mechatronic pressure measurement. Applications. Special features. Description

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

DRUM MOTOR 220M-H 216.0Ø 0.37kW - 5.5kW, with steel helical gearbox

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. One-line aggregate GEI-B. Use:

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on

Miniature I/P, E/P Transducer

Pressure transducers DMU 02 Vario (flush)

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

Reference thermometer Model CTP5000

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

Over 120 years Condor

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Liquid level switch BW 17

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

VMiniature Basic Switch

CAPACITIVE LEVEL METERS CLM 36

min. 50min. 65min. PIT / P3 / P4 Ø

INSTALLATION INSTRUCTION IM 317 E

Visual Level Indicators VLI

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY IECEx BKI Page 1 of 8

Short Stroke Cylinders ISO Bores from 12 to 100 mm

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Differential pressure

D Issue E. Instruction Manual. Pirani Vacuum Gauges (For use with 500, 1000, 1700, 2000 and 4000)

Product overview Product overview

Submersible Borehole Pump. Ixo N. Type Series Booklet

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

Bushing diameter 16 mm, 19 mm or 22 mm. Easy to clean metal surface. Very long life expectancy. Ring or dot illumination. ➀ One-piece bushing

Switch Disconnectors with Fuses

ALUBOX Series Junction boxes in IP66 aluminium alloy

Diaphragm pressure gauge per EN 837-3,

PERFORMANCE SPECIFICATION SHEET

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / /

Ex d. Cooling fins. 4 Joule shock resistant borosilicate glass globe Internal connection terminal box. Stainless steel protective guard A.14 ED.

Flow Measurement SITRANS F M

Instruction Manual Resistance Thermometers for Assignment in Explosion-hazardous Areas TW8# # # # # # # # #

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

Continuous Level Sensor CONDURIX 31.1

PYROS. Código: FT-PY01-I Revisión: 1 1. TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white REFLECTOR

Unloading Valve Series R4U

PRA/862000/M, IVAC Industrial cylinder Magnetic piston, double acting

General Specifications

MODEL CA-72 SERIES ACCELERATION TRANSDUCER INSTRUCTION MANUAL

Focus on Wind Turbines LINAK.COM/TECHLINE WIND-AUTOMATION.COM

Capacitive level meter CLM 36

DRUM MOTOR 138LS 138.5Ø 0.10kW kW, with steel helical gearbox

HS h e n EU omplia t 2002 / 9 5 / C

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

HS-429 Vibration Trip Manual

PRODUCT RANGE CABLE GLANDS

Level Switch. Series. instrumentation for fluids LC40. Instructions Manual

Transcription:

Allfluid pressure switches electromechanical actuated -... 63 bar, G/2 For Ex zones and 2 (gases) as well as Ex zones 2 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector M20 x,5 Robust metal housing in weather-resisting version Technical features Medium: For neutral, non-inflammable gases and fluids Operation: Softseal piston Stainless steel bellow Fluid/Ambient temperature: -0... +75 C (+4... 67 F) Air supply must be dry enough to avoid ice formation at temperatures below +2 C (+35 F) Switching pressure difference: Optional: fixed or adjustable Repeatability: ±% of final value (depending on regulating pressure) Microswitch: With gold plated contacts Degree of protection (acc. to DIN 40050): IP65 Mounting position: Optional Shock-/vibrations (to avoid if possible): 4 g max. (sinusoidal) / 5 Hz max.. Sealing: 0-7 mbar l s - Pulsation: Not permitted Switching cycles: 20/min. max. Material Housing: Aluminium diecast Sensor: Brass or Stainless steel Sealing: Stainless steel-bellows 20D Allfluid ATEX - fixed switching pressure difference Symbol Operating Over pressure Switching pressure difference (typical) Pressure Weight Sensor Model pressure*) *2) Lower range Upper range sensor material (kg) -... 0 0 0,20 0,23.4404, B 8405 -... 0 0,20 0,25.4404, B 84025 -... 2,5 0 0, 0,26.4404, B 84045 0,05... 0 0,6 0,8.4404, B 845 0...,6 0 0,6 0,20.4404, B 845 0,5... 4 20 0,50 0,55.4404, B 8445 0,5... 6 20 0,60 0,70.4404, B 8455 0,5... 0 20 0,70 0,90.4404, B 8465... 6 50,00,40.4404, F 8475... 25 50,30,80.4404, F 8485 5... 63 50 2,00 5,00.4404, H 8495 20D Allfluid ATEX - adjustable switching pressure difference Symbol Operating Over pressure Switching pressure difference (typical) Pressure Weight Sensor Model pressure*) *2) Lower range Upper range sensor minimal maximal material (kg) -... 0 0 0,9 0,25 0,80.4404, B 8505 -... 0 0,20 0,30,00.4404, B 85025 -... 2,5 0 0,20 0,28 2,50.4404, B 85045 0,05... 0 0,6 0,8 0,80.4404, B 855 0...,6 0 0,0 0,6,00.4404, B 855 0,... 2,5 0 0,8 0, 2,00.4404, B 8535 0,5... 4 20 0,50 0,60 2,50.4404, B 8545 0,5... 6 20 0,60 0,70 5,00.4404, B 8555 0,5... 0 20 0,70 0,90 8,00.4404, B 8565... 6 50,60,90,00.4404, F 8575... 25 50,60 2,20 20,00.4404, F 8585 5... 63 50 2,00 5,00 20,00.4404, H 8595 *) Atmospheric air pressure. *2) Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure / Our policy is one of continued research and development. We therefore reserve the right to amend, N/en/en 5..23.0

Option selector 8 5 Switching pressure difference Substitute Adjustable 0 Fixed Accessories Switching pressure range Substitute -... 0 0 -... 02 -... 2,5 04 0,05... 0...,6 0,... 2,5 3* 0,5... 4 4 0,5... 6 5 0,5... 0 6... 6 7... 25 8 5... 63 9 *only for adjustable switching pressure difference Brackets Surge damper Pressure port reducing nipple 0574772 (Steel) 0553258 (G/4, Stainless steel 4505, AISI 303/304 S) 055383 (G/2 & /2 NPT, Stainless steel 4505, AISI 303/304 S) 0553908 (Stainless steel) 0574773 (G/4, Brass/Steel) 0550083 (G/4A... G/2A, Stainless steel 4505, AISI 303/304 S) 0574765 (G/4 /4 NPT, Brass) N/en/en 5..23.02 Our policy is one of continued research and development. We therefore reserve the right to amend, /

Switching capacity Commutator with gold plated contacts Load level Current type Load type*2) U min [V] Standard *3) (e.g. contractors,solenoids) Minor *4) (e.g. electronic circuits) Max. permanent current Imax [A] at U [V] [V] * 30 48 60 5 250 Contact life AC ohmic 0, 0, 0, 0, 0, 2 x 0 5 Switching cycles AC cos j 0,7 3 3 3 3 3 ohmic, L/R 0 ms 5 3,2 0,5 AC ohmic, 5 *5) 0, 2 x 0 5 Switching cycles 0,8 0,35 0,4 0,05 L/R 0 ms 5 *5) 0, 0,0 - - - Reference number: 20/min, Reference temperature: +20 C. Spark quenching with diode with and inductive load: Imax =,5 x Imax of table; Imin = [ma] Creepage and air paths correspond to insulation group B according to VDE Reg. 00 (except contact clearance of microswitch). *) Higher currents (5 A max) will cause a reduction of the durability of the micro-switch contacts. Futhermore additional measuements has to be taken to fulfil the EMV regulation 2004/08/EG by the manufacturer *2) Spark quenching/overload protection will be necessary using inductive loads. *3) Gold-plating not required as it would decay. Max. perm. in-rush current (ca. 30 ms) I AC ein = max. 5A. *4) Gold-plating required (will not decay). *5) Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions. Spark quenching with voltage. Diode D in parallel to inductive load. Observance of correct polarity (positive pole to cathode). Dimensioning specifications for quenching diode: Rated voltage at diode: UD,4 x Us Rated current at diode: IN ILast Selection of a quick switching diode (recovery time trr 200 ms). 2. RC link in parallel to load in parallel to switching contact. Suited for and AC voltage. Dimensioning principles: R in W 0,2 x RLast in W C in [µf] ILast in [A] ~ + U (AC) d.c (a.c.) p RL ) 2) D R C ~ - Schaltfunktion p 2 3 Plug DIN EN 7530-803, form A Microswitch SPDT Terminals - 3: Contacts close on rising pressure. Terminals - 2: Contacts open on rising pressure. / Our policy is one of continued research and development. We therefore reserve the right to amend, N/en/en 5..23.03

Dimensions ~ 9 ( 2) 5,5 ø 5-8 5,8 04 Dimensions shown in mm Projection/First angle 8 70 5 44 9 M4 x 0 deep Connector M20 x,5 acc. to Ex e (ATEX), MS nickel-plated for cable Ø 5 to 8 mm (Type: 058889) ca. 27 M 20 x,5 6 ø 5-8 Sensor combination Operating pressure Sensortype range Code 0 B 02 B 04 B B B 3 B 4 B 5 B 6 B 7 F 8 F 9 H Sensortype F+H Sensortype B 25 20 H H ø 6 25 20 ø B ø B ø 6 Sensortype H B B 75 42 32 F 37 32 4 H 53 37 32 N/en/en 5..23.04 Our policy is one of continued research and development. We therefore reserve the right to amend, /

Surge damper Type: 0553258, 0574773 Type: 055894 G /4 Dimensions shown in mm Projection/First angle 46 34 27 45 ø 2,5 G /4 Ø 6 Pressure port/reducing nipple Type: 055383 Type: 0550083 Type: 0574765 G/4 G /4 27 /2 NPT,5,5 /4 NPT ø 20 6,5 30 Brackets Type: 0574772, 0553908 4 9 04 4 3 5 20 5,8 8 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical features. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. / Our policy is one of continued research and development. We therefore reserve the right to amend, N/en/en 5..23.05