Legacy Home Inspections

Similar documents
,Home Inspection Report

Bill Ostoyic Building Inspection Report XXXXXXX XXXXX XXXXX, Fl. Licensed and Insured

Building Inspection Report

Inspection Report. Property Address:

Alabama Home Inspections

A1-Inspections. Building Inspection Report. (Div of Canada Inc.) Inspection Date: Prepared For: Report Sample

The Standards of Practice

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

The Inspector. Property Inspection Report

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

component was performing its intended function; installation and condition were appropriate for age and use.

Report. Inspection Date: 01/01/2000. Prepared For: John Q. Public. Prepared By: A1 Certified Home Inspections. Lake City, FL 32024

New Jersey Home Inspection - Standards of Practice

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011

Home Inspection Report

2002 CAPHI (BC) Apartment Style Condominium Standards of Practice

Madison's Home Inspections

3D Home Improvement and Inspection Services, Inc

1234 Main St. Buyer Name. Table of Contents

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017

Inspection Report. 1 of 8

WEST MICHIGAN HOME INSPECTORS LLC 3134 Chamberlain SE Grand Rapids MI

Building Inspection Report

N.J.A.C. 13: NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2015 by the New Jersey Office of Administrative Law

The Home Doctor, Inc.

HOME INSPECTION REPORT Prarie Circle

Home Condition Checklist

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012

Property Inspection Checklist

REPORT CHECKLIST SUPPLEMENT

1234 Main St Denver CO 80210

All Pro Home Inspection. Home Report South Your Town

Pre-Listing Home Inspection Checklist

Advanced Home Inspections

All Pro Home Inspection. Home Report North Your Town

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012

CONNECTICUT HOME INSPECTION LICENSING BOARD Department of Consumer Protection 165 Capitol Avenue, Hartford, CT 06106

Total Home Inspection Checklist

TML Home Inspectors, Inc.

J & M Solutions, LLC

InterNACHI Home Inspection Report Checklist

Mississippi Home Inspector Regulatory Board Standards of Practice and Code of Ethics

1st Defense Home Inspections, LLC

SAMPLE Property Inspection Report

ASHI STANDARD OF PRACTICE FOR HOME INSPECTIONS

UP AND UP HOME INSPECTIONS

The following is the Standards of Practice (SOP) for Home Inspectors required by the state of Florida.

Accurate Inspections Inc. Property Inspection Report

Inspection Services of the Treasure Coast

Friendly Inspection Services

Inspect Hawaii. Property Inspection Report

HOME INSPECTOR MINIMUM STANDARDS OF PRACTICE. A. In this chapter, the following terms have the meaning indicated.

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6

PLYMOUTH CREEK HOME OWNERS ASSOCIATION

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

Home Inspection Report

Hogue Home Inspections

9) Home Inspection: As defined in Section 1-10 of the Act.

TITLE 68: PROFESSIONS AND OCCUPATIONS CHAPTER VIII: DEPARTMENT OF FINANCIAL AND PROFESSIONAL REGULATION

Section Standards of Practice. a) The following are terms commonly used in the writing of home inspection reports.

Page 3 of 12. Inspected Describe. Explained. Health & Safety. Maj. Def. Examiner Notes STRUCTURE N/A. Financial Impact. Impact.

Property Inspection Report

A Summary of the Basic Duties of Maintenance, Repair and Replacement for CARRIAGE PARK CONDOMINIUM ASSOCIATION

SOUTH CAROLINA HOME INSPECTOR STANDARDS OF PRACTICE

Calidad Home Inspection Colleyville, TX (817) /

2002 CAPHI (BC) Townhouse Standards of Practice Page 1

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY

Home. Safe. Home. home inspection report

JBR Property Inspections

Building Inspection Report

1623 Carol Street Downers Grove, Illinois Inspection Report for Property at: Private Home Inspection for:

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

6954 Lakeside Dr. Property Inspection Report. - Provided by First Class Property Inspections, LLC -

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY

Property Inspection Report

FINEGAN INSPECTION SERVICES, INC.

GENERAL INFORMATION BUILDING INFORMATION ACRONYM RATING DEFINITIONS

Property Inspection Report

Walnut Creek Mutual Seventy

Country Village Maintenance Responsibility Guidelines BUILDING - EXTERIORS AND INTERIORS

Home Inspection Checklist

Cheshire, CT. By: A.M. Napolitano, LLC. Project Manager: Carolyne Sakonchick Ext. 323

Safety Money Repair Maintenance Evaluate Monitor Comment

Rental Inspection Checklist

Capstone Inspection Services LLC

Prepared for the Sole and Exclusive Use of: John Client Inspector: Hal Leary (Home Inspection Registration # HI-0524) Assistant: Jennifer Leary

Friendly Inspection Services

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

SC Standards Of Practice for Home Inspectors

Tru-Quest Home Inspection

Sample Home Inspection

Alatech Home Inspection Service

Report Page 1 of 23 12/30/2013 Tri-City Home Inspections James Eddy ID:

Weaver Home Inspections, LLC 181 Chase Rd. Columbus, Oh Home Inspection Report

Property Inspection Report

Jardine Place, Toronto, Ontario

Transcription:

Cover Page Legacy Home Inspections Home Inspection Report 66215 Inspection prepared for: Robert & Patricia Smith Date of Inspection: 4/1/2016 Inspector: Robert Ladd 7922 Darnell Lane, Lenexa, KS 66215 Phone: 913-484-4157 Email: rhladd@gmail.com legacyhomeinspections-kc.com

For your convenience, the following conventions have ben used in this report. Major Concern: a system or component that is unsafe and in need of prompt attention. Safety Issue: denotes a condition that is unsafe and in need of prompt attention. Repair: denotes a system or component which is missing or which needs corrective action to assure proper and reliable function. Discretionary Improvement: denotes improvements which are recommended but not required. Monitor: denotes a system or component needing further investigation and/or monitoring in order to determine if repairs are necessary. Deferred Cost: denotes those items that have reached or are reaching their normal life expectancy or show indications that they may require replacement within the net five (5) years..please note that those observations listed under "Discretionary Improvements" are not essential repairs, but represent logical long-term improvements. Page 1 of 25

Report Summary Structure Page 6 Columns/Beams/Jo ist Report Summary Repair: Noted roof bracing at front side of home (as seen in attic) were miscut and offered little support. Recommend replacing braces. Roofing Page 7 Downspouts Repair: Downspouts should discharge water 24-36" from foundation to help prevent foundation damage and moisture intrusion. Recommend adding plastic extensions or French drains (underground extensions). Page 7 Chimneys Repair: Noted several areas of spalling (flaking) on the chimney. This is a common condition of masonry chimneys. Recommend repair. Repair: Noted the concrete chimney cap was damaged/cracked. Recommend repair/sealing. Exterior Page 9 Porch Repair: Noted a small void underneath front porch. Recommend filling void with concrete or chat to prevent porch separation and prevent animal intrusion. Page 9 Deck Discretionary Improvement: The deck should be painted or stained to improve durability. Repair: The right handrail is loose. Recommend Repairing. Page 10 Siding/Trim Discretionary Improvement: Noted minor flaking paint on front and right side of home. Recommend scraping/painting as weather allows. Repair: Noted wood rot on fascia board on back side of homeat roof level. Recommend replacement. Page 10 Garage Safety Issue: The garage door's auto reverse was unresponsive. When the garage door meets 5 PSI of resistance it should reverse its course. This problem can be easily corrected by adjusting the tension screws on the garage door openers main box. Page 10 Fencing Discretionary Improvement: Fence should be stained or painted to protect from moisture damage. Discretionary Improvement: Fence should be stained or painted to protect from moisture damage. Repair: Noted minor damage to fence. Repair/replace as needed. Repair: Noted minor wood rot on perimeter fence. Recommend repair. Page 11 Landscaping Repair: Shrubs should be cut back 6-8" inches away from wall to prevent siding damage. Page 11 Pests Repair: Recommend moving firewood away from house at least 30 feet, as it invites termites. Electrical Page 13 Outlets Observation: Noted all first and second floor bathroom GFIs reset in garage. Repair: The installation of ground fault circuit interrupter (GFCI) devices is advisable in areas within six feet of running water. Recommend installing in kitchen. Page 2 of 25

Page 13 Lights Repair: Observed an inoperative light in middle back bedroom. Recommend repair/replace burned out bulb. Cooling/Heat Pumps Page 16 Central Air Conditioning Monitor: Was unable to test the air conditioner due to temperature constraints. If concerned about the condition of the unit, request bill of service from homeowner. Both the furnace and AC should be serviced annually. Repair: Recommend cleaning leaves/grass/dust from external fins of AC unit. Repair: Noted gap in seal where refrigerant line enters house. Recommend enhancing seal. Insulation/Ventilation Page 17 Attic/Roof Repair: Recommend removing bird from attic space above front door. Repair: Recommend insulating access panel to attic in linen closet. Page 17 Radon Mitigation System Monitor: Recommend periodic monitoring of radon mitigation system. When viewing vacuum monitor installed on PVC pipe in basement. An uneven liquid level indicates the system is operative. Plumbing Page 19 Sinks Repair: Lift rod (controls the stopper) at right sink in master bathroom was inoperative. Recommend reconnecting lubricating. Page 19 Toilets Repair: Toilet tank in the basement bath is loose. Recommend tightening. Interior Page 21 Walls Monitor: Observed moderate drywall cracking in entry hall and left bedroom. This type of cracking is typical with drywall construction and is not usually a structural deficiency. Monitor for further damage and repair if necessary. Page 21 Ceiling Finishes Monitor: Noted a moisture stain in the hallway ceiling. The stain was dry at the time of inspection and does not appear to have occurred recently. Recommend conferring with current owner for details and monitor for spread. Page 22 Windows Repair: Noted window in middle front bedroom with broken seal, resulting in interior staining of double-pane glass. Recommend replacement of glass and having a window specialist evaluate all windows in home for similar defects. Page 22 Doors Repair: Noted a door to the basement, linen closet, hall door to left bedroom, and basement closet door that doesn't latch. Recommend re-hanging the doors or aligning strike plate so that doors latch properly. Discretionary Improvement: Noted damaged door jamb at front door. Repair as needed. Repair: A door to the toilet area in master bath, hall door to master bedroom and hall door to middle front bedroom did not close/open properly. At time of inspection, door was sticking at the top. Recommend rehanging door or shaving. Fireplaces/Wood Stoves Page 3 of 25

Page 25 Fireplace(s) Repair: The fireplace chimney should be inspected and cleaned prior to closing, if not done so in the past 36 months. Confer with owner. Page 4 of 25

Legacy Home Inspections The Scope of the Inspection All components designated for inspection in the InterNACHI Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report. It is the goal of the inspection to put a home buyer in a better position to make a buying decision. Not all improvements will be identified during the inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind. Please refer to the pre-inspection contract for a full explanation of the scope of the inspection. Page 5 of 25

Description of Structure Structure Foundation: Poured Concrete Basement Configuration Slab on Grade Columns: Steel Floor Structure: Wood Joist Wall Structure: Wood Frame Roof Structure: Rafters Oriented Strand Board Sheathing Roof Structure: Rafters Spaced-plank Positive Attributes The construction of the home is high quality. The materials and workmanship, where visible, are above average. General Comments No major defects were observed in the accessible structural components of the house. No repair to structural components is necessary as this time.. Some typical repairs are needed. Columns/Beams/Joist Observations: Repair: Noted roof bracing at front side of home (as seen in attic) were miscut and offered little support. Recommend replacing braces. Roof braces miscut and loose Limitations of Structure Inspection Roof braces miscut and loose As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * Structural components concealed behind finished surfaces could not be inspected. * Only a representative sampling of visible structural components were inspected. * Furniture and/or storage restricted access to some structural components. * Engineering or architectural services such as calculation of structural capacities, adequacy, or integrity are not part of a home inspection. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 6 of 25

Description of Roofing Roofing Roof Covering: Asphalt Shingle Roof Flashing: Metal Chimney(s): Masonry Roof Drainage System: Aluminum - Downspouts discharge above grade and below grade Skylights: Curb-Type Method of Inspection: Walked on roof Positive Attributes The roof coverings are newer and appear to be in generally good condition. The installation of the roofing materials has been performed in a professional manner. The quality of the installation is above average. Better than average quality materials have been employed as roof coverings. The steep pitch of the roof should result in a longer than normal life expectancy for roof coverings. Roof flashing details appear to be in good order. The gutters are clean General Comments Some minor repairs are needed on features other than coverings. Downspouts Repair: Downspouts should discharge water 24-36" from foundation to help prevent foundation damage and moisture intrusion. Recommend adding plastic extensions or French drains (underground extensions). Chimneys Extend downspout Repair: Noted several areas of spalling (flaking) on the chimney. This is a common condition of masonry chimneys. Recommend repair. Repair: Noted the concrete chimney cap was damaged/cracked. Recommend repair/sealing. Replace mortar Damaged chimney cap Replace mortar Page 7 of 25

Limitations of Roofing Inspection As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * Not all of the underside of the roof sheathing is inspected for evidence of leaks. * Evidence of prior leaks may be disguised by interior finishes. * Estimates of remaining roof life are approximations only and do not preclude the possibility of leakage. Leakage can develop at any time and may depend on rain intensity, wind direction, ice build up, and other factors. * Antennae, chimney/flue interiors which are not readily accessible are not inspected and could require repair. * Roof inspection may be limited by access, condition, weather, or other safety concerns. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 8 of 25

Description of Exterior Exterior Wall Covering: Wood Siding Brick Eaves, Soffits, And Fascias: Wood Exterior Doors: Solid Wood Metal Window/Door Frames and Trim: Aluminum Wood Entry Driveways: Concrete Entry Walkways and Patios: Concrete Porches, Decks, Steps, Railings: Concrete Wood Overhead Garage Door(s): Steel Automatic Opener Installed Surface Drainage: Level Grade Fencing: Wood Positive Attributes A portion of the exterior siding that has been installed on the house is relatively low maintenance. The lot drainage was good, conducting surface water away from the building. The wood window frames are in generally good condition. The driveway and walkways are in good condition General Comments The exterior of the home is in generally good condition. Porch Repair: Noted a small void underneath front porch. Recommend filling void with concrete or chat to prevent porch separation and prevent animal intrusion. Deck Small void under front porch Small void under front porch Discretionary Improvement: The deck should be painted or stained to improve durability. Repair: The right handrail is loose. Recommend Repairing. Paint/stain deck Loose handrail Page 9 of 25

Siding/Trim Discretionary Improvement: Noted minor flaking paint on front and right side of home. Recommend scraping/painting as weather allows. Repair: Noted wood rot on fascia board on back side of homeat roof level. Recommend replacement. Flaking paint at front of home Garage Flaking paint on right side of home Damaged fascia board on roof Safety Issue: The garage door's auto reverse was unresponsive. When the garage door meets 5 PSI of resistance it should reverse its course. This problem can be easily corrected by adjusting the tension screws on the garage door openers main box. Fencing Adjust down force here Discretionary Improvement: Fence should be stained or painted to protect from moisture damage. Discretionary Improvement: Fence should be stained or painted to protect from moisture damage. Repair: Noted minor damage to fence. Repair/replace as needed. Repair: Noted minor wood rot on perimeter fence. Recommend repair. Paint/stain fencing Damaged fencing at left side of yard Damaged fencing at back side Page 10 of 25

Damaged fencing at back side Damaged fencing at back side Damaged fencing at back side Landscaping Repair: Shrubs should be cut back 6-8" inches away from wall to prevent siding damage. Cut back bushes Cut back bushes Pests Repair: Recommend moving firewood away from house at least 30 feet, as it invites termites. Move firewood Page 11 of 25

Limitations of Interior Inspection As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * A representative sample of exterior components was inspected rather than every occurrence of components. * The inspection does not include an assessment of geological, geotechnical, or hydrological conditions, or environmental hazards. * Screening, shutters, awnings, or similar seasonal accessories, fences, recreational facilities, outbuildings, seawalls, break-walls, docks, erosion control and earth stabilization measures are not inspected unless specifically agreed upon and documented in this report. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 12 of 25

Description of Electrical Electrical Size of Electrical Service: 120/240 Volt Main Service - Service Size: 200 Amps Service Drop: Underground Service Entrance Conductors: Aluminum Service Equipment & Main Disconnects: Main Service Rating 200 Amps Breakers Service Grounding: Aluminum-Bare Service Panel & Overcurrent Protection: Panel Rating: 200 Amps Distribution Wiring: Copper Wiring Method: Non-Metallic Cable "Romex" Switches and Receptacles: Grounded Ground Fault Circuit Interrupters: Bathrooms Garage Smoke Detectors: Present Positive Attributes The size of the electrical service is sufficient for typical single family needs. The electrical panel is well arranged and all fuses/breakers are properly sized. Generally speaking, the electrical system is in good order. The distribution of electricity within the home is good General Comments Inspection of the electrical system revealed the need for typical, minor repairs. Outlets Observation: Noted all first and second floor bathroom GFIs reset in garage. Repair: The installation of ground fault circuit interrupter (GFCI) devices is advisable in areas within six feet of running water. Recommend installing in kitchen. Lights Bathroom GFIs reset in garage Install GFIs in kitchen on both sides of sink Repair: Observed an inoperative light in middle back bedroom. Recommend repair/replace burned out bulb. Page 13 of 25

Limitations of Electrical Inspection Missing light in middle back bedroom As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * Electrical components concealed behind finished surfaces are not inspected. * Only a representative sampling of outlets and light fixtures were tested. * Furniture and/or storage may prevent access to some electrical components which may no be inspected. * The inspection does not include remote control devices, alarm systems and components, low voltage wiring systems and components, ancillary wiring systems and other components which are not part of the primary electrical power distribution system. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 14 of 25

Description of Heating Heating Energy Source: Gas Heating System Type: Forced Air Furnace MFG Name: Lennox Model Number: ML180UH090P48B-01 Serial Number: 5912F09757 MFG. Date: 2012 Vents, Flues, Chimney(s): Metal-Single Wall Masonry-Lined Heat Distribution Method: Ductwork Positive Attributes The heating system is in generally good condition. Heat distribution within the home is adequate General Comments The heating system shows no visible evidence of major defects. No repairs of the heating system are necessary at this time Limitations of Heating Inspection As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * The adequacy of heat supply or distribution balance is not inspected. * The interior of flues or chimneys which are not readily accessible are not inspected. * The furnace heat exchanger, humidifier, and electronic air filters are not inspected. * Solar space heating equipment/systems are not inspected. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 15 of 25

Cooling/Heat Pumps Description of Cooling/Heat Pumps Energy Source: Electricity 240 Volt Power Supply Central System Type: Air Cooled Central Air Conditioning Manufacturer: Goodman Model Number: CKL36-1L Serial Number: 0501030209 MFG. Date: 2005 Other Components: Whole House Fan Positive Attributes The capacity and configurating of the system should be sufficient for the home General Comments The system shows no visible evidence of major defects. Due to temperature constraints, was not able to fully inspect the cooling system. When outside temperature is below 65 degrees, substantial damage can be done to refrigerant lines. Some minor repairs are needed. Central Air Conditioning Monitor: Was unable to test the air conditioner due to temperature constraints. If concerned about the condition of the unit, request bill of service from homeowner. Both the furnace and AC should be serviced annually. Repair: Recommend cleaning leaves/grass/dust from external fins of AC unit. Repair: Noted gap in seal where refrigerant line enters house. Recommend enhancing seal. Clean grass from AC unit Limitations of Cooling/Heat Pumps Inspection Seal gap As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * Windows mounted air conditioning units are not inspected. * The cooling supply adequacy or distribution balance are not inspected. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 16 of 25

Insulation/Ventilation Description of Insulation/Ventilation Attic Insulation: R30 Fiberglass in Main Attic Exterior Wall Insulation: R12 Fiberglass in Original Walls Not Visible Basement Wall Insulation: R8 Fiberglass on portion of walls in basement Not Visible Roof Ventilation: Soffit Vents Roof Vents Exhaust Fan/Vent Locations: Bathroom(s) Kitchen Dryer Positive Attributes This is a well insulated home. General Comments There are minor issues with the ventilation and/or insulation. Attic/Roof Repair: Recommend removing bird from attic space above front door. Repair: Recommend insulating access panel to attic in linen closet. Bird located in space above front door Radon Mitigation System Insulate access panel to attic Observations: Monitor: Recommend periodic monitoring of radon mitigation system. When viewing vacuum monitor installed on PVC pipe in basement. An uneven liquid level indicates the system is operative. Radon vacuum monitor in basement Page 17 of 25

Limitations of Insulation/Ventilation Inspection As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * Insulation/ventilation type and levels in concealed areas are not inspected. Insulation and vapor barriers are not disturbed and no destructive tests (such as cutting openings in walls to look for insulation) are performed. * Potentially hazardous materials such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI) cannot be positively identified without a detailed inspection and laboratory analysis. * An analysis of indoor air quality is not part of our inspection unless explicitly contracted for and discussed in this or a separate report. * Any estimates of insulation R-values or depths are rough average values. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 18 of 25

Description of Plumbing Plumbing Water Supply Source: Public Water Supply Service Pipe to House: Copper Main Water Valve Location: Front Wall of Basement Interior Supply Piping: Copper Water System: Public Sewer System Drain, Waste, & Vent Piping: Plastic Cast Iron Water Heater: Gas Approximate Capacity (in gallons): 50 Manufacturer: State Model Number: GS650BRT 400 Serial Number: 1533A018328 MFG. Date: 2015 Positive Attributes The plumbing system is in generally good condition. The piping system within the home, for both supply and waste, is a good quality system. The water pressure supplied to the fixtures is above average. The plumbing fixtures appear to have been well-maintained. Some of the plumbing fixtures within the home have been upgraded General Comments The plumbing system requires some typical minor improvements. Sinks Repair: Lift rod (controls the stopper) at right sink in master bathroom was inoperative. Recommend reconnecting lubricating. Toilets Inoperative lift rod in master bath Repair: Toilet tank in the basement bath is loose. Recommend tightening. Loose tank in basement bath Page 19 of 25

Limitations of Plumbing Inspections As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * Portions of the plumbing system concealed by finishes and/or storage (below sinks, etc.), below structure, or beneath the ground surface are not inspected. * Water quantity and water quality are not tested unless explicitly contracted for nd discussed in this or a separate report. * Clothes washing machine connected are not inspected. * Interiors of flues or chimneys which are not readily accessible are not inspected. * Water conditioning systems, solar water heaters, fire and lawn sprinkler systems, and private waste disposal systems are not inspected unless explicitly contracted for and discussed in this or a separate report. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 20 of 25

Description of Interior Interior Walls and Ceilings: Drywall Floor Surfaces: Carpet Tile Wood Concrete Window Type: Double/Single Hung Fixed Pane Double Glazed Doors: Wood Solid Core Doors: Wood Hollow Core Positive Attributes The interior finishes of the home are in above average condition. General Comments Interior Finishes: On the whole, the interior finishes of the home are in above average condition. Typical minor flaws were observed in some areas. Windows and Doors: The majority of the doors and windows are good quality. Floors: The floors of the home are relatively level and walls are relatively plumb. Walls Monitor: Observed moderate drywall cracking in entry hall and left bedroom. This type of cracking is typical with drywall construction and is not usually a structural deficiency. Monitor for further damage and repair if necessary. Ceiling Finishes Drywall crack in hallway Monitor: Noted a moisture stain in the hallway ceiling. The stain was dry at the time of inspection and does not appear to have occurred recently. Recommend conferring with current owner for details and monitor for spread. Water stain in hallway Page 21 of 25

Windows Repair: Noted window in middle front bedroom with broken seal, resulting in interior staining of double-pane glass. Recommend replacement of glass and having a window specialist evaluate all windows in home for similar defects. Doors Window in middle front bedroom with broken seal Repair: Noted a door to the basement, linen closet, hall door to left bedroom, and basement closet door that doesn't latch. Recommend re-hanging the doors or aligning strike plate so that doors latch properly. Discretionary Improvement: Noted damaged door jamb at front door. Repair as needed. Repair: A door to the toilet area in master bath, hall door to master bedroom and hall door to middle front bedroom did not close/open properly. At time of inspection, door was sticking at the top. Recommend rehanging door or shaving. Basement door won't latch Realign strike plate for doors that won't latch Damaged door jamb Bathroom door sticks at top Hall door to master bedroom sticks at top Hall door to middle front bedroom sticks at top Page 22 of 25

Linen closet door won't latch Bedroom door won't latch Wall in left bedroom Limitations of Interior Inspection Basement closet door won't latch As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * Furniture, storage, appliances and/or wall hanging are not moved to permit inspection and may block defects. * Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments are not inspected. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 23 of 25

Description of Appliances Appliances Appliances Tested: Built-In Electric Oven Electric Cooktop Microwave Oven Dishwasher Garbage Disposal Refrigerator Laundry Facility: 240 Volt Circuit for Dryer Dryer Vented to Building Exterior 120 Volt Circuit for Washer Hot and Cold Water Supply for Washer Other Components Tested: Kitchen Exhaust Fan Door Bell Positive Attributes All appliances that were tested responded satisfactorily.. The kitchen and laundry facilities are well organized. The kitchen and cabinetry is above average quality. The kitchen and cabinetry is average quality. The appliances that have been installed in the kitchen are good quality General Comments No repairs needed at this time. Limitations of Appliances Inspection As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * Thermostats, timers and other specialized features and controls are not tested. * The temperature calibration, functionality of timers, effectiveness, efficiency and overall performances of appliances is outside the scope of this inspection. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 24 of 25

Fireplaces/Wood Stoves Description of Fireplaces/Wood Stoves Fireplaces: Masonry Firebox Vents, Flues, Chimney(s): Masonry Chimney-lined General Comments Some work is needed on either fireplace or its components. Fireplace(s) Repair: The fireplace chimney should be inspected and cleaned prior to closing, if not done so in the past 36 months. Confer with owner. Limitations of Fireplaces/Wood Stoves Inspection As we have discussed and described in your inspection contract, this is a visual inspection limited in scope by (not not restricted to) the following conditions: * The interior of flues or chimneys are not inspected. * Firescreens, fireplace doors, appliance gasket and seals, automatic fuel feed devices, mantles and fireplace surrounds, combustion make-up air devices, and heat distribution assists (gravity or fan assisted) are not inspected. * The inspection does not involve igniting or extinguishing fires nor the determination of draft. * Fireplace inserts, stoves, or firebox contents are not moved. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. Page 25 of 25