RIB PANEL INSTALLATION

Similar documents
Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

TABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB

RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE

EVERSEAM 20 APPLICATION GUIDE

Black s Metals Installation Guide

PIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components

5V and CORRUGATED Accessory Detail Manual

Western States 7/8 Corrugated

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.

ENERGY STAR PARTNER. PBR & R Panel

Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES

Built to Last a Lifetime

PBR & PBU PANELS. Technical/Installation Information

TYPICAL ROOF CONDITION LAYOUT

Central Snap. Condition Details C SNAPDETAILS

CONTOUR CORRUGATED PANEL

Classic Rib Roofing Panels DETAIL MANUAL

Prior to ordering and installing materials, all dimensions should be verified by field measurements.

4572 N Old US 31, Rochester, IN Toll Free: Fax: DETAIL MANUAL. and guide to Ramco Supply products

PROLOK EAVE PROLOK ROOFING PANEL ROOFING NAIL

PBR & PBU PANELS. Technical/Installation Information

Central Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼

Architectural Roof and Wall Products Guide Specifications

SHURLOC 150 STANDARD DETAILS

TATA BLUESCOPE STEEL LIMITED PRODUCT SPECIFICATION LANGUAGE FOR PRE ENGINEERED STEEL BUILDING (BUTLER BUILDING SYSTEM- WITH BR-II ROOF SYSTEM)

Residential Pricing Guide

Central Texas Metal Roofing Supply Co., Inc 36" SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼ NET COVERAGE

TATA BLUESCOPE STEEL LIMITED PRODUCT SPECIFICATION LANGUAGE FOR PRE ENGINEERED STEEL BUILDING (BUTLER BUILDING SYSTEM- WITH MR-24 ROOF SYSTEM)

ABSeam Panel Overview and Installation Instructions

TRIAD CORRUGATED METAL, INC.

Architectural Wall Products Guide Specifications

Central Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH

S BI COM P ON E NT CA T ALOG

a division of NCI Standing Seam Roof Systems

Standing Seam Installation Guide

Architectural Roof and Wall Products Guide Specifications

SECTION PRE-ENGINEERED METAL BUILDING

238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM #

PRODUCT DESCRIPTION ACCESSORIES. Canopies

INSTALLATION MANUAL Heritage Series

CONTINUOUS VENTILATORS

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten

Classic and NB Tile Counter Batten and Batten

Central Texas Metal Roofing Supply Co., Inc SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.

INSTALLATION GUIDE.

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Tile

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION STEEL BUILDING SYSTEMS

Instruction Manual for Installing OutBack Steel-Framed Buildings. Gambrel Buildings

DL-200. Specifications

PBR & PBU Panels. Technical/Installation Information

5V Crimp DESIGN/INSTALLATION INFORMATION

ALLMET CONTINENTAL INSTALLATION GUIDE

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.

Recla Metals RCM INSTALLATION GUIDELINES

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

BARREL VAULT Tile Counter Batten and Batten Installation Guide

SECTION PRE-ENGINEERED WOOD POST FRAME BUILDING SYSTEM. B. Products Supplied But Not Installed Under This Section:

w w w. s a q u l i t y m e ta l s. c o m

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

Light-Metal Roof Edge, Raised

CONSTRUCTION DETAILS HANDBOOK

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

For Metal Roofing Systems Fascia, Mansards,& Soffits

1 1/2" SSR. FABRAL The pursuit of excellence since 1967

2120 SW Poma Drive; Palm City, Florida Phone Fax

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

SSL-175. Specifications

Architectural Roof Products Guide Specifications

ML-150. w w w. s a q u l i t y m e ta l s. c o m. san antonio branch 210 W. Peden San Antonio TX P. (210) F.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION METAL BUILDING SYSTEMS

Proposal for Garage Shell Kit. 25 wide by 35 long Pre-Engineered Building Components. April 19, 2017

Architectural Roof Products Guide Specifications

SECTION STAINLESS STEEL WALL PANELS

GA APPLICATION OF GYPSUM SHEATHING

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

KS SERIES - VERTICAL INSTALLATION

w w w. s a q u l i t y m e ta l s. c o m

2120 SW Poma Drive; Palm City, Florida Phone Fax

Architectural Roof and Wall Products Guide Specifications

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

TRIAD CORRUGATED METAL, INC.

SECTION METAL BUILDING SYSTEMS. A. Section Placement of anchor bolt, leveling plates, and grout.

29 Gauge. Technical/Installation Information

Flat. Ribbed Striated and 1 ½ TCM-Lok Installation Manual

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

StrongSeam SSFF1 Panel

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

Chapter 32 - Garage. June 2015 Garages 32-1

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS

JUNIOR HF Steel Roof Panels

COMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER

Transcription:

GOLDIN METALS, INC. www.goldinmetals.com 12440 SEAWAY ROAD Mailing Address: 14231 SEAWAY ROAD, SUITE 7000 GULFPORT, MS 39503 (228) 896-6216, Ext. 230 FAX (228) 896-4873 4400 PETERS ROAD P.O. BOX 700 HARVEY, LA 70059 (504) 361-3622 (504) 361-3676 FAX 1360 CONCEPTION ST. RD. P.O. BOX 1426 MOBILE, AL 36633 (251) 452-6384 (251) 456-0761 FAX Metal Building Component Manufacturer Steel Service Center RIB PANEL INSTALLATION 112 ZONOLITE STREET LAFAYETTE, LA 70508 (337)314-0069 (337)-314-0098 FAX GOLDINPANEL R-PANEL 36" COVERAGE 36" COVERAGE 9" 9" 9" 9" 5/8" 12" 12" 12" 1-1/ DRAIN FEATURE STORAGE AND HANDLING Prior to installation, store painted, galvalume and galvanized Rib Panels only in a dry place. Do not store outdoors, nor in any indoor area subject to moisture. Stand panels on end and fanned out at the bottom to provide air circulation, or stack flat in piles on blocks or racks to protect bottom panels from ground moisture. In handling all Rib Panels, lift up and do not slide panels when unstacking or the finish coating may be damaged. than one horizontal row of panels, follow these procedures: Temporarily fasten (i.e., at two points not at ends along middle main ribs) panel No. 1 in lower corner. Install panel No. 2 above and endlapping over No. 1. Align both panels with chalkline. Install panel No. 3 next to No. 1, side-lapping over drain feature. Install panel No. 4 above No. 3, sidelapping over No. 2 and end-lapping over No. 3 (see illustration). Check alignment at ridge and eave again. Temporarily fasten all panels; permanently fasten when all panels are in line. ROOFING INSTALLATION Slope: Minimum roof slope for Rib Panel is 3 inches rise per foot. Apply sealant at side and end laps for less slope. Start installing roofing vertically at edge away from prevailing wind. Rib Panel with side lap drain feature may be started from either right or left edge. IMPORTANT: First roofing panel must be plumb to assure straight alignment of entire row of panels. Tip: stretch chalklines between nails driven into ridge and end of each rafter. These lines serve as guidelines to align panels. If roof requires more - 1 - Roofing Installation IMPORTANT: Do not temporarily or permanently fasten drain feature rib of any panel until it is sidelapped by adjacent panel.

Side Lap: 2 inches, with lapping rib completely over drain feature rib. End Laps: Under 4 rise per foot...12 lap 4 rise per foot... 8 lap 5 or more rise per foot... 6 lap Eave: Allow 3 inches minimum overhang. SIDING INSTALLATION Start installing Rib Panel siding vertically at edge away from prevailing wind, starting from either right or left edge. IMPORTANT: First siding panel must be plumb to assure straight alignment of entire row of panels. Tip: Temporarily nail a 2 x 4 or double angle horizontally as a guideline about 3 inches below top of baseboard or foundation. Remove 2 x 4 after siding is permanently fastened. Temporarily fasten first panel at starting edge. Install second panel next to the first, side-lapping over drain feature. Temporarily fasten all panels; permanently fasten when all panels are in line. IMPORTANT: Do not temporarily or permanently fasten drain feature rib of any panel until it is sidelapped by adjacent panel. Prevent all panels from permanently contacting soil. Side Lap: 2 inches, with lapping rib completely over drain feature rib. End Lap: Lap 3 inches panel-over-panel and also over foundation or splashboard. FASTENING DETAIL Drill Screw Fastening: Rib Panel roofing and siding may be installed by use of painted/plated steel drill screws with sealing washers. Fasteners should have corrosion resistance at least equivalent to the expected life of the metallic substrate and the base metal. Selection of suitable long-lasting fasteners to be used rests solely with the buyer. For best results, fasten panels to purlins and girts at each side lap and in all flat areas between ribs. Minimum screw spacing may be at side laps and center flat area only, or a combination of both methods may be used by alternating them at every other purlin. - 2 - METAL FASTENERS Correct Too Loose Too Tight Sealing material slightly visible at edge of metal washer. Assembly is weathertight. Sealing material not visible. Not enough compression to seal properly. PANEL DETAIL R-PANEL SIDE LAP DETAIL PBR-PANEL PANEL DETAIL GOLDINPANEL DRAIN FEATURE 36" COVERAGE 12" 12" 12" Purlin Bearing Leg 36" COVERAGE 9" 9" Metal washer deformed. Sealing material extruded beyond edge of washer. Screw fastening for all intermediate locations Z-purlin, wood purlin, or substructure Screw fastening at eaves, endlaps, and valleys Z-purlin, wood purlin, or substructure Sealant location-roof only Screw fastener w/bonded neoprene washer 1-1/ * Consult Manufacturer for proper type of screw to be used with different types of substructures and panels. 9" Metal stitch screw w/bonded neoprene washer Use 1-1/2 inch long screws at side laps, along nailing strip farthest away from finishing edge of lapping rib (see Illustration A); use 1-1/2 inch or 1 inch long screws at flat areas (see Illustration B). NOTE: All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment. 9" 5/8"

CORRUGATED / 5V CRIMP INSTALLATION Lapping: Side lap 2-1/2 corrugated roofing; two corrugations and siding; one corrugation. Side lap 5V crimp by placing the two crimps of the second sheet directly over the two crimps of the first sheet containing the drain feature. End lap roofing 12 when rise per foot is 3 ; 8 when rise is 4 ; 6 when rise is 5 or more. A. B. At the side lap, the screw is positioned vertically on the crest of the corrugation. All in field of sheet locations are positioned vertically in the valley of every third corrugation. (Diagrams A & B) 5V crimp roofing and siding screw in the flat next to the rib, starting at the side lap. (Diagram C) C. Drain Feature 5V crimp Drain feature should always be on the underside of the lap. INSULATION Insulation material either board, roll, or loose filler type (spray-on type is NOT recommended) should be used with a vapor barrier to reduce condensation on the inside of the Rib Panel roofing and siding in cold weather. Obtain specific recommendations from a qualified engineer. FILLER/SEALER STRIPS AND SEALANTS For best results in making a building weathertight, use formed filler/sealer strips (closures) at roof ridge and eaves. Strips with Rib Panel pattern are available. Butyl rubber sealants are excellent for side-lap sealing. VENTILATION Adequate air ventilation should be provided by means of ridge or rotary ventilators, power operated fans, profile vent gaskets, or other openings to minimize condensation. Obtain specific recommendations from a qualified engineer. TRANSLUCENT FIBERGLASS PANELS Translucent fiberglass panels with the Rib Panel patterns are available for use as skylights and/or windows. CUTTING AND SHEARING Rib Panel is easier to cut from its interior (bottom) side because of its flatter surface. Rib Panel may be cut with a nibbler, snips, or profile shear. - 3 - IMPORTANT: When using a power drill to make screw holes, protect the exterior (top) surface from the hot metal filings, which may become imbedded into the paint surface and eventually rust. Carefully wipe all filings from both surfaces before installation. If these cutting precautions are not taken, permanent rust spots will develop; naval jelly or auto cleaner/wax may be used to clean them, but they cannot be completely removed. NOTICE: Waviness in metal panels, commonly referred to as oil canning, is an inherent characteristic with metal panels. Rib Panel patterns may mitigate this condition, while in flat pan profiles it could be more pronounced. The surface of bare Galvalume and Galvanized will vary in shade and spangle pattern, and such appearances may not be uniform. Under any circumstance, these conditions will not be considered reasons for rejection or claim. SAFETY PRECAUTIONS Gloves should be worn to prevent injury while handling steel panels. Safety glasses should be worn to prevent eye injury when cutting or drilling steel panels with power tools. Use care when walking, sitting, or kneeling on a steel roof to avoid a fall. Steel panels may become slippery when wet. Do not work on steel panels when wet or when climactic conditions are not suitable for safe installation. Do not walk on steel panels that contain oil. Do not walk on skylights.

GOLDINPANEL RESIDENTIAL ROOF & WALL DRAIN FEATURE #1 RIDGE CAP PROFILE VENT EXPANDING UNIVERSAL FOAM CLOSURE #5 GABLE START #2 HIP CAP ROOF JACK CLOSURE STRIP #3 RAKE #3 OUTSIDE CORNER #18 BASE & DRIP #20 HEAD FLASHING #6 RAT GUARD #4 INSIDE CORNER #14 VALLEY #9 EAVE FLASHINGS FLASHINGS #19 JAMB GUTTER OPTIONS #15 VALLEY WITH HOOKS #10 EAVE TRIM #44 EAVE GUTTER #43 EAVE GUTTER #11 EAVE DRIP - 4 -

RESIDENTIAL R SPECIFY PITCH 1. 1 1 4 4 RIDGE CAP SPECIFY PITCH 2. 3. 4. 3 6 1/ 6 1/ 3 HIP CAP RAKE & CORNER INSIDE CORNER 4 2 1/ 5. 1 6. SPECIFY PITCH 7. SPECIFY PITCH 8. 5" 4 1/ 4 1/ GABLE START RAT GUARD GAMBREL FLASHING PEAK FLASHING SPECIFY PITCH 1 3/8" 1 9. 3/8" EAVE FLASHING EAVE FLASHING EAVE DRIP TRANSITION FLASHING 7" 3" 1 1/ SLIDING DOOR HOOD 1 5/8" SPECIFY PITCH 4 1/8" 3" 13. SPECIFY PITCH 14. SPECIFY PITCH 15. 16. 9" 9" VALLEY FLASHING 10. SPECIFY PITCH 3 1/ 5 VALLEY FLASHING WITH HOOKS 11. 8 8 SPECIFY PITCH 3 3 5/8" 4 5 12. SIDEWALL FLASHING SPECIFY PITCH 17. 18. 19. 20. 5" 4 2 3/8" ENDWALL FLASHING BASE & DRIP FLASHING JAMB FLASHING HEAD FLASHING ACTUAL DIMENSIONS MAY VARY CERTAIN RESTRICTIONS APPLY 2 1/ 2 1/ - 5 -

R-PANEL COMMERCIAL ROOF & WALL PBR LAP R PANEL LAP #24 GABLE START #22 EXTENDED RIDGE #23 EXTENDED HIP #26 RAKE #25 SCULPTURED RAKE #21 DIE FORMED RIDGE CAP #29 SKYLIGHT TRIM #26 CORNER #33 BASE & DRIP #34 RAT GUARD #32 HEAD FLASHING #17 ENDWALL FLASHING #28 SIDE/WALL FLASHING #27 INSIDE CORNER #13 SLIDING DOOR HOOD #41 HANG ON GUTTER #31 JAMB FLASHINGS #30 SCULPTURED EAVE FLASHING #42 HANG ON GUTTER - 6 -

COMMERCIAL SPECIFY PITCH 21. SPECIFY PITCH 22. SPECIFY PITCH 23. 24. 1 1 9 9 8" 8" 5 3" 1 DIE FORMED RIDGE CAP EXTENDED RIDGE EXTENDED HIP GABLE START 6" 25. 3 26. 27. 28. 1 3 1 1 5" 3 2" 2" 4 1 1 SCULPTURED RAKE 1 FLASHING RAKE & CORNER INSIDE CORNER SIDEWALL FLASHING 29. SPECIFY PITCH 30. 31. 32. 2 1/8" 3 1 1/ 1 SKYLIGHT TRIM 33. 3 2 5/8" 2 5/8" 2" 1 1 1 3/8" 1 3/8" SCULPTURED EAVE FLASHING JAMB FLASHING HEAD FLASHING 34. SPECIFY PITCH 35. SPECIFY PITCH 36. 3 1/ 1 1 1 2 1/ COLOR BASE & DRIP FLASHING RAT GUARD EXTENDED VALLEY 2" EXTENDED VALLEY WITH HOOKS 37. 38. 39. 40. SPECIFY DIMENSIONS & DEGREE OF ANGLE 18 3 / NOT AVAILABLE SPECIFY DIMENSIONS & DEGREE OF ANGLE 2 2 COLOR COLOR 8 1/8" 8 1/ 8" PURLIN CAP 8" PURLIN CAP WITH HEMS OUTSIDE ANGLE ACTUAL DIMENSIONS MAY VARY CERTAIN RESTRICTIONS APPLY INSIDE ANGLE - 7 -

SPECIFY PITCH 41. SPECIFY PITCH 42. SPECIFY PITCH 43. SPECIFY PITCH 44. 3 3 HANG ON GUTTER #41 SPECIFY PROFILE 45. G PANEL or R PANEL 12" 5 3/8" GUTTERS & DOWNSPOUTS 5/8" 1 3 1 G 6" HANG ON GUTTER #42 EAVE GUTTER #43 EAVE GUTTER #44 END 1 1/8" 4 END 4 1/ 4 3" 6 1/ 3 3 2 1/ 6" SPECIFY LEFT or RIGHT SPECIFY GUTTER PART # 46. A B C 3 GUTTER HANGER 3" 5" 6" DOWNSPOUTS A 3" X B X 5" 1 C 3 / 2 " X 6" 45 or 90 47. 48. A 3" X 49. HANG ON GUTTER #41 END HANG ON GUTTER #42 EAVE GUTTER #44 DOWNSPOUT #47 INSIDE CORNER GUTTER #54 OUTSIDE CORNER GUTTER #53 OUTSIDE STRAP #51 GUTTER HANGER #45 DOWNSPOUT WITH INSIDE STRAP #52 KICKOUT #49 DOWNSPOUT OFFSET #50 END EAVE GUTTER #43 KICKOUT #48 GUTTER ENDS LEFT & RIGHT B X 5" 1 C 3 / 2 " X 6" 45 or 90 DOWNSPOUT WITH KICKOUT 50. A 3" X B X 5" 1 C 3 / 2 " X 6" 45 or 90 TO FIT KICKOUT A 3" X B X 5" 1 C 3 / 2 " X 6" TO FIT DOWNSPOUT OFFSET 51. 52. SPECIFY PART # 53. SPECIFY PART # 54. A 3" X B X 5" 1 C 3 / 2 " X 6" TO FIT TO FIT OUTSIDE DOWNSPOUT STRAP INSIDE DOWNSPOUT STRAP OUTSIDE GUTTER 90 ACTUAL DIMENSIONS MAY VARY CERTAIN RESTRICTIONS APPLY INSIDE GUTTER 90-8 -

FASTENERS, CLOSURES, SEALANTS & ACCESSORIES LAP SCREW WOOD FRAME SCREW CEE PURLIN BASE ANGLE STITCH SCREW METAL FRAME SCREW ZEE PURLIN EAVE STRUT 5-V PANEL OUTSIDE CLOSURE 5-V PANEL INSIDE CLOSURE GOLDINPANEL RIDGE CONDITIONS, OUTSIDE CLOSURES CORRUGATED REVERSIBLE CLOSURES R PANEL PROFILE VENTS GOLDINPANEL OUTSIDE CLOSURE GOLDINPANEL INSIDE CLOSURE EAVE CONDITIONS, INSIDE CLOSURES EXPANDING UNIVERSAL FOAM CLOSURE R PANEL OUTSIDE CLOSURE R PANEL INSIDE CLOSURE BLACK GRAY OR RED CONTINUOUS RIDGE VENT GOLDINPANEL RUBBER ROOF JACK RETROFIT ROOF JACK R PANEL SKYLIGHTS TUBE AND TAPE SEALANT FIBERGLASS VINYL & REINFORCED VINYL BACK INSULATION SINGLE BUBBLE DOUBLE BUBBLE FOIL & WHITE FACING REFLECTIVE INSULATION FOIL, VINYL, REINFORCED, AND DOUBLE SIDED INSULATION TAPE - 9 -

SERVING ALL YOUR BUILDING NEEDS ASK ABOUT THESE ADDITIONAL PRODUCTS STEEL JOIST & METAL DECK FRAMED WINDOWS 3618 3636 3625 4425 3070 & 3068 WALK DOORS WALL LOUVERS SLIDING DOORS TRACKS & RAILS MOTOR DRIVEN & CHAIN OPERATORS BRACKETS & HARDWARE LATCHES & HARDWARE GOLDIN METALS OFFERS A COMPLETE LINE OF COMMERCIAL ROLL UP DOORS, MINI SELF STORAGE DOORS AND ACCESSORIES. SPECIAL ORDERS TO FIT ANY NEED. - 10 -

STEEL SERVICE CENTER LOW PRICES DELIVERY STEEL ANGLES FLATBARS CHANNELS BEAMS ROUNDS SQUARES PLATES SHEETS FLOOR PLATES PIPE ROUND AND SQUARE TUBING REINF. BARS & MESH GRATING EXPANDED METAL CULVERTS FENCING METAL DECKING BAR JOIST METAL STUDS ALUMINUM BRASS COPPER STAINLESS STEEL (228) 896-6216 ext. 230 SINCE 1942 METAL ROOFING AND SIDING PANELS LOW PRICES LARGE INVENTORIES CUSTOM CUT LENGTHS VARIOUS GAUGES STANDING SEAM PANELS COMMERCIAL RESIDENTIAL INDUSTRIAL FASTENERS MAGNETIC SOCKETS RIVETS CLOSURES SEALANT CAULKING TAPE PROFILE VENT PIPE FLASHING INSULATION SKYLIGHTS RIDGE VENT PURLINS OPEN CHANNEL EAVE STRUTS BASE ANGLES HAT CHANNEL WALK DOOR ROLL-UP DOOR SLIDING DOOR/TRACKS/TROLLEY CUSTOM DESIGNED TRIMS GUTTERS DOWNSPOUTS GOLDINPANEL 36" COVERAGE 9" 9" 9" 9" 5/8" DRAIN FEATURE R PANEL 36" COVERAGE 12" 12" 12" 1-1/ Other patterns available. - 11 -

TERMS AND CONDITIONS OF SALE Goldin makes no warranty, express or implied, as to the merchantability or fitness for any ordinary or particular purpose of any goods sold. Goldin will not be liable to Buyer for any actual, special, direct, indirect, incidental, or consequential damages including loss of use which Buyer may suffer. The customer is responsible for filing freight claims for shortages and damage in transit, whether visible or concealed. Goldin s responsibility ceases when the carrier signs for the shipment in good order. Failure to indicate shortages or damages on the signed Bill of Lading shall immediately waive any claim of shortage or damage. It is Buyer s responsibility to retain the Bill of Lading. Loss of the Bill of Lading shall also waive any claim of shortage or damage to goods. Goldin is not responsible for bodily injuries or material damage due to improper handling during unloading, storage, or job-site placement. Goldin shall not be liable to Buyer for any direct or consequential damages, including loss of use to Buyer, arising out of any delays due to transportation difficulties, priorities of any kind, failure of equipment, accidents, weather, fire, strikes, act of God, war, insurrection, mob action, act of government, loss, damage or delay of material, floods, storms, inability to obtain materials, or other acts or circumstances, and no penalties or liquidated damages are provided for herein. Full payment of the C.O.D. invoice amount, including taxes and freight charges if any, must be made to the truck driver before any goods can be unloaded. Buyers are responsible for sending suitable vehicles, capable of hauling the size and weight of the Buyer s order. Since Goldin loads with overhead cranes and forklifts, a flatbed trailer without side boards is most suitable. Goldin cannot load open end, closed trailers, such as horse trailers. Goldin shall not be responsible for any damages to a vehicle or goods as a result of the type of vehicle used. Buyer shall be responsible for providing a method for securing the goods to the vehicle and for securing the goods. Goldin shall not be responsible for any damage or loss of goods, or damage to vehicles or persons caused from unsecured or improperly secured goods shifting or falling from Buyer s vehicle during transport, or caused from Buyer rearranging or loading goods. Buyer shall indemnify and hold Goldin harmless, including costs and attorney s fees, from any and all claims made against Goldin relating thereto. Loading or rearranging of goods by Buyer shall not be allowed on Goldin s premises. Any order which has not been shipped or picked up within 15 days of completion risks damage from prolonged storage and excessive handing within the loading area. Goldin shall not be responsible for any damage to, or loss of, any part of such an order. Buyer will reimburse Goldin for the cost of handling and storing materials if shipment is delayed by Buyer. The type, size, length and/or gage of materials required is always the Buyer s responsibility and it is Buyer s responsibility to confirm that the product meets their specifications, including but not limited to type, size, length and/or gage of materials. Salespeople will offer information on its products which Buyer needs to compose the list, but under no circumstances will Goldin be responsible for a goods take-off. Goldin does not offer or provide engineering or design advice or expertise. Goldin shall not be responsible for any damage or injury resulting from design problems of any kind. Goldin s goods should be installed by qualified professionals. If Buyer is not a qualified professional himself, Buyer should hire an erector who is trained and experienced with installing and erecting steel building materials. Goldin shall not be responsible for damages to property or injuries to persons due to negligent or improper installation by any person. - 12 - #5002