GRASSELLO DI CALCE BIANCO Natural mineral calcium dyoxide at long aging, which lays to a glossy finish

Similar documents
AK40 PRIMER ACRILICO HS Two-component acrylic monolayer primer

4970 PRIME COAT FZ Two components zinc phosphate epoxy product

TECHNICAL DATA SHEET

MITHOS LUX is a traditional self-polishing Venetian lime putty-base stucco for interiors

Technical Data Sheet

Technical Data Sheet

Property Test/Standard Description. Flash point ISO 3679 Method C

Apply a very thin single coat of NATURWAX using a cloth, pad, or trowel.

Technical Data Sheet Rhenopox EB 06.1 Art. no.: A 5198

DMS EP-D80 Broadcasted Epoxy Resin Floor

Property Test/Standard Description Solids by volume. ISO 3233 Flash point ISO 3679 Method C

PROTEX WB Eco-friendly, water-based, easy to apply impregnating sealer to protect natural stone against rising damp and stains.

Data Sheet Eco-Smart Membrane WS M1

Epoxy Based, Two Component, Grouting Filling and Ceramic Adhesive Resistant to Chemicals and Bacteria

Product Cod. HIGH RESISTANCE SELF-LEVELING COMPOUND BASED ON POLYURETHANE RESINS IN WATER DISPERSION AND HYDRAULIC BINDERS.

Approved. This product is tintable in a wide range of colours in Jotun's Multicolor Decorative (MCD) system. Property Test/Standard Description

BTM BT2K 600. Areas of Use

Exterior pipes, Fences, screens, grills and gates, Metallic Structures, Structural elements (column, trusses, etc.)

1 ST KOTE HI COVER PVA

JSCE-K Test methods for weathering resistance of. concrete surface coating materials

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Concrete Paint and Varnish

Stormshield Self-Cleaning Masonry

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Data sheet Armatop A - new / Page 1. Areas of application Bonding Bonding of mineral wool, polystyrene and cork external wall insulation boards.

HAMMERITE NO. 1 RUST BEATER PRIMER

SYSTEMDATENBLATT Sika Cable-System

TECHNICAL INFORMATION SWARCO UV-LINE Paint

Property Test/Standard Description STANDARD GRADE

Data Sheet 3631 Englisch

1(5) Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.

General: Primarily designed for maintenance and repair. Only aluminium containing versions to be used in immersed environments.

MATERIA Water- based epoxy resin, for the decoration of floors and walls with a limitless effect.

Pre-qualification testing in accordance with NORSOK M-501, Rev. 3/4, System 7, suitable for splash zone. Property Test/Standard Description

Property Test/Standard Description. 96± 2 % matt (0-35) Flash point ISO 3679 Method 1 34 C

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards.

Data Sheet 832 Englisch

Property Test/Standard Description STANDARD GRADE

SATIN NON-DRIP ACRYLIC

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-USA / VOC Hong Kong EPA Method 24

vinyl ester Property Test/Standard Description semi gloss (35-70) Flash point ISO 3679 Method 1 34 C calculated IED (2010/75/EU) (theoretical)

Imron HydroClearCoat. 2K Waterbased Clearcoat PUR. Technical Data Sheet. Description

PRODUCT CATALOGUE PRODUCT CATALOGUE.

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (28 C) VOC-USA / VOC Hong Kong EPA Method 24

CHARACTERISTICS / ADVANTAGES. Yellowish-transparent. PACKAGING 20 kg per pail

Approved. Marine: Exterior areas, specially designed for outside hull, may be used on superstructure, decks and other external areas.

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1

Red Insulating Varnish 4228 Technical Data Sheet 4228-Liquid

Marine: Exterior and interior areas, including outside hulls, superstructures, decks, cargo holds and water ballast tanks.

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description

Speical, substrate-tolerant primer

PRODUCT DESCRIPTION PROCESSING

For purchasing information visit: Sikkens Cetol Novatech

PRODUCT INFORMATION SABRESHIELD

Pre-qualification testing in accordance with NORSOK M-501, Rev. 3, System 7, suitable for splash zone. Property Test/Standard Description

MARMOCRYL SILICONE Fine

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

IONTRA DENEB , CATALOG

White, a range of ready-mixed colours, and colours from the Dulux Colour System

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

TECHNICAL DATA SHEET

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

DOWSIL ALLGUARD Silicone Elastomeric Coating

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (35 C) VOC-USA / VOC Hong Kong EPA Method 24

DULUX WEATHERGUARD FINE TEXTURED

Red Insulating Varnish 4228 Technical Data Sheet 4228-Liquid

GULF COAST PAINT MFG., INC

Property Test/Standard Description Solids by volume. ISO 3233 Gloss level (60 ) ISO 2813

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

BONDEX Premium Product Code Product Name Recommended for Available sizes

Diescolith SOL-Silikat

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Two component solvent-free epoxy system for creation of self-levelling floors. Gloss <4% <70% IR4

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

COOL BARRIER RESIST* High Solar Reflective Water Resistant Flexible Dust Resistant Waterbased

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C

Property Test/Standard Description

Micastone Coating System

Data sheet Armatop MP / Page 1

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

PRODUCT DATA SHEET Sika Unitherm Platinum

OWL FORCE 10 (A+B+C) Epoxy-cement waterproofing (water barrier).

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

Property Test/Standard Description

ROCKGRIP UNIVERSAL ACRYLIC PVA

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 32 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

PRODUCT DATA SHEET. Sika Pyroplast Wood T with Topcoat Sika Pyroplast Wood Top T PRODUCT DESCRIPTION

two component polyamide cured epoxy primer yellow/green - eggshell

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 35 C

0 PROCESS OF CRACKING 2

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (30 C) calculated VOC-US/Hong Kong

E.MIX MOISTURE SEALER

Installation Instructions. Important. Recommended Tools. Palladium Rigid Sheet/Rubrail or Palladium G2 Sheet/Rubrail. Storage

Transcription:

Destination Indoor and outdoor decoration of buildings evn of those with particular historicartistic importance. Even if it reaches a high thickness layer, it has a high breathability Characteristics Readytouse Antibacterial Adherence to mineral supports BREATHABLE Good light resistance VOC (Directive 2004/42/CE) ( g/l ) 200 <Decorative effects paintings.eu limit value for this product (Cat. A/l): 220g/l (2010). This product cointans max. 200 g/l Recommended surface and temperature conditions Avoid applications at room temperatures lower than +10 C or higher than +3 C and relative humidity higher than 80%. Check the surfaces suitability referred to the humidity degree with hygrometer. Support temperature: min +10 C, max +3 C. Avoid application on chalking surfaces if not peviously treated with fixatives model FIXODIL for outdoors or Acrilan 3470 for indoors. WARNING:ventilate the room to avoid humidity accumulation. WARNING:the maximal washability is obtainable after 710 days from application. Completely eliminate preexistent solvent paintings. Remove, wet sanding or brushing, the possible efflorescences. In presence of moulds, use antimolds detergents and fixing elements. Reccomendations Well mix the product before use The applications must not be executed on walls directly exposed to the sun or with room temperatures under + C. In case of doubt, with old chalking or just a little cohesive paintings, evaluate the first coat dillution. Apply the fixative primer on a little surface portion and after at least 12 hours make an adhesion test. It is recommended to apply the product in favorable weather conditions, as inadequate weather conditions could negatively affect the drying conditions by compromising the optimal achieving of the product aesthetic characteristics and performances. Page 1/

Application cycle Never painted interior walls In case of new civil plasters let it age for at least 28 days (T= 20 C and UR< at7%) ) before any operatin. Carefully brush. Remove bad anchored parts, dust and dirt. level imperfections with STUCOL. After 8 hours level the stuccoed parts and clean them carefully. Be sure that the wall is perfectly dry. Verify surface idoneity according to humidity degree with match test or hygrometer. If necessary, consolidation with water fixative as ACRILAN 3470. In case of chalking supports use solvent fixative as FIXODIL, otherwise use the following modalities. If the support does not need fixative, it is anyway recommended to moisten it, to avoid the wall to subtract excessively water from the binder. After 24 hours from fixative application apply a first layer of GRASSELLO DI CALCE. After at least 12 hours apply one more layer to create the adequate thickness. After at least 12 hours sand to remove possible imperfections, then remove dust and apply little quantities of material compacting and polishing it (with inox trowel) beofre it dries completely. Clean the tools withh water after use. Already painted interior walls with tempera paintings Carefully clean the surface from dust or dirt. With molds or fungi disinfect the surfaces with SESTRICID. Level imperfections with STUCOL. After 8 hours sand the stuccoed parts and clean them carefully. Insulate the whole surface with solvent fixative as FIXODIL. After 24 hours apply a first layer of GRASSELLO DI CALCE or marmorino. After at least 12 hours apply one more product layer to cerate the adequate thickness. After at least 12 hours sand to remove possible imperfections, then remove the dust and apply little quantities of material, compacting and polishing it (with inox trowel) before it dries completely. Clean the tolls withh water after use. Page 2/

Application cycle Already painted interior walls with washable hydropaintings Carefully clean the surface from dust or dirt. With molds or fungi disinfect teh surfaces with SESTRICID. Level imperfections with STUCOL. After 8 hours sand the stuccoed parts and clean them carefully. Be sure that the wall is perfectly drt. Verify surface idoneity according to humidity degree with match test or higrometer. In case of much chalking supports use solvent fixative as FIXODIL. After 24 hours apply a first layer of GRASSELLO DI CALCE or marmorino. After at least 12 hours apply one more layer to give the adequate thickness. After at least 12 hours wet sanding to remove possible imperfections, then remove the dust and apply little quantities of material, compacting it and polishing it (with inox trowel) before it completely dries. Clean the tools with water after use. Never painted exterior walls In case of new civil plasters let age for at least 28 days( T= 20 C and U.R. < at 7%) before any operation. Carefully brush. Remove badanchored parts, dust and dirt. Level imperfections with special plasters. Wait the drying times and sand the stuccoed parts and clean them carefully. Be sure that the wall is perfectly dry.. Verify surfaces idoneity according to humidity degree with match test or higrometer. If necessary, use water fixative for solidification as ACRILAN 3470. If the support does not need fixative, it is recommended to moisten it, to avoid that the wall subtracts excessively the watre in the binder. Apply a first coat of product diluted at 3 40%. After at least 4 6 hours apply a second layer of prodct diluted at 30 3%. Already painted exterior walls Completely remove the old organic paintings as synthetic ones, washable quartz, tempera and plastic coatings. Carefully clean the surface from dust or dirt. With molds or fungi disinfect the surfaces with SESTRICID. Level imperfections with STUCOL. After 8 h sand the stuccoed parts and clean them carefully. Be sure that the wall is perfectly dry. Verify surfaces idoneity according to humidity degree with match test or higrometer. If necessary, use water fixative for solidification as ACRILAN 3470. If the support does not need fixative, it is recommended to moisten it, to avoid that the wall subtracts excessively the watre in the binder. Apply a first coat of product diluted at 3 40%. After at least 4 6 hours apply a second layer of prodct diluted at 30 3%. Page 3/

Characteristics and technical informations Tin aspect RESIN Color Use Data observable at T=20 C and 60% relative humidity Tixotropic White White suitable for tintometric system MW2 Adherence to mineral supports Spatula Thinner Tools' cleaning Application process Water Water Brush Thinner (% Volume) TECHNICAL DATA Complete polymerisation days Recoating interval ( h ) Minimum film temperature ( C ) 7 10 12 Notice Mass density ( kg/l ) Solids content by vol. ( % ) Brooklfield viscosity (cp) Brilliance ( % ) Touch dry ( h ) Depth dry ( days ) recommended dry film thickness (dtf) ( µm ) Theoretical spreading rate ( mq²/lt ) Data refer to the product mixed at 20 C. 1,60 6 8 1 (kg/m²) Glossy Page 4/

STORAGE (dry and cool place) 12 months in tightly closed package, protected from frost and heat sources Storage temperature ( C) + +30 Unit size 23 kg Safety instructions Products must be treated with attention, avoid the skin contact. Users will have to follow the actual laws. Actions as wet sanding, sanding, removal with flame, etc. of old painting coats can geerate dust and dangerous smokes. Work in well areated areas and wear the adequate individual protection means. In Italy Decree 303 and 47 concern the rules valid for the application operations. For further information concerning the right product elimination, storage and manipulation please consult the relative taìechnical data sheet. Data in this technical sheet are only given for information and are the result of laboratory tets and practical experience, However, the factory is not responsible if the product isn't used under its direct control. SESTRIERE VERNICI Srl Technical Assistance is available to give all information necessary for a correct use of the product. Be careful: the product could show, towards some subject who are particularly sensitive to isothiazolones, a little irritation. It's thus recommended to use gloves and protective glasses and to wash very well the parts which could by chance touch the skin. Page /