HIGH TEMPERATURE FURNACES. High Temperature Chamber Series High Temperature Tube Series High Temperature Elevator Series

Similar documents
ATMOSPHERE CONTROLLED TUBE FURNACES. PTF Series High Temperature Tube Series Precision Series Split Series Rotary Series Modular Series

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

Laboratory.

Experts in Furnaces. Engineering. Fast and flexible. THERMCONCEPT powerd by innovation

Laboratory Chamber & Tube Furnaces. Testing Analysing Ashing Drying Preheating Debinding Firing Sintering Annealing Melting

Laboratory.

Buying a New Lab or Industrial Furnace?

Glass. Furnaces and Heat Treatment Plants for

PRODUCT DATA SHEET MTP Series Furnaces

Laboratory. Keison Products Tel: Fax:

Laboratory. Made in Germany

STARTER Series Furnaces

Furnaces AND SAFETY! THERMOLYNE QUALITY - LOW PRICE! FB (1.3) 66 FB (2.1)

Compact Vertical Split Tube Furnace - EVT / EVZ

Cress Furnaces. Cress Manufacturing Co. Bringing you years of. experience in the. heat treating industry. Quality low cost. with a fast turnaround.

Dental. Furnaces and Accessories. Zirconia Sintering Furnaces Furnaces for CAD/CAM Systems Burnout Furnaces Model Casting.

Outstanding range of ovens

Glass. Fusing Decorating Cooling Tempering Melting Debindering Sintering Laboratory. Made in Germany

Glass. Furnaces and Plants for

Series MIM 3000 For Metal Injection Molded Parts *Complete MIM * Fully Automatic * User Friendly Processing Flexibility Operation Computer Control

Contact Details: Phone Fax . Work Description: New Building Extensions Refurbishment Change of Use. Yes No Method:

Superthal High power heating modules for customized furnaces and heaters

Heat Treatment of Metals

Laboratory furnaces and dryers CATALOG. Art of heating

Dental. Furnaces and Accessories.

Conveyor Oven RFQ Form

Laboratory Chamber & Tube Furnaces. Testing Analysing Ashing Drying Preheating Debinding Firing Sintering Annealing Melting

Each furnace has an independent 8 segment programmable controller and each has over-temperature protection and RS232 communications.

Geothermal Power Plant

Dental. Furnaces and Accessories.

Thermal processing equipment for laboratories

BURNERS EXCESS AIR SINGLE TUNNEL COOL FLAME

From Research to Manufacturing

Kinetics Noise Control

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

L A B O R A T O R Y E Q U I P M E N T S F U R N A C E S

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Utility Cabinet System (UCS)

Ar ts & Craf ts. Furnaces and Accessories. Pottery Porcelain Painting Glass Painting Fusing Decorating Enamelling Raku.

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Robust flue gas probes for industrial emissions measurements.

Red Devil R. D. WEBB COMPANY INC. Air Cooled Vacuum Furnaces Inexpensive Simple Reliable. Sintering - Brazing - Annealing Vacuum or Inert gas

Reflux Samplers for Process Gas Chromatographs Their Use and The Importance of Product Design

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

prothermfurnaces.com Respectfully,

Steam Power Station (Thermal Station)

Ventum Series. The new Generation Wood Gasification Boilers. Europe s Fastest Selling Wood Gasification Boiler.

PRODUCT CATALOGUE Laboratory Furnaces

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

PRODUCTION VACUUM FURNACES

R A S C H K A. Compact -Fluidized Bed Incinerator

Furnaces. Laboratory and Industrial. Precise, Efficient, and Reliable Furnaces and Process Systems

Glass Plant Equipment Manufacturers

Thermal Process Technology

FOLDING CONTAINER HOUSE: AMH-4000 SERIES GENERAL AMH-4120 DIMENSIONS AND WEIGHT PICTURES:

Thermal processing equipment for laboratories Vilnius, Lietuva

High Temperature Vacuum Tube Furnace GSL Operational Manual

SECTION COOLING TOWER

SECTION PLUMBING PIPING SYSTEM

EXCEL and HIMELT crucibles

ECOCASITA PLUS63. Drawings. Outside elevation example. Ground floor plan example. Page 1 of 27

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

1. Start by removing the ash-pit door. Remove from frame by removing two rivet pins. Remove the frame by unscrewing the 4 bolts. (Fig 1.

INVITATION FOR QUOTATION. TEQIP II/2012/WB2G02/Shopping/41

Compact flue gas analyser: testo 300 M-I

THE WORLD LOOKS UP TO COMPOSITE ELEVATED TANK

FITOCLIMA WALK-IN STABILITY

M I N I C O L D R O O M TECHNICAL SPECIFICATIONS

Road Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels

WINDOWS & DOORS GSG STRUCTURAL ALL GLASS SYSTEM

INDUSTRIAL ACCESSORIES COMPANY

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

SITHE SUBMERSIBLE CHOPPER PUMPS BY BARNES. Excellence in Innovation.

SITHE SUBMERSIBLE CHOPPER PUMPS BY BARNES. Excellence in Innovation.

FITOCLIMA 600 & 1200 BIO

VERSATILE MULTIPURPOSE HEATERS RANGE

CeraTHERM stack. Clean room-compatible thermal systems with stacking technology. Thermal systems

Test of Abnormal Heat in Hydrogen Loaded Metal

Heat Treatment. Customized solutions for your heat treatment needs.

GET A MAXIMUM! Hybrid Tilting Rotary Furnaces for Efficient Aluminium Recycling. - engineering your visions -

T/C, Noble, Straight Ceramic

Custom Systems Built to Exacting Client Specification

ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES

Experimental and Analytical Results on H 2 SO 4 and SO 3 Decomposer for IS Process Pilot Plant

WINDOWS & DOORS SYSTEMS

WINDOWS & DOORS SYSTEMS

Pioneering ALD experience since The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS

Foundry. Melting Holding Transporting Core Drying Thermal Decoring Dewaxing Heat Treatment Annealing Tempering Preheating Quenching

Influence of Firing Temperature and Atmospheric Conditions on the Processing of Directly Bonded Copper (DBC)

FIELD OF APPLICATION

Department of Basic Sciences and Social Sciences NORTH-EASTERN HILL UNIVERSITY MAWLAI UMSHING, SHILLONG

400 C WHT 4/30 WHT 4/60 WHT 4/ C WHT 5/30 WHT 5/60 WHT 5/ C WHT 6/30 WHT 6/60 WHT

PRODUCT DESCRIPTION PARAMETERS

Thermocouple Reference Table

No. CIHT:JAL:P:499(Vol.VI): Dated: / / 2013

CURING OVENS for Composite Manufacturing & Repair with Advanced Process Computer Control A Turn-Key Service for Oven Engineering For OEMs and MROs.

Welland Series. Outstanding features

CONTENTS. Prins Greenhouses WEST No. 4 Road, Abbotsford, BC Canada V3G 2G2 Phone: Fax:

BAG FILTERS (BAGHOUSES)

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

Transcription:

HIGH TEMPERATURE FURNACES High Chamber Series High Tube Series High Elevator Series

Chamber Furnaces MoS Series MoS series have been used as trusted professional chamber furnaces for many years in laboratories. Available with brick and fiber insulation elements, with a wide variety of options, these models can be optimally used for high temperature procedures. MOS 170/4 Standard MoS series furnaces cover a range from 1600 C to 1800 C, all of which have front loading for easy operation and double skin construction to maintain a cooler outer case. Important advantage of the model is that element change is very easy and economic. Furnaces starting from 1800 C use high quality Molybdenum Disilicide heating elements, providing a very long service life. Galvanized coating covered epoxy painted structure, providing longer life time and aesthetics. Typical applications for the product is almost all high temperature applications where high level of precision is required; high temperature sintering processes such as Ceramic, Dental and Material Research. System Features Vertical counter balanced door Standard door safety switch Customized controller option High-quality fiber material High level temperature uniformity Bottom protection, alumina plates on the floor Standard brick design on the outer skirts of the door and the furnace opening providing protection from possible unwanted damages during loading and unloading. Table top and Self-Standing design High quality heating elements ensuring a long service life System operation with solid-state-relays Short heating times Electrical protection Working s of up to 1800 C Dual skin housing for low external temperatures and high inner temperature stability Easy replacement of heating elements Intuitive controller user interface MoS Series, Table Top Information Maximum Volume (liters) Approximate MoS-B 150/1 1550 1500 12x12x9 1.3 71x51x47 1.5 1 220 MoS-B 150/2 1550 1500 14x12x15 2.5 77x51x51 3.3 1 220 MoS-B 160/1 1600 1550 12x12x9 1.3 71x51x47 1.5 1 220 MoS-B 160/2 1600 1550 14x12x15 2.5 77x51x51 3.3 1 220 MoS-B 160/4 1600 1550 14x14x20 3.9 66x82x52 4.4 1 400 MoS-B 160/8 1600 1550 18x18x25 8.1 70x92x52 7.2 3 400 MoS-B 170/2 1700 1650 14x12x15 2.5 77x51x51 3.3 1 220 MoS-B 170/4 1700 1650 14x14x20 3.9 66x82x52 4.4 1 400 MoS-B 170/8 1700 1650 18x18x25 8.1 70x92x52 7.2 3 400 MoS-B 180/2 1800 1750 14x12x15 2.5 77x51x51 3.3 1 220 MoS-B 180/4 1800 1750 14x14x20 3.9 66x82x52 4.4 1 400 MoS-B 180/8 1800 1750 18x18x25 8.1 70x92x52 7.2 3 400 Supply Voltage (V)

MoS Series, Self-standing System Information Maximum Volume (liters) Approximate MoS-F 160/8 1600 1550 18x18x25 8.1 145x58x61 7.2 3 400 MoS-F 160/12 1600 1550 24x20x25 12.0 145x62x61 9.0 3 400 MoS-F 160/16 1600 1550 24x22x30 15.8 145x62x61 11.3 3 400 MoS-F 170/8 1700 1650 18x18x25 8.1 70x92x52 7.2 3 400 MoS-F 170/12 1700 1650 24x20x25 12.0 145x62x61 9.0 3 400 MoS-F 170/16 1700 1650 24x22x30 15.8 145x62x61 11.3 3 400 MoS-F 180/8 1800 1750 18x18x25 8.1 70x92x52 7.2 3 400 MoS-F 180/12 1800 1750 24x20x25 12.0 145x62x61 9.0 3 400 Supply Voltage (V) MoS-F 180/16 1800 1750 24x22x30 15.8 145x62x61 11.3 3 400 *For system accessories please check the accessory page for furnaces. Optional Features Over-temperature limiter for thermal protection Adjustable air intake opening in the furnace door Exhaust air opening in the of the furnace roof Option of sideways opening door Observation hole enabling the operator observe the load during the operation Data logger with the software RS422/485 communication Cooling Fan for faster cooling processes Jet Fan for faster exhaust of gases Movable bottom enabling the operator to remove the sample while the furnace is still hot Quartz element protection for heating elements Protective gas system and connection

Tube Furnaces High Series High series tube furnaces are tube furnaces that could be used when laboratory experimentation is performed horizontally or vertically. Standard High series furnaces cover a range from 1600 C to 1800 C, using vertically mounted Molybdenum Disiciliside heating elements for processes. Vertical mounted elements provide ease of replacement 18/50/400 The stable temperature environment, and the option to be able to modify the furnace for a vacuum make these furnaces suitable for many possible processes. System Features Standard working tube of C610 and C799. Separate or integrated control system Customized controller option High-quality fiber material High level temperature uniformity Standard long working tube protruding from sides suitable for operation with flanges Electrical protection Galvanized coating covered epoxy paint structure High quality heating elements ensuring a long service life Intuitive controller user interface System operation with silicone controlled rectifiers Maxiumum Tube size (Dø x length) Heated Zone (cm) 17/38/200 17/50/200 17/75/200 17/38/300 17/50/300 17/75/300 17/38/400 17/50/400 17/75/400 1700 C 1650 40x600 200 83x46x53 3.0 1 1700 C 1650 50x600 200 83x46x53 3.0 1 1700 C 1650 75x600 200 83x46x53 3.0 1 1700 C 1650 40x700 300 83x56x53 4.0 3 1700 C 1650 50x700 300 83x56x53 4.0 3 1700 C 1650 75x700 300 83x56x53 4.0 3 1700 C 1650 40x800 400 83x66x53 4.8 3 1700 C 1650 50x800 400 83x66x53 4.8 3 1700 C 1650 75x800 400 83x66x53 4.8 3

18/38/200 18/50/200 18/75/200 18/38/300 18/50/300 18/75/300 18/38/400 18/50/400 18/75/400 Maxiumum Tube size (Dø x length) Heated Zone (cm) 1800 C 1750 40x600 200 83x46x53 3.0 1 1800 C 1750 50x600 200 83x46x53 3.0 1 1800 C 1750 75x600 200 83x46x53 3.0 1 1800 C 1750 40x700 300 83x56x53 4.0 3 1800 C 1750 50x700 300 83x56x53 4.0 3 1800 C 1750 75x700 300 83x56x53 4.0 3 1800 C 1750 40x800 400 83x66x53 4.8 3 1800 C 1750 50x800 400 83x66x53 4.8 3 1800 C 1750 75x800 400 83x66x53 4.8 3 *For system accessories please check the accessory page for furnaces. Optional Features Over-temperature limiter for thermal protection Display of inner tube temperature with an additional thermocouple Check valve at gas outlet Gas supply and blend systems for operation Alternative working tubes Gas and water cooled vacuum flanges Universal design for vertical and angular usage Data logger with the software RS422/485 communication

Elevator Furnaces ELV Series ELV series are designed for bottom loading operations and for quick charging and discharging procedures in laboratories. Available with brick and fiber insulation elements, with a wide variety of options, ELV series is used for glaze fritting, glass melting and applications requiring quick removal of products from the furnace. ELV 180/8 Standard ELV series furnaces cover a range from 1100 C to 1800 C, all of which have dual skin housing for low external temperatures and high inner temperature stability uniformity. Multi-layers of products could be fitted into the furnace, enabling the experimentation of several samples at a time. Gas feed-in with this series is a standard and various applications of gas controlled atmospheres is made possible. This series equip a galvanized coating covered epoxy painted structure, providing a longer life time and aesthetics. System Features Customized controller option High-quality fiber material Exceptional temperature uniformity Table top or self-standing design Hand fitted brick-on-brick seal High level temperature uniformity Short heating times High quality heating elements ensuring a long service life Electrical protection Precise, electric spindle drive with push button operation Working s of up to 1800 C System operation with solid-state-relays Intuitive controller user interface Maximum Volume (liters) (HxWxD) cm *For system accessories please check the accessory page for furnaces. (HxWxD) cm ELV 110/8 1100 C 1050 7.5 20x18x21 122x63x81 2.0 1 ELV 140/8 1400 C 1350 7.4 18x18x23 122x63x81 4.9 3 ELV 160/8 1600 C 1550 8.0 20x20x20 190x62x77 5.2 3 ELV 170/8 1700 C 1650 8.0 20x20x20 190x62x77 7.2 3 ELV 180/8 1800 C 1750 8.0 20x20x20 190x62x77 7.8 3 Optional Features Over-temperature limiter for thermal protection Exhaust air opening in the of the furnace roof Adjustable air inlet through the floor Data logger with the software RS422/485 communication Protective Gas System and Connection *For your inquiries and questions please contact us Web: www.prothermfurnaces.com Email: info@prothermfurnaces.com Phone: +90 312 257 1331