Chilled Water System Optimization

Similar documents
Intelligent. Powerful. Proven. usa.siemens.com/demandflow

CHILLED WATER SYSTEM OPTIMIZER

Persistence Tracking in a Retro-commissioning Program

In typical commercial buildings, water-cooled chilled water plants use a signifi cant amount of energy.

Chiller plant optimization

OMA Energy Efficiency & CHP/WER Working Groups. Chillers

IDEA Synopsis Submission

Optimizing Central Chilled Water Systems

Chilled Water Loop Optimization. Kazimir Gasljevic Richard Dewey Sandro Sanchez

Retro-Commissioning for Existing Facilities

Chilled Water Plant Statement of Capabilities

Optimizing Chilled Water Systems for Energy Efficiency and Occupant Comfort

PARK PLACE CASE STUDY VANCOUVER. Heat reclaim system expected to reduce steam consumption 80%, GHG emissions 68%

ADDENDUM NO. 01. Include this signed and dated addendum to your proposal.

Niagara Case Studies. Chirayu Shah General Manger Conserve It

Optimized System for Your Bottom Line. Trane Training Class 1 Dec, 2017

Using Water-Cooled Chillers to Exceed ASHRAE Minimum Efficiency Standard by > 50%

Level 1 Modules tdp-101 hvac industry overview tdp-103 concepts of air conditioning tdp-102 abcs of comfort

Project Information. Measure Description

To efficiency and beyond

ARMSTRONG DESIGN ENVELOPE FAQ

A Case Study of Control Problems and Resolutions in a High rise

Chilled Water Plant Design American Standard Inc.

Retro-commissioning and on-going commissioning 23 November 2016

LUNA SECONDARY PREPARATORY SCHOOL DALLAS, TEXAS ADDENDUM NO. 1

05/14/2012 THE CRIME OF IMPROPER ENERGY MANAGEMENT AGENDA

Introduction to Building Analytics

Large Campus Chilled Water System RetroCx

Retrocommissioning Investigation Study of the Sheraton Chicago Hotel

Virtual Energy Audits: The Promise and the Reality

Water cooled chiller plant (all-variable)

Acutherm was spec d here. Building Automation Guide for Therma-Fuser Systems

B. System Design and Performance Requirements

Trane Water-Source Variable Refrigerant Flow

Knowledge is Power Belimo Energy Valve CHW DELTA T MITIGATION STUDY AHR Expo Innovation Award Winner in the Category of Building Automation

Small Oil-Less Centrifugal Compressors: Bringing Energy Efficiency and Reduced Costs to Chiller Plants

Energy Efficiency Baselines for LABORATORIES. PG&E s Customized New Construction and Customized Retrofit Incentive Programs.

Chilled Water Energy Savings Study

Application of Near-Optimal Tower Control and Free Cooling on the Condenser Water Side for Optimization of Central Cooling Systems

Management Committee December 3, Johnson County Community College Retrocommissioning Report

September 22, Roy Hubbard HVAC Systems Technology

The Part-Load Efficiency Benefit of Oil-Free, High- Speed, Direct-Drive Centrifugal Compressors

INCENTIVE ESTIMATOR HVAC USER GUIDE CONTENTS FLORIDA CUSTOM INCENTIVE PROGRAM

Intelligent System Design

Water cooled central plant (vp/vs) Design Envelope application guide

NEBBinar: Managing Building Performance through Commissioning. March 28, 2013

Rowan University Energy Management Optimization of our Central Chilled Water System

WHITE PAPER. Chiller Plant Optimization - A Practitioner s Perspective. Abstract

CONDENSING TEMPERATURE CONTROL THROUGH ENERGY MANAGEMENT SYSTEM SIMULATON FOR A LARGE OFFICE BUILDING

How the design of a cooling tower impacts energy usage and operating costs

Building Controls Strategies Conference. Retro-Commissioning with BAS Overview. 10 March Steve Brown, CAP ESD Controls Team Leader

Chapter 4. Analysis of Building Energy Performance

FlowSet. Balancing Procedure

Palm District Cooling 19XR Chiller Energy Optimization Kwh saving test

Chiller Optimiser Technical Specification

THE GREAT CHILLED WATER DEBATE. Michael Dagher

Innovations in Chiller Technology

Central Chilled Water Plant Sustainable Design. By : George Berbari, CEO DC PRO Engineering

District Cooling Sustainable Design. Presented by George Berbari CEO of DC PRO Engineering

Mission Critical Commissioning for Healthcare Facilities

Pay Now or Pay Forever Commissioning the Design of Control System Software

Building Energy Saving through Life-Cycle Optimization, Commissioning and Diagnosis Experiences in International Commerce Center (ICC) of Hong Kong

Retro-Commissioning in Hospitals

BCM00 Introduction to Building Controls and HVAC (available on request) One day course BCIA Members VAT Non-members VAT

A STUDY OF ABSORPTION CHILLER/HEATER APPLICATION IN MARINE ENGINEERING

Analysis and System Design of a Large Chiller Plant for Korea, with or without Thermal Storage

Higher Value Commissioning

An Alternative Approach to Chilled Water Optimization: Operator Advisory and On-going Training A 10,000 ton Central Chilled Water Plant Case Study

Central Chiller Plants

OAKDALE CHILLED WATER PLANT CAPACITY UPGRADES UI PROJECT INSTALL CHILLERS SECTION COMMISSIONING

D DAVID PUBLISHING. Optimizing Thermal Energy Storage Systems in the Hospitality Industry. 1. Introduction

OUR EXPERIENCE WITH RCX SOFTWARE: TRIUMPHS AND CHALLENGES

Retrocommissioning Investigation Report

The Building Systems Detective

VERIFICATION OF OPTIMUM OPERATION METHOD BY SIMULATION FOR THE HVAC SYSTEM WITH A THERMAL STORAGE TANK IN AN ACTUAL BUILDING

Large University Central Chiller Plant Design Considerations

TDPs provide you with new technical training materials designed to help your contractors, engineers, and designers to effectively design, specify,

Improving the efficiency, occupant comfort, and financial well-being of campus buildings

ME HVAC Systems, Topic 14, Cooling Equipment

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

DABO TM : A BEMS ASSISTED ON-GOING COMMISSIONING TOOL

Technical Development Program

Using Annual Building Energy Analysis for the Sizing of Cooling Tower for Optimal Chiller-Cooling Tower Energy Performance

ENERGY AS SERVICES COMPANY ESCO. Jamal E. Alostaz. Projects Engineer Al-Salem Johnson Controls

Energy Efficiency in Building Active Design Part II

ROOF TOP SPACE. SELF-CONTAINED REVERSIBLE AIR-AIR UNITS OF 23 TO 281 kw EVERY EFFICIENT SOLUTION FOR UNIVERSAL COMFORT NA C

Application of a cooling tower model for optimizing energy use

Final Report for National Grid USA Service Company. Evaluation of 2003 Custom HVAC Installations Part II. September 27, 2005.

Gregory W. Stevens and Ronald K. Ishii, Alternative Energy Systems Consulting, Inc.

Water cooled central plant (all-variable) Design Envelope application guide

Air-Water Systems. Chilled Ceilings and Beams TROX USA. Principle of Operation. Radiant Effect on Occupants. Early 1980 s. Chilled Ceiling Panels

Army Exceeds Energy Goal Ahead of Mandate (Actual Energy Reduction of 38% vs 30% and Achieved in 2010 vs 2015)

Absorption Chillers in Commerce

Innotech is a registered Trademark of Mass Electronics Pty Ltd Copyright 2013 Mass Electronics Pty Ltd

This article does not examine economic payback; a detailed energy. analysis is the best method of comparing system options and their respective

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

Varying Views. Variable-primary flow chilled-water systems are of. on Variable-Primary Flow WHAT IS VARIABLE-PRIMARY FLOW? >>>

NATIONAL CERTIFICATION EXAMINATION 2004 FOR ENERGY MANAGERS

Use of Building Automation Systems for (Retro)Commissioning

NEXT GENERATION ENERGY EFFICIENT TECHNOLOGIES: A CASE STUDY DEMONSTRATING TOP OPERATIONAL PERFORMANCE. The Aventine Chiller Plant Optimization

Transcription:

Advanced HVAC Diagnostics and Control Strategies Chilled Water System Optimization Brian Leduc Carrier Corporation August 16, 2017 Contents of this presentation 2017 Carrier Corporation Tampa Convention Center Tampa, Florida

Topics to be covered How is this approach to chilled water system optimization unique? How does it work? Compatible plant types Metering considerations System performance and test results System benefits Documentation 2

How is this approach unique? It takes a holistic approach to chilled water system optimization and considers the energy use of the entire chilled water system (supply and consumption) The algorithm automatically adapts to changes in environmental and system conditions that occur over time It is scalable and can optimize the chilled water system alone, the condenser water system alone, or both 3

How is the technology deployed? The optimization technology is deployed via a patented, self-adapting control algorithm, packaged in an application specific, native BACnet control module It is designed as an overlay on top of existing equipment controls that are already in place 4

What is meant by an overlay?? The logic in the optimization system works in conjunction with the incumbent control system It reads electrical consumption and other system data, then computes optimized chilled water and condenser water setpoints to lower the overall system /Ton The CWSO does not have hardware points; all optimization I/O functions are via network communications Example: Optimization system applied to a ChillerVu Plant Control System

How does it work? The CWSO improves overall system efficiency (/ton) by intelligently resetting the CHWS & CWS temperatures and reducing chiller lift In order to provide the lowest total energy consumption, the reduced chiller plant energy MUST be balanced with any increase in power that occurs on the load side pumping systems and fans Any energy savings must also be accomplished WITHOUT adversely affecting building comfort or causing equipment problems 6

How does it work? Chilled Water Reset It seeks out the lowest /ton by incrementally raising and lowering the chilled water supply temperature while measuring equipment energy consumption It is an adaptive algorithm that constantly searches for the lowest system /ton 7

How does it work? Condenser Water Reset It operates like chilled water reset, except it provides ideal condenser water temperature without excessive tower fan power consumption. Setpoint reset is based on OA Wet-Bulb temperature, tower approach and chiller load User configurable condenser setpoint limits prevent refrigerant stacking due to excessively low condenser temperatures at higher loads, or chiller surging at high condenser temperatures and low loads 8

How does it work? Simplified I/O Block Diagram 9

How does it work? On initial start up, the algorithm totalizes all available power inputs and also calculates the cooling load tons ahu fan It then calculates the current total system usage per unit of cooling in /ton /ton /ton Combined /ton Optimization block diagram 10

How does it work? Small setpoint adjustments (upward for CHW, downward for CW) are then sent in sequence to the plant control system tons ahu fan After a system specific delay, the /Ton is then recalculated If /Ton decreases, additional incremental setpoint increases/decreases will be sent If /Ton increases, the direction of the setpoint resets will be reversed Reset CWST Temp /ton /ton Combined /ton Optimization block diagram Reset CHWS Temp The process repeats continuously, raising and lowering setpoints while verifying the effect on overall system energy consumption, continuously seeking out the lowest possible /Ton 11

Ideal plant types for system applications Applicable to a wide range of systems, but ideally suited for comfort cooling applications in commercial facilities and campuses Supports a maximum of eight chillers Water or air cooled plants Types of chiller systems: Parallel plants Electric chillers including (centrifugal, scroll, reciprocating, screw). Absorption chillers not currently supported Variable flow chilled water systems Variable flow condenser water system Variable volume air handling units 12

System Metering The optimization logic requires metering on major system equipment The more system devices that are metered, the more effective the optimization calculations can be Sub-metering of system mechanical equipment can typically come from three sources: Communicating Equipment with Variable Frequency Drives Communicating Chiller Controls Field Installed Sub-Meters

Potential Efficiency Improvements: Potential energy savings are expected to range from 3-15% based on field tests and simulations Actual energy savings will depend on many variables; plant size, existing equipment selection, duration of use, how well it is controlled, climate zone, tolerance to setpoint adjustments, and other considerations The more system equipment that is metered, the more effective the optimization algorithm can be 14

Summary of Benefits Works with the mechanical system you have today; system modeling and pre-installation mechanical and control upgrades are not mandated Adapts to changing conditions in real time Scalable additional plant equipment can be easily assimilated into the optimization scheme One time purchase vs. subscription based Minimal post sales maintenance Localized optimization - Doesn t depend on cloud connections Can be enabled & disabled without interruption to the plant Minimal risk of system disruption vs. systems that assert direct control of mechanical equipment 15

2017 GSA Proving Ground Participation The technology being presented today was selected to participate in the 2017 GSA Proving Ground program, where it will be tested in one or more US facilities and evaluated by GSA and a team of engineers from the National Labs. The program is currently undergoing site selection. 16

Available Documentation Available customer documentation consists of : PD Sheet White Paper Guide Spec 17

QUESTIONS? 18