ELECTROLESS NICKEL DATA SHEET March 2013

Similar documents
4831 S. Whipple Avenue Chicago IL Phone: Fax:

NIPOSIT PM-980 W Semi-Bright Electroless Nickel Process For Industrial Finishing Applications

4831 S. Whipple Avenue Chicago IL Phone: Fax:

PavCoTing. Chromium appearance and corrosion resistance Ease of plating bath control Wide current density range

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

Alkzinc 818. Mirror bright finish Good zinc deposit distribution Very good adhesion and ductility Excellent chromate receptivity

HyProTec. Hexavalent free RoHS, ELV and WEEE compliant. HyPro System

E-Brite 30/30. Non-Cyanide Alkaline Copper Plating

DURNI-COAT DNC

Lumina. Bright, leveled deposits in less time Excellent ductility Good chromium reception Very low additive consumption rate. Nickel Plating System

PALLAMERSE SMT 2000 For PWB Metallization Applications

E-Chrome Ultra Yellow 600

Non-Cyanide, Non-Pyrophosphate Alkaline Copper Plating

HAVALLOY Z-C ACID CHLORIDE ZINC / COBALT PROCESS

Zinc Alloy Plating Ziniloy

COPPER GLEAM RG 11 Acid Copper Plating Process

Technical Process Bulletin

Laser EX 50 Product Code: Revised Date: 03/17/2009. Laser EX 50

E-Brite Ultra Cu-Mg. Non-Cyanide, Non-Pyrophosphate Alkaline Copper Plating

TECHNICAL BULLETIN IMMERSION SILVER - IS150

CIRCUPOSIT 71 Full Build Electroless Copper Nitrate Bath (Generic Concentrates) For Electronic Finishing Applications

AUTONIC MX, 440. AUTONIC MX Matrix 440 PROCESS: FEATURES: Stapleton Technologies Inc, Rev /99 Page 1 of 8

High Throw Bright Acid Copper for Rack and Barrel Plating

TriPass ELV 1500LT Iridescent Trivalent Chromium Passivate

NiClipse. Zinc Alloy Plating NiClipse

Technical Data Sheet. Physical Specifications

Lead-free electroless plating nickel bath for high wear and corrosion resistant applications

Ultrex CAA Product Code: Revised Date: 10/09/2006. Ultrex CAA Heavy Duty Alkaline Product Derusting - Descaling - Activation

Technical Process Bulletin

Stripol NI Ultra Product Code: Revised Date: 12/11/2012. Stripol NI Ultra

Technical Data Sheet

PALLAMET 500 Palladium-Nickel

NOTE: BONDERITE C-AK 4338C AERO should not be used on reactive alloys such as aluminum.

SurTec 650 chromital TCP

Ultrex EDM Product Code: Revised Date: 07/26/2006. Ultrex EDM Heavy Duty Alkaline Product Derusting - Descaling - Activation

Technical Process Bulletin

TECHNICAL DATA SHEET CUPROBRITE Revolutionary & New generation Bright Acid Copper Plating Process

Use vigorous air agitation while adding the components in the order shown: 2.7% by volume CIRCUPOSIT LC-9100C Electroless Copper

Technical Process Bulletin

AURALL 305M Electrolytic Gold For Electronic Finishing Applications

Deruster 11 J Product Code: Revised Date: 01/26/2009. Deruster 11 J

Ziniloy Zinc Alloy Plating

SILVERON TM GT-101 Bright Silver Cyanide-Free Bright Electrolytic Silver For Electronic, Decorative and Industrial Finishing Applications

ENVIRO/Etch Replenisher

Technical Data Sheet. Physical Specifications. ph 6-7. Storage Requirements

NiClipse C. Ammonium chloride free

ENFINITY HB. ENFINITY HB Electroless Nickel. Providing Quality Electroless Nickel Plating Processes since 1960 FEATURES:

ENFINITY HX. ENFINITY HX Electroless Nickel FEATURES: Providing Quality Electroless Nickel Plating Processes since 1960

SOLDERON BLS For Electronic Finishing Applications

Technical Process Bulletin

Technical Process Bulletin

SurTec 712 Alkaline Cyanide-Free Zinc/Iron Process

SurTec 704 Cyanide-Free Alkaline Bright Zinc Process of the New Generation

COMPLETE BARREL. ZINC PLATING SYSTEMS ZCl K3 MAINTENANCE

PREPOSIT Etch 748. For PWB Metallization Applications. For use in the CIRCUPOSIT 3000 Process. Bath Make-up Metric (for 100 liters)

SurTec 704 Cyanide-Free Alkaline Bright Zinc Process of the New Generation

TINGLO CULMO Bright Acid Tin Electroplating (with Starter/Brightener 2.5X) For Electronic Finishing Applications

Smart Zinc. Zinc Plating System

DE-88K. Ammonia free Temperature tolerance up to 110 F (43 C), reducing cooling costs. Zinc Plating System

NICKEL GLEAM BR 220 BRIGHT NICKEL PROCESS

Insta-Blak SS-370. Room Temperature Blackening Solution for Stainless Steel

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

Manufactured for North America exclusively by Automated Chemical Solutions, Inc E. Roeser Road Phoenix, Arizona 85040

Technical Process Bulletin

Non-Cyanide Alkaline Silver Plating

is a two component, water soluble, low ammonia zinc plating system suitable for either rack or barrel plating operations. ZCl NH 4

Laser ACB 50 Product Code: Revised Date: 03/17/2009. Laser ACB 50

NB SEMIPLATE AU 100 TH Bright Au electroplating process, sulfite-based, arsenic-free

CIRCUPOSIT Electroless Copper (USING CUPOSIT Z AND Y-1) For PWB Metallization Applications

ZINC PLATING SYSTEMS ZCL NH4

NB SEMIPLATE AU 100 Bright Au electroplating process, sulfite based, arsenic grain refiner

Technical Process Bulletin

P.T. SINAR CEMARAMAS ABADI

ELECTROPOSIT 1100 B-2 Acid Copper Additive

Alkaline Non-Cyanide Zinc Plating Process

Brass Plating Process

RONOVEL C AUROSPEED CVD

ELECTRONIC GRADE SULFAMATE NICKEL Document ID: EFM1409

CIRCUPOSIT Neutralizer 3313 For PWB Metallization Applications

BONDERITE M-NT 7400 CR FREE CONVERSION COATING (Known as BONDERITE 7400)

ZCl K3. Ammonia free Temperature tolerance up to 110 F (43 C), reducing cooling costs. Zinc Plating System

PALLADURE 200 Pure Palladium Process

NITEC CRYSTAL 1. Elektrolyt to achieve uniform and non reflective Nickel deposits

Tinmac Stannolyte Bright Acid Tin Solution

Lead free electroless plating nickel bath for high wear resistant applications

by Nicole Micyus, * MacDermid, Inc. New Hudson, Michigan, USA

SOLDERON SC Process. For Electronic Finishing Applications. Deposits meet or exceed Military Specification Method 202F, Method 208F.

NB SEMIPLATE AG 100 Ag electroplating process

ZINC PLATING SYSTEMS NH4 Zn/Co

SurTec 717 R Alkaline Zinc/Nickel Process

SurTec 881 Trivalent Decorative Chromium Process

SOLDERON MHS-W MATTE TIN AND TIN-LEAD PROCESS

SurTec 609 EC Pre-Treatment prior to E-Coat

Enerox Nickel Additive E 44 Product Code: Revised Date: 09/26/2007

Technical Process Bulletin

Enerox Nickel Additive E 66 Product Code: Revised Date: 02/28/2012. Enerox Nickel Additive E 66 High End Rack Plating

Lead-free electroless plating nickel bath for high wear and corrosion resistant applications

SUPER BEE 400TG-ML CLEANER by Cee-Bee

SurTec 650 chromital TCP

Black-Magic RT S 30 Product Code: Revised Date: 01/11/2013. Black-Magic RT S 30

Transcription:

105 North Gold Drive, Robbinsville, New Jersey 08691, Phone: 609-259-0099, Fax: 609-259-0077 www.surfacetechnology.com info@surfacetechnology.com ELECTROLESS NICKEL DATA SHEET March 2013 The following is a brief guide on the preferred operation of electroless nickel plating systems. For additional information, please consult the Parameters Page for the specific system in use and your Surface Technology, Inc. Technical Service Representative. EQUIPMENT The plating tank should be constructed of polypropylene, stainless steel (Type 316) or mild steel with a suitable tank liner depending on bath in use and other considerations. Stainless steel tanks may be anodically protected if desired. Filtration through a 10-micron or finer rated polypropylene filter bag system is suggested. Polypropylene wound cartridge filters are also permissible, but are not as easy to use as filter bags. The filtering pump system should turn the bath over at a rate of at least 10 times per hour. Filter bags should be well rinsed in hot water before use. For the specific filtration recommended for each bath, consult the appropriate Parameters Page. Agitation is useful in maintaining bath homogeneity and consistent finish. Air spargers with air from a high volume, low-pressure air blower is recommended. Compressed air is not recommended due to potential oil contamination. Other types of agitation, may also be used. For the specific agitation recommended for each bath, consult the appropriate Parameters Page. Heating of the bath may be accomplished by various methods including heat exchangers and immersion heaters. The bath temperature should be monitored and maintained closely. Cooling of the bath with an appropriate cooling apparatus should be done rapidly at the end of a shift or any time the bath will not be used for an extended period of time. Rack, barrel, and fixturing devices should only be constructed of compatible materials such as polypropylene, CPVC, stainless steel, PTFE, Viton, silicone rubber, and others that can withstand the chemicals and temperature of the plating bath and pretreatment process. Masking should only be accomplished with compatible materials such as certain vinyl tapes, stop-off paints, plugs and gaskets made of Viton, silicone rubber, and others that can withstand the chemicals and temperature of the plating bath and pretreatment process. OPERATION Review the data sheet, MSDS, and product labels for all components for safety and handling information. Only operate according to this Data Sheet and the respective Parameters Page. Insure you are using the most current Data Sheet and Parameters Page available from STI. Consult your Surface Technology, Inc. Technical Support Representative for any assistance on the pretreatment of the base materials to be plated. The tank should be clean and passivated. The most common method is with a solution of 40-50% nitric acid for 2-3 hours at room temperature, followed by rigorous rinsing and neutralizing of the tank and verification that no nitrate contamination remains.

Maintain the bath between 80% and 100% concentration of nickel, hypophosphite, stabilizers, or other chemicals. Tighter control will further help performance. Titrate the bath before and after every batch of parts that is plated. Replenish during plating cycles if the workload will lower the nickel concentration to 90% or less. Continual and accurate measurement of bath temperature, ph, and bath solution level is important. Evaporation will reduce bath volume and give false indication of actual concentration. Add DI water as needed during the plating cycle to keep solution at proper level. Only use reagent grade ammonium hydroxide (50% concentration or less) and reagent grade sulfuric acid (25% concentration or less) to adjust the ph of bath. Air quality in plating shop should be clean and ventilated. Do not draw dirty air over plating or other tanks. Deposition rate depends upon operating temperature, bath loading, ph, agitation, and age of the bath. The plating rate at the preferred conditions for a new bath is listed on the Parameters Page for each system. Plating thickness can be determined by various methods including witness panel measurements, electronic devices, and cross section analysis. SOLUTION MAINTENANCE The plating bath is maintained by simple analytical procedures and subsequent replenishment. Nickel Metal Concentration o The following reagents are required: Concentrated ammonium hydroxide, Murexide indicator mix (2 grams murexide powder in 100 grams sodium chloride), and 0.0575M E.D.T.A. solution. o Analysis procedure: Pipette 10 ml of plating solution into a 250 ml Erlenmeyer flask. Add 100 ml of deionized water, 10 ml of concentrated ammonium hydroxide, and about 0.2 grams murexide indicator mixture and mix well. Titrate immediately with standard 0.0575M E.D.T.A. solution to purple endpoint, and record the number of ml of the E.D.T.A. solution used. The grams/liter of nickel metal in the bath = ml of 0.0575M EDTA used x 0.336. Replenishment o Replenish according to the Parameters Page for the system in use, based upon the ml of E.D.T.A. consumed in the titration procedure above. o If the nickel metal concentration in the bath falls below 80%, it is best to replenish in two steps to avoid over-stabilization. o Each replenishment component should be added separately to the bath. o All replenishments should be made slowly with good mixing, and not directly over the workload. Sodium Hypophosphite Concentration o With proper make-up and replenishment of the bath, the concentration of sodium hypophosphite should be self regulating. From time to time, however, it is recommended that this analysis for sodium hypophosphite be done independently to assure the bath is at its optimum concentration. o The following reagents are required: 6N HCl solution, 0.1N iodine solution, 0.1N sodium thiosulfate solution, and standard starch indicator. o Analysis procedure: Pipette 5 ml of the plating bath into a 250 ml Erlenmeyer or iodine flask. Add 25 ml of the 6N HCl to the sample. Pipette 50 ml of 0.1N iodine solution to the sample. Stopper the flask and let it stand in the dark for 30 minutes.

Titrate the sample with 0.1N sodium thiosulfate solution, adding starch indicator when a pale yellow color is reached. Continue to carefully titrate until the purple starch color disappears. Calculate the hypophosphite content of the plating solution from the volume of thiosulfate solution used: 5 (0.1 x ml thio used) = meq hypophosphite in solution (meq hypo) x (10.5) = g/l of hypophosphite POST TREATMENT Consult your Surface Technology, Inc. Technical Support Representative for any assistance on the treatment of your parts following plating, such as rinsing, passivation, heat treatment, mechanical finishing, stripping, etc. WASTE TREATMENT Consult your Surface Technology, Inc. Technical Support Representative for any assistance on the proper treatment/disposal methods of the used plating bath. All usage and waste treatment of the chemicals associated with this process must comply with all federal, state, and local regulations for health, environmental and safety requirements. TROUBLE SHOOTING The following are problems that may occur in plating, plus a listing of possible causes and suggested remedies. Consult your Surface Technology, Inc. Technical Support Representative for any additional trouble shooting and resolution assistance. Skip plating, pitting, edge pull-back, step plating, dark or laminar deposit o See: 1, 2, 3, 8, 11 Roughness in deposit o See: 4, 5, 6, 7, 11 Streaks in deposit o See: 1, 3, 8, 9, 11 Dull or Matte Deposit o See: 1, 3, 10, 11, 14 Poor adhesion o See: 1, 14, 15 Poor corrosion and/or chemical resistance o See: 1, 3, 4, 12, 13, 14 Slow Plating Rate o See: 2, 3, 5, 8, 9, 10, 11, 14 Fast Plating Rate o See: 4, 6, 14 Short Bath Life o See: 2, 3, 10, 11, 14, 15 Possible Causes/Remedies: 1. Improper Pretreatment - Temperature should be checked as well as purity and concentration of cleaner, activator, and other pretreatment solutions. Some metals and alloys, such as leaded steels, brasses, copper, aluminum and magnesium, require special preparation. Rinsing, temperature and rinsing time should be checked. Consider using an electro-cleaning, ultrasonic cleaning, and/or other methods of cleaning. Minimize transfer times between pretreatment steps. Consider a double zincate process for aluminum work pieces. 2. Over stabilization of bath - Bath should be dummied or discarded and replaced. Review replenishment history. Insure adequate work load in the bath, and add additional surface area if needed. 3. Chemical contamination - Bath should be dummied or discarded and replaced. Insure no sources of nitric acid, heavy metal or other contamination. Use only proper quality deionized water. Avoid drag-in.

4. Particulate contamination from solid particles; i.e. dust, loose nickel or metal chips - Avoid contamination and/or improve workload cleaning and rinsing, and bath filtration. Demagnetize ferromagnetic substrates if possible. Use only proper quality DI water. 5. Excessive solution replenishment while work is being plated Replenishments should be added slowly and mixed thoroughly, as far away from work piece(s) as possible. 6. Low stabilizer content. Increase the stabilizer content in the plating bath. 7. Only one side of work affected - Agitation around work pieces should be increased and/or work pieces should be rotated while plating. 8. Improper agitation - Agitation around work pieces should be improved and/or work pieces should be rotated while plating. 9. Low surface area - Surface area should be increased to recommended range. 10. Bath very old - Bath should be discarded, and new bath prepared. 11. Bath Imbalance - Nickel and reducer should be checked and bath adjusted. 12. Improper phosphorous content in the deposit Adjust plating bath parameters or replace with alternative nickel-phosphorous alloy plating bath. 13. Pitting in base metal and/or deposit Inspect base metal and remedy plating bath as needed. 14. Poor bath control - Uniform temperature should be maintained, ph and replenishment controlled. 15. Zincate build up in plating bath - Bath should be used for non-aluminum parts or discarded. Double zincate processing will reduce the rate of zinc contamination. SURFACE TECHNOLOGY, INC. Surface Technology, Inc. offers a full line of proprietary electroless nickel plating solutions and coating services including low, medium, high phosphorous, nickel-boron, and composites with diamond, PTFE, silicon carbide, boron nitride, identification/authentication, and other materials. All solutions are formulated to the strictest specifications for quality and consistency and are available in NiPLATE TM and ADDPLATE TM packaging options. To compliment its line of plating solutions, Surface Technology, Inc. offers a wide array of pretreatment and waste-treatment chemicals; systems for plating on plastics; nickel sulfate and sodium hypophosphite; nickel strippers; consulting services and contract research and development projects. Surface Technology, Inc. holds more than ninety U.S. and foreign patents, which have helped establish STI s global reputation as an innovative leader in the metal finishing industry. This strength has resulted in over forty license agreements with companies around the world including: Allied-Kelite, Atotech, Cookson Electronics-Enthone, Coventya, Electrochemicals, ESK, Okuno, OMG-Fidelity, Hitachi, IBM, Lea Ronal, MacDermid, Olin Hunt, Q&M, Rohm and Haas, Schering, Shipley, SurTec, Schlotter, Uyemura, and many others. WARRANTY We warrant our goods to conform to our standard specifications. This Warranty is in lieu of any and all other warranties or guarantees and our obligation hereunder for breach of such warranty is limited to either refund of the purchase price or replacement of said goods, as we may elect. We make no other warranties, express or implied, including those of merchantability and fitness for a particular purpose. We believe that the statements, technical information and recommendations contained herein are reliable, but they are given without warranty or guarantee of any kind except as specified above. Beyond that specified above we assume no responsibility for any loss, damage or expense, direct or consequential, arising out of the use of, or inability to use, our goods. Their quality and suitability for any particular purpose or use should be confirmed by the user's own tests. Use of this product may be covered by one or more of the following US Patents: 5,863,616; 5,834,065; 6,306,466; 7,744,685; 8,147,601 and/or others pending.. NiPLATE TM and ADDPLATE TM are Trademarks of Surface Technology, Inc... Composite Diamond Coating and TraceCoat are Registered Trademarks of Surface Technology, Inc.

NiPLATE 100 PARAMETERS PAGE Aug-13 SURFACE TECHNOLOGY, INC 105 North Gold Drive, Robbinsville, NJ 08691 Phone - 609-259-0099; FAX 609-259-0077 www.surfacetechnology.com info@surfacetechnology.com The 100 system is an economical fully bright electroless nickel process designed to deposit a uniform, medium phosphorous-nickel alloy. The NiPLATETM 100 system is supplied in three liquid concentrates: NiPLATETM 100 A for bath make-up and replenishment, NiPLATETM 100 B for bath make-up, and NiPLATETM 100 C for replenishment. Bath Make-Up Parameters Page Instructions Volume = 100 Gallons 1) Insert desired volume units in the yellow cell 2) Insert the bath volume in the green cell NiPlate 100 A 5 Gallons 3) Chemical usage values will be automatically calculated NiPlate 100 B 15 Gallons DI Water Balance Instructions: Fill a cleaned tank with DI water about half way. Add the NiPlate 100 B with good mixing Add the NiPlate 100 A with good mixing Add DI water to final bath level Adjust ph to the desired level Heat and use according to the specified conditions IMPERIAL METRIC Operating Conditions Range Optimum Units Range Optimum Units Temperature 185-198 190 ºF 85-92 88 ºC ph 4.6-5.2 4.8 ph 4.6-5.2 4.8 Bath Loading 0.3-1.0 0.6 ft 2 /gal 0.75-2.5 1.5 dm 2 /l Nickel Metal Concentration 0.65-0.85 0.8 oz/gal 4.9-6.4 6 g/l Hypophosphite Concentration 3.5-4.5 4 oz/gal 26.3-33.8 30 g/l Plating Rate 0.8-0.9 mils/hr 20-22 microns/hr Agitation Mechanical or Filtered Air Mechanical or Filtered Air Filtration 10 micron or finer 10 micron or finer Replenishment ml 0.0575M EDTA consumed 17.8 16.9 16 15.1 14.2 13.4 12.5 g/l nickel metal present 6 5.7 5.4 5.1 4.8 4.5 4.2 % nickel metal present 100 95 90 85 80 75 70 NiPlate 100 A to add Gallons 0 0.25 0.5 0.75 1 1.25 1.5 NiPlate 100 C to add Gallons 0 0.5 1 1.5 2 2.5 3 TYPICAL DEPOSIT PROPERTIES SYSTEM FEATURES Phosphorus Content 6-9% by wt. Fully bright deposit Hardness: Consistent deposit properties As plated 550 VHN 100 Excellent economy of use Heat treated 1 hr. @ 400C 900 VHN 100 Corrosion resistance Salt Spray (ASTM-B-117) 90-100 hrs. Outstanding stability Stress slightly tensile Ease of use Magnetic Properties slightly magnetic Long bath life Deposition rate 0.8 0.9 mil / hour Meets MIL-C-26074D and AMS 2404C