Work surface solutions for the modern laboratory

Similar documents
SECTION TRESPA ATHLON SOLID COMPOSITE CASEWORK

TRESPA TOPLAB SCIENTIFIC SURFACE SOLUTIONS

SECTION Epoxy Work Surfaces and Sinks

SECTION LABORATORY METAL CASEWORK and SECTION Laboratory Work Surfaces

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

CONTENTS. B. System Design and Performance Requirements

Work Surface Specification

INDEX. I. About Technical Furniture Trading III. Laboratory furniture Work benches & Cabinets Cabinet Systems Work tops.

Architectural Specifications, Section Phenolic Lockers

TECHNICAL FURNITURE INDUSTRIES L.L.C. Ideal fit outs for great experiments.

Available from: Freeform Laminates 2002 Ltd 11 Watts Road, PO Box 11030, Christchurch 8042 tel: fax:

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

SECTION RESILIENT SHEET FLOORING

SECTION MANUFACTURED CASEWORK. A. This section provides standards for manufactured casework.

PH6000. Key Features

SECTION PLASTIC SURFACING

SECTION PHENOLIC LOCKERS AND BENCHES. B. Section Gypsum Board Area Separation Wall Assemblies.

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

The purpose of this guide specification is to assist the specifier in correctly specifying solid surface countertops including sinks and backsplashes.

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

ACCU TEC MANUFACTURING, INC 1027 SOUTH LINWOOD AVE SANTA ANA, CA FAX Solid Phenolic Lockers

ADDENDUM NO. 1. Bidders are hereby informed that the Construction Plans and/or Specifications are modified as follows:

SECTION SOLID SURFACE COUNTERTOPS. Display hidden notes to specifier. (Don't know how? Click Here)

Phenolic Exterior Wall Cladding

new casework tailored for your new lab

Framed Decorative Panel Systems

MRXL4 CR6 Surface Requirements: XNS, NS, M, S; Special Requirements: NO PART 1 : GENERAL

SECTION DECORATIVE PLASTIC LAMINATE

SECTION EPOXY RESIN LABORATORY WORKSURFACES V1.1

workstationindustries.com Made in the USA

ThermalShell Modular Insulated Pre-Cast Panels

Engineered Honeycomb Solutions and Services. Honeycomb Panels

Decorative Fiberglass Reinforced Wall Panels

SECTION GLASS FIBER REINFORCED GYPSUM FABRICATIONS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION SOLID SURFACE FABRICATIONS

Guide Specification SECTION QUARTZ AGGLOMERATE COUNTERTOPS

Schools and nurseries. Description of furniture

EPOXY Work Surface Specification

2018 Flooring Specification - Tile Set Method TECTURA DESIGNS CEMENT TERRAZZO TILES

Nudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

Epoxy Resin Comparison

A. Stonewood: Solid phenolic panels for interior wall cladding of commercial and institutional buildings.

SPECIFICATION GUIDELINE

Master Specifications for Microcotta November 2017

SECTION Paper-Composite Countertops PART 1: GENERAL

Desco Granite Flooring Specifications

Guide Specification SECTION QUARTZ AGGLOMERATE COUNTERTOPS

Section QUARTZ SURFACING COUNTERTOPS

High-performance structural cement-bonded particle board (CBPB)

SECTION DECORATIVE STAINLESS STEEL DRAINS AND GRATES

Marlite Guide Specification 2/24/2017 Surface Systems - MAP375 System SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

SECTION GYPSUM BOARD

SECTION (06415) - PLASTIC COUNTERTOPS

10331 Date Street Murrieta, CA SECTION HYBRID LAMINATE LOCKERS W/ PHENOLIC DOORS

HIGH PRESSURE LAMINATE CLADDING PANELS SPECIFICATION V1.0

SECTION SOUND-ABSORPTIVE PANELS

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

TECHNICAL DATA Wilsonart Chalkboard Laminate. 1. Manufacturer

HPL CSI 3-PART SPECIFICATION FORM

CONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS.

PArtitioning systems. Proudly Manufactured in Australia by Central Tablelands Commercial Industries

SECTION QUARTZ SURFACE FABRICATIONS

Product Guide Specification

Wood and Plastic Laminate Casework Latest revision: October 23, 2014

SECTION PLASTIC-LAMINATE-CLAD COUNTERTOPS

East Central College

SPECIFICATION GUIDELINE

D300. By Actiu.

Desco Quartz Cremona Specifications

TECHNICAL BULLETIN October 5, 2007

SECTION FIBERGLASS SANDWICH PANEL ASSEMBLIES

Arborite ColorEdge is available in a partial range of Arborite solid colors, patterns and textures.

DIVISION 6 SOLID SURFACE FABRICATIONS SECTION 06650

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

TECHNICAL MANUAL V

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION Fiber Reinforced Stucco 1

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Guideline Specifications GORDON MARQUIS LINEAR CEILING PANEL SYSTEMS

Product Guide Specification

First Class Building Products, Inc.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

SECTION SECURITY PROTECTION PART 1 GENERAL

TECHNICAL MANUAL V

TO THE DESIGNER. Respectfully, TFC Canopy, a Division of Centurion Industries, Inc. Bob Patterson President, TFC Canopy

University Apartments on Brooklyn PROJECT MANUAL

Standard sheet size 3660 x 1610mm, 4200 x 1860mm and 4200 x 1610mm (Gloss decors only) Available to special order 4200 x 1860mm

Feeler, S. Architects January 16, 2015

SECTION METAL EQUIPMENT LOCKERS

Worktop postformed laminated th. 28 mm self supporting

PRODUCT SPECIFICATIONS

SECTION ROUGH CARPENTRY

VITAL. By I+D+i Actiu.

Thermal Systems KWC Ltd. Telephone: (403) Avenue N.E. Facsimile: (403)

SECTION SPLIT FACE CONCRETE MASONRY UNITS

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION RESIDENTIAL CASEWORK

Transcription:

ABOUT US Counter Reaction was established to answer the demand for an independent source for fabricated work surface material and accessories to the laboratory industry. We provide our distribution network with Trespa TopLabBASE & TopLabVERTICAL for architectural interior applications and Trespa TopLabPLUS offering a high standard of hygiene, strength and durability for diverse surroundings such as chemical, analytical and biological laboratories. We fabricate to your specifications utilizing automated CNC equipment to ensure accuracy as well as meet our strict Q.C. standards during the production process. We have strategically located our fabrication facility in the Midwest / Great Lakes area to allow us to better serve the U.S and Canadian markets. Counter Reaction strives to supply the highest quality fabricated products, delivered on time, on budget as well as establish a reputation for providing a level of customer service to our clients second to none. The partners of Counter Reaction each bring their expertise in their respective roles to make up our dynamic team with over 100 years of cumulative experience in the laboratory work surface industry. Our team is comprised of the best in the industry with the experience and working knowledge of phenolic resin products as it relates to the fabrication process. We incorporate a unique system for optimal material utilization to reduce scrap and further enhance our efficiency in our process. We put to use our years of practical experience which enables us to streamline our automated order process to provide complete accountability in the Q.C. process so we can ensure we are producing the highest quality fabricated products as we track your order through production. Counter Reaction understands the need for a quality and consistent product as it relates to tolerances such as thickness and flatness. With Trespa resin panels we can supply a superior fabricated product with stringent quality control, thus resulting in a premier product by removal of the typical issues and inconsistencies found with other products in the industry. The results will be a simpler and more efficient installation on the jobsite. This will give our customers a cost advantage in the final installed price for their projects.

TRESPA TOPLAB PLUS A CHOICE FOR CLEAN AND STERILE WORK SURFACES Today s laboratory demands compliance with rigorous codes and standards. Therefore, selecting the right material for laboratory worktops and furniture is of crucial importance because tests and experiments depend on non-contaminated environments. COLOR COLLECTION TOPLAB PLUS Developed especially for laboratory environments, Trespa TopLabPLUS remains aesthetically pleasing while offering a high standard of hygiene, strength and durability for diverse surroundings such as chemical, analytical and biological laboratories. Trespa s underlying technology transforms wood-based fibers with thermosetting resins, under high pressure and at high temperatures, into robust compact laminate panels that meet the most challenging specifications. Trespa s unique in-house technology, Electron Beam Curing (EBC), ensures that each panel surface is easy to clean and resistant to a large number of aggressive chemicals. Benefits: Clean surface Chemical resistance Antimicrobial performance Non-Porous surfaces and edges Design flexibility Adaptable for field modifications Respect for our environment PEFC Certification FSC Certification GREENGUARD Gold Certification Panel size: 6' x 8' 5' x 10' Panel thickness: 1/2" / 13mm 5/8" / 16mm 3/4" / 20mm* 1"/ 25mm* Finish Crystal (smooth) *In Stock material Black & Silver Grey colors T03.0.0 White T18.0.1 Mystic White T03.1.0 Pastel Grey T30.0.1 Polar Green T70.0.0 Slate Grey T09.3.4 Canyon Red T05.0.1 Limestone Yellow T21.1.1 Glacier Blue T03.4.0 Silver Grey D02.1.0 Pastel Grey/Silver T90.0.0 Black

TRESPA TOPLAB BASE A SOLID AND DURABLE INTERIOR SOLUTION Engineered for lasting good looks in the most demanding interior applications, Trespa TopLabBASE is a decorative high-pressure compact laminate (HPL) with a melamine surface. Trespa TopLabBASE underlying technology transforms wood-based fibres with thermosetting resins, under high pressure and at high temperatures, into robust panels that meet the most exacting specifications. Benefits: Exceptional appearance Assured performance Impact resistant Scratch and wear resistant Moisture and mould resistant Low maintenance Solid and sturdy Environmental considerations COLOR COLLECTION TOPLAB BASE E0-00 White E2-10 Paper White E25-01 Icey Blue E3-01 Sand S0-00 White E0-02 Silver Grey S25-01 Icey Blue S3-01 Sand E0-015 Pastel Grey S0-02 Silver Grey E17-30 Heaven Blue W73-01 Beech S0-015 Pastel Grey E0-04 Mid Grey E17-32 Powder Blue W74-01 Oak Panel size: 6' x 8' 5' x 10' E20-12 Aquamarine S20-12 Aquamarine W82-03 Verona Walnut W85-02 Pear Panel thickness: 1/4" / 6mm 5/16" / 8mm 3/8" / 10mm 1/2" / 13mm 5/8" / 16mm 3/4" / 19/20mm* 1" / 25mm* S17-32 Powder Blue E17-52 Aqua Blue E0-09 Black C0-09 Black Craquele *In Stock material Black only color Finish Crystal (smooth)

SIMMONS EPOXY SINKS Model # Length Width Depth External Height Flange Width Thickness Waste C/L From Side Waste C/L From Rear Waste Position Radius Weight LBS A B C D E F G H R CRD3 12 8 8 9 0.8 0.24 6 4 end 1.18 9 CRD5 14 10 6 7 0.8 0.24 3.5 3.5 corner 1.18 10 CRD10 16 8 7 8 0.8 0.24 8 3 end 1.18 11 CRD15 16 12 8 9 0.8 0.24 3.5 3.5 corner 1.18 15 CRD25ADA 18 15 5 6 1.1 0.24 3.5 3.5 corner 1.18 13 CRD25 18 15 8 9 1.1 0.24 9 3 rear 1.18 17 CRD30 18 15 11 12 1.1 0.24 9 3 rear 1.18 19 CR50 24 16 8 9 0.8 0.24 12 8 corner 1.18 24 CRD55ADA 25 15 5 6 0.8 0.24 12.5 7.5 corner 1.18 17 CRD55 25 15 10 11 0.8 0.24 12.5 7.5 center 1.18 24 CRD59 28 15 12 13 0.8 0.24 3.5 3.5 corner 1.18 28 Note - All dimensions are nominal. A H B G E F D C 3.00 " R1.50 " R1.18 " 2.12 "

ACCESSORIES Stocked sinks are black All sinks include outlet, strainer and stopper. Optional overflows are available Pegboards & Stainless Steel Drip Troughs We offer standard size and custom size pegboards to fit your needs. 6-1/2" black pegs supplied as a standard, white pegs available upon request. Stainless steel drip trough includes drain tubing. Shelving We offer wall and island shelving systems. Seismic restriants available

Counter Reaction Product Specification Information TRESPA TOPLAB PLUS & TRESPA TOPLAB BASE solid composite products are specified in division sections listed below 06 20 23 - Finish Carpentry - Interior. 10 51 00 - Lockers. 10 56 00 - Shelving. 12 35 53 - Laboratory Casework. 15 40 00 - Plumbing Fixtures - epoxy sinks. REFERENCES SEFA 3-2010 Recommended Practices for Laboratory Work Surfaces WARRANTY Worktops to be warranted against delamination for 10 years. MANUFACTURERS Raw material panels manufactured by Trespa, and provided by Trespa North America, Approved fabricators that provide products may be acquired from the above. MATERIALS Basis of design: Trespa Toplab PLUS (Crystal finish), Trespa Toplab BASE (Crystal finish) Thickness: As specified on drawings or by Architect. Color: to be selected by Architect from Manufacturer s standard color palette. FABRICATION Drip grooves shall be provided on the underside at all exposed edges unless otherwise noted on Laboratory Furnishings Drawings. All exposed edges to be sanded to a smooth finish and, except as indicated below, shall be an 1/8 bevel at front top and bottom edge and at vertical corners. Curbs shall be bonded to the top of the work surface to form a square joint. Cutouts for drop-in sinks shall be routed to form openings with 3/8 minimum depth supporting flanges and such that the rim of the sink when installed is at the same level as the work surface top. Epoxy sinks, Stainless steel and polypropylene sinks shall be set in beds of silicone sealant. SOURCE QUALITY CONTROL Panels shall be of material specifically designed for laboratory work surfaces. Material shall have uniform thickness (+0.03 ) and flatness (maximum difference of 0.03 ) for 10 foot span. Panels to be U.L. registered and labeled for quality consistency. Chemical Resistance: Evaluation of chemical resistance is based on SEFA 3-2010 Laboratory Work Surfaces standard list of 49 chemicals / concentrations, their required methods of testing (24 hour surface test) and their minimum acceptable results as a means of establishing a minimum acceptable level of performance for all exposed and semi-exposed surfaces. Performance requirements: Modulus of elasticity: 1,500,000 psi minimum. Shear strength: 2000 psi minimum. Compressive strength: 24,000 psi minimum. Weight: 93 lbs. per cubic foot maximum. Flame spread (ASTM E-84): Class 1A (25). Non-porous surface and edges. Will not support micro-organic growth. Will not support oxidation of material surface PROTECTION After installation, the General Contractor shall protect the worktops from damage. The tops shall be kept free from paint, plaster, cement scratches, or any other destructive forces.

www.counterreaction.net 46915 Liberty Dr., Wixom, MI 48393 248.624.7900 Fax 248.624.7901 For estimates or orders send info to: drawings@counterreaction.net Sales contact: Michael J. Harris 517.861.7559