PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Similar documents
SECTION METAL STUDENT LOCKERS

SECTION METAL ATHLETIC LOCKERS

SECTION METAL ATHLETIC LOCKERS

SECTION METAL EQUIPMENT LOCKERS

HALLOWELL FORT KNOX Modular Utility Storage and Workbench System Specifications

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

SECTION METAL LOCKERS

WEC Manufacturing Phone: (901) Website: Itswec.com

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

1. Standard two tier metal lockers and metal base.

Hobby Parking Office HOU/ Proj./ No. 738 Houston, Texas 100% Bid and Construction Documents- Addendum #3, January 27, 2017

Specification Section Title Notation A Product Data Approved as Noted B Shop Drawings Approved as Noted

WEC Manufacturing Phone: (901) Website: Itswec.com

BID # ELLIS MIDDLE LOCKERS

1. Supply, delivery, engineering and installation of new storage equipment.

SECTION PLASTIC LOCKERS. A. ADAAG - Americans with Disabilities Act, Accessibility Guidelines.

10331 Date Street Murrieta, CA SECTION HYBRID LAMINATE LOCKERS W/ PHENOLIC DOORS

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

Architectural Specifications, Section Phenolic Lockers

SECTION ACCORDION FOLDING PARTITIONS

Solid HDPE Plastic Lockers ROYAL LOCKERS

SECTION PHENOLIC LOCKERS AND BENCHES. B. Section Gypsum Board Area Separation Wall Assemblies.

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION MISCELLANEOUS METALS

1. High bay shelving units, fabrication and installation including leveling.

SECTION IMPACT RESISTANT WALL PROTECTION

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

Hamilton International Air Cargo Logistics Facility Section November 2014 Page 1 of 4

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

1. Include plans, elevations, sections, details, and attachments to other work.

Division 11 - Equipment Section 11401

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

1. Seismic Loads: Reference structural drawings.

SECTION / HEAVY DUTY WIRE MESH WINDOW GUARDS

SECTION ACCESS DOORS AND FRAMES

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

PH6000. Key Features

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

SECTION MISCELLANEOUS METALS THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION MISCELLANEOUS AND ORNAMENTAL IRON

SECTION ACCESS DOORS AND FRAMES

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

Architectural Roof and Wall Products Guide Specifications

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

SECTION ORNAMENTAL WELDED STEEL FENCING

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

Aluminum Perforated Rolling Door

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

1. Include construction details, materials, individual components and profiles, and finishes.

SECTION METAL STAIRS

SECTION ALUMINUM HANDRAIL SYSTEMS

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

Construction Standards PAGE

HOTEL SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

ACCU TEC MANUFACTURING, INC 1027 SOUTH LINWOOD AVE SANTA ANA, CA FAX Solid Phenolic Lockers

1. Bullet resistant hollow metal door and frame assemblies tested in accordance with UL 7 52 and in compliance with the following:

Architectural Roof and Wall Products Guide Specifications

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

UNISTRUT CORPORATION GENERAL NOTES 1. THIS UNISTRUT SUPPORT SYSTEM IS DESIGNED TO SUPPORT A MAXIMUM UNIFORM LOAD OF PSF.

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Architectural Wall Products Guide Specifications

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION CHAIN LINK FENCES AND GATES (PARK)

SECTION INDUSTRIAL ACCESS / INSPECTION HATCH. A. Industrial Access / Inspection Hatch: Model AH-710

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

SECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS

SECTION TRESPA ATHLON SOLID COMPOSITE CASEWORK


SECTION PERFORATED METAL. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION ENTRANCE FLOOR GRILLES SPECIFICATIONS

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

C. Related Sections: [Sections in Division 9 Finishes, relating to finish floor and base materials]

DETAILED METAL DOOR SPECIFICATION. UNIVERSITY CONTACT: Mark Golden, Supervisor of Structural Services (302)

SECTION ORNAMENTAL ALUMINUM FENCING

A. Access doors and frames are part of an access door and frame allowance.

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

Bradley Lenox Plastic Lockers And Benches

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

Rutherford County Board of Education

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

B. Provide fire-rated access doors where indicated or scheduled.

SECTION DETENTION WINDOW SCREENS. 1. Detention screens for interior and exterior installations at exterior windows in existing buildings.

Solid Plastic Tufftec 2.0 Lockers

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

H D P SOLID PHENOLIC FLOOR BRACED COMPARTMENTS SECTION FB TOILET PARTITIONS

SECTION METAL STAIRS

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

SECTION HVAC GRAVITY VENTILATORS

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

SECTIONS * CUSTOM WOOD VENEER ATHLETIC LOCKERS

220 E. General Robinson St. Pittsburgh, PA fax

SECTION PREFABRICATED SHOWER COMPARTMENTS

Transcription:

SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections apply to this section. B. DESCRIPTION: Furnish and install Marquis-Heavy Duty Knock-Down Corridor Lockers, complete as shown and specified per the contract documents. Furnish and install Marquis-Heavy Duty Ventilated Knock-Down Athletic Lockers, complete as shown and specified per the contract documents. C. RELATED WORK SPECIFIED ELSEWHERE: 1.02 QUALITY ASSURANCE 1. Division 3 Section Cast-In-Place Concrete for concrete locker bases. Bases to be installed by General Contractor coordinate requirements with General Contractor. 2. Division 6 Section Miscellaneous Carpentry for wood furring. Any wood furring required to be installed by General Contractor coordinate requirements with General Contractor. A. MANUFACTURING STANDARD: Provide metal lockers that are standard products of a single manufacturer, with interchangeable like parts. Include necessary mounting accessories, fittings, and fastenings. B. FABRICATOR QUALIFICATIONS: Firm experience (minimum 5 years) in successfully producing the type of metal lockers indicated for this project, with sufficient production capacity to produce required units without causing delay in the work. C. INSTALLER QUALIFICATIONS: Engage an experienced (minimum 5 years) installer who has successfully completed installation of the type of metal lockers and extent to that indicated for this project. D. GREENGUARD CERTIFICATION: Lockers shall be GREENGUARD Children & Schools Certified SM to be approved for this project. 1.03 SUBMITTALS A. GENERAL: - SUBMITTALS B. SHOP DRAWINGS: Submit drawings showing locker types, sizes, quantities, including all necessary details relating to anchoring, trim installation and relationship to adjacent surfaces. C. COLOR CHARTS: Provide color charts showing manufacturer's full range available colors (minimum 24). Provide metal samples if requested. Architect to select from manufacturers full range of selections. Metal Student Lockers 10505-1

D. NUMBERING: Locker numbering sequence will be provided by the approving authority and noted on approved shop drawings returned to the locker contractor. 1.04 PRODUCT HANDLING A. GENERAL: All work shall be fabricated in ample time so as to not delay construction process. B. DELIVERY: All materials shall be delivered to the site at such a time as required for proper coordination of the work. Materials are to be received in the manufacturer's original, unopened packages and shall bear the manufacturer's label. C. STORAGE: Store all materials in a dry and well ventilated place adequately protected from the elements. 1.05 GUARANTEE A. WARRANTY: Warranty shall be a minimum of two years on both materials and workmanship PART 2 - PRODUCTS 2.01 MATERIALS A. AVAILABLE MANUFACTURERS: Provide all lockers and related accessories through one source from a single manufacturer. TYPES A & B: Basis of design shall be Marquis -Heavy Duty Student Knock-Down Corridor Lockers as manufactured by List Industries. TYPE C: Basis of design shall be Marquis-Heavy Duty Ventilated Athletic Lockers as manufactured by List Industries. Subject to compliance with the design, material, method of fabrication and installation as required in this specification section or modified as shown on drawings, the following manufacturers products are acceptable. Manufacturer s other than the ones listed below will not be accepted B. STEEL: C. FASTENERS: D. EQUIPMENT: 1. LIST Industries (Basis of Design) 2. General Storage Systems 3. DeBourgh Mfg 1. Steel Sheet: All sheet steel used in fabrication shall be prime grade free from scale and imperfections and capable of taking a heavy coat of high gloss baked enamel. 1. General: Cadmium, zinc or nickel plated steel; bolt heads, slotless type; self-locking nuts or lock washers. 1. Hardware: Hooks and hang rods of cadmium plated or zinc plated steel or cast aluminum. Metal Student Lockers 10505-2

2.02 FABRICATION 2. Handle: Seamless drawn stainless steel recessed handle. 3. Number Plates: To be polished aluminum with not less that 3/8" high etched numbers attached to door with two aluminum rivets. 4. Hat Shelves, Horizontal Intermediate Shelves and Bottoms: Shall be 16 gauge cold rolled sheet steel. 24 gauge will not be accepted. A. GENERAL (TYPE A & B): Lockers shall be "Marquis -Heavy Duty Student Knock-Down Corridor Lockers " as manufactured by LIST Industries or approved equal. Fabricate lockers square, rigid and without warp, with metal faces flat and free from dents or distortion. Make all exposed metal edges safe to touch. Weld frame members together to form rigid, one-piece structure. Weld, bolt, or rivet other joints and connections as standard with manufacturer. Grind exposed welds flush. Do not expose bolts or rivet heads on fronts of locker doors or frames except for fastening of number plates and recessed handle. GENERAL (TYPE C): Lockers shall be "Marquis-Heavy Duty Ventilated Athletic Lockers" as manufactured by LIST Industries or approved equal. Fabricate lockers square, rigid and without warp, with metal faces flat and free from dents or distortion. Make all exposed metal edges safe to touch. Weld frame members together to form rigid, one-piece structure. Weld, bolt, or rivet other joints and connections as standard with manufacturer. Grind exposed welds flush. Do not expose bolts or rivet heads on fronts of locker doors or frames except for fastening of number plates and recessed handle. B. FINISH: All locker parts to be cleaned and coated after fabrication with a seven stage zinc/iron phosphate solution to inhibit corrosion, followed by a coat of high grade enamel electrostatically sprayed and baked at 325 degrees Fahrenheit for a minimum of 30 minutes to provide a tough durable finish. Color to be selected from manufacturer's standard list of colors. Interior components to be painted #729 Parchment. Two-Tone Color Combination: Shall be at no additional cost with the locker frame and trim chosen from one color and the doors may be one of any other color chosen from manufacturers standard selection. C. LOCKER VENTILATION SCHEDULE (TYPE A & B): 1. Doors: Shall be plain (non-louvered). Wardrobe doors shall include ventilating perforations in the top and bottom door flanges. 2. Sides: Locker sides shall be solid. 3. Backs, tops, bottoms, and intermediate shelves shall be solid. LOCKER VENTILATION SCHEDULE (TYPE C): 1. Doors: Wardrobe doors 20 high and higher to be perforated with 5/8 x 1 ½ diamonds. 2. Sides: Locker sides to be perforated with 5/8 x 1 ½ diamonds. Sides to be solid side sheets at corners and at filler locations to prevent small items from falling into voids. Metal Student Lockers 10505-3

3. Backs, tops, bottoms, and intermediate shelves shall be solid. to D. LOCKER FRAME: Fabricate of 16 gauge (minimum) channels, with integral continuous door stop/strike formed on both latch and hinge side vertical members. Cross frame members of 16 gauge channel shapes, including intermediate cross frame members on double and triple tier (frames with doors over 18" high) lockers shall be securely welded to the vertical framing members to ensure rigidity. Rubber bumpers shall be provided cushion door closing. E. MARQUIS HDC DOOR (TYPE A & B): Doors to be fabricated from single sheet prime 14 gauge with single bends at top and bottom and double bends at the sides. Doors shall include a 3" wide 18 gauge full height channel door stiffener MIG welded to the hinge side of the door as well as to the top and bottom door return bends and spot welded to the inside of door face to form a rigid torque-free box reinforcement for the door. Doors to be solid. MARQUIS HDV DOOR (TYPE C): Doors to be fabricated from single sheet prime 14 gauge with single bends at top and bottom and double bends at the sides. Doors shall include a 3" wide 18 gauge full height channel door stiffener MIG welded to the hinge side of the door as well as to the top and bottom door return bends and spot welded to the inside of door face to form a rigid torque-free box reinforcement for the door. Doors to be perforated with a 5/8 x 1 ½ diamond pattern. F. MARQUIS DEEP-DRAWN SEAMLESS STAINLESS STEEL RECESSED HANDLE: All doors shall have a seamless drawn stainless steel recessed handle shaped to receive a padlock or built-in combination lock. The recessed handle shall be deep enough to have the lock be completely flush with the outer door face. Folded recessed cups will not be accepted. G. MARQUIS HDV DOOR LATCH ASSEMBLY (TYPES A, B, & C): Doors shall be single point rigid non-moving positive latch by means of a heavy 11 gauge (minimum) latch securely welded to the 16 gauge vertical frame member at both the continuous door strike as well as the area where the frame is fastened to the side panel to prevent the latch and frame from twisting. The latch assembly must be made of a single piece of steel and have a padlock loop that inserts through the recess pan. The latch must be able to accept either a padlock or built-in combination lock. A pry resistant lug which inserts into the door shall be an integral part of the 11 gauge latch. A rubber bumper shall be securely attached to the latch. H. DOOR HINGES (TYPES A, B, & C): Shall be a 16 gauge full height piano hinge. I. MARQUIS HDC LOCKER BODY (TYPES A & B): Fabricate backs of 18 gauge (minimum) solid sheet, sides of 16 gauge (minimum) sheet steel with double flanged connections extending full height. Sides to be solid. Form top, bottom and intermediate tier dividers of 16 gauge (minimum) solid sheet steel with single return bends at all sides. Bolt top and bottom as well as horizontal tier dividers of wardrobe openings to front horizontal frame members at not less than two places in addition to side panels. Form hat shelves at 60 and 72 high single tier lockers of 16 gauge (minimum) sheet steel with single bends at sides and back and a double bend at front. MARQUIS HDV LOCKER BODY (TYPE C): Fabricate backs of 18 gauge (minimum) solid sheet, sides of 16 gauge (minimum) sheet steel with double flanged connections extending full height. Sides to be diamond perforated for added ventilation. Form top, bottom and intermediate tier dividers of 16 gauge (minimum) solid sheet steel with single return bends at all sides. Bolt top and Metal Student Lockers 10505-4

bottom as well as horizontal tier dividers of wardrobe openings to front horizontal frame members at not less than two places in addition to side panels. Form hat shelves at 60 and 72 high single tier lockers of 16 gauge (minimum) sheet steel with single bends at sides and back and a double bend at front. J. LOCKER ACCESSORIES: PART 3 - EXECUTION 1. Equipment: Openings 60 and 72 shall include one hat shelf, one double hook and two single hooks. Openings 20 and 24 high shall include one double hook at 12 wide and wider. Openings 9 wide shall include two single hooks only. Openings 18 high and under include no hooks. 3. Finished End Panels: Shall be "Boxed" type formed from 16 gauge cold rolled steel with 1" O.D. double bends on sides and a single bend at top and bottom with no exposed holes or bolts. Lockers with slope tops will have end panels formed with slope at top to cover the ends of the slope tops. Finish to match lockers. Provide at all exposed ends. 4. Fillers: Provide where indicated, of not less than 16 gauge sheet steel, factory fabricated and finished to match lockers. 4. Recessed Trim (TYPES A & B): Provide Manufacturer s standard 16 gauge recessed and side trim. 5. Continuous Sloped Tops (TYPE C): Provide continuous sloped tops fabricated of 16 gauge thick steel sheet. 6. Flush 4 C-Channel Locker Base (TYPES A, B, & C): For this project Metal 4 locker base must be C-Channel and Flush with the front of the lockers. Standard Z-BASE with Reveal/Set Back or 6 Legs will not be accepted. 7. Locker Room Benches : Manufacturer's standard laminated maple hardwood tops 9-1/2" wide by 1-1/4" thick, in lengths as indicated. Furnish List Industries Model No. #8032 heavy-duty cast iron pedestal supports (with concealed fasteners) not more than 6'-0" o.c., with provisions for fastening to the floor and securing to the bench. Furnish all anchorages. Apply manufacturer's standard clear coating to bench tops. Furnish benches in quantities and sizes as shown on the drawings. 8. Locks: By Owner 3.01 INSTALLATION A. GENERAL: Installation shall be in strict conformance with referenced standards, the manufacturer's written directions, as shown on the drawings and as herein specified. B. PLACEMENT: Lockers shall be set in place, plumb, level, rigid, flush and securely attached to the wall (or bolted together if back-to-back) and anchored to the floor or base according to manufacturer's specifications. Metal Student Lockers 10505-5

C. ANCHORAGE: About 48" o.c., unless otherwise recommended by manufacturer, and apply where necessary to avoid metal distortion, using concealed fasteners. Friction cups are not acceptable. D. TRIM: Sloping tops, metal fillers and boxed end panels shall be installed using concealed fasteners. Provide flush, hairline joints against adjacent surfaces. 3.02 ADJUSTMENT A. GENERAL: Upon completion of installation, inspect lockers and adjust as necessary for proper door operation. Touch-up scratches and abrasions to match original finish. PART 4 LOCKER SCHEDULE 4.01 LOCKER TYPES Type A) Heavy Duty Corridor 12 W x 18 D x 36 /72 H (Two Tier): Provide Quantities As Shown On Drawings. a) Door: 14 gauge w/ 18 gauge full height door stiffener b) Backs: Solid 18 gauge c) Latch Assembly: Single Point (No Moving Parts), Stainless Steel Deep Drawn Recessed Handle d) Door Hinges: 16 gauge Full Height Piano Hinge e) Sides: Solid 16 gauge f) Side Panels: Solid side panels at corners and at filler locations g) Base: 4 Flush Front Metal C-Channel h) Door Ventilation: plain (non louvered) i) Trim: 16 gauge 3 recessed trim j) Bottom: 16 gauge k) Shelf/Tier Divider: 16 gauge Type B) Heavy Duty Corridor 12 W x 18 D x 36 H (Single Tier): Provide Quantities As Shown On Drawings. a) Door: 14 gauge w/ 18 gauge full height door stiffener b) Backs: Solid 18 gauge c) Latch Assembly: Single Point (No Moving Parts), Stainless Steel Deep Drawn Recessed Handle d) Door Hinges: 16 gauge Full Height Piano Hinge e) Sides: Solid 16 gauge f) Side Panels: Solid side panels at corners and at filler locations g) Base: 4 Flush Front Metal C-Channel h) Door Ventilation: plain (non-louvered) i) Trim: 16 gauge 3 recessed trim j) Bottom: 16 gauge k) Shelf/Tier Divider: 16 gauge Type C) Heavy Duty Ventilated Athletic 12 W x 18 D x 24 /72 (Three Tier): Provide Quantities As Shown On Drawings. a) Door: 14 gauge w/ 18 gauge full height door stiffener b) Backs: Solid 18 gauge c) Latch Assembly: Single Point (No Moving Parts), Stainless Steel Deep Drawn Recessed Handle d) Door Hinges: 16 gauge Full Height Piano Hinge e) Sides: Diamond Perforation f) Side Panels: Solid side panels at corners and at filler locations Metal Student Lockers 10505-6

g) Base: 4 Flush Front Metal C-Channel h) Door Ventilation: Diamond Perforation i) Top: 16 gauge Continuous Sloped Tops j) Bottom: 16 gauge k) Shelf/Tier Divider: 16 gauge END OF SECTION 10505 Metal Student Lockers 10505-7