Laboratory Test Results on Concrete Mixtures Containing Water-Reducing, Set-Retarding Admixtures

Similar documents
SECTION PORTLAND CEMENT CONCRETE PAVEMENT. All subsurface utilities must be inspected, tested, and accepted prior to any paving.

DIVISION 7 STRUCTURES

SPECIAL PROVISION Portland Cement Concrete

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 888 PORTLAND CEMENT CONCRETE PAVEMENT USING QC/QA.

ITEM 421 STRUCTURAL CONCRETE

PERFORMANCE-RELATED SPECIAL PROVISION FOR HIGH PERFORMANCE CONCRETE MIX DESIGNS FOR CONCRETE SUPERSTRUCTURE (Tollway)

CIVE.3100 ENGINEERING MATERIALS ASSIGNMENT #8: CONCRETE MIX PROPORTIONING

Truck Mixer, Agitator and Front Discharge Concrete Carrier. Standards. TMMB Printing

SPECIAL SPECIFICATION 3048 Permeable Concrete

Admixtures-Section 924

DIVISION II CONSTRUCTION AND MATERIAL SPECIFICATIONS SECTION 2700 STRUCTURES

Use of Class AA Concrete Modified with a High-Range Water Reducing Admixture in a Full-Depth Bridge Deck Slab US 127, Lincoln County

SECTION 434 HIGH PERFORMANCE CONCRETE (HPC)

CHAPTER 5 INSPECTION OF PLANT AND EQUIPMENT

Experimental Concrete Pavement Containing Fly Ash Admixtures [1965]

Tolerances- Section

SECTION CONTROLLED LOW STRENGTH MATERIAL

Glossary of Terms - A -

FEBFLOW STANDARD WATER REDUCING PLASTICISER FOR CONCRETE

ROAD COMMISSION FOR OAKLAND COUNTY SPECIAL PROVISION FOR QUALITY CONTROL AND ACCEPTANCE OF PORTLAND CEMENT CONCRETE

SECTION US Patent 8,857,130 B1 CAST-IN-PLACE CONCRETE WITH ARDEX CONCRETE MANAGEMENT SYSTEMS (ACMS ) EARLY MC APPLICATION

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS 2007 EDITION

SPECIAL SPECIFICATION 4491 Type CAC Concrete

SPECIAL SPECIFICATION 2042 Decorative Colored Pattern Concrete Paving

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION

DIVISION 400 CONCRETE

MATERIAL SPECIFICATION FOR CONCRETE - MATERIALS AND PRODUCTION

SECTION CAST-IN-PLACE CONCRETE

MATERIALS &. RESEARCH DIVISION. RESEARCH UPDATE Number U90-07 REPAIR OF SUBSTRUCTURE CONCRETE USING SHOTCRETE

.1 Concrete mix shall be in accordance with the following:.1 The average of all tests shall exceed 25 MPa.

SECTION 941 PRECAST REINFORCED CONCRETE BARRIERS

ENGINEERING MATERIALS Assignment #8: Concrete Mix Design

Characterization of TX Active Cement

Challenges and Opportunities

ITEM 522 PORTLAND CEMENT CONCRETE PLANTS

METHOD OF TEST FOR CEMENT CONTENT FOR PORTLAND CEMENT CONCRETE PAVEMENTS

WYOMING DEPARTMENT OF TRANSPORTATION. SUPPLEMENTARY SPECIFICATION FOR STRUCTURAL CONCRETE WITH QUALITY CONTROL and QUALITY ACCEPTANCE

QUALITY CONTROL PROGRAM FOR PRECAST CONCRETE PRODUCTS SECTION 1902 QUALITY CONTROL PROGRAM FOR PRECAST CONCRETE PRODUCTS

INTEGRALLY COLORED CONCRETE [DECORATIVE CONCRETE PAVING]

MATERIAL SPECIFICATION FOR CONCRETE - MATERIALS AND PRODUCTION

CEMENT STABILIZED SAND

SECTION ~ CURB AND SIDEWALK PART 1.00 ~ GENERAL

Experimental Case Study Demonstrating Advantages of Performance Specifications Karthik Obla 1 Fernando Rodriguez 2 and Soliman Ben Barka 3

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION OF 1990

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 888 PORTLAND CEMENT CONCRETE PAVEMENT USING QC/QA.

Standard Specification for Chemical Admixtures for Concrete 1

NRMCA is working on. Experimental Case Study Demonstrates Advantages of Performance Specifications

DIVISION 800 STRUCTURES SECTION 801 EXCAVATION AND BACKFILLING

Construction Specification 62 Grouted Rock Riprap

Chapter VI Mix Design of Concrete

SECTION CONCRETE. B. ACI 318 Building Code Requirements for Structural Concrete and Commentary

CSI MASTERFORMAT SPECIFICATIONS. krystol internal membrane (kim ) Section 03 & 07 - Integral Crystalline Waterproofing of Concrete

Comparison of Length Changes, Flexural Strengths and Compressive Strengths. Between Concrete Made with Rounded Gravel

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

SECTION 54 STRUCTURAL CONCRETE (FAA P-610) ITEM P-610 STRUCTURAL PORTLAND CEMENT CONCRETE DESCRIPTION MATERIALS

SECTION CAST IN PLACE CONCRETE FOR FLOOR SLABS ON GRADE THAT WILL RECEIVE SEMI-PERMEABLE OR IMPERMEABLE FLOOR FINISHES

Standard Specification for Chemical Admixtures for Concrete 1

Dryshake CSI Format Section 07160

Mr. Paul Falco Cellular Concrete Technologies, LLC 184 Technology Drive, Suite 200 Phone: (949)

32.02 RESPONSIBILITIES OF THE TESTING AGENCY

By CTS Cement Manufacturing Corp.

Lignite Fly Ash Concrete Highway Pavement-A 15-Year Performance History

Effects of Materials and Mixing Procedures on Air Void Characteristics of Fresh Concrete

Hydrophilic Crystalline Waterproofing of Concrete-Admixture

Drilling of grout holes will be measured for payment on the basis of the linear feet of holes actually drilled.

An Introduction to Concrete Pavements

Fundamentals of Concrete

PROPORTIONING CONCRETE MIXES

SECTION 706 AGGREGATES FOR PORTLAND CEMENT PRODUCTS SCOPE

Test 1 : Standard Slump and Flow Table Tests

715 - PRESTRESSED CONCRETE MEMBERS SECTION 715 PRESTRESSED CONCRETE MEMBERS

QUALITY CONTROL PROGRAM FOR PRECAST CONCRETE PRODUCTS SECTION 1902 QUALITY CONTROL PROGRAM FOR PRECAST CONCRETE PRODUCTS

Beyond Water-Cement Ratio and Strength. Patrick Harrison Vice President Structural Services, Inc.

Reed, Hale 1. Slag Cement Concrete for Use in Bridge Decks. August 1, Words (6 Tables = 1500 words)

Minnesota Concrete Flatwork Specifications for Local Government Agencies

METHOD OF TEST FOR EVALUATION OF SUPERPLASTICIZING ADMIXTURES FOR CONCRETE

PCC Pavement Mix Proportioning and Strength

DIVISION 6 PORTLAND CEMENT CONCRETE PAVEMENTS. Section 601. PCC PAVEMENT MIXTURES

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR QUALITY CONTROL AND ACCEPTANCE OF STRUCTURAL PRECAST CONCRETE

Standard Specification for Fiber-Reinforced Concrete 1

Chapter 6: Admixtures for Concrete (con t)

Mr. Gabriel Ojeda Fritz-Pak Corporation Phone: (214) Eastover Circle Fax: (214)

LITHOCRETE ARCHITECTURAL CONCRETE PAVING

REQUEST FOR COMMENTS UNIFORM STANDARD SPECIFICATIONS SECTION 704, "BASE AGGREGATES"

GUIDE SPECIFICATIONS For STRUCTURAL PRECAST HOLLOW CORE SLABS SECTION 03410

Mix Design and Pumped Concrete

DIVISION 400 CONCRETE

MiniFIBERS ADMIXUS TM Admixtures for Cement Containing Applications. July 2016

SPECIAL SPECIFICATION 3157 Cold Processed - Recycled Paving Material (RPM) for Use as Aggregate Base Course

Section CEMENT STABILIZED SAND

LADOTD Concrete Specifications A Glimpse into the Near Future. Zach Collier, E.I. Concrete Research Engineer

ALBERTA TRANSPORTATION TECHNICAL SERVICES BRANCH. B387 August 2017 SPECIFICATION FOR NON-SHRINK GROUTS

OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISIONS FOR SUBGRADE STABILIZATION

Mr. Jody Wall Carolina Stalite P.O. Box 186 Phone: (704)

Effect of Extending Concrete Delivery Time on Plastic and Hardened Properties of Concrete

High-Performance Concrete

STUDY OF MIX DESIGN FOR HIGH PERFORMANCE CONCRETE

SPECIAL SPECIFICATION 4703 Repair Of Impact Damaged Prestressed Concrete Bridge Beams

ITEM 421, HYDRAULIC CEMENT CONCRETE 2014 TXDOT SPECIFICATION. Andy Naranjo, P.E. Construction Division

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION OF 1990

Transcription:

Transportation Kentucky Transportation Center Research Report University of Kentucky Year 1965 Laboratory Test Results on Concrete Mixtures Containing Water-Reducing, Set-Retarding Admixtures James H. Havens Kentucky Highway Materials Research Laboratory This paper is posted at UKnowledge. https://uknowledge.uky.edu/ktc researchreports/1171

April 21, 1965 MEMORANDUM TO: FROM: SUBJECT: Harold Mays 1#1 Director of Ma~ al. ~ Jas. H. Havens ;- Director of Re arch Laboratory Test Results on Concrete Mixtures Containing Water-Reducing, Set-Retarding Admixtures C,2.4.1 H, 2. 2 In response to your request of March 4, 1965, the Concrete Section of this Division has initiated tests on nine (9) waterreducing, set-retarding admixtures delivered to this laboratory for tests in accordance with the Department's Special Provision for Set-Retarding Admixtures for Concrete, dated April 14, 1964. The properties of all concrete mixtures containing the individual admixtures were compared with those of one reference mixture containing the same cement and aggregates but without any waterreducing, set-retarding admixture. All mixtures were proportioned to be within the limits of values designated under Section I.I C-2 of the Special Provision, To date, tests for properties as outlined under Section II C-3 have been completed except the freeze-thaw tests. Freeze-thaw testing will be completed by mid June, 1965. Flexural-strength tests were not required. All mixtures contained Type I cement produced by the Louisville Cement Company, No. 6 crushed limestone produced by Central Rock Company of Lexington, and Ohio River Sand. The S.S.D. specific gravity of the limestone was 2. 72 and the S.S.D. specific gravity of the river sand was 2,64. All mixtures were proportioned to contain 37 percent fine aggregate by solid volume of the total aggregate, Mixtures were adjusted in order to maintain a constant cement factor of 6.0 bags per cubic yard. Neutralized vinsol resin was used as the air-entraining agent for each mixture. The A.E.A. was added to each mixture after approximately 20 percent of the total mix water had been added and the water-reducing, setretarding admixture was added to each test mixture after 80 to 90 percent of the total mix water had been added, Mixture designs, mixture properties, and laboratory test results are contained in Tables I and II included herein. The admixtures tested are as follows:

Mr. Harold Mays - 2 - April 21, 1965 1. Daratard - Dewey and Almy Chemical Division 2. Plastiment Liquid - Sika Chemical Corporation 3, Plastiment Powder - Sika Chemical Corporation 4. HPS-R - Hunt Process Corporation Southern 5, Eucon - The Euclid Chemical Corporation 6, Pezzoli th IIP-18 - The Master Builders Company 7. Pozzolith Low Heat - The Master Builders Company 8. Sonotard-CH 92 - Sonneborn Building Products, Inc. 9. Sonotard - 6050 - Sonneborn Building Products, Inc. Sonotard-CH92 and Sonotard-6050 detrained air to some extent in that a greater quantity of air-entraining agent was required to produce approximately the same air content in mixtures containing these admixtures than was required for the control mixture. The HPS-R admixture had little or no effect upon the air-entraining characteristics of the mixture in which it was employeed. The remaining water-reducing, set-retarding admixtures entrained air to various degrees. All powdered admixtures were pre-mixed with water to form a liquid solution. The Plastiment powder would not stay in solution, thus it was necessary to stir vigorously before its addition to the mixture. Both Pozzolith Low Heat and Pozzoli1h HP-18 had a tendancy to cake when mixed with water and considerable agitation was required in order to obtain desirable solutions. The initial setting time as determined by procedures outlined under A.S.T.M. C 403 for the control mixture was 4-1/2 hours. A sufficierit quantity of each water-reducing, set-retarding admixture was added to test mixtures to cause an increase in the in.itial setting time over that of the control mixture of 50 ~o 60 percent. Several trial mixtures were required for some of the test mixtures in order to determine the quantity of admixture necessary for the required retardation. Four of the admixtures tested failed to meet that section of the Special Provision requiring the compressive strength of the admixed concrete to be at least 10 percent greater than that of the control concrete at 3, 7, and 28 days. Admixtures failing to meet this requirement were: 1) Daratard, 2) HPS-R, 3) Eucon, and 4) Sonotard CH92. The remaining admixtures have met all requirements specified except for the durability factor. Freeze-thaw tests will be completed by mid-lune, 1965; and results of these tests will be reported at a later date. Flexural-strength tests were not required for this series of admixtures. We will continue freeze-thaw tests on specimen cast from those admixtures havtng failed the compressivestrength tests until further notification from your office, I am inclined to believe that the mandatory use of a waterreducing set-retarding admixture for the conditions as set forth under our present Special Provision for such admixtures may not be in the best interest of the Department. The required

Mr. Harold Mays - 3 - April 21, 1965 use of such admixtures may constitute an indulgence of undesirable concreting practices such as delayed finishing, re-vibration, re-finishing, postponement of curing, etc. Provision for the use of such admixtures should be made subject to request for use by the Contractor and approved by the Engineer. Permission for use of water-reducing, set-retarding admixtures should not be granted in lieu of requirements that the Contractor provide sufficient personnel and/or equipment for satisfactory performance of work under normal conditions. In further consideration of some of the problems experienced during testing of the aforementioned admixtures and upon review of literature regarding such admixtures, I am of the opinion the special provision covering set-retarding admixtures needs some modification. The requirement for an increase in the initial setting time of 50 to 60 percent relative to that of the control concrete is somewhat restrictive in that a quantity of admixture must be added to the test mixture(s) so as to provide an initial setting time of approximately 6-3/4 to 7-1/4 hours. ASTM C494 for Chemical Admixtures for Concrete provides for a delay in setting time of 1 to 3 hours over that of the control mixture. I feel the 1- to 3- hour period would be more desirable than our present 50 to 60 percent. Moreover, it would be desirable to include a clause requiring the manufacturer(s) of the admixture(s) to supply reliable recommendations regarding the dosage of their admixture to use for the conditions as set forth in the Special Provision. It should also be required that any admixtures which are to be supp 1 i ed in powder form be camp lete ly and permanently soluble in water and that the powdered admixtures be thoroughly mixed with water prior to their placement in an automatic dispenser. Provision should. also be made for the addition of the retarder at a specified time during the mixing operation. Reports indicate that the time of addition of such admixtures may appreciably affect their set-retarding and (or) airentraining characteristics of the air-entraining agent. The general consensus of opinion presented in reports devoted to such admixtures is that desirable results are generally obtained through addition of the water-reducing, set-retarding admixture at that time when approximately 80 percent of the total water has been added to the mixture--but definitely after the air-entraining agent has been added. The Special Provision should specify the order and the time of addition of the admixtures but should include a statement providing for another time of addition in cases where manufacturers recommend otherwise. A.S.T.M. C 494 lists a minimum durability factor of the test mixture(s) of 80 percent relative to that of the control mixture; whereas, the Department's current special provision

Mr. Harold Mays - 4 - April 21, 1965 requires the durability factor of the test mixture(s) be 90 percent (or greater) than that of the control mixture. I believe that we should reasonably expect no less than 100 percent relative durability. Past experience with certain set-retarding admixtures indicate that some may produce extensive bleeding; therefore, I feel the inclusion of the bleeding test is essential for this special provision, For this purpose, the increase in bleeding of the admixed mixture(s) over that of the control mixture as outlined in A.S.T.M. C 494 should be applicable. I am attaching a proposed Special Provision for Water-Reducing, Set-Retarding Admixture for Concrete for your review and comments. RDH:skb Attachments cc: Wa B. Drake S, T. Collier

TABLE I - ADMIXTURE REQUIREMENTS AND PROPERTIES OF!1IXTURES Reta.."'Cler Control 1uaratard PlastJJ!lBnt Plastllllent ill's-r Lucon.t'OZZOllth.t'OZZO_Llth i::;onotard Sonotarc Liquid Powder HP-18 Low Heat CH 92 6050 3 qater, gal /yd, 29,70 25,71 27,20 27,25 27.37 25,00 26,60 26,20 27,50 26,85 Nater, % of Control 100 86,5 91,6 91,7 92,1 84,1 89,6 88,2 92,6 90,4 NVX-Fl,Ounces 4.46 2,54 3,75 3,75 4.36 3,60 2.54 2,54 5,07 5,07 Sack Retarder, per 0 7,50 2,50 0,625 3.00 5,00 0.14 0,15 2,00 1.50 Sack flooua fl.ou. lb. fl.ou. fl.ou, lb. lb. fl.ou, fl.ou, Retardation,% 0 57,4 59,2 51.3 58,3 59,2 51.8 56,1 55.6 50.6 Slump, In, 2 2 1/2 2 1/2 2 1/2 3 2 5/8 2 2 7/8 2 1/2 2 3/4 Air Content,% 6,2 6,9 6,1 5,1 6,1 7.0 5,8 6,5 6,3 5,8 Unit Wt,,peL 146,4 145.9 146,6 148,0 146,0 145,8 147,5 146,8 146.6 ll.f7,0

TABLE II - COMPRESSIVE STRENGTH TEST DATA (Avg, of 3 each) Compressive Str.-osi Precent of Retarder 3-day 7-day 28-day 3-day 7-day 28-day Control 3756 4301 5671 - - - Daratard 4345 4778 6082 116 111 107 P1astiment Liquid 4648 5556 6790 124 129 120 Plastiment Powder 4784 5630 6771 127 131 119 HPS-R 4110 5027 6984 109 117 123 Eucon 3824 4595 5808 l.02 107 102 Pozzlitb-HP-18 5122 5665 6606 136 132 116 Pozz1itb Low Heat 4730 5813 7025 126 135 124 Sonotard CH92 4354 5079 6073 116 118 107 Sonotard 6050 5570 5757 6473 148 134 114

p R 0 p 0 s E D COMMONWEALTH OF KENTUCKY DEPARTMENT OF HIGHWAYS SPECIAL PROVISION FOR WATER-REDUCING, SET-RETARDING ADMIXTURES FOR CONCRETE This special Provision shall be applicable to individual projects only when indicated on the plans or in the pr~osal or when ordered in writing by the Engineer. 1. DESCRIPTION This Special Provision covers the requirements for materials and construction procedures for water-reducing, set-retarding admixtures to be used in the construction of concrete bridge superstructures. The Contractor shall add an approved water-reducing, set-retarding admixture to the concrete mixtures for use in spans of a continuous unit so as to permit placement and finishing of concrete in all spans in a single continuous operation, unless otherwise directed by the Engineer. Use of a 0ater-reducing, set-retarding admixture for reasons other than the preceeding stated condition shall be subject to the following conditions. When the prevailing air temperature is 75"F or higher at the time concrete is being placed, the Contractor may request permission to add an approved water-reducing, set-retarding admixture. lhe Engineer may grant permission to use such an admixture in the event con-

Page 2 of 7 ditions are such to warrant their use. Water-reducing, setretarding admixtures shall not be used in lieu of sufficient personnel and (or) equipment to perform the work satisfactorily. All water-reducing, set-retarding admixtures shall be approved by the Department prior to their use. II. MATERIALS A. General Requirements The water-reducing, set-retarding admixture may or may not exhibit air-entraining properties and may be furnished in liquid or powder form. Admixtures which are furnished in powder form shall be of such nature that they will be completely soluble when mixed with water and thereby stay in solution and not settle out. The Admixture shall be one of the following types: B, Approval (1) A calcium, sqdium potassium or amonium salt of lignosulfonic acid (2) A hydroxylated, carboxylic acid or its salts The admixture is subject to approval by the Department on evidence of its compliance with the test requirements as hereinafter specified under paragraph C-2. Acceptance shall be made on the basis of one of the following procedures: (1) Approval by the Testing Laboratory on the basis of results of tests performed on samples of material furnished by the Contractor; (2) Approval by the Department upon evidence that it has been tested by a recognized laboratory

Page 3 of 7 and found to comply with all requirements - provided that two certified copies of the test report are furnished to the Department by the laboratory; or (3) Approval by the Department upon certification by the manufacturer, furnished by the Contractor, stating that the admixture is identical in composition to a (named) admixture previously approved, When the material is to be tested by the Testing Laboratory, the Contractor shall provide the Engineer with samples of the admixture and representative job aggregates for testing at least 70 days prior to the time of use, The Contractor shall supply the manufacturer's suggested quantity of admixture to use per sack of cement to provide the specified retardation for the mixture proportions as hereinafter designated in paragraph C-2, If the admixture is to be approved on the basis of tests conducted by a recognized laboratory, the laboratory shall be one operated by a state highway department, the Bureau of Public Roads, or other cement or concrete laboratory regularly inspected by the Cement Reference Laboratory, Either before or during construction, the Engineer may require the selected admixture to be retested, C, Acceptance Tests 1, Test Data The test data shall be obtained by use of concreting materials and methods meeting the require-

Page 4 of 7 ments of the current applicable standards of the Kentucky Department of Highways, the American Association of State Highway Officials or the American Society for Testing and Materials. 2. Mixture Requirements The properties of concrete containing the admixture under test shall be compared to those properties of a reference concrete containing the same cement and aggregate, but without the admixture. Both mixtures shall have the following composition: Cement Content, bags per cubic yard Air Content, percent Fine Aggregate, percent Solid Volume of Aggregate Slump, inches 6.0+0.1 5.0 to 7.0 35 to 40 2 1/2.:: 1/2 A~ approved, air-entraining admixture shall be used if the retarder does not entrain a sufficient quantity of air. A sufficient quantity of the retarder shall be added to delay the initial setting time of the test mixture at least 1 hour but not more th~n 3 hours after the initial setting time of the reference mixture. The setting time for both mixtures shall be determined in accordance with A.S.T.M. C 403 (penetration pressure of 500 psi; temperature 73.::, 3 F). 3. Properties Concrete containing the admixture in the amount satisfying the requirements specified in paragraph C-2, when compared to the reference concrete, shall exhibit the following p~operties:

Page 5 of 7 (a) The net mixing water shall be reduced at least 5 percent, (b) The compressive strength at ages of 3, 7, and 28 days shall be increased at least 10 percento (c) The flexural strength at ages of 3, 7, and 28 days shall not be reduced. (d) The relative durability factor for the freezing and thawing test shall not be less than 100. (e) The increase in bleeding relative to the control mixture shall not exceed 5 percent of the net mixing water, Par this purpose, bleeding is that which takes place during the period subsequent to the time the pene~ tration resistance of the mortar screened from the reference mixture is equal to 100 psi and shall be expressed as a percent of the net mixing watero Tests for flexural strengths and relative durability may be required only at the option of the Department. III, CONSTRUCTION HETHODS Proportioning, mixing, and p 1 acing the concrete sha 11 be done in accordance with the applicable requirements of the Department's current Standard Specifications for Road and Bridge Construction.

Page 6 of 7 The admixture shall be delivered to the project in the manufacturer's original container(s) labeled to designate the name of the manufacturer and the contents. Acceptance tests or certifications of approval shall be required for each shipment of material. Admixtures which are supplied in powder form shall be prepared in a liquid form before addition to the concrete mixture, The admixture shall be metered accurately into the batch at the mixer by means of an automatic device and in quantities as recommended by the manufacturer or as directed by the Engineer, The admixture shall be metered into the batch after the addition of an air-entraining agent and at the time approximately 80 percent of the mix water has been metered into the batch - unless otherwise directed by the Engineer, The quantity of the admixture per batch may be adjusted, as directed by the Engineer, for the purpose of decreasing the setting time of the concrete as work progresses toward completion of each placement. The approved status of an admixture is dependent upon its satisfactory performance on the job, and tests to determine rate of hardening and strength of the concrete may be made at any time during work. IV, METHOD OF MEASUREMENT AND BASIS OF PAYMENT The water-reducing, set-retarding admixture shall not be measured for payment since the cost thereof shall be

Page 7 of 7 included in the unit price bid per cubic yard of Class A Concrete. No additonal payment shall be allowed the Contractor for any testing services furnished by him toward certification and approval of an admixture nor for delays occurring as a result of tests or due to unsatisfactory performance of the admixtures.