Structural Design of Pergola with Airfoil Louvers

Similar documents
Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL COLLEGE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2018/2019

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

Example of a modelling review Roof truss

Introduction. Structures may be classified on the basis of materials used for construction, as follows: Steel structures. Aluminium structures

Level 6 Graduate Diploma in Engineering Structural analysis

CIRCULAR TUBE COLUMNS IN HIGH STRENGTH STEEL Economical solutions for building frames

DIN EN : (E)

BS EN :2004 EN :2004 (E)

Trailer Stage. Structural design calculations. 2nd September [00]

1. BS 5950: Structural use of steelwork in building Part 1: Code of practice for design of simple and continuous construction, BSI, 1990

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Angle Cleat Base Connections

w Whittles Publishing

COMPOSITE STRUCTURES PREPARED BY : SHAMILAH

Renovation of Buildings using Steel Technologies (ROBUST)

Flexure and Serviceability Limit State

R-STEEL. RPK-N2, RPK-E2 Column shoes USER GUIDE

Lintels and Beams Engineering basis

Lintels and Beams: Engineering Basis

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

American Residential Deck Railing Design Guide

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

Chapter. Masonry Design

Concept of Prestressing

CHAPTER FIVE 5.1 MODELING OF A TEN-STOREY BUILDING

European Technical Assessment. ETA-09/0143 of 8 October English translation prepared by DIBt - Original version in German language.

CLT Structural Design Sylvain Gagnon, Eng. February 8, 2011 Vancouver

CIVL473 Fundamentals of Steel Design

JOINTS IN CONSTRUCTIONAL STEELWORK, RECENT DEVELOPMENTS IN THE NETHERLANDS S U M M A R Y

EN DK NA:2007

ECONOMIC ASPECTS OF PARTIAL STRENGTH CONNECTION IN THE DESIGN OF BRACED STEEL FRAME USING TRAPEZOID WEB PROFILED STEEL SECTIONS

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

Council on Tall Buildings

midas Gen MIDAS On-Demand Service midas Gen Advanced Webinar Steel Structure Design

Analysis of Non Composite and Composite Space Frame for Varying Support Condition

Experimental Study on Post Buckling Behaviour of Steel Plate Girder

STEEL DESIGNERS MANUAL

Verification of Welded eaves moment connection of open sections

STRUCTURAL CALCULATIONS

6. Design of Portal Frames (For class held on 20 th, 26 th and 27 th March 07)

DESIGN OF WALLS FOR SHEAR

7 LOCAL BUCKLING OF STEEL CLASS 4 SECTION BEAMS

VALLIAMMAI ENGINEERING COLLEGE

Lap shear tests of bolted and screwed ferritic stainless steel connections Stainless Steel in Structures Experts Seminar Ascot, 6-7 December 2012

BEHAVIOUR OF COLD-FORMED Z-SHAPED STEEL PURLIN IN FIRE

RPA Plate Lifting Inserts Technical Manual

SECTION ORNAMENTAL ALUMINUM FENCING

5.2 Design values of material coefficient (BS EN :2005)

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING. BEng (Hons) CIVIL ENGINEERING

Analysis and Design of Steel

Structural Behaviour and Detailing

CARES Technical Approval Report TA1-B 5065

EXPERIMENTAL AND NUMERICAL INVESTIGATION OF POLYURETHANE SANDWICH PANELS

Jurnal Teknologi STEEL WEIGHT SAVING DEVELOPED FROM SEMI- CONTINUOUS CONSTRUCTION IN MULTI-STOREY BRACED STEEL FRAME BASED ON EURO-CODE 3.

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS

Mechanical behavior and design method of weld-free steel structure with knee brace damper using square tube column

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

Technical Data Sheet. Mass 10 Mass 25 Mass 50 M AT 125. Eurocode Compliant. T E C H N I C A L D A T A S H E E T Mass 10. MU Bridging Compact Bridging

PROFILED SHEETING NP EN COLD FORMED SECTIONS STANDARD

TECHNICAL MANUAL. HPKM Column Shoe Reliable Bolted Column Connections. Version: PEIKKO GROUP ACI-M 01/2017 Designed according to ACI 318M-11

SHEAR PANEL COMPONENT IN THE VICINITY OF BEAM-COLUMN CONNECTIONS IN FIRE

(a) Pin-Pin P cr = (b) Fixed-Fixed P cr = (d) Fixed-Pin P cr =

European Technical Assessment. ETA-17/0237 of 15/05/2017. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

E TA TECHNICAL REPORT. Evaluation of Anchorages in Concrete concerning Resistance to Fire. TR 020 Edition May 2004

FIRE RESISTANCE ASSESSMENT OF PARTIALLY PROTECTED COMPOSITE FLOORS (FRACOF) DESIGN GUIDE

Comparison of One-way and Two-way slab behavior. One-way slabs carry load in one direction. Two-way slabs carry load in two directions.

Available online at ScienceDirect. Procedia Engineering 172 (2017 )

PORTAL FRAMES 1.0 INTRODUCTION

APPENDIX B ABC STRUCTURES DESIGN GUIDE

Design Calculations Date: 27/04/2017

In the following calculation a combination of Eurocode 2 and Eurocode 7 has been used. Design yield strength. Young modulus. Poisson coefficient.

CHAPTER 2. Design Formulae for Bending

COVER SHEET. Title: Component-Based Element of Beam Local Buckling Adjacent to Connections in Fire. Authors: Guan Quan Shan-Shan Huang Ian Burgess

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

FE Review Mechanics of Materials

SET PROJECT STRUCTURAL ANALYSIS OF A TROUGH MODULE STRUCTURE, IN OPERATION AND EMERGENCY Luca Massidda

CADS A3D MAX. How to model shear walls

Structural Behaviors of Long-Span Cable-Stayed Bridge With A-Shaped Tower Due to Three Wind Speeds

Experimental investigations on the influence of thermal elements on the structural stability of modern masonry walls

Schöck Isokorb type K-HV, K-BH, K-WO, K-WU

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

Multi storey buildings

SCI Assessed Report Armadillo Armatherm FR Thermal Break Material

Design of Composite Bridges Use of BS 5400: Part 5: 1979

Structural Performance of Long-Span Composite Truss and Beam Systems in Fire

Schöck Isokorb type KS

Design for Shear for Prestressed Concrete Beam

Lecture Retaining Wall Week 12

BEHAVIOUR OF REINFORCED CONCRETE STRUCTURES IN FIRE

Dimensionamento Estrutural de uma Ponte Canal. Structural Design of a Canal Bridge. Francisco Barbosa Alves de Moura. Introduction

LVL Portal Frame Design. Warwick Banks Technical Manager

STRUCTURAL EFFICIENCY OF COLD-FORMED STEEL PURLINS Vlad CUCU, Daniel CONSTANTIN; Dan-Ilie BULIGA

Buckling Resistance of Steel Tubular Columns Filled by High-strength Concrete

New approach to improving distortional strength of intermediate length thin-walled open section columns

Transcription:

International Journal of Advanced Structures and Geotechnical Engineering ISSN 2319-5347, Vol. 04, No. 03, July 2015 Structural Design of Pergola with Airfoil Louvers MUHAMMAD TAYYAB NAQASH Aluminium TechnologyAauxiliary Industries w.l.l. P.o box 40625, Doha, Qatar, Email: tayyab@alutecqatar.com Abstract: The here presented paper deals with the structural calculation for a Pergola consists of Airfoil Louvers and its supporting beams that are connected to the wall. The overall height of the pergola is about 5.0m, subjected to a wind load of 1.2 Kpa, calculated for a mean hourly basic wind speed of 25m/sec [1]. Therefore the pergola is checked for the prescribed wind load. Stresses and deflection checks obtained from the numerical model [2] have been carried out for louvers and the supporting beams and found SAFE according to different acceptance criterion. [3, 4]. The louvers are attached to the Aluminum plate when then is connected to a steel tube. The paper gives complete design procedure for the design of a pergola using SAP 2000 software. Keywords: Airfoil Louvers, Structural design, Aluminum, Steel, Numerical models Introduction: Figure 1: Sectional view of the louvers Materials: The materials and its properties used in the pergola are mentioned here. All structural steel shall have f y nominal yield strength of as specified below and having similar chemical composition and mechanical properties to those specified in BS 4360 [5] for the specified grade of steel. Grade 43 (BS 5950) [6, 7], Modulus of Elasticity E= 210000 MPa Allowable stresses: Strength P y = 275 Mpa (for t 16mm), Poisson Ratio µ=0.3, Shear Modulus G=E/ (2(1+ µ)), Coefficient of thermal expansion α=12x10-6 / 0 C Aluminum extrusions used 52i54 alloy to Structural Use of Aluminum BS 8118 Part 1: 1991 [8, 9] Modulus of Elasticity E= 70000 Mpa, Allowable stresses: Bending P o = 160 Mpa, Axial P a = 175 Mpa, Shear P v =95 Mpa, Density of Aluminum (KN/m 3 ) γ =27, Coefficient of thermal expansion α = 23x10-6 Figure 2: Composite section of the main beam IJASGE 040301 Copyright 2015 BASHA RESEARCH CENTRE. All rights reserved

MUHAMMAD TAYYAB NAQASH The louvers are connected to the Aluminum plate. The adopted Aluminum plate is not enough to satisfy the limit states; therefore it is reinforced with a steel tube (200 x 100 x 6) and therefore a composite section is adopted in the SAP 2000 numerical model. In order to avoid any galvanic reaction between the two materials, 3mm EPDM sheet is provided. The section adopted in the numerical model is not taken into account the existence of the EPDM sheet and is shown in Fig 3. C/S Airfoil blades are extruded in grade 6063- T6 Aluminium alloy as shown in Fig 4. Figure 3: Louver profiles This tube is considered only to produce the dead load of the louver and to apply linear load on the louver so to create SAP 2000 model. The properties shown in Fig 5 are for vertical Tube but as it is rotated at 45 0 in the numerical model, therefore will represent the geometric properties of the Louver which are installed inclined. Figure 4: Adopted equivalent tube for louver Design Criteria: Ultimate Limit State: Aluminum 160 MPa [8, 9] Steel 275 MPa Serviceability Limit State: Aluminum deflection = Span/175, and Steel deflection = span/200. Loading Considered for the Design Purpose: Louvers, Aluminum plate, steel tube, the deal load is calculated by the software (SAP 2000) [2]. The wind load of 1.2 KN/m 2 as per British Standards [1, 10, 11] is calculated. The calculated wind load was quite less than the one adopted for the design, furthermore, needless to mention that wind can blows through the louver, so quite low wind can be consider for the design of the louvers. Thermal loadings The thermal loading is an indirect loading and in Qatar for such long spans are considerable, therefore, they are assumed as described here. Assume temperature variation = ± 35 C. Maximum Length of Aluminum plate equals 4,000mm (as three plates are provided for all the length). Coefficient of thermal expansion (α) of Aluminum material is 23x10-6. Δ L = α x Δ L x L = 23x10-6 x35x4000 = 3.2 mm. In the case of Aluminum, the expansion is more critical than that of steel material, therefore gap (minimum 5mm) are provided to accommodate thermal expansion and contraction, and hence temperature load is not accounted for in the analysis. In the case, if gap will not be provided, stresses due to temperature need to be verified prior to the installation. When designing Aluminum structures to British Standards, the relevant load factors are specified in BS 8118: Part 1: Clause 3.2.3 Factored loading [8], [9]. According to Clause 3.2.3 the overall load factor γ f is calculated as follows: f f 1 f 2 Where γ f1 and γ f2 are partial load factors and their values can be found in Tables 3.1 and 3.2 of BS 8118. For standard design situations with the imposed load or wind action giving the most severe loading action on the structure or component. Overall load factors according to BS 8118: Loads Serviceability Limit State Ultimate Limit State Dead Load 1.0 1.2 Imposed Load 1.0 1.33 Wind Load 1.0 1.2 In contrast to BS 8118, the load factors for designing Aluminum structures are given in the Eurocode 0, BS EN 1990 [12, 13] and its National Annex. Further it is seen that design loads generated with the procedure of Eurocode 0 generates higher values for the design actions for the ULSs [14]. The design load combinations in the present case are the various combinations of the load cases for which the model needs to be checked. Since, curtain walls consist of Aluminum material therefore, according to the BS 8118 code, they are assumed subjected to dead load (DL), and Wind load (WL), and the following load combinations may need to be considered. 1.2 DL 1.2 DL ± 1.2 WL

Structural Design of Pergola with Airfoil Louvers Nevertheless, the main beams and connections are checked for load combinations with load factor 1.4. Modeling of the Pergola: The numerical model of SAP 2000 is shown here, where the longitudinal members are pinned connected to the main reinforced Aluminum tubes. Figure 5: Frame of the SAP 2000 Numerical model Maximum Induced Stress in steel tube under ULS with 1.2 is 131.8 Mpa, Therefore, Maximum Induced Stress in steel tube under ULS with 1.4 will be 131.8 Mpa x 1.4/1.2 = 153.7 < The allowable bending stress = 275Mpa for steel and 160Mpa for Aluminum. Figure 6: Wind loading on louvers (1.2 Kpa) Stresses in the main members are checked here. Maximum Induced Stress in Louvers under ULS is 20.1 Mpa < The allowable bending stress 160Mpa for Aluminum. Figure 7: Stress diagram under ULS Figure 8: Deflection due to SLS (scaled to 10 for clear visibility)

MUHAMMAD TAYYAB NAQASH Maximum deflection in Louvers =0.47 mm Limiting value = Span/175 = 2300/175 = 13.1 mm. 0.47mm < 13.1mm, Hence SAFE. Maximum deflection in steel tube =48.1 mm, Limiting value = Span/200 = 10500/200 = 52.5 mm 48.1mm < 52.2mm, Hence SAFE Verification of the Main Steel Tube: Maximum demand to capacity under ULS with 1.2 factor is 0.479, therefore the demand to capacity under ULS with 1.4 factor will be 0.479 x 1.4/1.2 = 0.56 < 1.0, Hence Safe For the adopted span (2300mm), AF-200 blade can resist a wind load of more than 2.0kpa. Hence SAFE Enough. Design of Connections: Maximum induced reaction in shear is F r = 8.2 KN. For connection design the forces need to be factored by 1.4. Since, the total shear force at the support is 8.2 KN; therefore the connection is checked for the shear force of 8.2 KN x 1.4/1.2 = 9.6 KN. [15]. A sleeve of composed of 8mm thick 2 plates and 2 # of M12 SS bolts are adopted for the connection, The shear capacity of a bolt, P sb, should be taken as: P sb = p sb A where: p sb is the shear strength of bolt A s is the shear area, usually taken as the tensile stress area, unless it can be guaranteed that the threaded portion will be excluded from the shear plane, in which case it can be taken as the unthreaded shank area. The tension capacity P nom is given by P nom = 0.8 p tb A t where: p tb = 0.7 U sb (U is the tensile strength)

Structural Design of Pergola with Airfoil Louvers Figure 9: Elevation of end details Figure 10: End details (bracket) Shear capacity of M12 SS bolt equals to 26.22 KN

MUHAMMAD TAYYAB NAQASH As the maximum induced reaction at the support is only 9.6 KN < 2x2 x 26.55 KN. (two shear planes and two bolts). Total shear applied is F v = 10 KN F v /2 (two bolts)= 10/2 (2 bolts)= 5 kn Checking plain shear Considering only two bolts (M12), and considers that e 1 is only 30mm, being S275 material used for 6mm thick tube, P v = 0.6 P y A v = 0.6 (275) (0.9x 2x 30) 6= 53.4 KN > 5 KN -----OK Block shear check P r = 0.6 p y t c (L v + K e (L t -k D )), therefore, P r = 0.6 x 275 x 6 x (30) = 29.7 KN > 5 kn ----- OK Bearing check P bs = k bs d t c p bs, therefore P bs = 1x 12 x 6 x 460 = 33.12 KN > 5 kn -----OK Using M12 bolts are safe Total shear applied is F v = 10 KN F v /2 (two bolts)= 10/2 (2 bolts)= 5 kn Checking plain shear Considering only two bolts (M12) on one side, and consider that e 1 is only 30mm, being S275 material used for 6mm thick plate, P v = 0.6 P y A v = 0.6 (275) (0.9x 2x 30) 5= 44.5 KN > 5 KN -----OK Block shear check P r = 0.6 p y t c (L v + K e (L t -k D )), therefore, P r = 0.6 x 275 x 5 x (30) = 24.75 KN > 5 kn ----- OK Bearing check P bs = k bs d t c p bs, therefore P bs = 1x 12 x 5 x 460 = 27.6 KN > 5 kn -----OK Using M12 bolts are safe Maximum shear is only 9.2KN, which is transferred to the bracket through the use of two M12 bolts, Consider the centroid of the bolts to be 75mm from the base of the 8mm thick plate, therefore induced bending moment will be 9.2 x 0.075 = 0.69 KNm resisted by two plates, provided plates are 8mm thick. Countersunk M10 stainless self-drilling screws are provided for connecting Aluminum plate to steel tube. These screws are assumed subjected to shear forces and therefore and transferring the forces to the main steel tube. The shear capacity of SS M10 screw is 18.04KN Stainless Steel Bolts (Shear Strength in KN) Diameter Class 50 Class 70 Class 80 M 10 8.41 18.04 22.27 Figure 11: Other end details Since 10Kn is the total shear acting, therefore the adopted M10 SS screws at 500mm C/C are safe in transferring the shear forces from the Aluminum plate to the Main Steel tube. Since, the main tube is quite long, therefore a sleeve connection at 6m is proposed. Lever arm equals (500-60-60-134/2) = 313mm, Therefore, net shear from the moment on the bolts

Structural Design of Pergola with Airfoil Louvers equals 21.4/0.313 = 68.7 KN, Induced shear equals 1.1 KN, Total shear = 68.7 + 1.1 = 69.5 KN. Factored shear = 69.5 x 1.4/1.2 = 81 KN Using 4 M12 SS through bolts on one side, the shear capacity of one bolt with a single shear plan as calculated in the previous section equals 26.22 KN Therefore, the shear capacity of 4 bolts with 2 shear planes = 4x2x26.22 = 209.76 KN > 81 KN ---- Hence Safe. Figure 12: Elevation of sleeve connection The sleeve is located at the center of the steel tube, so the shear is almost negligible (it is only 1.1KN), even though at it is combined with the shear induced from the bending moment. The sleeve is of the same size as that of the steel tube in thickness, in the present case the adopted bolts govern the design. The lever arm between the bolts is the governing factor for the length of a sleeve when subjected to bending moment. The total length of the sleeve is 500mm. It is not subjected to buckling as there is no axial compression moreover; Figure 13: Section of sleeve connection there are no such verifications to check the deflection of a sleeve tube. The sleeve is provided only for the continuation of the main steel tube. Conclusions: The adopted Aluminum Airfoil louvers meets the acceptance criteria both for ULS and SLS 3mm EPDM sheet in between Aluminum plate and steel tube for avoiding any galvanic reaction Reinforce the main 8mm thick Aluminum plate connecting the louvers with a MS tube 200 x 100 x

MUHAMMAD TAYYAB NAQASH 6 which then satisfy the acceptance criteria both for ULS and SLS Use stainless steel M12 countersunk bolts Use 8mm thick MS S275 grade, sleeve plates and sleeve tube Use M12 chemical anchors References [1] BS 6399-2, "Loading for buildings, Part 2: Code of practice for wind loads," British Standard, 1997 [2] CSI SAP V15, "Integrated Finite Element Analysis and Design of Structures Basic Analysis Reference Manual," Computers and Structures, Inc., Berkeley, CA, USA, 2002. [3] pren 13474-2, "Glass in building- Design of glass panes-part 2: Design for uniformly distributed loads," European Standard, 2000.4] pren 13474-3, "Glass in building - Determination of the strength of glass panes - Part 3: General method of calculation and determination of strength of glass by testing," European Standard, 2009. [4] BS 4360, "Specification for Weldable Structural Steel," British Standard, 1990. [5] BS 5950-1, "Structural use of steelwork in building," British Standard, 2000. [6] BS 5950-2, "Specification for materials, fabrication and erection Rolled and welded sections," British Standard, 2001. [7] BS 8188-1, "Structural use of aluminium, Part 1: Code of Practice for Design," British Standard, 1991. [8] BS 8188-2, "Structural use of aluminium, Part 2: Specification for materials, workmanship and protection," British Standard, 1991. [9] BS 6399-1, "Loading for buildings, Part 1: Code of practice for dead and imposed loads," British Standard, 1996. [10] BS 6399-3, "Loading for buildings, Part 3: Code of practice for imposed roof loads," British Standard, 1988. [11] EN-1991-1-1, "Eurocode 1, Actions on structures - Part 1-1: General actions - Densities, selfweight, imposed loads for buildings," in European Committee for Standardization, CEN, ed. 36 B- 1050, Brussels, 2004. [12] EN-1990, "Eurocode 0, Basis of structural design," in European Committee for Standardization, CEN, ed. 36 B-1050, Brussels, 2002. [13] Ulrich Muller., Introduction to Structural Aluminium Design: Whittles Publishing, 2011. [14] N. S. Trahair, et al., The Behaviour and Design of Steel Structures to EC3 4E: Taylor & Francis, 2008.