SF Cube. Exclusive Technology, Inclusive Approach. BC-6800 Auto Hematology Analyzer. Cell Analysis Technology

Similar documents
BC-6800 Auto Hematology Analyzer. Small Cube, Big Difference

BC Auto Hematology Analyzer. A CUTE 5-part

BC Auto Hematology Analyzer. A CUTE 5-part

Automated Hematology Analyzer. Differentiate with the XT-4000i

Automated Hematology System. Your Complete Choice

See Brilliant Results

BEYOND A BETTER BOX XN-V SERIES TM MULTISPECIES HEMATOLOGY ANALYZERS. Accelerate Your Multispecies Research Laboratory XN-V IS FOR ANIMAL USE ONLY

XN Series. What s in it for me? Krista Curcio, MT(ASCP), MBA Product Manager, Hematology Systems Sysmex America, Inc. All rights reserved.

Ruby. A shining example of. Put science on your side. Intended Use:

Automated Hematology Analyzer. Small Footprint. Big Difference.

Haematology. Reagents and analyzers SWISS HAEMATOLOGY S O L U T I O N

11/2/2015. Describe the technologies available on the XN-Series and the reason(s) for selection

It Should have five discrete analysis modes CBC, CBC+ DIFF, CBC + Retic, CBC+Retic+Diff & Retic only.

Features & Benefits Five-part differential on cat, dog, horse, cow, alpaca and llama; three-part differential on the nine other species

Performance Evaluation of the Coulter LH 750 Hematology Analyzer

Greater Possibilities By Design

norma Hematology family norma norma Vision Reagents

Department of Pathology

Quintus 5-part hematology analyzer In-depth, quality-controlled 26-parameter results

Quality Control: Tips, Troubleshooting, and Tidbits

We Believe the Possibilities. Automated hematology Analyzer. XN-L Series. Leading Hematology for Better Patient Care

Reshaping compact automation

Reshaping compact automation

XN-SERIES AUTOMATED HEMATOLOGY SYSTEMS

norma Hematology family norma Access norma norma Vision Reagents

9/29/2015. Describe the technologies available on the XN-Series and the reason(s) for selection

XN Hematology Case Studies Every Picture Tells a Story

ABX Pentra DX120. Hematology analyzer. 45 parameters Integrated slide-maker Expert validation system

BEYOND A BETTER BOX XN-SERIES TM AUTOMATED HEMATOLOGY SYSTEMS. Reshaping Compact Automation

XN-9100 AUTOMATED HEMATOLOGY SYSTEMS

Product Fact Sheet Added values XN-CBC and XN-DIFF

BEYOND A BETTER BOX XN-9000 AUTOMATED HEMATOLOGY SYSTEMS. Reshaping Scalable Automation

Immature Granulocyte Enumeration Our Journey from Manual to Automated Reporting

CONCURRENT 10: THE COMPLETE BLOOD COUNT AND BEYOND: QUALITY ISSUES AND REFERENCE METHODS

Verification of abnormal results from Coulter instrumentation

DxH part differential closed tube hematology analyzer

Diagnostic Medical Equipment New Revenue for Your Medical Practice

RUO Addendum. UniCel DxH Series with System Manager Software. Coulter Cellular Analysis System. B26673AC July 2015

Note: Please complete the report and submit it to SMILE and your PNL within 30 days. Site/Laboratory Name: New York EQA Provider and #: CAP

Pushing limits in routine laboratory haematology with the XT-4000i

Evaluation of the Automated Immature Granulocyte Count (IG) on Sysmex XE-2100 Automated Haematology Analyser vs. Visual Microscopy (NCCLS H20-A)

Dry Hematology Analyzer Fast, Simple CBC Analysis Designed for the Point of Care

HST-330 TM and Total Laboratory Automation

Simply stated, hematology analyzers determine the

AUTOMATED HEMATOLOGY IN THE CLINICAL LAB

WADA Technical Document TD2019BAR. Blood Analytical Requirements for the Athlete Biological Passport

BEYOND A BETTER BOX DI-60 INTEGRATED SLIDE PROCESSING SYSTEM. Seamless Integration

Diagnostics solutions. hematology reagents and Analyzers

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Iron Deficiency Anemia

The Simple Solution for CBC Testing

UNRIVALED SIMPLICITY. Exceptional Ease of Use. The STAR brings new meaning to the word simple

ABX Pentra XL 80. Hematology analyzer. Auto-sampling 5-part Differential Customized Dilution Ratio Integrated Validation Station

Medonic M-series M32. User s Manual

Evaluation of the Sysmex XN-550, a Novel Compact Haematology analyser from the XN-L series, compared to the XN-20 system.

HEMATOLOGY ANALYZERS NOVEMBER 2018 CAP TODAY 67

New Frontiers in the UK Hematology and Flow Cytometry Market: Business Challenges, Emerging Technologies, Competitive Landscape.

A Division of Woodley Equipment Company Ltd

Reduction of the Platelet Review Rate Using the Two-Dimensional Platelet Method

New Frontiers in the US Hematology and Flow Cytometry Market: Business Challenges, Emerging Technologies, Competitive Landscape.

The Advanced integrated veterinary blood diagnostics

19F MRI cellular tracer preserves the differentiation potential of hematopoietic stem cells. Brooke Helfer, PhD Celsense, Inc Pittsburgh PA

Hematology and Coagulation Controls

Upon completion of the Clinical Hematology rotation, the MLS student will be able to:

MAXIMAL PRP BANK. Utility Model Patent Registered Apply for PCT.

TENDER DOCUMENT. NIT No.: NRO/CON/738/672 Date: FOR VOLUME III BILL OF QUANTITY / PRICE BID ENGINEERING PROJECTS (INDIA) LIMITED

ICSH guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting

Test Name Results Units Bio. Ref. Interval. Packed Cell Volume (PCV) %

Supporting Information. For

XS-1000i New Sysmex 5-part diff haematology analyser with fluorescence technology

VetScan HM5 Hematology System

The Story of the Platelet Clump. Wayne Hall MTN Network Laboratory Magee-Womens Research Institute Pittsburgh, PA

Hematopoietic Progenitor Cell Product Characterization

XN Series. Greater Possibilities by Design What s in it for me? Krista Curcio, MT(ASCP), MBA Product Manager, Hematology Systems

Capital Authorization Request Lake Fork Health Service District

CellaVision DM96. Automated Digital Cell Morphology

Original Article. A Novel Automated Slide-Based Technology for Visualization, Counting, and Characterization of the Formed Elements of Blood

Feature. Hematology Analyzer: From Workhorse to Thoroughbred. Ellen Sullivan

(A-B) P2ry14 expression was assessed by (A) genotyping (upper arrow: WT; lower

Hematology analyzers. Test menu: Chartable (standard menu: WBC, RBC, Hb, Hct, MCV, MCH, MCHC, PLT, %&# neut, mono, lymph, eos, baso):

Examples of body fluid analysis with the XE-5000

SCBM343- Complete Blood Count

(12) Patent Application Publication (10) Pub. No.: US 2015/ A1

CLINICAL SIGNIFICANCE

OFFICE OF THE DIRECTOR (MEDICAL SERVICES) NEW DELHI MUNICIPAL COUNCIL CHARAK PALIKA HOSPITAL MOTI BAGH : NEW DELHI

The Future of Hematological Diagnosis

Auto-Validation Don t Rule It Out!

Scholars Journal of Applied Medical Sciences (SJAMS)

QUICK REFERENCE GUIDE. Easy operation fast results. Closer to Care.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Validation of Platelet Counting Accuracy With the Celltac F Automated Hematology Analyzer

SUPPLEMENTAL METHODS. Chromatin immunoprecipitation (ChIP) assay. Cell culture. Non-ablated mouse transplantation. Hematology and flow cytometry

True Walkaway Automated Urinalysis, Chemistry to Microscopy The CLINITEK AUWi System Answers for life.

Initial performance evaluation of the UniCel â DxH 800 Coulter â cellular analysis system

MGH Pathology Service Laboratory Reflex Test Protocols 2011 Approved by MGH Medical Policy Committee 07/27/2011

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Supplementary Information

2111: ALL Post-HCT. Add/ Remove/ Modify. Manual Section. Date. Description. Comprehensive Disease- Specific Manuals

Iron Status Assessment <DUE: 5/15/14>

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Transcription:

Cell Analysis Technology Exclusive Technology, Inclusive Approach BC-6800 Auto Hematology Analyzer

Cell Analysis Technology SF Cube SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Side laser scatter (cellular complexity) Fluorescence signals (DNA/RNA information) Laser source Forward laser scatter (cell size)

DIFF BASO NRBC Mon Neu+Bas Lym Eos Ghost Bas Other WBC NRBC Ghost WBC Diff analysis in BC-6800 is a flow cytometric method that uses the SF Cube cell analysis technology to achieve a higher level of accuracy in WBC differential and flagging. After treated by reagents, the differential WBC populations are located in the DIFF scattergram according to their size, cellular complexity, and DNA/RNA information. IMG*(#, %) parameters provide information about immature granulocytes, including promyelocytes, myelocytes and metamyelocytes. HFC*(#, %) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. Basophils are rendered bigger and more complex than other WBC sub-populations after mixing with reagents. The total WBC count is primary based on Baso channel with additional comparison of WBC information from 3 other delicated optical channels in order to eliminate the interference from NRBC, Lyse-resist RBC, etc. NRBCs are counted in a dedicated channel by SF Cube method, which ensures timely and accurate results and provides the clinicians with information permitting better treatment decisions. BC-6800 automatically corrects total WBC count and 5-Part Diff results when NRBCs are detected. This ensures more reliable WBC & 5-Part Diff results and decreases manual review rate and also possibility of errors. * means research parameter

Cell Analysis Technology Focusing Flow-DC method The Focusing Flow-DC method uses sheath fluid to ensure optimum environment for reliable cell counting. The primary sheath flow ensures that cells pass through the counting aperture in single file and the secondary sheath flow prevents recirculation of the counted cells. These hydrodynamically focused cells are measured by DC method using their resistance to passage of electricity between electrodes positioned across the counting aperture. Secondary sheath flow Primary sheath flow

Focusing Flow-DC method RBC & PLT RET PLT-O RBC RBC LFR MFR HFR LFR PLT-O* MFR HFR PLT-O* The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. Because of this, the histogram related parameters like MCV, RDW-CV, RDW-SD are more accurate and provide more reliable clinical information. Reticulocyte parameters provide information on status of erythropoiesis and extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. In the SF Cube cell analysis technology, reticulocytes are differentiated from the other red cells by their reaction with fluorescent stain. Besides the traditional parameters such as RET# and RET%, BC-6800 provides data concerning immature reticulocytes (MFR, HFR), which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. In the SF Cube cell analysis technology, platelets can be distinguished from the other interfering cell populations. PLT-O* result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. PLT result is automatically corrected when PLT-O* counting mode is employed. * means research parameter

Cell Analysis Technology Let BC-6800 transform Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer s output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations.

BC-6800 your lab! Both PC and touch screen operation 125 tests/hour 100 tubes capacity Built-in and external barcode scanner Supports wider sizes and types of sample tubes Easy to load information Convenient replacement of reagents CBC-Monitor On-line external quality control Run STAT sample at any time

BC-6800 Auto Hematology Analyzer Technical Specifications: Principles SF Cube cell analysis technology for WBC, 5-Part diff, NRBC, RET and PLT-O Focusing Flow-DC method for RBC and PLT Cyanide free hemoglobin measurement Sample Volume Predilute mode (capillary blood), Open vial Manual mode (whole blood), Open vial Autoloader mode (whole blood), Closed vial 40μL 150μL 200μL Parameters 33 reportable parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#; RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, RET%, RET#, IRF, LFR, MFR, HFR, NRBC#, NRBC%; PLT, MPV, PDW, PCT, P-LCR, P-LCC 14 research parameters: HFC#, HFC%, IMG#, IMG%, WBC-R, WBC-D, WBC-B, WBC-N, RBC-O, PLT-O, PLT-I, PDW-SD, InR#, InR 2 histograms for RBC and PLT 3 scattergrams (3D) for DIFF, NRBC and RET 6 scattergrams (2D) for DIFF, BASO, NRBC, RET, RET-EXT, PLT-O Performance Parameter Linearity Range Precision Carryover WBC 0-500 10⁹/L 2.5% ( 4 10⁹/L) 1.0% RBC 0-8 10¹²/L 1.5% ( 3.5 10¹²/L) 1.0% HGB 0-250g/L 1.0% (110-180g/L) 1.0% HCT 0-75% 1.5% (30%-50%) 1.0% PLT 0-5000 10⁹/L 4.0% ( 100 10⁹/L) 1.0% RET# 0-0.8 10¹²/L 15% (RBC 3 10¹²/L; / 1% RET% 4%) 680mm Throughput Up to 125 samples per hour (CBC+DIFF) Up to 90 samples per hour (CBC+DIFF+RET) Loading capacity Up to 100 sample tubes Mode CBC, CBC+DIFF, CBC+RET, CBC+NRBC, CBC+DIFF+RET, CBC+DIFF+NRBC, CBC+DIFF+RET+NRBC, RET Data storage capacity Up to 100,000 patient results including all numeric and graphical information Printout Various printout formats and user-defined formats available Operating environment Temperature: 15ºC~32ºC Humidity: 30%~85% 700mm Weight (kg) 125 850mm DISTRIBUTOR: 2010-2011 P/N:ENG-BC6800-210285x8-20111010 Mindray is listed on the NYSE under the symbol MR Mindray Building, Keji 12th Road South, High-tech Industrial Park, Nanshan, Shenzhen 518057, P.R. China Tel: +86 755 8188 8998 Fax: +86 755 26582680 E-mail: intl-market@mindray.com Website: www.mindray.com