DIVISION 8 DOORS AND WINDOWS

Similar documents
HOTEL SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

Division 08 OPENINGS TABLE OF CONTENTS

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

DETAILED METAL DOOR SPECIFICATION. UNIVERSITY CONTACT: Mark Golden, Supervisor of Structural Services (302)

2. Typical door size shall be 3-0 x 7-0. Wider doors should be used if required by function.

INDEX. General Information Overview Full Flush Doors Stile and Rail Doors. Full Flush Door Constructions L Series

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

SECTION DOOR HARDWARE

SECTION METAL DOORS & FRAMES

SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION METAL DOORS & FRAMES

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY

1. Section Steel Doors and Frames. 2. Section Flush Wood Doors 3. Section Aluminum Storefront Doors.

SECTION ALUMINUM-FRAMED STOREFRONTS

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

Addendum No. 1 DELETE; TABLE OF CONTENTS "SHELVING & CLOSET HARDWARE" REVISION; DOOR HARDWARE - see attached revised Specifications.

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

DIVISION 8 DOORS AND WINDOWS

Hardware 1. GENERAL 2. PRODUCTS. Page -1-

Section METAL FRAMES

Hollow Metal Doors and Frames

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

1. Section Steel Doors and Frames. 2. Section Flush Wood Doors. 3. Section Overhead Coiling Doors.

FLUSHLINE ENTRANCES. Features

CITY OF FORT COLLINS BUILDING STANDARDS SPECIFICATIONS/DIV 8

SECTION DOOR HARDWARE

Division 08 - Openings

DIVISION 8 DOORS & WINDOWS

16 Passaic Avenue, Unit 9 Fairfield, NJ Phone: (973) Fax: (973)

A. Work of this Section, as shown or specified, shall be in accordance with the Contract Documents.

Aluminum-Framed Entrances and Storefronts

SECTION ACCESS DOORS AND FRAMES

1. Include construction details, materials, individual components and profiles, and finishes.

A. Access doors and frames are part of an access door and frame allowance.

SECTION HARDWARE

SECTION ACCESS PANELS

1 3 4 Tie Rod Aluminum Swing Entrance Doors

BID # College Center EXTERIOR DOOR REPLACEMENT SECTION "C" TECHNICAL SPECIFICATIONS OWNER

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

A NEW SCHOOL ATHENS BIBLE SCHOOL FOR THE PRESIDENT AND BOARD OF DIRECTORS ATHENS, ALABAMA

Door Hardware

SECTION ALUMINUM WINDOWS

Specification Section Storefront Systems has been revised. Omit previously issued Storefront section.

Colorado Mountain College Dillon Campus ADA Entry Vestibule

SECTION HOLLOW METAL DOORS AND FRAMES. A. Section includes steel doors and frames (hollow metal) indicated and as specified.

SECTION DOOR HARDWARE. B. Related Sections: 1. Section STEEL DOORS AND FRAMES

Wind Rated / FloRida approved

Section A2 Table of Contents ALL GLASS ENTRANCES

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

UNIVERSITY OF MISSOURI Division 08 Openings (Doors, Windows, & Glass)

DOOR HARDWARE

Division 08 Openings Section Ohio Utilities Protection Service New Office Building Bid Package B METAL DOORS AND FRAMES

B. Related Sections: The following Sections contain requirements that relate to this Section:

PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

Product Description. Standard Sizes and Hardware Locations

2. Input from Building Envelope Professional required at early stage in design development if proposed design impacts exterior envelope of building.

INDEX General Information Flush Frames Drywall Frames Technical Data Sheets Anchors

Spec. Standard: 07/25/ Revision: 01/31/14

L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System

Sample Specification Prepared By: Combs & Associates, Inc. Manufacturers Representatives

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

SECTION DOOR HARDWARE Specifier Note: Items in RED are choices depending on specific project needs

SERIES H-HF-CH DOORS HONEYCOMB DOOR- (LOCKSEAM-SEAMLESS-SEAMWELDED)

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947

Aluminum Storefront Systems SERIES 200, 300 and 500 DOORS GUIDE SPECIFICATIONS

SECTION ACCORDION FOLDING PARTITIONS

COMPLETE REVISION November Process Industry Practices Architectural. PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

SECTION DETAILS (MECHANICALLY ASSEMBLY)

St. Monica Food Pantry Hollow Metal Doors and Frames SBA-13105

Hardware. A. PRODUCT DATA: Submit manufacturer's technical information for each item of hardware.

/ TECHNICAL DATA DOORS

PIP ARS08710 Standard Steel Door Hardware Supplier Specification

SECTION STEEL DOORS AND FRAMES

ADDENDUM # 1 To: RFP for: Blanco Store Fronts, Lighting & Mechanical Improvements

UC DAVIS Campus Design Guide DIVISION 08 OPENINGS

SECTION STEEL DOORS AND FRAMES

The motor shall be high-starting torque, ball bearing, rated at 460 V, 3 phase

First Draft w/editorially removed text eliminated - 6/18/2012

Woolf Distributing. Commercial Door Division. Commercial Steel Doors & Frames. Commercial Wood Doors

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

1. Bullet resistant hollow metal door and frame assemblies tested in accordance with UL 7 52 and in compliance with the following:

ELLISON BRONZE SECTION EXTRUDED ALUMINUM BALANCED DOOR ENTRANCES

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1

GENERAL SERVICES DEPARTMENT

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames.

SECTION TOILET PARTITIONS. A. Section Structural Steel: Supports for ceiling hung compartments.

Bullet Resistant Doors P/N BRD_

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1

LTH3700, HOLLOW METAL SLIDING FIRE DOOR

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION ACCESS DOORS AND FRAMES

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

Lykes Steamship Building 1770 Tchoupitoulas St. New Orleans, LA

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

DOOR HARDWARE GROUPS AND FINISHES

1-3/4 Whisper Core Door Systems

Transcription:

SECTION 08001 DOORS, WINDOWS, AND GLAZING DOORS, WINDOWS, AND GLAZING DIVISION 8 DOORS AND WINDOWS 08001-01 HOLLOW METAL DOORS AND FRAMES 01.1 Acceptable Manufacturers: Subject to compliance with the following specifications provide hollow metal from only one of the following: A. Ceco Door Products B. Steelcraft Manufacturing Co. C. (C) Curries Co. 01.2 Material Insulated Exterior Doors: Face sheets are to be made of commercial quality 16 gage hot dipped zinc coated steel that complies with ASTM A525 A60. Vertical edges shall join the face sheets by a continuous weld extending the full height of the door. Welds are to be ground, filled and dressed smooth to make them invisible and provide a smooth flush surface. Hinge reinforcements shall be not less than 7 gage (3/16) plate 1-1/4" x 9" height to receive heavy weight (.180) hinges. Reinforce tops and bottoms of all doors with a continuous steel channel not less than 16 gage, extending the full width of the door and welded to the face sheet. Doors with an inverted top channel shall have a steel closure channel welded in place so the channel is flush with the top of the face sheets of the door. Plastic fillers are not acceptable. Door cores shall have 22 gage vertical steel stiffeners spanning the full thickness of the interior space between door faces. Stiffeners shall be spaced not more than 5" on centers. Spaces between stiffeners shall be filled with fiberglass insulation (minimum density 0.8#/cubic ft.). 01.3 Material - Interior Doors: Face sheets are to be made of commercial quality 18 gage cold rolled steel conforming to ASTM A366 or 620.Vertical edges shall be mechanically interlocked with a hairline edge seam. Hinge reinforcements shall be not less than 7 gage (3/16") plate 1-1/4" x 9" height to receive standard weight (.134) hinges. Reinforce tops and bottoms of all doors with a continuous steel channel not less than 16 gage, extending the full width of the door and welded to the face sheet. Top and bottom channels shall be flush with top and bottom of door. Door cores shall be a one-piece resin-impregnated honeycomb securely bonded to both face sheets. 01.4 Material - Exterior Frames: Shall be 14 gage hot dipped zinc coated steel that complies with ASTM A526 A60.All frames are to be assembled so that the face miter seam is "closed and tight". Weld the face seam and the full web of the frame corner or intersection. Grind and dress the weld area smooth. Apply a zinc rich primer over the grinding area, and finish with matching prime paint. Run a continuous fine bead of white silicone caulk around frame after installation. 8-1

SECTION 08001 DOORS, WINDOWS, AND GLAZING 01.5 Material - Interior Frames: Shall be 16 gage that complies with ASTM A366 or A569. All frames shall be knock- down type (KD) or drywall type (DW).Furnish cased openings frames where indicated on the Drawings. Run a continuous fine bead of white silicone caulk around frame after installation. Labeled Doors and Frames: Construct and install doors and frames to comply with current issue of National Fire Protection Association (NFPA) Standard Number 80, as herein specified. Labeled doors and frames shall be provided for those openings requiring fire protection ratings as determined and scheduled. Doors and/or frames for labeled openings shall bear either a stamped or applied label from Warnock Hersey of Underwriters Laboratory. Labeled doors and frames shall comply with procedures of labeling agencies and codes of authority having jurisdiction. 01.6 Prime Finish: Doors and frames are to be thoroughly cleaned and chemically treated to insure maximum finish paint adhesion. All surfaces of the door and frame exposed to view shall receive a factory applied coat of rust inhibiting primer. The finish shall meet the requirements for acceptance stated in ANSI A224.1 "Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces". The prime finish is not intended to be the final layer of protection from the elements. Field painting per section 09900. 08001-02 ROLL-UP DOOR 02.1 Insulated Roll-up door, furnished and installed by manufacturer. Series 625 Stormtite insulated heavy-duty rolling service door, frame only painted white, with chain hoist operation standard. Options: Weatherseal on interior side guide, lintel seal, galvanized steel bottom bar with pin-lock provided on curtain wall @ 36 AFF. Padlock and Keys provided by Wawa. Manufacturer Overhead Door Corp 952 Route 202 South Somerville, NJ08876 Contact: Jim Norman Phone: 908-722-5785 08001-03 STOREFRONT, VESTIBULE, AND WINDOWS 03.1 Manufacturer Kawneer Contact: Cheryl Wilkerson, Account Manager Kawneer CID Sales Phone: 317-771-9263 cheryl.wilkerson@alcoa.com 03.2 Storefront Framing and Glazing 8-2

SECTION 08001 DOORS, WINDOWS, AND GLAZING A. Kawneer TriFab 451 (2"x41/2") for exterior store front. Kawneer TriFab 450 (1 3/4" x 4 1/2") on interior storefront (between Store and Vestibule). Finish #17 Clear Anodized. Verify with Drawings. B. Glazing 03.3 Doors 1. Exterior Clear-1" clear insulated low-e tempered units (1/4" tempered clear glass, 1/2" air space, 1/4" clear tempered low-e on surface #3). 2. Exterior Reflective 1 reflective insulated tempered units (1/4 tempered clear glass outside, 1/2 air space, ¼ Pacifica glass w/solarcool2 on surface #3.Manufacturer: PPG. 3. Interior and Door Lites -1/4" clear tempered safety glazing. 4. Exterior Spandrel Units - 1" Lava (1/4" tempered Lava spandrel, 1/2" Styrofoam insulation, 1/4" tempered Lava spandrel).manufacturer: Oldcastle Glass. 5. Windows on sides of building 1 Insulated tempered tinted low-e glass (1/4 Solargray tempered, ½ anodized spacer, ¼ tempered clear inside.) 6. Window Tint 3M Night Vision 15 (15% LVT) on all clerestory glass. A. Remodels: Kawneer '500' Wide Stile Swing Door with CO-(Pull and CPIl Pull Handle, and 10" height bottom rails, #628 finish. Top and bottom offset pivots hinges. LCN 4041 surface mounted closers with drop plate, no hold open, ADA approved. Adams Rite MS1850 maximum security deadlock cylinder on exterior doors. Provide thumb turn lock on interior side of all Vestibule doors. Sealair Bulb Weather-stripping required. Option stores without Vestibule require 1 tempered insulated low E glazing. Threshold, Pemko Half Saddles #252A to accommodate mat. B. New Stores: Kawneer '500' Wide Stile Swing Door with CO-(Pull and CPIl Pull Handle, and 10" height bottom rails, #628 finish. Top and bottom offset pivots hinges. LCN 4041 surface mounted closers with drop plate, no hold open, ADA approved. Adams Rite MS1850 maximum security deadlock cylinder on exterior doors. Provide thumb turn lock on interior side of all Vestibule doors. Threshold ½ x 4 saddle type, ADA approved. Sealair Bulb Weather-stripping required. 03.4 All joints on interior and exterior of storefront to be caulked, color: Anodized Aluminum. END OF SECTION 8-3

08700-01 01.1 Hardware schedules are to be submitted in the format provided by the Door & Hardware Institute. 01.2 General Provide aluminum handicap accessible thresholds for all exterior doors, except exterior Cold Delivery, Meter Room and Exterior Storage (including Kawneer doors) and weather-strip the hollow metal door at the Work Room exit way when required. Add door stops at exterior Vestibule doors, only when doors open against storefront. Hardware to conform to all state and local handicap code specifications. Interior hinged door shall have a maximum opening force of five (5) pounds. Fire doors and exterior hinged doors shall have a minimum opening force allowable by fire and panic. Hardware for Kawneer or YKK doors shall be supplied by the manufacturer (offset pivots and/or center pivots). All doors required to be accessible will not require light grasping, tight pinching, or twisting of the wrist to operate. 01.3 All hardware furnished by Wawa. The intent of this specification is to be used as a guideline estimating and establishing a standard of quality. It does not relieve the Contractor from furnishing all materials that may be necessary for the satisfactory completion of the work. 01.4 Hardware numbers specified herein are taken from the catalogs of the following manufacturers: Item Manufacturer Acceptable Substitutes Hinges Hager Hinge Co. (HA) Stanley, McKinney Locks/Latches Schlage Lock Co. (SC) No Substitution Closers LCN (LC) No Substitution Thresholds National Guard (NA) No Substitution Stops/Silencers Hager Hinge Co. (HA) Ives, Rockwood, Burns Push/Pull/Kick Hager Hinge Co. (HA) Ives, Rockwood, Burns Overhead Stops Rixson (RX) Glynn Johnson Exit Devices Von Duprin (VO) No Substitution Push Button Locknetics (LO) No Substitution 01.5 Hinges shall be as specified with ball or oilite bearings. For out swinging exterior doors, furnish N.R.P. (non-removable pin) hinges. 01.6 Closers with "CUSH" type arms shall have back check set to slow the door opening cycle from 75 degrees to full open/stop position. Closers on exterior doors shall be installed with thru-bolts. 01.7 Thresholds and weather-stripping: Neatly cope threshold around frame and caulk. All exterior doors shall be furnished with weather-stripping type NGP120NA. 8-4

01.8 Keying: All locks and cylinders for each store shall be keyed alike including cylinders for aluminum entrance doors. The only exception is the lockset for the Cold Delivery Door which is to be keyed separately to Wawa's delivery key. Coordinate with Wawa's representative to determine manufacturer and key section for this lockset. 01.9 Hardware Supplier William McAuliffe III, AHC 225 West Germantown Pike Plymouth Meeting, PA19462 Phone: 610-825-3001 Email: bill@mcauliffe.comcastbiz.net 08700-02 SCHEDULE 02.1 The following schedule lists door openings by identifying their location. As there are several different store layouts, you may find all opening descriptions do not apply to the store on which you are bidding. 02.2 Aluminum Entrance & Vestibule Doors: All hardware to be supplied with the doors by the manufacturer except the lock cylinders. (See "Vestibule and Storefront Glazing")Furnish one (1) cylinders for each exterior door with keying compatible with the locks and cylinders on the balance of the job. Finish of cylinder faces shall match the finish of the aluminum doors. Provide door stops on concrete walks for doors opening against storefront glazing. 02.3 Hardware Schedule HW1 Door D Exterior Cold Delivery: 4-0 x 7-0 x 1 ¾ HMD x HMF 1 Deadlock B661P C145 Keyway KA 626 SC 1 Door Pull 7N US26D HA 1 Closer 1461 H CUSH TBSRT AL LC 1 Gasketing 120 NA 1 x 48 + 2 x 84 NA 1 Overhead Holder 8-526 630 RX 1 Saddle Threshold 410 x 48 AL NA HW2 Door EX Exterior Exit: 3-0 x 7-0 x 1 ¾ HMD x HMF 1 Exit Device 22EO SP28 VO 1 Closer 1461 CUSH TBSRT AL LC 1 Panic Threshold 804 V x 40 AL NA 1 Gasketing 120 NA 1 x 36 + 2 x 84 NA 8-5

HW3 Door W Retail Area to Backroom: 3-0 x 6-8 x 1 ¾ HMD x HMF single acting with 4 x25 safety glass vision panel. 1 Continuous Hinge 780-112 HD x 79 CLR HA 1 Push Plate 30S 8 x 16 US32D HA 1 Door Pull 33E 4 x 16 US32D HA 1 Closer 1461 H AL LC 1 Protection Plate 190S 16 x 34 US32D HA 1 Protection Plate 190S 16 x 35 US32D HA HW3.1 Door W1 Retail Area to Backroom: 3-0 x 6-8 x 1 ¾ HMD x HMF double acting with 4 x25 safety glass panel. 1 Pivot Set 7255 US26D IV 2 Push Plate 30S 8 x 16 US32D HA 1 Closer 6033 BUMP AL LC 1 Protection Plate 190S 16 x 34 US32D HA 1 Door Pull 7N US32D HA HW5 Door TE Exterior Trash Room: 4-0 x 7-0 x 1 ¾ HMD x HMF with 10 x10 safety glass vision panel. 1 Continuous Hinge 780-112HD x 83 CLR HA 1 Lockset AL80PD SAT C145 Keyway KA 626 SC 1 Closer 1461 CUSH TBSRT AL LC 1 Saddle Threshold 410 x 48 AL NA 1 Gasketing 120 NA 1 x 48 + 2 x 84 NA 1 Door Sweep 102 VA x 48 NA HW5.1 Door T3 Exterior Trash Room: 3-0 x 7-0 x 1 ¾ HMD x HMF with 4 x25 safety glass vision panel. 1 Continuous Hinge 780-112HD x 83 CLR HA 1 Lockset AL80PD SAT C145 Keyway KA 626 SC 1 Closer 1461 H CUSH TBSRT AL LC 1 Saddle Threshold 410 x 36 AL NA 1 Gasketing 120 NA 1 x 36 + 2 x 84 NA 1 Door Sweep 102 VA x 36 NA 8-6

HW6 Door T Single User (Private or Public) Toilet Room: 3-0 x 6-8 x 1 ¾ HMD x HMF 1 Continuous Hinge 780-112HD x 79 CLR HA 1 Lockset AL80S SAT C145 Keyway KA 626 SC 1 Closer 1461 REG/PA AL LC 1 Protection Plate 190S 16 x 34 US32D HA SECTION 08700 HW7 Door PT Men/Women Public Restroom: 3-0 x 6-8 x 1 ¾ HMD x HMF 2 Continuous Hinge 780-112HD x 79 CLR HA 2 Protection Plate 30S 16 x 24 B4E 630 HA 2 Door Pull 33E 4 x 16 US32D HA 2 Protection Plate 190S 16 x 34 US32D HA 2 Protection Plate 190S 16 x 35 US32D HA 2 Wall Stop 236W US32D HA 6 Door Silencer 307D Grey HA 2 Closer 4011 REG (PT) AL LC HW8 Door H Exterior Storage Room: (2) 3-0 x 7-0 x 1 ¾ HMD x HMF with Louvers & Dampers, Inc. #PLSL Security Door Louver added to one leaf only, 18H x 12W with insect screen attached. Louver shall be galvanized sheet with baked enamel finish. Color to match door. 2 Continuous Hinge 780-112 HD x 83 CLR HA 1 Door Pull 7N US26D HA 1 Deadlock B660P C145 Keyway KA 626 SC 2 Flush Bolt 282D MS 12 US26D HA 1 Panic Threshold 804 V x 76 AL NA 1 Gasketing 120 NA 1 x 72 + 2 x 84 NA 2 Overhead Holder 8-326 630 RX HW8.1 Door H1 Exterior Storage Room: (1) 3-0 x 7-0 x 1 ¾ HMD x HMF with Louvers & Dampers, Inc. #PLSL Security Door Louver. Provide 18 H x 12 W louver with #8 x 32 Phillips head steel thru bolts and insect screen. Louver shall be galvanized sheet with baked enamel finish. Color to match door. 1 Door Pull 7N US26D HA 1 Deadlock B660P C145 Keyway KA 626 SC 1 Panic Threshold 804 V x 40 AL NA 1 Gasketing 120 NA 1 x 36 + 2 x 84 NA 1 Overhead Holder 8-326 630 RX 8-7

HW9 Door CO Water Meter Closet: 3-0 x 7-0 x 1 ¾ HMD x HMF 1 Deadlock B660P C145 Keyway KA 626 SC 1 Door Pull 7N US26D HA 1 Panic Threshold 804 V x 40 AL NA 1 Gasketing 120 NA 1 x 36 + 2 x 84 NA 1 Overhead Holder 8-326 630 RX HW10 Door D1 Vendor Delivery Door: 4-0 x 7-0 x 1 ¾ HMD x HMF with 4 x25 safety glass vision panel. 1 Exit Device 22NL x 210NL 22 ALK-S1xPS9 SP28 VO 1 Electric Strike 611124VDC FSE US32D VO 1 Closer 1461 H CUSH TBSRT AL LC 1 Protection Plate 190S 36 x 46 US32D HA 1 Gasketing 120 NA 1 x 48 + 2 x 84 NA 1 Saddle Threshold 410 x 48 AL NA 1 Door Sweep 102 VA x 48 NA 1 Mortise Cylinder 20-001 x 1 ¼ C145 Keyway KA 626 SC 1 Rim Cylinder 20-022 C145 Keyway KA 626 SC HW11 Door TI Interior Trash Room: 3-0 x 6-8 x 1 ¾ HMD x HMF Labeled Fire Door with 4 x25 safety glass vision panel. 1 Continuous Hinge 780-112 HD x 79 CLR HA 1 Passage Set AL10S SAT 626 SC 1 Deadbolt B680 626 SC 1 Closer 1461 REG DEL AL LC 1 Protection Plate 190S 16 x 34 US32D HA 1 Protection Plate 190S 16 x 35 US32D HA 1 Gasketing 120 NA 1 x 36 + 2 x 80 NA 1 Saddle Threshold 410 x 36 AL NA HW12 Door OF Manager s Office: 3-0 x 6-8 x 1 ¾ HMD x HMF with 4 x25 safety one-way glass vision panel. 1 Combination Lock LR1021-S-26D-41 626 SI 1 Combination Lock LL1021-S-26D-41 626 SI 1 Cylinder Core 23-030 C145 Keyway KA 626 SC 1 Floor Stop 241F US26D HA 1 Cut Control Key 48-003 SC 1 Protection Plate 190S 16 x 34 US32D HA 1 Protection Plate 190S 16 x 35 US32D HA 8-8

HW13 Door EL Electrical Room: 3-0 x 6-8 x 1 ¾ HMD x HMF with 24 x24 louver and 4 x25 safety glass vision panel. 1 Exit Device 22L x 230L (EL) SP28 VO 1 Closer 1461 REG/PA AL LC 1 Mortise Cylinder 20-001 x 1 ¼ C145 Keyway KA 626 SC HW13.1 Door EL-1 Electrical Room Rear (Front/Back): 3-0 x 6-8 x 1 ¾ HMD x HMF with 24 x24 louver 1 Lockset AL80PD SAT C145 Keyway KA 626 SC HW14 Door C3 Closet: 3-0 x 6-8 x 1 ¾ HMD x HMF 1 Continuous Hinge 780-112 HD x 79 CLR HA 1 Lockset AL53PD SAT C145 Keyway KA 626 SC 1 Protection Plate 190S 16 x 34 US32D HA 1 Overhead Holder 8-326 630 RX HW14.1 Door C2 Closet: 2-0 x 6-8 x 1 ¾ HMD x HMF 1 Passage Set AL10S SAT 626 SC 1 Roller Bumper 272W US26D HA HW14.2 Door C1 Closet: 2-0 x 6-8 x 1 ¾ HMD x HMF 1 Lockset AL80PD SAT C145 Keyway KA 626 SC 1 Protection Plate 190S 16 x 22 US32D HA 8-9

HW14.3 Door C4 : 2-6 x 6-8 x 1 ¾ HMD x HMF 1 Passage Set AL10S SAT 626 SC HW14.4 Door C5 : (2) 3-0 x 6-8 x 1 ¾ HMD x HMF 6 Hinge BB1279 4 ½ x 4 ½ 600 HA 2 Door Pull 15P 630 HA 2 Magnetic Catches 327 IV 2 Wall Stop 236W 630 HA HW15 Door S Interior Stair: 3-0 x 6-8 x 1 ¾ HMD x HMF Labeled Fire Door 1 Fire Exit Device 22L-F x 230L-BE 06 SP28 VO 1 Closer 1461 REG/PA AL LC HW16 Door S1 Exterior Storage Room: 4-0 x 7-0 x 1 ¾ HMD x HMF with Louvers & Dampers, Inc. #PLSL Security Door Louver. Provide 18 H x 12 W louver with #8 x 32 Phillips head steel thru bolts and insect screen. Louver shall be galvanized sheet with baked enamel finish. Color to match door. 1 Door Pull 7N US26D HA 1 Deadlock B660P C145 Keyway KA 626 SC 1 Panic Threshold 804 V x 52 AL NA 1 Gasketing 120 NA 1 x 48 + 2 x 84 NA 1 Overhead Holder 8-526 630 RX HW17 Door TC Trash Compound: 3-6 x 7-0 x 1 ¾ HMD x HMF with 4 Head 1 Overhead Holder 8-426 630 RX 1 Cylinder Core 23-030 C145 Keyway KA 626 SC 1 Combination Lock LR1021-S-26D-41 626 SI 1 Combination Lock LL1021-S-26D-41 626 SI 8-10

HW17.1 Door TC2 Trash Compound: (2) 3-0 x 7-0 x 1 ¾ HMD x HMF with 4 Head x Overlapping Steel Astragal. 2 Continuous Hinge 780-112 HD x 83 CLR HA 2 Flushbolt 282D MS 12 US26D HA 1 Dust Proof Strike 280X US26D HA 1 Combination Lock LR1021-S-26D-41 626 SI 1 Combination Lock LL1021-S-26D-41 626 SI 1 Cylinder Core 23-030 C145 Keyway KA 626 SC 2 Overhead Holder 8-326 630 RX HW18 Door J Closet: 2-6 x 6-8 x 1 ¾ HMD x HMF 1 Continuous Hinge 780-112 HD x 79 CLR HA 1 Lockset AL53PD SAT C145 Keyway KA 626 SC 1 Overhead Holder 8-226 630 RX 02.4 Ceiling Access Panel: Babcock Davis #B-IT, 22" x 30" fire rated access door. Prime- painted steel with 2" mineral fiber insulation, automatic panel closer, self-latching, rating 1½ hr. Alternates- Larsen. Style L-FRAP, 22" x 30", or Karp, Style KPR-150 FR, 22 x 30. Provide Fire Rated access door in draftstopping as noted on Drawings. 02.5 Sizes: Verify all sizes of doors with Drawings. Report any discrepancies to Wawa's Project Manager. END OF SECTION END OF DIVISION 8-11