Assessment of Climate Change Robustness of a Deep Energy Retrofit Design of an Existing Day Care Centre

Similar documents
The effect of weather datasets on building energy simulation outputs

ScienceDirect. Simulation based mixed mode building design

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

Ventilation strategies for the deep energy retrofit of a kindergarten

Verified net Zero Energy Building with air source heat pumps for SME

Ventilation strategies for the deep energy retrofit of a kindergarten

Strategies for energy efficiency improvement in residential and office buildings: their role at building and country scale

The Impact of Window Operation Assumptions on the Thermal Simulation Results of an Office Building

Ventilative Cooling potential tool

Case study of an ECBC Compliant, Energy Efficient Building: Aranya Bhawan, Jaipur

Zero Energy House in Japan: Actual results and future target. Isamu Ohta Misawa Homes Institute of Research & Development CO., LTD.

A Case Study of Energy Demand in Housing Units

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Sustainable Building Façade and Advanced Fenestration Systems

Future tree planting on the two acre lot will offset remaining lifetime carbon emissions.

Next Generation District Heating

Giuseppe Giordano Founder & CEO

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

The energy benefits of View Dynamic Glass

ECO-RETROFITTING VERY OLD DWELLINGS: CURRENT AND FUTURE ENERGY AND CARBON PERFORMANCE FOR TWO UK CITIES

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

ECBC Impacts: Experiences from the ECBC Pilot Building in Rajasthan Jyotirmay Mathur Malaviya National Institute of Technology Jaipur, India

SOPHARMA AND LITEX TOWERS Hi-tech intelligent building where light, architecture and sustainability meet business

Using Prometheus weather files. Andrew Cripps Sustainable Development Group AECOM

Simulation based façade control implemented as a responsive building element

Zero Energy Building Example in Estonia. Tõnu Mauring

Design Charrette. New York State Energy Research and Development Authority 17 Columbia Circle Albany, NY NYSERDA

Building energy simulation in practice Seminar of the CIBSE Building Simulation Group 30th September 2009

BREEAM INTERNATIONAL NEW CONSTRUCTION PRODUCT DATA FOR CERTIFICATION URBANSCAPE GREEN ROOF SYSTEMS

Intelligent tall building envelope technologies and design alternatives for comfort and energy efficiency in hot, arid climate

Urban Greening and the UHI: Seasonal Trade-offs in Heating and Cooling Energy Consumption in Manchester, UK

BREEAM INTERNATIONAL NEW CONSTRUCTION PRODUCT DATA FOR CERTIFICATION URBANSCAPE GREEN ROOF SYSTEMS

Solar Energy Technologies

An investigation into potential of passive solar. features to realise net zero carbon housing

Available online at ScienceDirect. Energy Procedia 48 (2014 )

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

Ventilated facade design in hot and humid climate. Ventilated facade design in hot and humid climate

THE FRENCH EMBASSY IN TOKYO

Passive systems for energy savings of buildings in tropical climate

Sample Reports. for. HAP v4.80 Example Problem

Where,h(t)the indicial response of thermal flow rate, B 0 the

Effect of Climate Change on Building Performance: the Role of Ventilative Cooling

Heat Pump Field Trials and Implications for Design

Progress of Nordic Built project_nb13339 Low temperature heating and high temperature cooling in refurbishments and new construction of buildings

Available online at ScienceDirect. Energy Procedia 78 (2015 )

NYSERDA High Performance Development Challenge Energy Monitoring Report Hudson Passive Project

Performance-Risk Methodology for the Design of High-Performance Affordable Homes

ADAPTIVE FACADE SYSTEM BASED ON PHASE CHANGE MATERIALS

Effect of passive cooling strategies on overheating in low energy residential buildings for Danish climate

Modelling Approaches to Natural and Mixed Mode Ventilation

Parametric Louver Design System Based On Direct Solar Radiation Control Performance

ECOHOUSES - 21 st Century Ideal Buildings Minimal Imported Energy Safe in Extreme Climates Low running Costs

VELUX A/S, Daylight Energy and Indoor Climate, Ådalsvej 99, 2970 Hørsholm, Denmark *Corresponding author:

27/10/15. Rod Hughes Architect Director 2030 architects ltd. Penrith

DYNAMIC ANALYSIS OF ENERGY PERFORMANCE OF DIFFERENT ROOF SYSTEMS DURING THE COOLING SEASON

LOW-ENERGY HOUSING ESTATE SUNDAYS

Building performance based on measured data

Passive Strategies and Low-Carbon Technologies: Evaluating the Energy Performance and Thermal Comfort of a Passive House Design

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

A parametric tool for the assessment of operational energy use, embodied energy and embodied material emissions in building

Validation of Methods Used in the APVI Solar Potential Tool

OPTIMIZATION OF THE REFURBISHMENT OF THE ENVELOPE THROUGHOUT ITS LIFE CYCLE

COST - EFFECTIVE DESIGN FOR AIR-CONDITIONED OFFICE SPACE : TRANSPORT CORPORATION OF INDIA LTD. ASHOK B. LALL ARCHITECTS, NEW DELHI

Deep Energy Retrofit of a HighRise MURB

How will climate change affect future potato production and water use in South Africa?

Danish national plans for Nearly Zero Energy Buildings

A New Type of Hybrid Groundwater Energy System

Understanding Industrial Energy Use through Sliding Regression Analysis

This is an Open Access document downloaded from ORCA, Cardiff University's institutional repository:

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Work Package 2: Performance of naturally ventilated buildings

Solar Thermal Optimization for District Hot Water through Energy Modeling

Chapter 9 Integration of BSA tools in building design tools 909

GAS FOR HEATING & COOLING. POLICY WORKSHOP 14 June 2016, European Parliament

Effects of projected climate change on energy supply and demand in the Pacific Northwest and Washington State

Investigation of indoor climate in a naturally ventilated building

Sample Reports. for. HAP v4.90 Example Problem

Energy Saving Public Swimming Complex In Finland

Assessing the potential of energy retrofitting and renewables in the campus of Lund University

Procedia - Social and Behavioral Sciences 216 ( 2016 )

State Of The Art Office Building & Campus For Maharashtra Energy Development Agency(MEDA) At AUNDH, PUNE

CO₂emission of FC which is the most commercialized type of household fuel cell and gas fired boiler. Therefore, energy saving effect and carbon emissi

Quantification of the surface-atmosphere exchange of energy and carbon dioxide of an extensive urban green roof by eddy covariance measurements

Electric Forward Market Report

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Clean Energy Extension

TVA Melton Hill Dam Sustainable Recreation Area

ENERGY SELF SUFFICIENCY WITH RENEWABLE SOURCES BIOMASS AND WIND IN THE REHABILITATION PROJECTOF AN OLD RURAL BUILDING COMPLEX IN SICILY (ITALY)

Simulation investigation of heating load for solid wall house retrofitted with Vacuum Insulation Panels

equest Home Energy Model ME 514 ~ HVAC Sean Rosin University of Idaho/Boise State University Spring 2016

AN INTRODUCTION TO WEATHER NORMALIZATION OF UTILITY BILLS FOR ALTERNATIVE ENERGY CONTRACTORS. John Avina, Director Abraxas Energy Consulting

Available online at ScienceDirect. Procedia Engineering 117 (2015 )

SOLCER HOUSE ENERGY POSITIVE - LOW CARBON - LOW COST

EVALUATION OF THE SOLAR INCOME FOR BRAŞOV URBAN AREA

Woking. q business confidence report

A prototype architecture for passive and plus energy building in Estonia

Work Package 2: Performance of naturally ventilated buildings

Solving Climate: The Need for Zero Carbon On-Demand Power

BREEAM INTERNATIONAL NEW CONSTRUCTION PRODUCT DATA FOR CERTIFICATION URBANSCAPE GREEN ROOF SYSTEMS

University of Michigan Eco-Driving Index (EDI) Latest data: August 2017

Transcription:

Assessment of Climate Change Robustness of a Deep Energy Retrofit Design of an Existing Day Care Centre Amin Moazami, Salvatore Carlucci, Stig Geving Faculty of Engineering Science and Technology Department of Civil and Transport Engineering, NTNU Lorenzo Pagliano, Francesco Causone end-use Efficiency Research Group (eerg) Kunnskap for en bedre verden Department of Energy, POLIMI

Outline of presentation Existing building, monitoring and modeling Energy retrofit design specification and target How to consider climate change in BPS tools Results and the impacts of climate change on the robustness of the design Q&A session Kunnskap for en bedre verden 2

Building Description Component PRE-retrofit U-value W/(m 2 K) Vertical opaque wall 1,20 Roof 1,30 Window 5,80 Kunnskap for en bedre verden 3

Temperature, C Carbon Dioxide Concentration, ppm Indoor Environmental Monitoring 35 2500 30 25 2000 20 1500 15 10 1000 5 0 500-5 Jul-14 Aug-14 Sep-14 Oct-14 Nov-14 Dec-14 Jan-15 Jan-15 Mar-15 Apr-15 May-15 May-15 Jun-15 Jul-15 Outdoor dry-bulb air temperature 0 Jul-14 Aug-14 Sep-14 Oct-14 Nov-14 Dec-14 Jan-15 Feb-15 Mar-15 Apr-15 May-15 Carbon Dioxide Concentration Ref: Moazami, Amin; Carlucci, Salvatore; Causone, Francesco; Pagliano, Lorenzo.(2016) Energy retrofit of a day care center for current and future weather scenarios. Procedia Engineering. vol. 145. Kunnskap for en bedre verden 4

Temperature, C Numerical model calibration 34 32 Mean Bias Error (MBE) (%): 30 28 26 24 22 20 Coefficient of Variation of Root Mean Square Error CV(RMSE) (%) 18 16 14 12 10 25-May 28-May 31-May 3-Jun 6-Jun 9-Jun 12-Jun 15-Jun 18-Jun 21-Jun 24-Jun 27-Jun Outside Dry-Bulb Temperature M easured I ndoor Air Temperature Simulated Indoor Air Temperature Category Goodness-of-fit index Final Simulation (%) Monthly energy use Hourly indoor air temperature ASHRAE Guideline 14 Criteria (%) MBE 3,7 5,0 CV (RMSE) 11,6 15,0 MBE 0,8 10 CV RMSE 4,2 30 Kunnskap for en bedre verden 5

Energy Retrofit Targeting nzeb Reducing the energy need for space heating. Adopting passive strategies for cooling Improving IAQ by installing highly-efficient decentralised ventilation Installing new grid-connected renewable energy generation systems. Ensuring adequate thermal comfort conditions all-year long. Reducing construction time to limit the disturbance or interruption of the educational service. Kunnskap for en bedre verden 6

Energy Retrofit Design Integrated wooden prefabricated façade High Thermal insulation of opaque and transparent surfaces Automated movable Solar shading Automated openings for automatic natural ventilation Mechanical ventilation with heat recovery Lighting controls Renewable energy generation system Component PRE-retrofit U-value, W/(m 2 K) POST-retrofit U-value, W/(m 2 K) Vertical opaque wall 1,00 0,10 Roof 0,90 0,10 Window 5,85 0,73 Kunnskap for en bedre verden 7

Preliminary results based on TMY 85% reduction of primary energy Can a TMY weather file (data from period of record 1951-1970) be representative of current and future weather conditions? Will the retrofit design of today be robust against the climate change? Ref: Causone, Francesco; Moazami, Amin; Carlucci, Salvatore; Pagliano, Lorenzo; Pietrobon, Marco. (2015) Ventilation strategies for the deep energy retrofit of a kindergarten. 36th AIVC Conference Kunnskap for en bedre verden 8

Climate Change Figure SPM.5. Solid lines are multimodel global averages of surface warming (relative to 1980 1999). Shading denotes the ±1 standard deviation range of individual model annual averages. (Ref: IPCC 2007,WG1-AR4) To adjust current weather files to reflect climate change scenarios. A morphing technique is proposed by Belcher et al. (2005) and used by Jentsch et al. (2008) in the publicly available tool CCWorldWeatherGen (2009). The calculation principles of this tool are based on the A2 emission scenario and HadCM3 coupled model. Kunnskap for en bedre verden 9

Current and future climate scenarios Post-retrofit model Conditioned mode Free-running mode (summer) TMY 2014 2020 2050 2080 TMY 2014 2020 2050 2080 Pre-retrofit calibrated model Free-running mode (summer) TMY 2014 2020 2050 2080 Kunnskap for en bedre verden 10

Primary Energy (kwh/m2) Results - Conditioned Mode 25,00 20,00 15,00 10,00 5,00 0,00-5,00-10,00-15,00-20,00 TMY 2014 2020 2050 2080 Space heating Space Cooling System Fans Lighting Electricity generated by PV Parameter (unit of measure) HDD ( C h) CDD ( C h) TMY 2014 2020 2050 2080 3002 2274 2718 2384 1988 3 45 26 116 289 Ref: Moazami, Amin; Carlucci, Salvatore; Causone, Francesco; Pagliano, Lorenzo.(2016) Energy retrofit of a day care center for current and future weather scenarios. Procedia Engineering. vol. 145. Kunnskap for en bedre verden 11

Indoor operative temperature ( C) Indoor operative temperature ( C) Indoor operative temperature ( C) Results Free-running Mode (summer) Comparison of the running mean of the outdoor temperature and the indoor operative temperature in the five weather scenarios. Ref: Moazami, Amin; Carlucci, Salvatore; Causone, Francesco; Pagliano, Lorenzo.(2016) Energy retrofit of a day care center for current and future weather scenarios. Procedia Engineering. vol. 145. 36 34 32 30 28 26 24 22 20 18 36 34 32 30 28 26 24 22 20 Tmin I Tmax I TminII TmaxI I TminIII TmaxI II Top-Post retrofit Top-Existing TMY 2050 18 5 10 15 20 25 30 35 Running mean of outdoor temperature ( C) Kunnskap for en bedre verden 12 36 34 32 30 28 26 24 22 20 18 2014 2020 2080 5 10 15 20 25 30 35 Running mean of outdoor temperature ( C)

Conclusion Designing a building for today, using only a weather file based on historical data from 1960-1990 is not desirable and even acceptable. In future weather conditions a substantial shift from heating energy needs to cooling energy needs can be expected in building operations for a climate such as Milan, Italy. A design shift from static buildings into buildings that can respond and adapt to climate change is therefore required. it should also be considered that the applicability of the available comfort models nowadays to child care centres and kindergartens presents several limitations. Kunnskap for en bedre verden 13

Thank You! Amin Moazami amin.moazami@ntnu.no +47 40476475 Kunnskap for en bedre verden 14