Sample Pre-drywall Inspection Report

Similar documents
Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

Willamette Home Inspection

component was performing its intended function; installation and condition were appropriate for age and use.

Inspection Report. Property Address:

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011

1234 Main St Denver CO 80210

Alabama Home Inspections

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012

The Inspection Process. Waxhaw N.C.

New Southern Home Inspection. Property Inspection Report

Madison's Home Inspections

All Pro Home Inspection. Home Report South Your Town

Residential Building Inspections

Home Inspection Report

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011

TML Home Inspectors, Inc.

SOUTH CAROLINA HOME INSPECTOR STANDARDS OF PRACTICE

The Inspector. Property Inspection Report

The Home Doctor, Inc.

Eagles Eye Home Inspection

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012

Inspection Report. 1 of 8

A 1 Professional Home Inspection 14 Brevoort Pl. Deer Park, NY Jamaica, NY 11434

HOME INSPECTION REPORT Prarie Circle

All Pro Home Inspection. Home Report North Your Town

Inspect Hawaii. Property Inspection Report

1234 Main St. Buyer Name. Table of Contents

1 AND 2 FAMILY DWELLING REQUIREMENTS

Property Inspection Report

FAIRA TRANSPARENCY REPORTS Glendale Dr, Blaine, WA February 27, 2018

SC Standards Of Practice for Home Inspectors

J & M Solutions, LLC

Property Inspection Report

A Summary of the Basic Duties of Maintenance, Repair and Replacement for CARRIAGE PARK CONDOMINIUM ASSOCIATION

Home Condition Checklist

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017

Friendly Inspection Services

Friendly Inspection Services

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

3D Home Improvement and Inspection Services, Inc

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

Home Inspection Report Structural Pest Inspection Report WSDA Inspection Control Number 4533AQ011

APPLICATION FOR FINISHED BASEMENT PERMIT

REPORT CHECKLIST SUPPLEMENT

Safety Money Repair Maintenance Evaluate Monitor Comment

9) Home Inspection: As defined in Section 1-10 of the Act.

TITLE 68: PROFESSIONS AND OCCUPATIONS CHAPTER VIII: DEPARTMENT OF FINANCIAL AND PROFESSIONAL REGULATION

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

Section Standards of Practice. a) The following are terms commonly used in the writing of home inspection reports.

Inspection Report. Provided by: Cummins Services LLC. Inspector: Bill Cummins. Phone:

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

GENERAL INFORMATION BUILDING INFORMATION ACRONYM RATING DEFINITIONS

Blue Goose Property Services LLC

Rental Inspection Checklist

A Sample Report On The Conditions At:

a) For the purposes of this Section, the terms listed below shall mean:

Davis Frame Co., Inc. Construction Budget Considerations

* RESIDENTIAL PLAN REVIEW *

Home Inspection Report

Summary. Cincinnati OH. This report published on Saturday, February 14, :36:40 PM EST

6954 Lakeside Dr. Property Inspection Report. - Provided by First Class Property Inspections, LLC -

Capstone Inspection Services LLC

Calidad Home Inspection Colleyville, TX (817) /

Property Condition Assessment

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

Deleted For Privacy Staten Island, NY 10308

New Jersey Home Inspection - Standards of Practice

Walnut Creek Mutual Seventy

Friendly Inspection Services

Residential Building Plans

Page 3 of 12. Inspected Describe. Explained. Health & Safety. Maj. Def. Examiner Notes STRUCTURE N/A. Financial Impact. Impact.

Summary. Inspect It Like A Girl. P.O. Box 2283 Madison, MS Customer Happy Home. Address 123 Happy Home Road Jackson MS 39157

Safety Money Repair Maintenance Evaluate Monitor Comment

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

SUMMARY 1234 Main St.Loudon TN Buyer Name 08/28/2018 9:00AM

Property Inspection Report

Home Inspection Report

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

Property Inspection Report

Atlas Property Inspections, LLC

Pre-Listing Home Inspection Checklist

SITE AND BUILDING INSPECTION CHECKLIST

Oregon Building Officials Association

Home Inspection Report

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

Accurate Home Inspection. Property Inspection Report

Property Inspection Checklist

Building Inspection Report

HomeOwner Services, Inc.

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

1st Defense Home Inspections, LLC

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits

InterNACHI Home Inspection Report Checklist

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Red Rock Home Inspections

PLYMOUTH CREEK HOME OWNERS ASSOCIATION

Transcription:

Inspector's email: inspectmorellc@gmail.com Inspector's phone: (404) 661-9763 PO Box 3755 Suwanee GA 30024-0995 Inspector: Joe Moore Client(s): Property address: Inspection date: This report published on 12:15:15 PM EDT This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited. How to Read this Report This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow Page 1 of 17

descriptive information. Concerns are shown and sorted according to these types: Safety Poses a safety hazard Repair/Replace Recommend repairing or replacing Repair/Maintain Recommend repair and/or maintenance Evaluate Comment Recommend evaluation by a specialist For your information Wood Destroying Organism Concerns Concerns relating to wood destroying organisms are shown as follows: Infestation Damage Evidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) Damage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) Conducive conditions Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp General Information Report number: 201300 Start: 9:00 am Present during inspection: Client, Realtor, Builder, Contractor Client present for discussion at end of inspection: Yes Weather conditions during inspection: Dry (no rain), Sunny Temperature during inspection: Cool Ground condition: Dry Recent weather: Sunny Overnight temperature: Cool Type of building: Single family residence Front of building faces: North Main entrance faces: North IMPORTANT NOTE: If repairs are recommended in this report, they should be performed by a qualified, licensed contractor. Repairs should be made in accordance with national and local building codes, the designer's specifications, and per the installation instructions of the manufacturer of the building materials or components. Some municipalities have requirements that exceed national requirements, such as those in areas prone to high winds, floods, snow or earthquakes. New Construction: *NOTE* (This is a preliminary pre-drywall inspection and many of the homes systems are not functional and/or the installations are incomplete. The inspector was unable to fully evaluate the property in its entirety, those items will be addressed at the time of the final inspection of the home). Foundation and Grounds Page 2 of 17

Limitations: The inspector performs a visual inspection of accessible components or systems at the foundation and crawl space. Below-grade foundation walls and footings are excluded from this inspection. Some amount of cracking is normal in foundation walls and concrete slabs due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement. The inspector does not guarantee or warrant that water will not accumulate in the crawl spaces in the future. Complete access to all crawl space areas during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so. Crawl space areas should be checked at least annually for water intrusion, plumbing leaks and pest activity. For more information, visit: http://www.reporthost.com/?foundation Rough grade: Not completed Footing material (under foundation stem wall): Poured in place concrete Foundation type: Full basement Foundation/stem wall material: Poured in place concrete Perimeter drain present: Yes Anchor bolts or hold downs for seismic reinforcement: Installed 1) One or more footings were undermined by excavation, erosion. The footing and foundation has been weakened as a result. Repairs should be made as necessary. Photo 61 Photo 91 2) General photos of the the exterior and grounds. Photo 9 Photo 10 Page 3 of 17

Photo 11 Photo 16 Floor System Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by insulation or lack of access are excluded from this inspection. The inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing. For information on floor construction, visit: http://www.reporthost.com/?frmfloor For information on under-floor insulation, visit: http://www.reporthost.com/?insfloor Pier or support post material: Bearing wall Beam material: Built-up wood, Laminated wood Floor structure above: Trusses, Engineered Brand of engineered floor joist: TJI Sub-floor sheathing: Oriented strand board (OSB) 3) One or more engineered floor joists, floor trusses, glue lams or structural composite lumber appeared to have been cut, damaged or modified. The floor structure has likely been weakened as a result. These components should only be modified by registered design professionals. Consult with the builder to determine if modifications were approved. If not then modified components should be replaced. Photo 32 Photo 37 4) One or more floors were uneven, damaged, or not level. This can result in problems Page 4 of 17

when installing other components such as cabinets, tubs, showers, trim, flooring etc. Repairs should be made as necessary. Photo 28 Photo 33 Wall System Vertical wall structure: Wood, Conventional frame Wall bracing type: Panel sheathing 5) One or more studs were split, damaged, or excessively warped. This can result in bowed or uneven walls, and problems when installing other components such as cabinets, tubs, showers, trim, etc. Repairs should be made as necessary. Photo 55 6) Wall openings at one or more locations were not square. This can result in problems when installing other components such trim and doors, etc. Repairs should be made as necessary. Page 5 of 17

Photo 71 Photo 72 Exterior Wall Coverings Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement. Wall covering: Cement fiber, Brick veneer Type of underlayment: House wrap 7) One or more sections of siding were missing. This can be a conducive condition for wood destroying organisms. Repairs should be made as necessary. Photo 63 8) Some areas of the exterior paint or stain finish were incomplete and/or substandard (e.g. primed only, too few coats). Paint or stain should be applied where necessary. Page 6 of 17

Photo 64 Decks, Porches and Exterior Stairs Deck, porch and/or balcony material: Wood Exterior stair material: Wood 9) Guardrails at one or more locations had gaps that were too large. Gaps or voids should not allow passage of a sphere equal to or greater than 4 inches in diameter, or 6 inches in diameter at triangular spaces between stair edges and guardrails. This can pose a fall hazard. Repairs should be made as necessary. Photo 17 10) Wooden deck or porch surfaces will require an application of a stain, or sealant in the future as part of normal maintenance. Recommend that a qualified person clean and preserve as necessary once the wood has seasoned. We recommend using the "cup-of-water" test before staining. Take a cup of water and pour it onto the treated lumber in several places. If the water is absorbed and doesn't bead up, the lumber is ready for painting or staining. For more information, visit; http://www.reporthost.com/?penoil http://www.reporthost.com/?dkmain Page 7 of 17

Photo 31 Roof System Limitations: Structural components such as rafters, joists and trusses, and other components such as piping, wiring and/or ducting that are obscured by insulation or lack of access are excluded from this inspection. The inspector does not determine if rafters, joists, purlins, collar ties, rafter ties, trusses, etc. are of adequate size, spanning or spacing. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. For more information, visit: http://www.reporthost.com/?frmroof Roof structure type: Trusses Ceiling structure: Trusses Roof sheathing material: Oriented strand board (OSB) Roof ventilation type: Ridge vent(s), Enclosed soffit vents 11) One or more roof trusses or engineered joists or rafters were improperly nailed. The roof decking is buckling or lifting as a result. Repairs should be made as necessary to properly secure the roof decking and allow the composition shingles to seal properly. Photo 69 Photo 70 Page 8 of 17

Photo 129 Roof Covering Limitations: Some items were not visible or readily accessible such waterproof or ice dam membranes and are excluded from this inspection. Solar heating/roofing components are also excluded. Any comments made regarding these items are made as a courtesy only. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions performed adequately or were leak-free. For more information, visit: http://www.reporthost.com/?roof Roof inspection method: Viewed from ground with binoculars Roof surface material: Asphalt or fiberglass composition shingles 12) The roof surface installation was not complete. It should be complete to prevent water damage before drywall is installed. Repairs should be made as necessary. *NOTE* (One or more 2x4s "toe boards" were nailed on top of the shingles to give the roofer support on steep pitches. Once these boards are removed the shingles will require repair to prevent water damage in the future to the decking and ceiling areas below). Page 9 of 17

Photo 65 Photo 74 Photo 5 HVAC System and Mechanical Heating system #1 type: Forced air, Furnace Heating system #1 energy source: Natural gas Heating system #1 distribution type: Ducts and registers Heating system #2 type: Forced air, Furnace Heating system #2 energy source: Natural gas Heating system #2 distribution type: Ducts and registers General cooling system type: Split system Cooling system and/or heat pump energy source: ElectricTBD Gas service type: Natural gas Gas piping material: Steel pipe 13) The furnace and/or heating systems were not fully evaluated because the installations are incomplete. Recommend that a full evaluation be made by a qualified person when conditions have been corrected so the systems are operable. Page 10 of 17

Photo 121 Photo 122 Photo 123 Plumbing Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks. Service pipe material: Plastic Interior supply pipe material: PEX plastic Fire suppression system installed: No Interior drain, waste and vent pipe material: Plastic Water heater #1 type: TankTBD 14) One or more sections of the Taexx through the wall pest control system installed in this home are cut or damaged. Repairs should be made as necessary. Page 11 of 17

Photo 62 15) General photos of the main water shut-off, water meter at the street, and roughed in gas meter/valve locations. Photo 4 Photo 14 Photo 49 Electric System Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made Page 12 of 17

regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician. Primary service type: Underground Service voltage (volts): 120-240 Estimated service amperage: 300 (150 x 2) Service entrance conductor material: Stranded aluminum System ground: Concrete encased electrode Location of main service panels: Building exterior Location of sub-panels: Garage, Basement Branch circuit wiring type: Non-metallic sheathed 16) General photos of the main disconnect and service panel. Photo 18 Photo 21 Fireplaces, Decorative Gas Appliances and Chimneys Decorative gas appliance type: Metal pre-fab fireplace Gas-fired flue type: B-vent Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector Page 13 of 17

does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist. 17) The inspector was unable to determine if the gas fireplace or stove was operable or serviceable, or perform a full evaluation as the installation was incomplete. Photo 96 Photo 97 Interiors, Windows and Doors Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances. Exterior door material: Metal, Fiberglass or vinyl Type(s) of windows: Vinyl, Single-hung 18) General photos of the interior framing of the home. Page 14 of 17

Photo 23 Photo 24 Photo 26 Photo 27 Photo 41 Photo 45 Page 15 of 17

Photo 46 Photo 47 Photo 48 Photo 51 Photo 53 Photo 94 19) Thank you for the opportunity to prepare your pre-drywall inspection report. We look forward to assisting you further with your final inspection report when your home is complete. Please contact us if you have any questions or additional concerns. Phone: 404-661-9763 Email:inspectmorellc@gmail.com Page 16 of 17

INSPECTOR INFORMATION: Joe Moore, Jr. ASHI Certified Inspector #250189 Cell # 404.661.9763 Page 17 of 17

Inspector's email: inspectmorellc@gmail.com Inspector's phone: (404) 661-9763 PO Box 3755 Suwanee GA 30024-0995 Inspector: Joe Moore Summary Client(s): Property address: Inspection date: This report published on 12:15:15 PM EDT This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited. Concerns are shown and sorted according to these types: Safety Poses a safety hazard Repair/Replace Recommend repairing or replacing Repair/Maintain Recommend repair and/or maintenance Evaluate Comment Recommend evaluation by a specialist For your information Infestation Evidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) Page 1 of 8

SUMMARY Damage Damage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) Conducive conditions Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) Page 2 of 8

SUMMARY Foundation and Grounds 1) - One or more footings were undermined by excavation, erosion. The footing and foundation has been weakened as a result. Repairs should be made as necessary. Photo 61 Photo 91 Floor System 3) - One or more engineered floor joists, floor trusses, glue lams or structural composite lumber appeared to have been cut, damaged or modified. The floor structure has likely been weakened as a result. These components should only be modified by registered design professionals. Consult with the builder to determine if modifications were approved. If not then modified components should be replaced. Photo 32 Photo 37 4) - One or more floors were uneven, damaged, or not level. This can result in problems when installing other components such as cabinets, tubs, showers, trim, flooring etc. Repairs should be made as necessary. Page 3 of 8

SUMMARY Photo 28 Photo 33 Wall System 5) - One or more studs were split, damaged, or excessively warped. This can result in bowed or uneven walls, and problems when installing other components such as cabinets, tubs, showers, trim, etc. Repairs should be made as necessary. Photo 55 6) - Wall openings at one or more locations were not square. This can result in problems when installing other components such trim and doors, etc. Repairs should be made as necessary. Photo 71 Photo 72 Page 4 of 8

SUMMARY Exterior Wall Coverings 7) - One or more sections of siding were missing. This can be a conducive condition for wood destroying organisms. Repairs should be made as necessary. Photo 63 8) - Some areas of the exterior paint or stain finish were incomplete and/or substandard (e.g. primed only, too few coats). Paint or stain should be applied where necessary. Photo 64 Decks, Porches and Exterior Stairs 9) - Guardrails at one or more locations had gaps that were too large. Gaps or voids should not allow passage of a sphere equal to or greater than 4 inches in diameter, or 6 inches in diameter at triangular spaces between stair edges and guardrails. This can pose a fall hazard. Repairs should be made as necessary. Page 5 of 8

SUMMARY Photo 17 Roof System 11) - One or more roof trusses or engineered joists or rafters were improperly nailed. The roof decking is buckling or lifting as a result. Repairs should be made as necessary to properly secure the roof decking and allow the composition shingles to seal properly. Photo 69 Photo 70 Photo 129 Roof Covering Page 6 of 8

SUMMARY 12) - The roof surface installation was not complete. It should be complete to prevent water damage before drywall is installed. Repairs should be made as necessary. *NOTE* (One or more 2x4s "toe boards" were nailed on top of the shingles to give the roofer support on steep pitches. Once these boards are removed the shingles will require repair to prevent water damage in the future to the decking and ceiling areas below). Photo 65 Photo 74 Photo 5 Plumbing 14) - One or more sections of the Taexx through the wall pest control system installed in this home are cut or damaged. Repairs should be made as necessary. Page 7 of 8

SUMMARY Photo 62 Page 8 of 8