DWP-5500FP (4 x4 ) DWP-11KRFP (5 X5 ) Weighing Indicator. User Manual. Content

Similar documents
Weighing Indicator YH-T3. User Manual

WS 10 Weighing indicator USER MANUAL

User Manual. XK315A1 water proof series Weighing Indicators. Applications: Electronic platform scale, weighing scale, etc.

Weighing Indicator VI 150

OP-903 INDICATOR USER S MANUAL

LOW PROFILE FLOOR SCALE

SE9000 Digital Weighing Indicator. User manual

PALLET SCALE CPS SERIES OWNER'S MANUAL

Weighing Indicator Version April 2009

CN Series P.N , Software rev. T 8, Revision A1- July 2014

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

Operation Manual. Dual Temperature Digital Dry Block Incubator. Catalog No. INCUBATOR Rev C. April 2016

Operation Manual INCUBATOR2 Dual Dry Block Incubator

Solar controller for thermalsophin system SR609C operation manual Contents

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

Operator Manual. OHAUS Aviator 7000

User s Guide. Weighing Indicator WIDRA - HF L / HF S 2000/02/11 21:21:58. No. TARE NET GROSS TOTAL

Table of contents. 1. Introduction

BEFORE USING THE COUNTING SCALE

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

MANUAL JCE-SERIES CHAPTER

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

Operating Manual. Professional Weighing Equipment. TB Series intelligent weighing machine. Touch Color Screen HIGH RESOLUTION BALANCE

EC Type-Approval Certificate

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

HX-Series. HX-502 (500g x 0.01g) HX-3001 (3000g x 0.1g. Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

Solar Eye User Manual

Inscale Measurement Technology Ltd Tel: Fax:

HOBO Plug Load Logger (UX ) Manual

LC-VS 60 Operation Manual

Models TJ30K TJ15K TJ6K TJ3K. Resolution Ratio 1g 0.5g 0.2g 0.1g Calibration graduation 10d 10d 10d 10d

Exceed IRELAND Electronic Postage Computing Scale

Adam Equipment LBC SERIES. (P.N , RevisionB1, January 2010)

X320 IP69K. Digital Indicator Operator Manual 003X M02

Table of Contents. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

High Precision Balances. Operation Manual

PD- OWNER S MANUAL. ECR Interface Scale 9002-PD

Galaxy 300 and Galaxy 300i

VWR B-Series Balances Operation Manual

MEDIZINTECHNIK FÜR TIERÄRZTE

Manual. AGRETO Hydraulic Scale AGRETO electronics GmbH

Model: 770 Light Vehicle Scale Size: 8 x30 x5 Size: 10 x30 x5 Capacity: 40K CLC: 20K Capacity: 60K CLC:30K Installation, Set-Up and Operation Manual

64C Amplification Block. Instruction Manual

User Manual. Precision Balances XSR models

Adam Equipment LBC SERIES. (P.N , RevC, August 2011)

EC Series Toploading Balances

Galaxy 300. Operation 05/

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

S-1600 Series Currency Counter Operating Manual. Models S-1600, S-1615 and S-1625 Including "V" Series

iloader LTS On-Board Scale for Front Loader (User Manual)

Quick Guide. ICS4 / ICS68_ Weighing systems

CSG A.L.C. COUNTING SCALE USER MANUAL

WeighSouth. WBT Toploader Balance

Professional Weighing Equipment REMO/REMO-R. Operation Manual

Operating instructions Analytical balance

Professional Weighing Equipment Digital Weight Indicator

MS 3801 USER MANUAL. Manufactured by: Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.

XPI SERIES GRID SOLAR POWER SYSTEM

Instruction number PTI-16-03/09/06/A

Operating Manual. Professional Weighing Equipment SCT SERIES Small Counting Scales. SCT 600g SCT 1200g

BC Series Compact Counting Scale INSTRUCTION MANUAL

PORTION CONTROL SCALE

Certificate of EC type-examination of a measuring instrument Number: UK/0126/0013 Revision 1

Sby SR Instruments, Inc.

DS-520 Digital Indicator Operation Manual 73366

High Precision Balances

Instruction Manual Pocket scale

Topics / products covered

Topics / products covered

Coefficient of Friction Tester

DIGITAL PORTION SCALE PS-5 OWNER S Manual

KERN EMS Version /2012 GB

Operation Instruction Manual

Operating manual Pallet scale

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

Gemini Tech CO., LTD.

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

Camera Eyepiece. User s Manual. KS035200G4-Ver1.0

PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

OPERATION MANUAL. Electronic Hanging Scale NINGBO AUDDA WEIGHING CO.,LTD

Kilotech weighing scale KWS-CY. Owner s Manual V1.0

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

Manual YJXB-3 STEEL & CASTING WELDER

Certificate of EC type-examination of a measuring instrument Number: UK/0126/0082

The Ton-Tel Weighbridge

PART NO. : WC0802C V1.0 FOR MESSRS. : T h e L C D ( M ) S p e c i a l i s t -SFYLYHTC06 PAGE: 1/17 CONTENTS WC0802CV1.

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

Wealtec Corp. E-Centrifuge Microcentrifuge Operation Manual. Version 3.0 Item # *This instrument is intended for laboratory use only

CONTENTS Cautions before using 1-2. Specification and characteristics of products

Contents. 1. About this edition of user instructions

FIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL

ProColor Flat Panels. User Manual. 151 NE State Hwy 300, Ste A Belfair, WA

Professional Weighing Equipment. Wheelchair Scale. Operating Manual LWC 800

BA110 Electronic Balance 5000g x 1g. Impact Test Equipment Ltd & User Guide. User Guide

DJ Switch 10F V2 ORDERCODE 50365

! CAUTION: Read and follow these instructions.

Contents Balance-pan fixing

INSTALLATION uline.com UNPACKING ASSEMBLY LEVELING H-1096, H-1097 H-1098, H-1099 DELUXE COUNTING SCALE

Transcription:

DWP-5500FP (4 x4 ) DWP-11KRFP (5 X5 ) Weighing Indicator User Manual Please read the user manual carefully before using Please keep the user manual properly for future reference Content CHAPTER 1 MAIN SPECIFICATION CHAPTER 2 INSTALLATION CHAPTER 3 INDICATOR 2

Chapter 1 Main Specification 1. Model: DWP-F SERIES NTEP Floor / Pallet scale 2. Accuracy: GradeⅢ, n=5000 3. Sample Rate: 10 times/second 4. Load cell sensitivity 1.5~3mV / V 5. Scale interval: 1/2/5/10/20/50 for option 6. Display: 6 bits LED, 8 state indicating signals 7. Power supply: AC100V~230V,50~60HZ 8. Operating temperature/humidity: 0~50 ; 90%RH 9. Transporting temperature: -20~60 2.0 SCALE BASE SETUP Chapter 2 Installation a. Open the scale base box (Box 1) with a knife very carefully. Sharp blade may scratch the scale surface. 2

b. Take out the scale feet (total 4 feet packed in the box inside the scale base) c. Screw each foot ontothe load cell at each corner of the scale base. 3

d. Take out the indicator from Box 2. Plug the scale serial cable into the socket on the back of the indicator. And use a screw driver to tighten the two screws of the plug. Turn on the indicator by pressing the ON/OFF button on the front of the indicator. Now your scale is ready to use. For advanced operations, please refer to the following pages. CHAPTER 3 INDICATOR The connection between load cell and indicator must be reliable. The shield cable of load cell must be grounded firmly. Do not plug or unplug the connection wire while the indicator is powered up to avoid damages to indicator or load cell by static electricity. Indicator and load cell are static sensitive device and anti-static measures must be adopted in use. In the thunderstorm season, a reliable lighting protection measure must be installed to avoid damage of indicator or load cell by lightning. Make sure the safety of operator and the safe operation of weighing equipment and associated equipment. Do not use in the place where there is inflammable gas or vapor. Do not use in the pressure hopper system. Keep the indicator and load cell away from high electric field, magnetic field, strongly corrosion object and flammable object. Do not clean the housing with strong solvent (such as benzol and nitro oil). Do not inject liquid or conduction grain into the indicator to avoid damage to indicator or electric shock. Do not open the lead sealing without authority from department of electrical supervision. Calibration can not be done without breaking the lead sealing. Rechargeable battery is consumable and is not covered by guarantee. To prolong the life of use of rechargeable battery, be sure to use after it is fully charged. If the indicator won t be used for long time, it is must be recharged once in 2 months and charged for 20 hours each time. Be carefully while moving or installing to avoid strong shaking or impact, to prevent short circuit or damage to rechargeable battery. The indicator should be placed flatly and not be in the straight sunshine for clear indication and long-term service life. The indicator should not be placed in a vibrating area full of dust, and not in a sloppy environment. Before connecting or disconnecting indicator and peripheral equipment, powder supply of the indicator and other devices should be firstly switched off! Regulations about external connection in the manual should be strictly observed. It is not allowed change the connection at random. It is not allowed to open the indicator, otherwise we do not guarantee to repair. There is high voltage inside the indicator. Non-professional people are not allowed to repair to avoid more serious damage to system and human or accident. If not man-made trouble happens within one year after the date of sale, the indicator is under regular service condition, please send the troubled indicator and guarantee card (the serial number should be coincident) to the special repair shop or the supplier. While it is over guarantee time, man-made trouble or other accidental damage, the manufacturer will repair with charge. Printed version might be slightly different from product because of the improvement of product function. Please contact the manufacturer from latest version.

The right of revising this manual is preserved. 1)Technical parameters Input Sensitivity: 1.5uV/e A/D Conversion: Δ-Σ technique,20bit Supply bridge Voltage of load cell: DC 5V, can connect 1-4 pcs of 350Ω strain gauge load cells; Connection with load cell:use 4 wires Division value: 1/2/5/10/20/50/100 optional Display: 6 bits LCD display Clock display: Display the year/month/day, hour/minute/second, automatic leap year, leap month. No need to reset after power off. Character setting: Chinese/English is available for printing Scoreboard interface: current loop serial output method, 600bps Printer interface: Inner thermal micro-printing,57mm width paper, diameter of the paper reel 40mm Power supply : AC110~220V, 50~60Hz, can external connect DC 6V/7Ah free maintenance lead-acid battery(optional). Size of the indicator: 240*173*187mm(long*wide*height) Weight of the indicator: about 1.15 (kg) Operation environment: Operating temperature: 0 ~40 Operating Humidity: 85%(RH),No condensation Storage environment::storage temperature: -10 ~50 Storage Humidity: 95%(RH),No condensation 2)Installation 2.1 Indicator Diagram Sketch Front board Back board Remark:The 9 hole interface at back is for connection with load cell,9 pin interface is for scoreboard connection. 2.2 Screen of the Indicator Zero Stable N.W. %:Sum OZ:Inner code kg:kilogramme

Animal status Battery condition 2.3 Connection with Load cell Animal weighing stable Description location description code 1 Load cell negative excitation E- 2 Load cell negative feedback F- 6 Load cell positive excitation E+ 7 Load cell positive feedback F+ 8 Load cell signal input - S- 9 Load cell signal input + S+ 5 Shield cable SHIELD This indicator is connecting with 4 wires cable, user must make the short circuit for positive excitation and positive feedback negative excitation and negative feedback!the connection of load cell and indicator should be relible. The shield wire of load cell must be connected to the earth. It is not allowed to connect or disconnect with power supply. Avoid damage to indicator or load cell by static electricity.!load cell and indicator are static sensitive devices, so static-proof measures should be adopted. 2.4 The connection with scoreboard Scoreboard mating plug DB9 core terminals Scoreboard 3 9 Communications 5 5!The connection between scoreboard and indicator scoreboard output must be correct, if with wrong connection, it will cause damage to output interface of indicator or input interface of scoreboard.even it will damage seriously indicator and scoreboard. Special connection cable shall be used. The scoreboard will display nothing when the indicator is under calibration status. 3) Operation 3.1 Startup and startup Auto-Setting Zero 1 Power on and turn on the power switch, the indicator will have self-inspection.then it will enter weighing status directly. 2 when startup, if the displayed data is not zero, but still in setting range, the indicator will set zero automatically. Startup zero setting rand and method is refer to the calibration chapter

During normal working, the calibration switch should be on forbidding position (down place) 3.2 Manual zero setting (semi-automatic) 1 When the displayed data is not zero, but still in the range of setting, the key ZERO can be operated. Otherwise, it is not available. Zero setting parameter selection and setting is refer to the calibration chapter. 2 Zero setting is available only when the stable indication is light. 3.3 Tare 1 Under weighing status and with stable platform, indicator can do tare operations continuously. 2 When it conform to zero setting conditions, press ZERO to set tare as zero. The light of net weight will be off. 3.4 Operations of animal scale function Step Operations Display Note 1 Press[SET] Press[0] Press[ENTER] [******] Under weighing status 2 Under animal scale weighing status, press [WEIGHING] to exit 3.5 ISN code operations Step Operations Display Note 1 Press[SET] Press[2] Press[ENTER] [******] Under weighing status 2 Under ISN code status, press [WEIGHING] to exit 3.6 Setting for backlight language and printing sn Step Operations Display Note 1 Press[SET] Press[1] Press[ENTER] [US ] Under weighing status 2 Press[000] Press[ENTER] [ST XYZ] [ST 000] Note: Auto-zero setting after setting Z value,refer to note 1 Default setting in Factory:000 3 Weighing status Note1:special statement, for english verison indicator, Y value is always 1. Input value 0 1 2 X:screen backlight Auto-backlight Backlight off Backlight on Y:print language chinese english Z:clear printing serial no. Not clear clear When accumulation symbol % is on,print accumulated weight value.

3.7 Printing 1) No tare printing step description operations display note 1 Load goods [******] Showing current weight 2 stable Press[PRINT] [ Print ] Print current data 3 Printing is [******] Return to weigh after printing finished 2)Tare printing step description operations display note 1 Load tare [******] Showing current weight 2 stable Press [TARE] [ 0] Showing N.W.=0 3 stable Load goods [******] Showing current weight 4 stable Press[PRINT] [ Print ] Print current data 5 Printing is finished 3) Accumulation printing [******] Return to weigh after printing When accumulation symbol % is on,the printed data is accumulated weight value. Press [CLEAR], accumulation symbol % is off, the accumulated data is clear up. 4) Complementary printing Press [REPRINT] to print the latest record. Note: If the power shows 1 grid, please print after charging up or connecting with AC power supply in time. If the weight is smaller than 5 intervals value, it can not printing. 3.8 Accumulation function 1 Sum operation. Under weighing status, to press[σ] after platform is stable,then the indicator will display times of accumulation and total weight, then return to weighing status. It can start to sum again only after the scale returns to zero. 2 Clear up of the summary data. Under weighing status, to press [CLEAR] to clear up records of sum times and total weight. 3 Checking summary data. Under weighing status, to press [Σ] when the indicator displays zero. The indicator will show summary times first and total weight, then return to weighing status. Note:The summary data can not be saved after power off,during summing status, the light of % is on. 3.9 Date and time setting 1 Under weighing status, press[date] then the indicator will display current date. If correct, then press [ENTER] or [WEIGHING] to exit.if not correct, input numbers and press [ENTER] 2 Under weighing status, press[time] then the indicator will display current time and run automatically. If correct, then press [WEIGHING] to exit.if not correct, input numbers and press [ENTER]. 3.10 Use of storage battery(storage battery is extra requirement ) 1 With storage battery and AC power supply connected, if not able to start up the indicator, it maybe in condition of lower power supply. Please wait to charge the battery or operate with AC power after unloading the battery. 2 The red connects to the positive pole of stock battery,the black connects to negative pole.please note!( the connection line of storage battery is optional) 3 If only with storage battery, there is a signal on the display of indicator showing the battery condition. With full lights on, it means enough power.if only lower one is light, please charge up in time. 4 Please charge up the battery completely at first time.if without use for long time, we suggest to charge the

battery each 2 months for 20hours.Move the devices slightly in order to avoid strong shock and impact which easily causes short circuit inside of the battery, and destroy the battery. Specially warning: If without confirmation from technology monitoring department, please do not break the seal on the product, can not calibrate without breaking the seal. 4 Information prompt 4.1 Normal information prompt Display Print Lbat Note Please wait, data are transmitting between indicator and printer Power is too low to print,please charge up. 4.2 Error prompt Display Err 01 Err 02 Err 03 Err 06 Err 16 Err 22 Err 19 Err P Err 18 Err 09 Note Error on automatic zero-setting or by hand Error on summary overloading Error on tare operations Error on date and time setting Error on clock cores Not able to print when zero, minus weight or not stable weight Error on printer Error on parameter setting Error on inspection of calibration data Annex 1: Function of charging It is available to charge up with DC currency, please use 6V/7Ah for storage battery. Interface connection is negative for outside and positive for inside. If the battery is with opposite connection, it will make damage to the indicators.please note. This product is not provided with storage battery, if you need, please order additionally. Note: 1.We do not guarantee damage to the battery itself with wrong connection. 2.When charging up, if fail to start up the indicator maybe for lower power, please try again after charging. Annex 2: Print form Indicator Weight list --------------------------------------------- Item: 0001 Date: 10-06-06 Time: 06:06:06

G.W.: 8000(kg) Tare weight: 1300(kg) N.W.: 6700(kg) ---------------------------------------------- Weighing Bill ----------------------------------------------- S.N.: 0001 Date: 10-06-06 Time: 06:06:06 GW: 8000(kg) TW: 1300(kg) NW: 6700(kg) ------------------------------------------------