Report No 2370/ Part 1 of 2 Issue 3 This Report consists of 15 pages. Authority & date BSI Service Management Order Number

Similar documents
Report No 2370/ Part 2 of 2 Issue 2 This Report consists of 10 pages. Authority & date BSI Service Management Order Number

Test Report IMS Nederland B.V.

EASY GLASS HYBRID POST FASCIA MOUNT

EASY GLASS HYBRID WALL CONNECTION

EASY GLASS MOD 6400 BASE GLASS CLAMP

TEST REPORT (QT39584/2/JPS)/Ref. 10/Supp1. Lucideon Reference:

TEST REPORT. Lucideon Reference: (QT39584/2/JPS)/Ref. 11

EASY GLASS JULIET BALCONY MOD.6507 & 6508

TEST REPORT. Lucideon Reference: (QT-49195/1/GMB)/Ref. 1. Testing of OnLevel TL6020 Balustrade System in Accordance with BS 6180:2011

TEST REPORT. Lucideon Reference: (QT39584/2/JPS)/Ref. 5

TEST REPORT. Lucideon Reference: (QT39584/2/JPS)/Ref. 2

STRUCTURAL CALCULATIONS

TEST REPORT. Spig Lite Pro. Frameless Balustrade. Testing carried out by: Queens Road Penkhull Stoke On Trent

STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

TEST REPORT Juliet Balcony System - SKYFORCE

STRUCTURAL CALCULATIONS

TEST REPORT. Lucideon Reference: (QT44718/2/RK)/Ref. 6

BS 6180: 1999: Barriers in and about buildings Code of practice - General Contract use Clauses 6.4.1

TEST REPORT. Lucideon Reference: (QT44718/2/RK)/Ref. 8

STRUCTURAL CALCULATIONS

TEST REPORT. Lucideon Reference: (QT-49116/2/RK)/Ref. 1

TEST REQUIREMENTS : RESULT : BS 6180: 1999: Barriers in and about buildings Code of practice - Communal domestic use Clauses 6.4.1

BS 6180: 1999: Barriers in and about buildings Code of practice - Domestic Use Clause 6.4.1

TEST REQUIREMENTS: BS 6180:2011: Barriers in and about buildings Code of practice : Domestic applications Clause 6.4.1

TEST REQUIREMENTS : RESULT : BS 6180: 1999: Barriers in and about buildings Code of practice - Communal domestic use Clauses 6.4.1

BS 6180: 1999: Barriers in and about buildings Code of practice - General Contract use Clauses 6.4.1

STRUCTURAL CALCULATIONS

BS 6180: 1999: Barriers in and about buildings Code of practice - General Contract use Clauses 6.4.1

APPROVED DOCUMENT K PROTECTION FROM FALLING, COLLISION & IMPACT. The Building Regulations 2010 PART K

Frameless Glass Balustrades Product Information Sheet

Load testing of a PVC coated handrail system. 25 th March Test report number

Updated May BALUSTRADE & FENCE DESIGN

The Infinity Balustrade System

Test Report. Test Report Debar Ltd. Page 1 of 20

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

Dear Customer. Section Old F4 January 2017 Amendment 2. Remove title page and document history page 1-2B

For New Zealand Building Code Clause F4 Safety from Falling

Guidelines for SINTEF Technical Approval Glass railing Railing with glass as complementary or load carrying element

CITY OF TORONTO. BY-LAW No (OMB)

Approved Document. Protection from falling, collision and impact. The Building Regulations 2010

Acceptable Solution F4/AS1

Introduction 2 The Guidance Existing Buildings Technical Specifications Materials and Workmanship Interpretation. Part K : The Requirement 3

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

ARCHIVED. Compliance Document for New Zealand Building Code Clause F4 Safety from Falling Second Edition

MAIN CHANGES IN THE 1998 EDITION

Protection from falling, collision and impact

Example. Monday, October 19, 2015

SPECIFICATION FOR PRECAST/ COMPOSITE CONCRETE FLOORS/ ROOF DECKS SECTION E60

Glazing Assembly Design Review Engineering Analysis of Absolute TRFM Railing System

glass interiors BALUSTRADES CATALOG

roof walkway systems C1/Sfb(23)Xh 03.11

CARPENTER TRADE REGULATION

COLUMBIA COUNTY LAND DEVELOPMENT SERVICES COURTHOUSE ST. HELENS, OREGON PHONE (503) CODE SUMMARY REQUIREMENTS

The Edge Protection Federation Containment Systems Product Specification, Test Methods

Bylaw A Bylaw to amend Bylaw 12800, as amended, The Edmonton Zoning Bylaw Amendment No. 2409

SAFE WORK METHOD STATEMENT

Vehicle Impact Barriers for Elevated Structures

LIV BUILDING PRODUCTS TEST REPORT

TECHNICAL INSTALLATION

LICENCE. for. Click on the red box above to activate the Licence Agreement scroll bar. WEB LINKS

Main Contractors, Builders and Developers

NATIONAL ANNEX TO STANDARD. SFS-EN EUROCODE 1: ACTIONS ON STRUCTURES Part 1-7: General actions Accidental actions

Copyright Materials

Chartered Membership Examination

General Building Information

Annotated Accessibility Changes to the 2012 Ontario Building Code, as Amended by Ontario Regulation 368/13

Document. Protection from falling, collision and impact

Code Compliance Research Report CCRR-0187

STATE UNIVERSITY CONSTRUCTION FUND

South Main Station. 150 Main Street, Longmont, Colorado 16" COMMON PARAPET DETAIL AREA. Date

FINAL DRAFT pren

Barrette Outdoor Living. 135 Steelmanville Road Egg Harbor Township, NJ USA, 08234

RepublicofSouthAfrica

INTERNATIONAL CODE INTERPRETATIONS

ELEVATOR CONSTRUCTOR TRADE REGULATION

Appendix 2 CORBY BOROUGH COUNCIL A GUIDE TO PARKING STANDARDS FOR NEW DEVELOPMENT

Code Compliance Research Report CCRR-0238

ALSPEC ALUMINIUM SYSTEMS TECHNICAL MANUAL

Code Compliance Research Report CCRR 0277

Technical Booklet Date of Issue Page. D Structure June 1994 ii. E Fire safety June 1994 iii. G Sound June 1990 iv

Australian/New Zealand Standard

Code Compliance Research Report CCRR-0238

Frameless Glass Balustrade and Pool Fencing Systems

RHINO-STOP Modular Vehicle Impact Barriers

Design Manual for M.C.M.E.L Railing System

INSTALLATION OF NEW FURNACE CALCINER 2

SOUTH AFRICAN NATIONAL STANDARD

All- Glass Staircase, Notting Hill, London

CHAPTER 24 GLASS AND GLAZING

Volume 3 - Section I Method of Measurement for Road Works. Chapter TV - Series 100 Preliminaries

TN002 New Zealand Seismic Installation Guide

EASY GLASS MAX FASCIA MOUNT MOD.6935

Fall prevention through windows: barriers and balustrades (Nat)

Technical Guidance Note

MODEL CLAUSES FOR CIVIL ENGINEERING WORKS

(Old examination format for reference only)

Lightweight and Stable

Building Codes and Ordinances ARC 227

GLASS RAILING SYSTEMS

Transcription:

Test Report Report No 2370/8710132 Part 1 of 2 Issue 3 This Report consists of 15 pages Licence/Certificate No KM 656489 Client Q-Railing Europe GmbH & Co.KG Marie-Curie-Strasse 8-14 Emmerich am Rhein 46446 Germany Authority & date BSI Service Management Order Number 8710132 Items tested Easy Glass View Barrier System Standard BS 6180:2011 clauses 6.3.1 and 6.4.1 only Type testing for product certification Issue 3 of this report supersedes all previous issues. The amendments on pages 3 and 13 giving rise to this issue can be ascertained by contacting the authorising signatory. Results See text Prepared by G R Essam Principal Engineer Authorized by M Manito..Team Manager Issue Date 14 June 2017 Conditions of issue This Test Report is issued subject to the conditions stated in current issue of 'BSI Terms of Service'. The results contained herein apply only to the particular sample(s) tested and to the specific tests carried out, as detailed in this Test Report. The issuing of this Test Report does not indicate any measure of Approval, Certification, Supervision, Control or Surveillance by BSI of any product. No extract, abridgement or abstraction from a Test Report may be published or used to advertise a product without the written consent of BSI, who reserve the absolute right to agree or reject all or any of the details of any items or publicity for which consent may be sought. BSI Maylands Avenue Hemel Hempstead Hertfordshire HP2 4SQ Telephone: +44 (0) 3450 80 9000

Page 2 of 15 TESTING AND EXAMINATION OF A BARRIER SYSTEM SUBMITTED AS TYPE TEST SAMPLES INTRODUCTION For the purposes of product certification the barrier system submitted on behalf of Q-Railing Europe GmbH & Co and detailed below was tested against the recommendations of BS 6180:2011 clauses 6.3.1 and 6.4.1 only, as detailed in the following pages of this Report. It is emphasized that assessments have not been made to the Standard. The testing was supervised at the Emmerich am Rhein site of Q-Railing Europe GmbH & Co on 11 and 12 April 2017. TEST ITEMS Easy Glass View Barrier System, model number 6923, with the following glass panels: A) 1800mm x 1100mm x 12.76mm two layer toughened glass 1) B) 2000mm x 1100mm x 12.00mm monolithic toughened glass C) 2200mm x 1100mm x 16.76mm two layer toughened glass 2) D) 2500mm x 1100mm x 15.00mm monolithic toughened glass E) 2500mm x 1100mm x 16.76mm two layer toughened glass 2) F) 2500mm x 1100mm x 21.52mm four layer toughened glass G) 3000mm x 1100mm x 21.52mm four layer toughened glass Notes: 1) Also applicable to 13.52mm four layer toughened glass 2) Also applicable to 17.52mm four layer toughened glass

Page 3 of 15 EXAMINATION AND TEST CLAUSE 6 DESIGN CRITERIA 6.3 Loading 6.3.1 General 6.4 Deflection Minimum horizontal imposed loads appropriate to the design of parapets, barriers, balustrades and other elements of structure intended to retain, stop or guide people, should be determined in accordance with Table 2 [of BS 6180:2011], which recommends a uniformly distributed line load for the barrier and a uniformly distributed and point load applied to the infill. These are not additive and should be considered as three separate load cases, all loads being determined according to the type of occupancy which reflects the possible in-service conditions. Horizontal uniformly distributed line loads should be applied at the design height as presented in Table 1 [of BS 6180:2011] or at the design level 1100mm for barriers higher than the design height. Uniformly distributed load should be applied at the area below the design height. Point load should be applied at the most onerous point anywhere on the barrier structure. 6.4.1 Barriers for the protection of people Barriers for the protection of people should be of adequate strength and stiffness to sustain the applied loads given in Table 2 [of BS 6180:2011]. In addition, a barrier that is structurally safe should not possess sufficient flexibility to alarm building users when subject to normal service conditions. Therefore, for serviceability considerations, the limiting condition for deflection appropriate for a barrier for the protection of people is that the total horizontal displacement of the barrier at any point from its original unloaded position should not exceed the deflection limits determined from the relevant structural design code (where applicable) for the material used, or 25 mm, whichever is the smaller. Where the infill of a barrier is subjected to imposed loads given in Table 2 [of BS 6180:2011], or if appropriate, other calculated design loads, the displacement of any point of the barrier should not exceed L/65 or 25 mm, whichever is the smaller where L is the given in 8.3, 8.4 or defined in 8.5 [of BS 6180:2011]. A suitable fracture load, factored by a minimum partial safety factor of 4.0 (as recommended in BS 4592-0) should be obtained from the material manufacturer when considering glass barrier design.

Page 4 of 15 Table 2 Minimum horizontal imposed loads for parapets, barriers and balustrades Type of occupancy for part of the building or structure Domestic and residential activities Offices and work areas not included elsewhere, including storage areas Areas where people might congregate Areas with tables or fixed seatings Areas without obstacles for moving people and not susceptible to overcrowding Examples of specific use (i) All areas within or serving exclusively one single family dwelling including stairs, landings, etc. but excluding external balconies and edges of roofs (ii) Other residential, i.e. houses of multiple occupancy and balconies, including Juliette balconies and edges of roofs in single family dwellings (iii) Light access stairs and gangways not more than 600 mm wide (iv) Light pedestrian traffic routes in industrial and storage buildings except designated escape routes Horizontal uniformly distributed line load (kn/m) Uniformly distributed load applied to the infill (kn/m 2 ) 0.36 0.5 0.25 0.74 1.0 0.5 0.22 - - 0.36 0.5 0.25 (v) Areas not susceptible to overcrowding in office and institutional buildings, also industrial and storage buildings except as given above 0.74 1.0 0.5 (vi) Areas having fixed 1.5 1.5 1.5 seating within 530 mm of the barrier, balustrade or parapet (vii) Restaurants and bars 1.5 1.5 1.5 (viii) Stairs, landings, corridors, ramps 0.74 (ix) External balconies including Juliette balconies and edges of roofs. Footways and pavements within building curtilage adjacent to basement/sunken areas 0.74 1.0 0.5 0.74 1.0 0.5 A point load applied to part of the infill (kn)

Page 5 of 15 Table 2 Minimum horizontal imposed loads for parapets, barriers and balustrades (Continued) Type of occupancy for part of the building or structure Areas susceptible to overcrowding Examples of specific use (x) Footways or pavements less than 3 m wide adjacent to sunken areas (xi) Theatres, cinemas, discotheques, bars, auditoria, shopping malls, assembly areas, studio. Footways or pavements greater than 3 m wide adjacent to sunken areas. (xii) Grandstands and stadia A) Horizontal uniformly distributed line load (kn/m) Uniformly distributed load applied to the infill (kn/m 2 ) 1.5 1.5 1.5 3.0 1.5 1.5 - - - A point load applied to part of the infill (kn) Retail areas Vehicular (xiii) All retail areas including public areas of banks/building societies or betting shops 1.5 1.5 1.5 (xiv) Pedestrian areas in car 1.5 1.5 1.5 parks, including stairs, landings, ramps, edges or internal floors, footways, edges of roofs (xv) Horizontal loads - - - imposed by vehicles B) A) See requirements of the appropriate certifying authority B) See Annex A

Page 6 of 15 TEST METHODS A single section of each size of barrier system was bolted to a metal structure with an I section measuring nominally 240mm x 240mm in accordance with the manufacturer s instructions. The structure was, in turn, fixed to the concrete floor of the testing facility. Horizontal uniformly distributed line loads The horizontal uniformly distributed line loads were applied to the upper edge of the glass using a number of equally spaced pneumatic cylinders operating through wire ropes and pulleys. The common air pressure supplied to each cylinder was measured using a calibrated load cell and display unit. The deflection measurements of the upper edge of the glass were taken from a fixed datum point at the same level using a calibrated digital indicator. Typical arrangement for application of horizontal uniformly distributed line loading assembly Uniformly distributed load applied to the infill The uniformly distributed loads were applied to the glass in a horizontal orientation with the mounting profiles of the barrier system clamped to steel girders, as described above, using bags of sand. The loads were calculated according to the total glass area. The deflection measurements at the centre of the glass were taken from fixed datum points using a calibrated digital indicator.

Page 7 of 15 TEST METHODS (Continued) Uniformly distributed load applied to the infill (Continued) Typical arrangement for application of uniformly distributed load applied to the barrier system

Page 8 of 15 TEST METHODS (Continued) Point load applied to part of the infill The point loads were applied to the centre of the glass through a 100mm x 100mm wooden block using a hydraulic cylinder. The loads were measured using a calibrated load cell and display unit. The deflection measurements on the opposite side of the glass to the loading point were taken from a fixed datum point using a calibrated digital indicator. Typical arrangement for application of point load to the centre of the barrier system

Page 9 of 15 TEST METHODS (Continued) Easy Glass View assembly drawing

Page 10 of 15 TEST METHODS (Continued) Easy Glass View assembly drawing

Page 11 of 15 TEST METHODS (Continued) Easy Glass View assembly drawing

Page 12 of 15 SUMMARY OF TESTING Horizontal uniformly distributed line loads System Mount Glass size (WxH) (mm x mm) Easy Glass View System Side A) 1800 x 1100 Inside A) 1800 x 1100 Inside 2) B) 2000 x 1100 Inside 2) C) 2200 x 1100 Inside 2) D) 2500 x 1100 Inside 2) E) 2500 x 1100 Inside 2) F) 2500 x 1100 Inside 2) G) 3000 x 1100 Notes: 1) Recorded for information 2) Also applicable to side mounted system 3) Marginal result Glass type 12.76mm 12.76mm 12.00mm monolithic 16.76mm 15.00mm monolithic 16.76mm 21.52mm 21.52mm Line load (kn/m) Deflection (mm) 0.36 11.5 0.74 20.9 0.91 27.6 1) 0.36 10.8 0.74 20.2 0.90 26.9 1) 0.36 12.5 0.74 24.9 0.36 9.2 0.74 17.9 0.92 24.7 1) 0.36 12.3 0.74 25.1 3) 0.36 12.6 0.74 23.4 0.36 7.6 0.74 14.3 1.23 27.3 1) 0.36 13.5 0.74 28.1 1)

Page 13 of 15 SUMMARY OF TESTING (Continued) Uniformly distributed load applied to the infill System Mount Glass size (WxH) (mm x mm) Easy Glass View System Inside 2) A) 1800 x 1100 Inside 2) B) 2000 x 1100 Inside 2) C) 2200 x 1100 Inside 2) D) 2500 x 1100 Inside 2) E) 2500 x 1100 Inside 2) F) 2500 x 1100 Side G) 3000 x 1100 Glass type 12.76mm 12.00mm monolithic 16.76mm 15.00mm monolithic 16.76mm 21.52mm 21.52mm Area load (kn/m²) Deflection (mm) 1.0 16.2 1.0 18.8 1.0 15.1 1.0 26.2 1) 1.0 24.6 1.0 15.3 1.0 26.0 3) Notes: 1) Recorded for information 2) Also applicable to side mounted system 3) Calculated deflection by the manufacturer for information Point load applied to part of the infill System Mount Glass size (WxH) (mm x mm) Easy Glass View System Side A) 1800 x 1100 Inside A) 1800 x 1100 Inside 2) B) 2000 x 1100 Inside 2) C) 2200 x 1100 Inside 2) D) 2500 x 1100 Inside 2) E) 2500 x 1100 Inside 2) F) 2500 x 1100 Side G) 3000 x 1100 Glass type 12.76mm 12.76mm 12.00mm monolithic 16.76mm 15.00mm monolithic 16.76mm 21.52mm 21.52mm Point load (kn) Deflection (mm) 0.5 5.6 1.5 17.2 0.5 5.6 1.5 18.4 0.5 7.3 1.5 17.4 0.5 4.6 1.5 13.9 1) 0.5 7.7 1.5 22.9 1) 0.5 6.2 1.5 18.5 1) 0.5 3.2 1.5 9.6 1) 0.5 6.3 1) Notes: 1) Calculated deflections by the manufacturer for information 2) Also applicable to side mounted system

Page 14 of 15 SUMMARY OF SUITABILITY OF BARRIER SYSTEMS Type of occupancy for part of the building or structure Domestic and residential activities Offices and work areas not included elsewhere, including storage areas Areas where people might congregate Areas with tables or fixed seatings Areas without obstacles for moving people and not susceptible to overcrowding Examples of specific use (i) All areas within or serving exclusively one single family dwelling including stairs, landings, etc. but excluding external balconies and edges of roofs (ii) Other residential, i.e. houses of multiple occupancy and balconies, including Juliette balconies and edges of roofs in single family dwellings (iii) Light access stairs and gangways not more than 600 mm wide (iv) Light pedestrian traffic routes in industrial and storage buildings except designated escape routes Horizontal uniformly Easy Glass View System distributed line load (kn/m) A B C D E F G 0.36 0.74 X 0.22 0.36 (v) Areas not susceptible to overcrowding in office and institutional buildings, also industrial and storage buildings except as given above 0.74 X (vi) Areas having fixed 1.5 X X X X X X X seating within 530 mm of the barrier, balustrade or parapet (vii) Restaurants and bars 1.5 X X X X X X X (viii) Stairs, landings, corridors, ramps 0.74 (ix) External balconies including Juliette balconies and edges of roofs. Footways and pavements within building curtilage adjacent to basement/sunken areas 0.74 X 0.74 X

Page 15 of 15 SUMMARY OF SUITABILITY OF BARRIER SYSTEMS (Continued) Type of occupancy for part of the building or structure Areas susceptible to overcrowding Examples of specific use (x) Footways or pavements less than 3 m wide adjacent to sunken areas (xi) Theatres, cinemas, discotheques, bars, auditoria, shopping malls, assembly areas, studio. Footways or pavements greater than 3 m wide adjacent to sunken areas. (xii) Grandstands and stadia A) Horizontal uniformly Easy Glass View System distributed line load (kn/m) A B C D E F G 1.5 X X X X X X X 3.0 X X X X X X X - - - - - - - - Retail areas Vehicular (xiii) All retail areas including public areas of banks/building societies or betting shops 1.5 X X X X X X X (xiv) Pedestrian areas in car 1.5 X X X X X X X parks, including stairs, landings, ramps, edges or internal floors, footways, edges of roofs (xv) Horizontal loads - - - - - - - - imposed by vehicles B) End of Report