February 1, 2010 PARTIES INTERESTED IN EVALUATION REPORTS ON ROOF UNDERLAYMENTS FOR USE IN SEVERE CLIMATE AREAS

Similar documents
ACCEPTANCE CRITERIA FOR ROOF UNDERLAYMENT FOR USE IN SEVERE CLIMATE AREAS PREFACE

ACCEPTANCE CRITERIA FOR WATER-RESISTIVE BARRIERS PREFACE

June 1, 2010 PARTIES INTERESTED IN EVALUATION REPORTS ON REFLECTIVE FOIL INSULATION

June 1, 2009 PARTIES INTERESTED IN EVALUATION REPORTS ON STRUCTURAL WOOD-BASED PRODUCTS USED AS STUDS

April 1, 2015 PARTIES INTERESTED IN FLEXIBLE FLASHING MATERIALS

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

December 3, 2012 PARTIES INTERESTED IN INTUMESCENT FIRE-RESISTANT COATINGS FIELD-APPLIED TO PREFABRICATED WOOD I-JOISTS

July 23, 2010 PARTIES INTERESTED IN REFLECTIVE FOIL INSULATION

ACCEPTANCE CRITERIA FOR POLYMER-BASED AND POLYMER-MODIFIED EXTERIOR AND INTERIOR WALL CLADDING

The purpose of this memo is to respond to the comments received in response to the May 1, 2007, staff letter and the revised criteria.

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

December 1, 2014 PARTIES INTERESTED IN WATER-RESISTIVE BARRIERS

April 2, 2018 PARTIES INTERESTED IN CROSS LAMINATED TIMBER PANELS USED AS COMPONENTS IN FLOOR AND ROOF DECKS

June 9, 2008 PARTIES INTERESTED IN EVALUATION REPORTS ON TERMITE- RESISTANT FOAM PLASTICS

October 1, SUBJECT: Proposed Revisions to the Acceptance Criteria for Walking Decks, Subject AC R1 (WU/CA).

ROOFING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR SELF-ADHERED UNDERLAYMENTS FOR USE IN DISCONTINUOUS ROOF SYSTEMS

June 1, 2017 PARTIES INTERESTED IN POST-TENSIONING ANCHORAGES AND COUPLERS OF PRESTRESSED CONCRETE

June 22, 2009 PARTIES INTERESTED IN EVALUATION REPORTS ON COMPOSITE COLD-FORMED LIGHT GAGE STEEL AND CONCRETE MASONRY LINTELS

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

April 18, 2018 PARTIES INTERESTED IN ADHERED PORCELAIN TILE WALL CLADDING SYSTEM

October 3, Section 1.2 Scope and Section 6.6 were revised to clarify interior and exterior construction types allowed.

ACCEPTANCE CRITERIA FOR PRECAST STONE VENEER

ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE

ACCEPTANCE CRITERIA FOR PRECAST STONE VENEER PREFACE

February 1, SUBJECT: Proposed Revisions to the Acceptance Criteria for Staples, Subject AC R1 (EL/JF)

August 31, 2010 PARTIES INTERESTED IN EVALUATION REPORTS ON ACCESS FLOORS

UL Evaluation Report UL ER Issued: May 31, Revised: June 6, UL Category Code: ULEZ. CSI MasterFormat

October 12, Yours very truly, Gary G. Nichols, P.E., SECB Vice President. GGN/md Enclosure Evaluation Committee

June 1, 2012 PARTIES INTERESTED IN COLD-FORMED STEEL FRAMING MEMBERS

December 1, 2014 PARTIES INTERESTED IN STRUCTURAL WOOD-BASED PRODUCTS

PMG LISTING CRITERIA FOR STRUCTURAL ADHESIVE JOINING SYSTEMS FOR FITTINGS PREFACE

February 1, 2018 PARTIES INTERESTED IN DECK BOARD SPAN RATINGS AND GUARDRAIL SYSTEMS (GUARDS AND HANDRAILS)

August 1, Removed reference to the standard edition from Sections and

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

PMG LISTING CRITERIA FOR MULTILAYER PIPE AND FITTINGS ASSEMBLY FOR REFRIGERANT APPLICATIONS LC1036

The Rehabilitation of Existing Building Drains and Building Sewers by the

December 20, 2006 PARTIES INTERESTED IN EVALUATION REPORTS ON PATIO COVERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

ACCEPTANCE CRITERIA FOR METAL COMPOSITE MATERIAL (MCM) PREFACE

December 1, 2011 PARTIES INTERESTED IN ALTERNATE DOWEL-TYPE THREADED FASTENERS

December 20, 2006 PARTIES INTERESTED IN EVALUATION REPORTS ON ALTERNATE DOWEL-TYPE THREADED FASTENERS

SECTION FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

AC178. June (Effective July 1, 2003) Previously issued April 2001 PREFACE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

PMG LISTING CRITERIA FOR PUSH-FIT FITTINGS FOR POTABLE WATER TUBE AND RADIANT HEATING SYSTEMS LC1009

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

ACCEPTANCE CRITERIA FOR FASTENERS POWER-DRIVEN INTO CONCRETE, STEEL AND MASONRY ELEMENTS PREFACE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

SECTION 7307 CONCRETE/ CLAY TILE, METAL, SLATE AND ASPHALT COMPOSITION SELF-ADHERED/ PEEL & STICK ROOF UNDERLAYMENT

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

PMG LISTING CRITERIA FOR PRESS-CONNECTION FITTINGS FOR POTABLE WATER TUBE AND RADIANT HEATING SYSTEMS PREFACE

Analysis of Changes for the 6 th Edition (2017) Florida Codes

February 1, 2016 PARTIES INTERESTED IN EXTERIOR ULTRA-HIGH PERFORMANCE CONCRETE THIN WALL CLADDING PANELS

ACCEPTANCE CRITERIA FOR PREFABRICATED WOOD SHEAR PANELS PREFACE

April 18, 2018 PARTIES INTERESTED IN RAISED-DECK SYSTEMS INSTALLED OVER ROOF ASSEMBLIES OR EXTERIOR SUPPORTING STRUCTURES

December 29, 2009 PARTIES INTERESTED IN EVALUATION REPORTS ON COLD- INTERIOR NONLOAD- BEARING WALL ASSEMBLIES

ACCEPTANCE CRITERIA FOR EXPANSION BOLTS IN STRUCTURAL STEEL CONNECTIONS (BLIND-BOLTS) PREFACE

** REVISED BY THE CITY OF LOS ANGELES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

PMG LISTING CRITERIA FOR PERT-AL-PERT PIPE AND FITTINGS FOR REFRIGERATION APPLICATIONS LC1039. Approved Date: November 2015 PREFACE

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS

ARCHITECTS & SPECIFIERS : SHINGLES, TILES, & ROOF COVERINGS

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

INTERIM CRITERIA FOR EXTERIOR INSULATION AND FINISH SYSTEMS PREFACE

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

Scope. resistance expressed as a moment

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SECTION SELF-ADHERING SHEET FLASHING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

Guide Specification for the OSI QUAD Window and Door Flashing System

ESR-1190 Reissued December 1, 2013 This report is subject to renewal December 1, 2014.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

1. ICC ES AC51 Draft Changes, Masonry Veneer Manufacturers Association (MVMA) Comments, dated September 24, 2007, compiled by John Woestman.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

ATI Evaluation Service A Division of Architectural Testing Certification Services

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

An Urgent Bulletin from CSA International

SECTION 7307 ASPHALT SHINGLE ROOF UNDERLAYMENT

Section Pre-Applied Sheet Membrane Waterproofing

Transcription:

February 1, 2010 TO: PARTIES INTERESTED IN EVALUATION REPORTS ON ROOF UNDERLAYMENTS FOR USE IN SEVERE CLIMATE AREAS SUBJECT: Proposed Revisions to the Acceptance Criteria for Roof Underlayments for Use in Severe Climate Areas, Subject AC48-0210-R1 (WM/JV) Dear Madam or Sir: The revisions proposed to the subject acceptance criteria, as presented in the enclosed criteria draft, are being posted on the ICC-ES web site to allow for public comment. The revisions include: 1. Revising the title of the acceptance criteria to reflect code language. 2. Updating AC48 to the 2009 I-Codes, and deleting references to and requirements for the 1997 UBC. 3. Updating Section 1.3 (Referenced Documents) to reference the current editions of standards. Overall, changes to the section may be explained as follows: ASTM C 794, ASTM D 412, ASTM D 828 and ASTM D 1682 are not referenced by the 2009 IBC or IRC. References to ASTM C 794 and ASTM D 412 have been updated to the current editions. Industry input is requested on the effect of changing the referenced editions of these two ASTM standards. ASTM D 828 has been withdrawn by ASTM with no replacement. Industry input is requested as to the appropriate test standard (if needed) to use in place of ASTM D 828. ASTM D 1682 has been replaced by ASTM D 5034 and ASTM D 5035. Industry input is requested on the affect in AC48 of replacing ASTM D 1682 with ASTM D 5034 and ASTM D 5035. You are cordially invited to submit written comments, within 30 days of the date of this letter. Please use the comment form on the web site attaching any letters to the form. An explanation of the alternate criteria process can be found on our web site at http://www.icc-es.org/criteria_development/alternative_criteria_process.shtml.

AC48-0210-R1 2 All comments received in the 30-day comment period will be considered in preparing revisions to the criteria that may be considered at a future Evaluation Committee meeting. Comments received will be posted on the web site shortly after the close of the comment period. Your cooperation is requested in forwarding to the Los Angeles business/regional office all material directed to the Evaluation Committee. Parties interested in the deliberations of the committee should refrain from communicating, whether in writing or verbally, with committee members. The committee reserves the right to refuse communications that do not comply with this request. Newly approved acceptance criteria may involve test methods or test protocols that are not currently included in the scope of testing services offered by accredited testing laboratories. As noted in the ICC-ES Rules of Procedure for Evaluation Reports, the scope of the laboratory s accreditation must include the type of testing that is to be reported to ICC-ES. We encourage accredited laboratories to expand their scopes of accreditation to include testing under newly approved acceptance criteria. Please note that testing laboratories must be accredited by the International Accreditation Service (IAS) or by another accreditation body that is a signatory to the International Laboratory Accreditation Cooperation Mutual Recognition Arrangement. For further information, please contact IAS at (562) 699-0541, extension 3309, or send an e-mail to pmccullen@iasonline.org. Please submit all comments using the form on the web site. Attach any letters to the comment form. If you have any questions (not comments), please contact the undersigned at (800) 423-6587, extension 5686, or Jose Valencia, Staff Architect, at extension 5693. You may also reach us by e-mail at es@icc-es.org. Yours very truly, WFM/raf Enclosure Woods McRoy, P.E. Senior Staff Engineer cc: Evaluation Committee

www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council PROPOSED REVISIONS TO THE ACCEPTANCE CRITERIA FOR ROOF UNDERLAYMENT FOR USE AS METAL VALLEY FLASHING UNDERLAYMENT IN SEVERE CLIMATE AREAS, OR AS AN ICE BARRIER AC48 Proposed February 2010 Previously approved October 2005, January 2000, January 1998, July 1997, April 1997, April 1994, June 1990 PREFACE Evaluation reports issued by ICC Evaluation Service, Inc. (ICC-ES), are based upon performance features of the International family of codes and other widely adopted code families, including the Uniform Codes, the BOCA National Codes, and the SBCCI Standard Codes. Section 104.11 of the International Building Code reads as follows: The provisions of this code are not intended to prevent the installation of any materials or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved. An alternative material, design or method of construction shall be approved where the building official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety. Similar provisions are contained in the Uniform Codes, the National Codes, and the Standard Codes. ICC-ES may consider alternate criteria, provided the report applicant submits valid data demonstrating that the alternate criteria are at least equivalent to the criteria proposed in this document, and otherwise meet the applicable performance requirements of the codes. Notwithstanding that a product, material, or type or method of construction meets the requirements of the criteria proposed in this document, or that it can be demonstrated that valid alternate criteria are equivalent to the criteria in this document and otherwise meet the applicable performance requirements of the codes, ICC-ES retains the right to refuse to issue or renew an evaluation report, if the product, material, or type or method of construction is such that either unusual care with its installation or use must be exercised for satisfactory performance, or malfunctioning is apt to cause unreasonable property damage or personal injury or sickness relative to the benefits to be achieved by the use of the product, material, or type or method of construction.. Acceptance criteria are developed for use solely by ICC-ES for purposes of issuing ICC-ES evaluation reports.

PROPOSED REVISIONS TO THE ACCEPTENCE CRITERIA FOR ROOF UNDERLAYMENT FOR USE AS METAL VALLEY FLASHING UNDERLAYMENT IN SEVERE CLIMATE AREAS, OR AS AN ICE BARRIER 1.0 INTRODUCTION 1.1 Purpose: The purpose of this acceptance criteria is to establish the basis of recognition in ICC-ES evaluation reports of severe climate roof underlayment installed as metal valley flashing underlayment over solid sheathing on areas of the roof subjected to wind-driven snow or ice buildup as specified in Tables 15-B-1, 15-B-2, 15-D-1 and 15-D-2 of the 1997 Uniform Building Code (UBC) and, in areas where the average daily temperature in January is 25 F ( 4 C) or less or where there is a possibility of ice forming along the eaves causing a backup of water or installed as an ice barrier, as specified in Chapter 15 of the 2006 2009 International Building Code (IBC) and Chapter 9 of the 2006 2009 International Residential Code (IRC). 1.2 Referenced Documents: 1.2.1 2006 2009 International Building Code (IBC), International Code Council. 1.2.2 2006 2009 International Building Code (IBC), International Code Council. 1.2.3 1997 Uniform Building Code (UBC). 1.2.3 1.2.4 ASTM C 794-80 06, Test Method for Adhesion-in-peel of Elastomeric Joint Sealants, ASTM International. 1.2.4 1.2.5 ASTM D 412-98a 06ae2, Test Method for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers-Tension, ASTM International. 1.2.6 ASTM D 828-97, Test Method for Tensile Properties of Paper and Paperboard Using Constant-Rateof-Elongation Apparatus, ASTM International. 1.2.7 ASTM D 1682-64 (1975), Test Method for Breaking Load and Elongation of Textile Fabrics, ASTM International. 1.2.5 1.2.8 ASTM D 1970-01, Specification for Self- Adhering Polymer Modified Bituminous Sheet Materials, ASTM International. (See Table 1 for editions.) 1.2.6 ASTM D 5034-09, Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test), ASTM International. 1.2.7 ASTM D 5035-06(2008)e1, Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Strip Method), ASTM International. 1.2.9 ASTM E 96-00, Test Method for Water Vapor Transmission of Materials, ASTM International. 2.0 BASIC INFORMATION 2.1 Manufacturing Description: General information on the material and manufacturing process. 2.2 Product Description: Details regarding thickness, size, configuration, fastener locations, lapping of edges and ends, and any special precautions required for installation. 2.3 Product Identification and Installation Description: Installation instructions, method of packaging and field identification. Identification provisions 2 shall include the evaluation report number and the name or logo of the inspection agency. 2.4 Jobsite Product Preparation: Method of fieldcutting, trimming or forming; and treatment of cut edges and cut ends. 2.5 Testing Laboratories, Reports of Tests and Specimen Selection: 2.5.1 Testing laboratories shall comply with Section 2.0 of the ICC-ES Acceptance Criteria for Test Reports (AC85) and Section 4.2 of the Rules of Procedure for Evaluation Reports. 2.5.2 Test reports shall comply with AC85. 2.5.3 Sampling of the underlayments for tests under this criteria shall comply with Section 3.1 of AC85. 3.0 REQUIRED TEST DATA 3.1 UBC: For recognition under the UBC, the following data shall be submitted: Reports of tests showing compliance with ASTM D 1970 shall be submitted. For products tested under ASTM D 1970, a maximum water absorption limit of 3 percent is permitted, provided tests in accordance with Sections 4.9 and 4.10 of this acceptance criteria are submitted. Underlayments qualified under ASTM D 1970 shall be limited to use with mechanically fastened roof coverings only. As an alternative to ASTM D 1970, reports of tests complying with Section 3.2 of this acceptance criteria may be submitted. 3.1.1 Underlayments Used in Conjunction with UBC Table 15-B-1: Reports of tests complying with Section 3.2 or ASTM D 1970. For products tested under ASTM D 1970, a maximum water absorption limit of 3 percent is permitted, provided tests in accordance with Sections 4.9 and 4.10 of this acceptance criteria are submitted. 3.2 3.1.2 Underlayments Used in Conjunction with UBC Tables 15-B-2, 15-D-1 and 15-D-2: Alternative Testing: 3.2.1 3.1.2.1 Tensile strength tests in accordance with Section 4.1 on control, accelerated-aged and ultraviolet-exposed specimens. 3.2.2 3.1.2.2 Water-vapor transmission tests in accordance with Section 4.2 on control specimens. 3.2.3 3.1.2.3Pliability tests in accordance with Section 4.3 on control specimens. 3.2.4 3.1.2.4 Water-ponding tests in accordance with Section 4.4 on control and accelerated-aged specimens. 3.2.5 3.1.2.5 Peel-adhesion tests in accordance with Section 4.5 on control, seven-day water-immersed, accelerated-aged and ultraviolet-exposed specimens. Exception: Minimum two layers of cemented products attached to substrate with mechanical fasteners. 3.2.6 3.1.2.6 Cycling and elongation tests in accordance with Section 4.6 on control specimens.

PROPOSED REVISIONS TO THE ACCEPTENCE CRITERIA FOR ROOF UNDERLAYMENT FOR USE AS METAL VALLEY FLASHING UNDERLAYMENT IN SEVERE CLIMATE AREAS, OR AS AN ICE BARRIER 3.2.7 3.1.2.7 Accelerated aging in accordance with Section 4.7. 3.2.8 3.1.2.8 Ultraviolet exposure tests in accordance with Section 4.8. 3.2. IBC and IRC: For recognition under the IBC and IRC, reports of tests complying with Section 3.1.2 of this acceptance criteria or with ASTM D 1970 shall be submitted. For products tested under ASTM D 1970, a maximum water absorption limit of 3 percent is permitted, provided tests in accordance with Sections 4.9 and 4.10 of this acceptance criteria are submitted. Underlayments qualified under ASTM D 1970 shall be limited to use with mechanically fastened roof coverings only. 4.0 TEST METHODS These test procedures are applicable only to underlayments evaluated under Section 3.1.2. 4.1 Tensile Strength Tests: Tests are to be conducted on a minimum of five machine-direction specimens and five cross-direction specimens in accordance with ASTM D 828 for paper-type products, ASTM D 1682 ASTM D 5034 and ASTM D 5035 for fabrictype products, ASTM D 412 for rubberized-type products and Section 7.3 of ASTM D 1970 for products that do not fall into any one of the three preceding product categories. Samples are 1 inch wide by 10 inches long (25.4 mm by 254 mm) for ASTM D 828, and 4 inches wide by 6 inches long (102 mm by 152 mm) for ASTM D 1682 ASTM D 5034 and ASTM D 5035. Sample size for rubber-type products shall comply with ASTM D 412, Method A, Die C. Sample size for products tested in accordance with ASTM D 1970 shall comply with Section 7.3.1 of ASTM D 1970. Conditions of Acceptance 1 SPECIFICATION REQUIREMENTS 2 ASTM D 828 or ASTM D Minimum 20 pounds per inch 412 width ASTM D 1682 D 5034 and Minimum 75 pounds per ASTM D 5035 specimen ASTM D 1970 Minimum 25 pounds per inch width For SI: 1 inch = 25.4 mm, 1 pound = 4.45 N. 1 Control, accelerated-aged and ultraviolet specimens shall satisfy minimum requirements. 2 Both machine and cross-direction specimens. 4.2 Water-vapor Transmission Test: 4.2.1 General: Tests are to be conducted in accordance with ASTM E 96, Procedure A. 4.2.2 Conditions of Acceptance: None. Results are to determine whether the product is a vapor barrier under the UBC. 4.2 4.3 Pliability: 4.2.1 4.3.1 General: Five 1-inch-wide-by-8-inchlong (25.4 mm by 203 mm) specimens are maintained at 14 ± 3.6 F ( 10 ± 2 C) for 24 hours and immediately bent over a 1 / 8-inch (3.2 mm) steel mandrel through a 90- degree angle. 4.2.2 4.3.2 Conditions of Acceptance: Specimens show no cracking or delamination. 4.3 4.4 Water-ponding Test: 3 4.3.1 4.4.1 General: Three control specimens and three aged specimens are prepared. A 2-inch-diameter (51 mm) cylindrical tube with a 24-inch (610 mm) height of distilled water is sealed onto the specimen surface for a period of 48 hours. The drop in the water column from the original 24-inch (610 mm) height is to be reported in hundredths of an inch. The presence of any moisture on specimens shall be reported. 4.3.2 4.4.2 Conditions of Acceptance: Maximum percolation of 1.0 percent of column height [0.24 inch (6.1 mm)]. Compensation for evaporation is permitted by comparison with identical apparatus mounted on a nonabsorbent surface. 4.4 4.5 Peel-adhesion Test: 4.4.1 4.5.1 General: Six test specimens are prepared in accordance with ASTM C 794 for each substrate desired. The specimens are conditioned at 73 ± 4 F (22.8 ± 2.2 C) and 50 ± 5 percent relative humidity for seven days. Peel strength tests are then conducted after a seven-day curing period (control), after a seven-day water immersion, after 210 hours of ultraviolet exposure and after a 25-day accelerated aging cycle. 4.4.2 4.5.2 Condition of Acceptance: Peel strength of conditioned specimens shall exceed 75 percent that of the control specimens. 4.5 4.6 Cycling and Elongation Test: 4.5.1 4.6.1 General: Three specimens are prepared with 1 / 2-inch-thick (12.7 mm), 3-inch-by-6-inch (76 mm by 152 mm) A-C plywood. Each specimen includes two plywood pieces aligned so that the 6-inch (152 mm) edges are separated by 1 / 8 inch (3.2 mm). The underlayment is attached to the plywood pieces across the joint and conditioned at 73 ± 4 F (22.8 ± 2.2 C) for seven days. After conditioning, specimens are placed in a cold box, which is maintained at 20 F ( 28.9 C) for seven days. Specimens are then cycled between a 1 / 8-inch (3.2 mm) and 1 / 4-inch (6.4 mm) plywood edge separation for 100 cycles while maintaining the temperature at 20 F ( 28.9 C). The rate of movement shall be 1 / 8 inch (3.2 mm) per hour. 4.6 4.7 Accelerated Aging: 4.6.1 4.7.1 General: Six specimens, 12 inches by 12 inches (305 mm by 305 mm) in size, are aged by the cyclic process described herein. Twenty-five cycles are required, with each cycle consisting of the following: 1. Oven drying at 120 F (48.9 C) for three hours with all surfaces exposed. 2. Immersion in water maintained at room temperature for three hours, with all surfaces exposed. 3. Removal from water and blotting dry before air-drying for 18 hours at room temperature with all surfaces exposed. Samples shall be in the air-dry period over weekends and holidays, which should be confirmed in the test log. The room temperature shall be maintained at 73 ± 5 F (22.8 ± 2.8 C). 4.6.2 4.7.2 Conditions of Acceptance: No visible damage to the specimens, such as cracking or chipping. Additionally, tests in accordance with Sections 3.1.2.1, 3.1.2.4 and 3.1.2.5 shall be conducted. Results shall show

PROPOSED REVISIONS TO THE ACCEPTENCE CRITERIA FOR ROOF UNDERLAYMENT FOR USE AS METAL VALLEY FLASHING UNDERLAYMENT IN SEVERE CLIMATE AREAS, OR AS AN ICE BARRIER no deterioration due to accelerated aging (except for peeladhesion tests, where results shall be as specified in Section 4.5). 4.7 4.8 Ultraviolet Exposure: 4.7.1 4.8.1 General: Exposure to ultraviolet sunlamps for 210 hours (10 hours per day for 21 days) in an enclosure in accordance with Figure 1. Two 18-inch-by- 48-inch (457 mm by 1219 mm) samples are required for this. Ultraviolet exposure shall be directed on the specimen surface that will be exposed to sunlight in normal application. Lamps and enclosure are to be adjusted so that the temperature on the sample is between 135 F and 140 F (57.2 C and 60 C). Sunlamp bulbs shall be General Electric Type H275 RUV (275 W) or equivalent bulbs providing UV characteristics of 5.0 W/m 2 /nm irradiance at a wavelength of 315 to 400 nm at one meter. 4.7.2 4.8.2 Conditions of Acceptance: No visible surface or structural changes such as peeling, chipping, cracking, flaking or pitting when observed under minimum five-power magnification. Additionally, ultraviolet-exposed specimens shall be subjected to tensile-strength and peeladhesion tests with conditions of acceptance as noted in Sections 4.1 and 4.5, respectively. 4.8 4.9 Temperature-cycling Tests: 4.8.1 4.9.1 General: This test applies to products tested under ASTM D 1970 having a water absorption value greater than 0.1 percent and less than 3 percent. A minimum of five representative samples shall be subjected to 25 consecutive cycles of this test, each cycle consisting of one hour of water exposure at room temperature followed by six hours at minus 40 F (-40 C), 2 hours at 70 F (21.1 C), 14 hours at 180 F (82 C), and 1 hour at 70 F (21.1 C); between cycles, such as on weekends and holidays, the samples may be maintained at 70 F (21.1 C). A plus 5 F (2.8 C) tolerance is allowed on these temperatures. The underlayment shall be applied to a rigid wood frame simulating the field installation procedure recommended by the manufacturer. Horizontal and vertical joints shall be included in the specimens. Spray nozzles for the water exposure shall be located approximately 7 feet (2134 mm) above the test decks, and shall deliver 6 inches (152 mm) of water per hour at a temperature of 40 F to 60 F (4.4 C to 15.6 C). The test decks shall be installed at the lowest slope recommended for field installation. At the conclusion of the 25 cycles, the specimens shall be examined under 5 magnifications. 4.8.2 4.9.2 Conditions of Acceptance: The product is considered to have passed this test if no crazing, cracking or other deleterious surface or joint changes are noted at the end of the test. Additionally, there shall be no sign of failure or distress at fastener locations and underlayment joints. 4.9 4.10 Water Percolation Test: 4.9.1 4.10.1 General: This test applies to products tested under ASTM D 1970 having a water absorption value greater than 0.1 percent and less than 3 percent. Percolation tests involve mounting a 1-inch-diameter (25.4 mm) (or larger) tube on the surface of at least three underlayment specimens. The tube is centered over the surface, and sealed. The tube is then filled with distilled water to a height of 48 inches (1219 mm). The water column is maintained at 75 F ± 5 F (23.8 C ± 2.8 C) at 50 percent ± 5 percent relative humidity for a period of 48 hours. The drop in water level is to be reported in hundredths of an inch. 4.9.2 4.10.2 Conditions of Acceptance: There shall be no accumulation of moisture on the underside of the specimen. A maximum water percolation equivalent to a 0.5-inch (12.7 mm) column height is permitted. 5.0 QUALITY CONTROL 5.1 The products shall be manufactured under an approved quality control program with inspections by an inspection agency accredited by the International Accreditation Service (IAS) or otherwise acceptable to ICC-ES. 5.2 A quality control manual Quality documentation complying with the ICC-ES Acceptance Criteria for Quality Control Manuals Documentation (AC10) shall be submitted. TABLE 1 REFERENCED STANDARDS STANDARD DATE OF STANDARD IBC IRC UBC ASTM D 1970 2001 2001 1990 4

PROPOSED REVISIONS TO THE ACCEPTENCE CRITERIA FOR ROOF UNDERLAYMENT FOR USE AS METAL VALLEY FLASHING UNDERLAYMENT IN SEVERE CLIMATE AREAS, OR AS AN ICE BARRIER For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. FIGURE 1 5