Environmental Products. Designed to Protect and Improve Our Environment. Delivering Reliability

Similar documents
Inlets & Catch Basins

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

16. Design of Pipeline Structures.

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid

401 Sanitary Sewer System Design Criteria. The following additional design requirements shall also apply:

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

400 Gal. Grease Interceptor


2.1.2 Minimum wall thickness shall be 90 mm Frames and covers shall be bitumen coated by dipping.

PERMANENT PAVEMENT REPAIR NO SCALE

University of Delaware

ZG Scope. 2 Applicable Documents. 3 General. 4 Stock Item Numbers. Padvault Single-Phase Residential, 2.1 PacifiCorp Material Specifications

Qualified Product Policy 15 Drainage Structure Miscellaneous Components Qualified Product List 14 [G] Heavy Duty Gray Cast Iron

Storm Drainage

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION XXXX POLYMER CONCRETE PUMP STATIONS

3/23/2016. Happy Pi Day! What We Will Discuss. Best Practices for Precast Concrete Tank Inspections

CONCRETE TECHNOLOGY CORPORATION

AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MANHOLES, CATCH BASINS, DITCH INLETS AND VALVE CHAMBERS

SECTION PRECAST CONCRETE MANHOLES

TYPE "A" CATCH BASIN

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II

Miscellaneous and Cast Iron Listings

WWR For Structural Applications A Discussion of Current Product Knowledge and Practices

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

Current Standard Plates including Transmittal Letters are available on the web at:

Appendix J: Structural Engineering

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

OVERALL STRUCTURAL SYSTEM

Section 10 Design Criteria: Components

PIPE CULVERTS. Construct pipe culverts, beveled ends, pipe aprons, and associated appurtenances.

PRECAST CONCRETE ON-SITE WASTEWATER TANKS

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings

SECTION GROUND WATER STORAGE TANKS

IAPMO Z yy. Rainwater Harvesting Tanks. 1 Scope. 2 Reference Publications

POST FRAME BUILDING STANDARDS

CHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION.

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

Hydrodynamic Separation Product Calculator

Section G1. Design of Cast-In-Place Box Conduits

VALLECITOS WATER DISTRICT SECTION PRECAST REINFORCED CONCRETE MANHOLES

Pre-Sloped Drain System

SECTION D2 MANHOLES AND CATCH BASINS GENERAL MATERIALS

Appendix J: Storm Conveyance Design Parameters

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

Facility Sanitary Sewers

Selection, installation and USage of HatcHeS

SECTION STORM DRAINAGE SYSTEM Excavating, Backfilling, and Compaction for Utilities Cast-in-place Concrete.

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.


SECTION PUBLIC WATER SERVICE CONNECTIONS

Use of Grade 80 Reinforcement in Oregon

GENERAL UTILITIES REQUIREMENTS

Summary of the 2011 Changes

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M

***************************************************************************************************************

SECTION UTILITY MANHOLES AND STRUCTURES

Chapter 5 Hydraulic Structures

PART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

SECTION STORM DRAINAGE


SECTION SANITARY WASTE INTERCEPTORS

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

SECTION ELECTRICAL UTILITY SERVICES

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Structural Technical Report 1 Structural Concepts/ Structural Existing Conditions Report

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

How Loads Are Distributed

APPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes

A 2" MICHIGAN DEPARTMENT OF TRANSPORTATION. 1" (Min.) \ Bracket to \ bottom chord. 24-3" (Max.) 45 (Typ.) * W40 x 149. or l5 x 5 x 1/2 (see

DESIGNING AND CONSTRUCTION OF T-WALL RETAINING WALL SYSTEM

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

TECHNICAL SPECIFICATIONS KNOX MCRAE BAFFLE BOX

SECTION PRECAST CONCRETE MANHOLES

Section [ ] Storm Water Treatment Device

MagnumStone Specifications Gravity

TECHNICAL REPORT 1. Structural Concepts / Structural Existing Conditions. Penn State Hershey Medical Center Children s Hospital. Hershey, Pennsylvania

ULTRA FLO Storm Sewer Pipe

Special Specification 6186 Intelligent Transportation System (ITS) Ground Box

A. This Section includes gravity-flow, nonpressure storm drainage outside the building, with the following components:

SECTION PRECAST CONCRETE BIOSOLIDS STORAGE TANK

Lifetime Guaranteed Construction with unique built-in installation and maintenance features

(SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No.


Pulaski County, Virginia

HIGH RISE CONDO SOHO, NEW YORK, NY

MultiDrain Systems, Inc. #12 EconoDrain and EconoDrain PT-3 Hydraulic Data. We drain your site, not your budget!

HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED

BAYFILTER SPECIFICATIONS

New Jersey Turnpike Authority

MultiDrain Systems, Inc. #8 EconoDrain and EconoDrain PT-3 Hydraulic Data. We drain your site, not your budget!

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Transcription:

Delivering Reliability A Designed to Protect and Improve Our Environment Environmental Products Sales & Service 888-9Oldcastle (888-965-3227)

A Environmentally Responsible COVER & FRAME Oldcastle Precast to the Rescue All of our products are produced in a controlled environment helping us maintain the high standards implemented by Oldcastle Precast. Many of our products are specifically designed to protect and improve the environment. We re always looking for new ways to minimize waste, increase recycling, improve energy management and use eco-friendly materials. FINISH:Hot Dip Galvanized after Fabrication. FRAME:Can be Fabricated for Cast-In Applications. LOADING:Designed for H20 loading for Non Roadway Applications. DOORS: Offered in Single, Double, or Triple Configurations, open 180 Degrees. EMBEDDED LIFTERS MATERIAL:Carbon Steel LOADING:Offered in 2, 4, 8, & 20 Ton 1 Ton Universal Lifters also available. Material and Design Loads The structural notes below are for standard models. We can design vaults to meet other specifications. 1. Concrete 5000psi (35 Mpa) @ 28 days. 2. Rebar ASTM A 615 grade 60 rebar. 3. Mesh Welded Wire Fabric ASTM A185 grade 65 4. Design Building Code Requirements for Reinforced Concrete (ACI 318-99) including all referenced standards and specifications. AASHTO Standard Specifications for Highway Bridges - 16th edition. 5. Loads Dead Load: Concrete - 150 PCF Earth Cover - 120 PCF Lateral Earth Pressure on walls: Equivalent Fluid pressure above water table + 39.6 PSF per foot of depth. Equivalent Fluid pressure below water table + 81.4 PSF per foot of depth. Surcharge on walls + 2 feet of earth cover Live Load: AASHTO HS20-44 32,000 lbs. rear axle loading GRADE RINGS / RISERS FINISH:Concrete with various Coatings/Textures. Designed to bring Covers up to Grade. Can be Rectangular or Round. Suitable for Off-Street Traffic. INLET PIPE Supplied by others SLUDGE WEIR Weight Varies by size FACET M-PAC Coalescing Media Shown with (3) rows We can provide drawings and calculations stamped by a Professional Engineer.

Environmental Vaults Sales & Service 888-965-3227 SINGLE GREASE INTERCEPT Can be Fabricated in a variety of Sizes. MANHOLE COVER & FRAME MATERIAL:Cast or Ductile Iron. DESIGNS:Custom Lettering & Design available. LOADING:Built to an H20 rating up to 150 KIP. SIZES: 24, 30, 32, 36 Round OIL WEIR Weight Varies by Size OUTLET PIPE Supplied by Others Size Varies by vault type OUTLET WEIR Weight Varies by size

Oil/Water Separator Vault Oil & Water Separator Vaults We offer a wide range of oil & water separator vaults to meet the specific application needs of our customers. From smaller capacity 35 GPM (gallon per minute) vaults, to larger capacity 800 GPM vaults and everything in between.

Sales & Service 888-965-3227 Grease Interceptor Vault Single Grease Interceptor Vault We offer grease interceptors that can be desinged and configured to meet a wide range of commercial applications as well as soecific performance criteria. LID SECTION ACCESS OPENING-Can be any size and location. INVERTED RING & COVER as well as STEEL or ALUMINUM HATCHES can also be cast in. DESIGNED FOR AASHTO HS-20 LOADING BASE SECTION SPECIAL ACCESSES, CASTOUTS, KNOCKOUTS, ETC. can be placed as specified. DESIGNED FOR AASHTO HS-20 LOADING DESIGNED ACCORDING TO ASTM C857-87 AND ASTM C858-83s. *Grease Interceptor vaults are available in a variety of standard and custom sizes to suit virtually any application.

Sand/Oil Interceptor Vault Sand & Oil interceptor Vault We offer a wide range of sand & oil interceptor vaults to meet the specific application needs of our customers. From smaller 320 gallon capacity vaults, to larger 11000 GPM capacity vaults and everything in between. LID SECTION ACCESS OPENING-Can be any size and location. INVERTED RING & COVER as well as STEEL or ALUMINUM HATCHES can also be cast in. DESIGNED FOR AASHTO HS-20 LOADING Retaining Baffle for Sand Interceptor BASE SECTION SPECIAL ACCESSES, CASTOUTS, KNOCKOUTS, ETC. can be placed as specified. DESIGNED FOR AASHTO HS-20 LOADING DESIGNED ACCORDING TO ASTM C857-87 AND ASTM C858-83s. *Sand & Oil vaults are available in a variety of standard and custom sizes to suit virtually any application.

Sales & Service 888-965-3227 Interceptor Vaults Standard Sizes for Interceptor Vaults We offer a wide range of standard sized interceptor vaults to meet the specific application needs of our customers. From smaller capacity 320 Gallon vaults, to larger capacity 11,000 Gallon vaults and everything in between. Elevation Plan STANDARD INTERCEPTOR VAULTS Gallon Capacity MODEL A B C D E F WEIGHT 320 463-SI 4-0 6-0 2-0 2-2 3-0 1-4 7,535 LBS 500 4113-SI 4-0 11-0 2-0 2-2 3-0 1-4 11,631 LBS 750 4114-SI 4-0 11-0 2-6 2-8 4-0 1-8 14,031 LBS 1000 41145-SI 4-0 11-0 3-3 3-5 4-6 2-2 16,231 LBS 1250 4115-SI 4-0 11-0 4-0 4-2 5-0 2-8 16,431 LBS 1500 4116-SI 4-0 11-0 5-0 5-2 6-0 3-4 18,831 LBS 1800 41165-SI 4-0 11-0 5-6 5-8 6-6 3-8 20,031 LBS 2000 4117-SI 4-0 11-0 6-0 6-2 7-0 4-0 21,231 LBS 2500 61266-SI 6-0 12-6 4-6 4-8 6-0 3-8 24,529 LBS 3000 61267-SI 6-0 12-6 5-6 5-8 7-0 2-6 27,454 LBS 3500 11125-SI 11-0 12-0 3-8 3-10 5-0 2-6 29,521 LBS 5000 11175-SI 11-0 17-0 3-8 3-10 5-0 2-8 37,702 LBS 5500 11176-SI 11-0 17-0 4-0 4-2 5-9 2-8 40,964 LBS 6000 11195-SI 11-0 19-0 4-0 4-2 5-9 2-8 44,462 LBS 7000 11225-SI 11-0 22-0 4-0 4-2 5-0 2-8 45,883 LBS 8000 11226-SI 11-0 22-0 4-6 4-8 5-9 3-0 49,708 LBS 9000 11276-SI 11-0 27-0 4-0 4-2 5-9 2-8 58,451 LBS 10000 11296-SI 11-0 29-0 4-6 4-8 5-9 3-0 61,949 LBS 11000 11348-SI 11-0 34-0 4-0 4-2 5-9 2-8 70,692 LBS

Environmental Delivering Reliability A Oldcastle Precast Oldcastle Precast is the leading manufacturer of precast concrete, polymer concrete, and plastic products in the United States. With a nationwide network of facilities, our products are always close at hand. Our employees are committed to upholding core values of reliability, quality, and service in revolutionary ways. Our attention to detail exceeds the expectations of customers from some of the largest companies in the U.S., across a spectrum of industries. Sales & Service 888-9 Oldcastle (888-965-3227) 2010 Oldcastle Precast, Inc. V1_121409