Laboratory water purification systems

Similar documents
adrona Crystal E series Crystal E Ultrapure Crystal E HPLC Crystal E Bio Crystal E Pure Water purification systems

Purite Water Purification Systems

Water Purification System

Pure and ultrapure laboratory water from a single system

Thermo Scientific Barnstead LabTower EDI water purification system

PURELAB Chorus. Solutions for Type I Ultrapure Water

TKA LabTower EDI. Two in one! Pure and Ultrapure water WATER PURIFICATION SYSTEMS

The Laboratory. Quick Reference Product Guide

Synergy Water Purification Systems

The Laboratory Water SpecialiSTS. Quick Reference Product Guide

PURELAB Chorus. Solutions for Type I Ultrapure Water

PURELAB CHORUS SYSTEMS

Protegra CS RO Series. Meeting All Your Pure Water Demands. Water Technologies

Direct Water purification system Pure & ultrapure water directly from tap water

L A B W A T E R ULTRA-PURE WATER. PURELAB TM Maxima. Ultra-Pure Water Purification Systems. The Laboratory Water Specialists

The Laboratory. Quick Reference Product Guide

CENTRALIZED SYSTEMS CENTRA. Packaged central laboratory water systems. The Laboratory Water Specialists

Milli-Q Integral system

THE LABORATORY WATER SPECIALISTS. Quick Reference Product Guide WATER TECHNOLOGIES

Milli-Q Reference Water Purification System

Advantage System Elix The Best in Pure Water

L A B W A T E R ULTRA-PURE WATER. PURELAB Ultra. Ultra-Pure Water Polishing System. The Laboratory Water Specialists

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

LABORATORY WATER SYSTEMS

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

rios Water Purification system The standard for laboratory-grade water

TKA Pacific UP/UPW. High purity water systems for every laboratory

AQUINITY 2 & ASTACUS 2 INNOVATIVE ULTRA PURE WATER SYSTEMS

Laboratory Water Three water qualities One clear solution

CENTRALIZED SYSTEMS CENTRA. Packaged central laboratory water systems. The Laboratory Water Specialists

PRIMARY GRADE WATER. PURELAB Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

Milli-Q Direct Water Purification System

PURELAB Chorus 2 Innovation and Flexibility

Elix Advantage System

PURELAB Innovation and Flexibility

PRIMARY GRADE WATER L A B W A T E R. PURELAB TM Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

Elix Gulfstream Clinical Water Purification System

Water purification solutions

Clean for sure! TKA GenPure.

AFS 8D / 16D Degassed Water Purification Systems

ULTRA-PURE WATER PURELAB TM UHQ. Ultra-Pure Water Purification Systems. The Laboratory Water Specialists

PURELAB. Laboratory water purification systems

PURELAB. Laboratory water purification systems

1 water system can drive

RiOs-DI Water Purification Systems

Water Purification System

RiOs-DI Water Purification Systems

Laboratory Water Purification Products

Ultra pure water, 18,2 M cm. TKA GenPure. For Life Sciences, Analyses and Laboratory applications WATER PURIFICATION SYSTEMS

Elix Advantage Water Purification Systems. The best in pure water at your fingertips

RiOs Essential 5, 8, 16, 24 Water Purification Systems

Laboratory Water Purification Systems

arium pro Ultrapure Water Systems

TKA MaxiTower plus. Pure water State-of-the-art Technology. WATER PURIFICATION SYSTEMS

PURELAB. Laboratory water purification systems

Ultra Clear RO and Ultra Clear Compact Series Systems

AQUINITY 2 & ASTACUS 2 INNOVATIVE ULTRA PURE WATER SYSTEMS

arium mini Ultrapure Water System

arium mini Ultrapure Water System

PURELAB CHORUS SYSTEMS

PURIFIED WATER DESIGN

PURELAB. Laboratory water purification systems. Page 3 of 46

ANALYZER WATER SYSTEMS MEDICA. Water purification systems for clinical analyzers. Pure Water, Pure Science, Pure Service

PURELAB Chorus. Laboratory Water Purification Solutions In Tune With Your Needs

Milli-Q Advantage A10 Water Purification Systems. User-adapted ultrapure water

PURELAB Chorus. Laboratory Water Purification Solutions In Tune With Your Needs

ORDERING INFORMATION AFRICA AUSTRALIA (02) AUSTRIA BALTIC COUNTRIES BELGIUM

MEDIUM WATER PURIFICATION SYSTEM

ANALYZER WATER SYSTEMS MEDICA. Water purification systems for clinical analyzers. Pure Water, Pure Science, Pure Service

RiOs-DI Water Purification Systems

Standard Specification for Reagent Water 1

water purification system

LABORATORY WATER SYSTEMS

REACTION TANKS PURELAB CHORUS LABORATORY WATER PURIFICATION SOLUTIONS IN TUNE WITH YOUR NEEDS

Product appearance and specifications are subject to change without prior notice due to continuing product improvement.

R&D Quality Our manufacturing and distribution site is ISO 9001 v certified and ISO certified.

RiOs 3, 5, 8 Water Purification Systems

Elix Advantage Water Purification Systems. The best in pure water at your fingertips

Wolf Laboratories Limited

ABOUT US. Company Profile. Products Series. Utilizing global high-quality parts. Incorporating cutting-edge technology

RiOs 3, 5, 8 Water Purification Systems

Thermo Scientific Barnstead Nanopure Ultrapure Water Systems. Pure water. Pure research. Total confidence. Part of Thermo Fisher Scientific

More than 10 years in Ultrapure Water System Manufacture, we are going with you in your high water quality demand better understanding in service

Draft for comments only Not to be cited as East African Standard

RiOs 3, 5, 8 Water Purification Systems

REACTION TANKS CENTRA CENTRALIZED LABORATORY WATER SYSTEMS

Systems. Barnstead MIX AND MATCH...WITH BARNSTEAD YOU HAVE A CHOICE

arium pro Ultrapure Water Systems

CENTRA. Centralized laboratory water systems

Type I. Features and Benefits 18+ Megohm-cm Type I reagent grade water. AQUA SOLUTIONS Type I. Reagent Grade DI Systems

Preparation of Reagent Water

CENTRA. Centralized laboratory water systems

DRINKING WATER CONDITIONERS WATER PURIFIERS U.V. STERILIZERS REVERSE OSMOSIS GELPUR FILTER 113 GELPUR FILTER SI 113 GELPUR SL

Ultra pure water, 18,2 MΩ cm. TKA GenPure. For Life Sciences, Analyses and Laboratory applications WATER PURIFICATION SYSTEMS

5000TOCi with ISM. Fast, Continuous and Reliable Total Organic Carbon Measurement

Importance of pure water in modern ion chromatography

IONPURE CONTINUOUS ELECTRODEIONIZATION (CEDI)

W A T E R P U R I F I C A T I O N S Y S T E M S

Blank Optimization Using Ultrapure Water Suitable for Trace Ion Analysis.

Milli-Q IQ Purification System. An ultrapure water solution designed with YOU in mind

Transcription:

Laboratory water purification systems

WATER PURIFICATION SYSTEMS Adrona water purification systems provide ultrapure (Grade 1), pure (Grade 2) and reverse osmosis (RO Grade 3) water for laboratory needs. The quality of water meets the requirements of ISO 3696 standard and corresponding ASTM and CLSI standards. Tap water systems Water type systems Water type B30 Ultrapure/pure Onsite + Ultrapure Integrity + Ultrapure Connect Ultrapure E30 Ultrapure/pure Crystal EX Ultrapure/pure/RO 1 Crystal Clinic Crystal Sterifeed Crystal 7 Pure Pure Pure/RO 1 depending on model, water purification systems can produce ultrapure and pure water or RO and pure water CONFIGURATIONS ACCORDING TO APPLICATIONS Each Adrona model is available in various configurations according to the customer needs Applications RO Pure EDI Trace HPLC Bio Glassware rinsing Laboratory washers Autoclaves General Electrochemistry laboratory applications Wet chemistry Spectrophotometry Buffer and media preparation Reagent preparation Inorganic analysis methods Organic analysis methodes Molecular Biology Flame atomic absorption spectrophotometry Graphite automizer atomic absorption spectrophotometry Plasma massspectrometry (ICP MS) Plasma spectrophotometry (ICP OES) Ion chromatography Liquid chromatography (HPLC/ UHPLC) Gas chromatography Total organic carbon measurments cytometry Cell and tissue culture Molecular biology 2

FEATURES The systems are installable by user and all cartridges and s are user replaceable. No tools are needed. The first set of the consumables is included into the delivery. Adrona water purification systems can be installed either on a laboratory bench or on a wall 1. Wallmount installation provides the saving of valuable laboratory space. VOLUMETRIC DISPENSE Adrona water purification systems 2 have a volumetric r, which enables the user to set accurate dispensing volume for each cycle. The volume can be set either from the keyboard or by using teaching mode. In teaching mode user uses Dispense On/OFF button to do the first cycle manually.afterwards, the system will exactly the same volume each time the user presses the button again. WATER QUALITY AND VALIDATION Embedded recirculation loop ensures stable premium water quality and enables practical elimination of Total Organic Carbon (TOC). Performance of the deionization and polishing s is constantly monitored. Monitoring algorithm enables cutting running costs, as replacement of the s is requested only when service life is close to the end. Stability of water quality guaranteed by double Ion Exchange cartridge system. (Adrona systems have 2 Ion Exchange cartridges (deionization and polishing) therefore excellent water quality guaranteed even if one of them is waiting for replacement at the moment). User can carry out the validation of water quality s right on the site (available on B30, Integrity+, Connect and Onsite+). It is possible to validate conductivity measuring circuits to check if they are operating properly. Validation kit for OQ is available as an option. This helps the customer to validate water quality measuring circuits on periodical basis. No visit of service engineer is required. TOTAL ORGANIC CARBON (TOC) MONITOR Organic contaminants may not have effect on conductivity of water, so conductivity s cannot be used for TOC monitoring. Therefore, a special TOC monitoring is needed to measure TOC level. Several models of Adrona water purification systems have the TOC monitor feature. TOC values are shown on display. DISPLAYS Provides clear water quality readout and information about the system status including current resistivity and remaining pre service life. MONOCHROME HIGH RESOLUTION LCD DISPLAY COLOR GRAPHIC LCD DISPLAY The 16bit color display provides clear readout of water quality, system component status, performance of the polishing. System component status is reflected on the display in an intuitive color pattern (Green/Yellow/ Red). System flowchart shows all component status and water quality parameters at a glance. Image can vary depending on model and its configuration. ELECTRODEIONIZATION MODULE For the laboratories with the high water consumption Adrona offers electrodeionization that is an option. It allows significantly reduce the running costs of water purification system due to fact the replacement of EDI is not required anymore. SAFETY All the Adrona water purification systems have all necessary safety functions. They are tested by an independent and accredited company for compliance with the CE directives related to safety and electromagnetic compatibility. WARRANTY AND AFTERSALES SUPPORT Adrona provides 2 year warranty and continuous technical support. Adrona support is evaluated very positively by dealers worldwide. CERTIFICATION Adrona design, manufacturing, sales and service is ISO 9001:2009 certified to provide the highest quality in every aspect. 1 If not specified otherwise 2 Depends on model and configuration 3

B30 AND INTEGRITY+ The highend B30 and Integrity+ series water purification systems produce ultrapure and pure water for laboratory needs They are designed for maximum convenience of use and have maximum features. B30 model is equipped with external with capacity of 25L, larger capacities up to 60L (up to 300L for B30 EDI) are available as an option. Integrity+ series systems contain a 5L embedded to keep the system compact. D E S C R I P T I O N B30 Trace B30 HPLC B30 Bio B30 EDI Water type ultrapure water (Grade 1) ultrapure water (Grade 1) pure water (Grade 2) pure water (Grade 2) ultrapure water (Grade 1) pure water (Grade 2) pure water (Grade 2) Application atomic absorption highly sensitive molecular water for general spectrometry chromatography biology laboratory applications plasma optical emission mass spectrometry cell culture and inorganic analytical spectrometry microbiology other methods sensitive methods other inorganic trace molecular biology to RNase and endotoxins recommended for labs analysis biology applications with high pure water consumption Display colour graphic LCD display Water quality TOC Monitor option option Measurment validation port Volumetric Connection possibility to water dispensing unit Basic 25L included, possibility to upgrade to Pro, other s optional Not included Installation installable either on a laboratory bench or on a wall D E S C R I P T I O N Integrity+ Trace Integrity+ HPLC Integrity+ Bio Water type ultrapure water (Grade 1) ultrapure water (Grade 1) ultrapure water (Grade 1) Application atomic absorption spectrometry plasma optical emission spectrometry chromatography mass spectrometry microbiology highly sensitive biology applications other inorganic trace analysis molecular biology Display Color graphic LCD display Conductivity TOC Monitor option Measurment validation port Volumetric dispensing Connection possibility to water dispensing unit embedded 5L Installation installable either on a laboratory bench or on a wall 4

O R D E R I N G I N F O R M A T I O N Model B30 Trace B30 HPLC B30 Bio B30 EDI Integrity+ Trace Integrity+ HPLC Integrity+ Bio Water quality validation kit Electrodeionization (for B30) Software compliant to GLP & CFR 21 CONSUMABLES number CB2301 CB2303 CB2305 CB301018 CB2101 CB2103 CB2105 10913 410107 410162 SPECIFICATIONS io n s B30/Integrity+ system configuration Purified water Trace HPLC Bio EDI Grade 1 water resistivity 18.2 MΩ x cm 18.2 MΩ x cm 18.2 MΩ x cm Grade 1 water conductivity 0.055 μs/cm 0.055 μs/cm 0.055 μs/cm Grade 2 water resistivity 10 MΩ x cm 10 MΩ x cm 10 MΩ x cm 10 MΩ x cm Grade 2 water conductivity 0.1 μs/cm 0.1 μs/cm 0.1 μs/cm 0.1 μs/cm Total Organic Carbon (TOC) level <10 ppb <2 ppb <2 ppb <30 ppb RNase <0.01 ng/ml DNase <4 pg/μl Bacteria < 1 CFU/mL < 1 CFU/mL < 1 CFU /ml Endotoxins <0.15 EU /ml <0.15 EU /ml < 0.001 EU /ml icles >0.22 μm <1/mL <1/mL <1/mL Deionization life* 1 m 3 1 m 3 1 m 3 N/A Dimensions (WxDxH), cm 32x54x60 32x54x60 32x54x60 32x54x60 Feed water pressure * B30 ** Integrity+ 0,5 4 bar* 2 6 bar** 0,5 4 bar* 2 6 bar** 0,5 4 bar* 2 6 bar** 0,5 4 bar* number Description Replacement criteria Comments 10310 Deionization When indicated on the display or water conductivity is constantly > 0.1 μs/cm during filling stage 10029 When indicated on the display or water conductivity is constantly > 0.1 μs/cm during recirculation 10319 Pre set Every 6 months or when pres are clogged 10018 UV photooxidation bulb 23 years on average Only for Bio and HPLC 10012 Pointofuse micro Every 6 12 months Only for Trace and HPLC 10120 Pointofuse ultra Every 6 12 months Only for Bio 10011 UV sterilization bulb When required (on average every 3 years) Only for Bio FLOW DIAGRAM Pre Pre RO membrane Deionization Check Grade 2 water Grade 2 25 L Pump Grade 1 Dispense meter Point of use micro B30 TRACE 5

Pre Pre RO membrane Deionization Check Sterilization (Bio configuration only) Grade 2 water Grade 2 25 L Pump Check TOC Photooxidation Grade 1 Dispense meter Point of use micro (HPLC configuration) Point of use ultra (Bio configuration) B30 HPLC/BIO RO membrane Grade 2 Electrodeionization Pre Pre Check Grade 2 water (option) B30 EDI RO membrane Grade 3 Dispense meter Check Pump Grade 1 Point of use micro Pre Pre Integrated storage 5 L INTEGRITY+ TRACE RO membrane Grade 3 Dispense meter Pre Pre Check Integrated storage 5 L Pump Check TOC Grade 1 Point of use micro (HPLC configuration) Point of use ultra (Bio configuration) Photooxidation INTEGRITY+ HPLC/BIO 6

E30 E30 water purification system produce ultrapure and pure water for laboratory needs. It is designed for maximum convenience of use and have maximum features. This system is with optimal price/ performance ratio. O R D E R I N G I N F O R M A T I O N Model number E30 Trace CE301001 E30 HPLC CE301101 E30 Bio CE301201 D E S C R I P T I O N E30 Trace E30 HPLC E30 Bio Water type ultrapure water (Grade 1) pure water (Grade 2) ultrapure water (Grade 1) pure water (Grade 2) ultrapure water (Grade 1) pure water (Grade 2) Application atomic absorption spectrometry plasma optical emission spectrometry chromatography mass spectrometry microbiology highly sensitive biology applications other inorganic trace analysis molecular biology Display Color LCD display Conductivity TOC Monitor Measurment validation port Volumetric dispensing Connection possibility to water dispensing unit Basic 25L included, other s optional Installation installable on a laboratory bench SPECIFICATIONS Purified water specifications E30 E30 E30 Trace HPLC Bio Grade 1 water resistivity 18.2 MΩ x cm 18.2 MΩ x cm 18.2 MΩ x cm Grade 1 water conductivity 0.055 μs/cm 0.055 μs/cm 0.055 μs/cm Grade 2 water resistivity >10 MΩ x cm >10 MΩ x cm >10 MΩ x cm Grade 2 water conductivity <0.1 μs/cm <0.1 μs/cm <0.1 μs/cm Total Organic Carbon (TOC) level 5 10 ppb <2 ppb <2 ppb RNase N/A N/A <0.01 ng/ml DNase N/A N/A <4 pg/μl Bacteria < 1 CFU/mL < 1 CFU/mL < 1 CFU/mL Endotoxins <0.15 EU/mL <0.15 EU/mL < 0.001 EU/mL icles >0.22 μm <1 per ml <1 per ml <1 per ml Nominal flow, pure water (to storage ) 10 L/h 10 L/h 10 L/h Nominal flow, pure water 4 L/min 4 L/min 4 L/min Deionization life (standard ) 1 m 3 1 m 3 1 m 3 Recovery >30 % >30 % >30 % Dimensions (WxDxH), cm 40x35x55 40x35x55 40x35x55 Feed water pressure 0,5 4 bar 0,5 4 bar 0,5 4 bar Feed water conductivity < 900 μs/cm < 900 μs/cm < 900 μs/cm 7

CONSUMABLES number Description Replacement criteria Comments 10320 Replacement pre, E30 Filter life counter is zero or the is clogged 10310 Replacement deionization DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm 10029 Replacement polishing Every 12 years, depending on operation 10011 Replacement sterilization UV bulb As required (on average every 3 years) Bio systems only 10018 Replacement photooxidation UV bulb 23 years on average 10012 Replacement 0.22 μm micro Every 6 12 months HPLC and Bio systems only Trace and HPLC systems 10120 Replacement ultra Every 6 12 months Bio systems only FLOW DIAGRAMS Pre RO membrane Deionization Check Grade 2 water Grade 2 25 L Pump Grade 1 Dispense meter Point of use micro E30 TRACE Pre RO membrane Deionization Check Sterilization (Bio configuration only) Grade 2 water Grade 2 25 L Pump Check TOC Photooxidation Grade 1 Dispense meter Point of use micro (HPLC configuration) Point of use ultra (Bio configuration) E30 HPLC/BIO 8

CRYSTAL EX Adrona Crystal EX produces ultrapure and pure water. This multipurpose water purification system is highly appreciated due to the very affordable price. O R D E R I N G I N F O R M A T I O N Model number Crystal EX Trace EX1001 Crystal EX HPLC EX1101 Crystal EX Bio EX1201 Electrodeionization 410107 TOC monitoring 10106 D E S C R I P T I O N EX SERIES Water type Application Display Trace HPLC Bio ultrapure water (Grade 1) pure water (Grade 2) atomic absorption spectrometry plasma optical emission spectrometry other inorganic trace analysis ultrapure water (Grade 1) pure water (Grade 2) chromatography mass spectrometry microbiology molecular biology Monochrome LCD display ultrapure water (Grade 1) pure water (Grade 2) highly sensitive biology applications Conductivity TOC Monitor option option option Measurment validation port Volumetric dispensing Connection possibility to water dispensing unit Installation No No No Basic 25L included, possibility to upgrade to Pro, other s optional installable on a laboratory bench 9

SPECIFICATIONS Purified water specifications Crystal EX Trace Crystal EX HPLC Crystal EX Bio Grade 1 water resistivity 18.2 MΩ x cm 18.2 MΩ x cm 18.2 MΩ x cm Grade 1 water conductivity 0.055 μs/cm 0.055 μs/cm 0.055 μs/cm Grade 2 water resistivity >10 MΩ x cm >10 MΩ x cm >10 MΩ x cm Grade 2 water conductivity <0.1 μs/cm <0.1 μs/cm <0.1 μs/cm Total Organic Carbon (TOC) level 5 10 ppb <2 ppb <2 ppb RNase N/A N/A <0.01 ng/ml DNase N/A N/A <4 pg/μl Bacteria < 1 CFU/mL < 1 CFU/mL < 1 CFU/mL Endotoxins <0.15 EU/mL <0.15 EU/mL < 0.001 EU/mL icles >0.22 μm <1 per ml <1 per ml <1 per ml Nominal flow, pure water (to storage ) 10 L/h 10 L/h 10 L/h Nominal flow, pure water 4 L/min 4 L/min 4 L/min Deionization life (standard ) 1 m 3 1 m 3 1 m 3 Deionization life (high capacity ) 3 m 3 3 m 3 3 m 3 Recovery >30 % >30 % >30 % Dimensions (WxDxH), cm 40x35x55 40x35x55 40x35x55 Feed water pressure 1 4 bar 1 4 bar 1 4 bar Feed water conductivity < 900 μs/cm < 900 μs/cm < 900 μs/cm CONSUMABLES number Description Replacement criteria Comments 10320 Replacement pre, Crystal EX Filter life counter is zero or the is clogged 10310 Replacement deionization DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm 10029 Replacement polishing Every 12 years, depending on operation 10011 Replacement sterilization UV bulb As required (on average every 3 years) Bio systems only 10018 Replacement photooxidation UV bulb 23 years on average 10012 Replacement 0.22 μm micro Every 6 12 months HPLC and Bio systems only Trace and HPLC systems 10120 Replacement ultra Every 6 12 months Bio systems only 10

FLOW DIAGRAMS Reverse osmosis (RO ) Deionization quality Shunting Ultrapure water Final point of use Check Ultrapure water Activated carbon/5um pre Ultrapure water quality Pure (Grade 2) water CRYSTAL EX TRACE Reverse osmosis (RO ) Deionization quality Shunting Ultrapure water Final point of use Check Ultrapure water Activated carbon/5um pre Pure (Grade 2) water Dual wavelength UV photooxidation (185/254 nm) Ultrapure water quality CRYSTAL EX HPLC Reverse osmosis (RO ) Check Deionization UV sterilization (254 nm) quality Shunting Ultrapure water Ultrapure water Final point of use Activated carbon/5μm pre Pure (Grade 2) water Dual wavelength UV photooxidation (185/254 nm) Ultrapure water quality CRYSTAL EX BIO 11

CRYSTAL EX PURE CRYSTAL EX DOUBLE FLOW CRYSTAL EX RO Crystal EX RO and Pure systems produce pure (Grade 2) and RO (Grade 3) water. Pure and RO water comply with the requirements of a variety of applications, including: many inorganic methods of analysis (e. g. flame spectrophotometry); wet chemistry methods; electrochemistry; labware washing, etc. The water purification system Crystal Double is specially designed for the laboratories and applications with high water consumption (30 L/day and more). The system includes a high capacity (8L) deionization, that provides a reduction of system running costs. It is also possible to order 8L option (P/N 10101) for the Crystal EX Pure system. D E S C R I P T I O N Crystal EX RO Crystal EX Pure Crystal EX Double Water type RO water (Grade 3) pure water (Grade 2) pure water (Grade 2) Application Display wet chemistry methods labware washing steam sterilizers flame spectrophotometry inorganic analytical methods electrochemistry buffer preparation Monochrome LCD display flame spectrophotometry inorganic analytical methods electrochemistry buffer preparation Conductivity TOC Monitor Measurement validation port Volumetric dispensing Connection to water dispensing unit Installation No No No Not included installable on a laboratory bench O R D E R I N G I N F O R M A T I O N Model number Crystal EX RO EX1245 Crystal EX Pure EX1005 Crystal EX Double EX201001HC Electrodeionization 410107 High capacity deionization 10101 12

SPECIFICATIONS Purified water specifications Crystal EX RO Crystal EX Pure Crystal EX Double Purified water resistivity >10 MΩ x cm >10 MΩ x cm Purified water conductivity TDS rejection rate >98% <0.1 μs/cm <0.1 μs/cm icles >0.22 μm <1 per ml <1 per ml <1 per ml Nominal flow, pure water (to storage ) 10 L/h 10 L/h 10 L/h Dispense flow, pure water 4 L/min 4 L/min 4 L/min Deionization life (standard ) N/A 1 m 3 N/A Deionization life (high capacity ) N/A 3 m 3 (optional) 3 m 3 Recovery >30 % >30 % >30 % Dimensions (WxDxH), cm 40x35x55 40x35x55 40x50x55 Feed water pressure 1 4 bar 1 4 bar 1 4 bar Feed water conductivity < 900 μs/cm < 900 μs/cm < 900 μs/cm CONSUMABLES number Description Replacement criteria Comments 10320 Replacement pre, Crystal EX RO, Pure Filter life counter is zero or the is clogged 10039 Replacement pre set, Crystal EX Double 10310 Replacement deionization 10113 Replacement highcapacity deionization Filter life counter is zero or the is clogged DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm 10011 Replacement sterilization UV bulb As required (on average every 3 years) 10012 Replacement 0.22 μm Every 6 12 months Pure systems only Only EX Double or systems with 10101 option Only systems with 10102 option Only systems with 10201 option 13

FLOW DIAGRAMS Reverse osmosis (RO ) quality Check Activated carbon/5um pre Pure (Grade 2) water CRYSTAL EX RO Reverse osmosis (RO ) Deionization quality Check Activated carbon/5um pre Pure (Grade 2) water CRYSTAL EX PURE Activated carbon/5um pre Reverse osmosis (RO ) Deionization quality Check Activated carbon/5um pre Pure (Grade 2) water CRYSTAL EX DOUBLE FLOW 14

CRYSTAl CLINIC The Crystal Clinic water purification system is designed to provide purified water for smooth and reliable operation of automated biochemistry analyzers. Crystal Clinic has two reverse osmosis s and high capacity deionization cartridge (DI). Large DI cartridge volume significantly reduces running costs. Crystal Clinic has two water quality s. The first controls quality of water filling the storage that is shown on the display while the is beeing filled. The second controls quality of water supplied to a biochemical analyzer. D E S C R I P T I O N Water type pure water (Grade 2) Application Display Conductivity TOC Monitor Measurement validation port Volumetric dispensing Connection to water dispensing unit Installation purified water for automated biochemistry analyzers monochrome LCD display pressurized storage, 100 L installable on a laboratory Bench SPECIFICATIONS Purified water specifications Grade 2 water resistivity Grade 2 water conductivity icles >0.22 μm Nominal flow, pure water (to storage ) Dispense flow to analyzer Dispense pressure (adjustable) Deionization life (high capacity ) Crystal Clinic >18.2 MΩ x cm <0.055 μs/cm <1 per ml 28 L/h 4 L/min 100 180 kpa 3 m 3 Recovery >30 % Dimensions (WxDxH), cm Pressurized storage 40x50x55 100 L O R D E R I N G I N F O R M A T I O N Feed water pressure Feed water conductivity 1 4 bar < 900 μs/cm Model Crystal Clinic number CL2810 15

CONSUMABLES number Description Replacement criteria Comments 10039 Replacement pre set, Crystal Clinic Filter life counter is zero or the is clogged 10113 Replacement highcapacity deionization DI Err message is shown, or water conductivity is consistently > 0.1 μs/cm 10011 Replacement sterilization UV bulb As required (on average every 3 years) Only systems with 10102 option FLOW DIAGRAM Activated carbon/5um pre Activated carbon/5um pre Reverse osmosis (RO ) quality Check regulator Deionization Pressurized storage UV sterilization (254 nm) quality To analyzer Final pointof use CRYSTAL CLINIC 16

CRYSTAl STERIFEED Sterifeed is a water purification system that is specially designed to produce feed water for autoclaves. Sterifeed produces water with conductivity 511 μs/cm, that is insisde the conductivity range recommended by autoclave vendors. Usually 315 μs/cm is the recommended conductivity range for autoclave feed water for reliable operation of autoclave. D E S C R I P T I O N Water type pure water (Grade 2) Application purified water for autoclaves Display monochrome LCD display Conductivity TOC Monitor Measurement validation port Volumetric dispensing Connection to water dispensing unit pressurized storage, 60 L Installation installable on a wall Pressurized water storage provides consistent water supply to an autoclave. Many autoclaves need pressurized purified water supply. Some autoclaves have priming s for purified water intake, but in case the water supply is not pressurized, an air gap may block the water flow. If the blockage occurs, the operation of autoclave is not possible until the air is removed from the system. Pressurized water storage of the Sterifeed system eliminates any possibility of air gap formation and ensures smooth operation of an autoclave. O R D E R I N G I N F O R M A T I O N Model Crystal Sterifeed SPECIFICATIONS Purified water specifications Purified water conductivity icles >0.22 μm Nominal flow, pure water (to storage ) Deionization life number CS1002 Sterifeed 511 μs/cm <1 per ml 10 L/h N/A Recovery >30 % Dimensions (WxDxH), cm Pressurized storage Feed water pressure Feed water conductivity 50x20x52 60 L 0.5 4 bar < 900 μs/cm CONSUMABLES number Description Replacement criteria Comments 10016 Replacement pre set, Sterifeed Filter life counter is zero or the is clogged Reverse osmosis (RO ) quality 5 μm sediment 1 μm sediment Check To autoclave Pressurized storage Softening cartridge Activated Carbon cartridge CRYSTAL STERIFEED 17

CRYSTAl 7 FLOW DIAGRAM Crystal 7 is an entry level water purification system that produces purified water for general laboratory applications and inorganic analysis. O R D E R I N G I N F O R M A T I O N Model Crystal 7 RO Crystal 7 Pure number C71241 C71001 D E S C R I P T I O N Crystal 7 RO Crystal 7 Pure Water type RO water (Grade 3) pure water (Grade 2) Application General laboratory applications general laboratory applications some methods of inorganic analysis Display monochrome LCD display Conductivity TOC Monitor Measurement validation port Volumetric dispensing Connection to water dispensing unit Installation Not included installable on the wall SPECIFICATIONS Purified water specifications Grade 2 water resistivity Crystal 7 RO Crystal 7 Pure >10 MΩ x cm Grade 2 water conductivity TDS rejection rate >98% <0.1 μs/cm icles >0.22 μm <1 per ml <1 per ml Nominal flow, pure water (to storage ) 7 L/h 7 L/h Dispense flow, pure water 4 L/h 4 L/h Deionization life N/A 1 m 3 Recovery >30 % >30 % Dimensions (WxDxH), cm 50x20x52 50x20x52 Feed water pressure 0.5 4 bar 0.5 4 bar Feed water conductivity < 900 μs/cm < 900 μs/cm 18

FLOW DIAGRAM Reverse osmosis (RO ) quality Check Activated carbon/5µm pre 1μm sediment Pure (Grade 2) water CRYSTAL 7 RO Reverse osmosis (RO ) Check Deionization quality Activated carbon/5µm pre 1μm sediment Pure (Grade 2) water CRYSTAL 7 PURE 19

ONSITE+ AND CONNECT SERIES Onsite+ and Connect are hiend polishing water purification systems. The feed water must be pretreated by reverse osmosis or distillation. Systems are recommended for laboratories with average daily consumption of water within 510 litres. Onsite+ series systems contain an embedded that has to be filled with pretreated water before operation. Pretreated water can be obtained by distillation or reverse osmosis. For user convenience the Onsite+ system comes with additional 5L carboy. The carboy has a stopcock and handle for easy transportation of water from water still to the Onsite+ unit. Connect series systems should be connected to a water pre treatment unit or a distilled water distribution system in a lab. The pretreatment system should maintain water pressure of no less than 1 bar. O R D E R I N G I N F O R M A T I O N Model Onsite+ Trace Onsite+ HPLC Onsite+ Bio Connect Trace Connect HPLC Connect Bio number CB1901 CB1903 CB1905 CB1701 CB1703 CB1705 Water quality validation kit 10913 Software compliant to GLP & CFR 21 410162 D E S C R I P T I O N ONSITE+ S E R I E S Trace HPLC Bio Water type ultrapure water (Grade 1) ultrapure water (Grade 1) ultrapure water (Grade 1) Application Display atomic absorption spectrometry plasma optical emission spectrometry other inorganic trace analysis chromatography mass spectrometry microbiology molecular biology Color graphic LCD display highly sensitive biology applications Conductivity TOC Monitor option Measurement validation port Volumetric dispensing Connection to water dispensing unit Installation Integrated 5L installable either on a laboratory bench or on a wall 20

D E S C R I P T I O N CONECT S E R I E S Trace HPLC Bio Water type ultrapure water (Grade 1) ultrapure water (Grade 1) ultrapure water (Grade 1) Application Display atomic absorption spectrometry plasma optical emission spectrometry other inorganic trace analysis chromatography mass spectrometry microbiology molecular biology Color graphic LCD display highly sensitive biology applications Conductivity TOC Monitor option Measurement validation port Volumetric dispensing Connection to water dispensing unit Installation Not included installable either on a laboratory bench or on a wall SPECIFICATIONS Ultrapure water parameters Onsite+/Connect system configuration Trace HPLC Bio Ultrapure water resistivity 18.2 MΩ x cm 18.2 MΩ x cm 18.2 MΩ x cm Ultrapure water conductivity 0.055 μs/cm 0.055 μs/cm 0.055 μs/cm Total Organic Carbon (TOC) level <10 ppb <2 ppb <2 ppb RNase <0.01 ng/ml DNase <4 pg/μl Bacteria < 1 CFU/mL < 1 CFU/mL < 1 CFU/mL Endotoxins <0.15 EU/mL <0.15 EU/mL < 0.001 EU/mL icles >0.22 μm <1/mL <1/mL <1/mL life* 1 m 3 1 m 3 1 m 3 Dimensions (WxDxH), cm 30x40x60 30x40x60 30x40x60 Feed water conductivity < 30 μs/cm < 30 μs/cm < 30 μs/cm * life depends on feed water quality. CONSUMABLES number 10029 Description Replacement criteria Comments When indicated on the display or water conductivity is constantly > 0.1 μs/cm during recirculation 10018 UV photooxidation bulb 23 years on average Only for Bio and HPLC 10012 Pointofuse micro Every 6 12 months Only for Trace and HPLC 10120 Pointofuse ultra Every 6 12 months Only for Bio 21

FLOW DIAGRAM Dispense meter Pump Conductivity Point of use micro (HPLC configuration) Point of use ultra (Bio configuration) ONSITE+ TRACE Pump Dispense meter Check TOC Conductivity Point of use micro (HPLC configuration) Point of use ultra (Bio configuration) Solenoid Photooxidation ONSITE+ HPLC/BIO Check Dispense meter Pump Conductivity Point of use micro (HPLC configuration) Point of use ultra (Bio configuration) reducer Check Water Inlet CONNECT TRACE reducer Check Pump Check Check TOC Solenoid Dispense Conductivity meter Point of use micro (HPLC configuration) Point of use ultra (Bio configuration) Water Inlet Photooxidation CONNECT HPLC/BIO 22

ACCESSORIES For increased convenience of use of the Adrona water purification systems, choose from the variety of accessories to meet your specific needs. S T O R A G E T A N K S Adrona water purification systems can be equipped with water storage s of various capacity. Depending on the consumption of purified water, user can choose the starting from with capacity of 10 litres up to 300 litres. All the storage s are equipped with level and. WATER STORAGE TANK PRO Specially designed for significant reduc tion of microbiological contamination pos sibilities Features: Capacity 25 litres Opaque housing walls for protection against light Conical bottom for complete draining Ergonomical design Equipped with stopcock system for maintaining the water quality Automatic UV sanitization (UV lamp) (option) Multiposition level, that enables precise control of remaining water Fast pure water (option) WATER DISPENSING UNIT Water dispensing unit provides more convenient use of Adrona systems. One water purification system can be equipped with 2 water dispensing units. Adjustable in all dimensions Manual and/or volumetric dispensing with teaching mode Colour graphic LCD display Full remote control for water purification system Compatible with B30, Onsite+, Integrity+, Connect and E30 systems O R D E R I N G I N F O R M A T I O N Model number Water storage Pro w/multi position level, 25 L 11015 Water storage Basic w/ level and, 25 L 11000 50 L water storage Economy w/ level, 10004 Water storage Comfort w/ level,, 60 L 10007 Water storage Tiny w/ level, tap, 10L 11014 Comfort w/, 100L 10027 Comfort w/, 200L 10026 Comfort w/, 300L 10025 Automatic sanitization for 10315 Water dispensing unit 10305 WATER STORAGE TANK BASIC25 L WATER STORAGE TANK ECONOMY50 L WATER STORAGE TANK COMFORT 60 L 23

Dzerbenes 27, Riga LATVIA, LV 1006 Tel.: +371 67551894, +371 67551993 Fax: +371 67551976 email: info@adrona.lv www.adrona.eu