Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller

Similar documents
Thermally operated mobile air-conditioning system

Waste Heat recovery in industrial batch processes: analysis of combined heat storage and heat pump application.

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

Case studies of thermal energy storage in industrial processes

The Present and Future of Refrigeration, Power Generation and Energy Storage. R.Z. Wang Shanghai Jiao Tong University

Providing free cooling from low temperature waste heat

Combined Heat and Power

DEVELOPMENT OF A GAS-FIRED DOMESTIC HEAT PUMP

SorTech package solution description

Customized Absorption Heat Pumps for Utilization of Low-Grade Heat Sources

Analysis of Solar Thermal Cooling System Using TRANSOL

Identified technologies for the InfraSUN pilot plant

APPLICATION OF CUSTOMIZED ABSORPTION HEAT PUMPS WITH HEATING CAPACITIES ABOVE 500 kw PROJECT: ACKERMANNBOGEN, MUNICH

SOLAR COOLING WITH SMALL SIZE CHILLER: STATE OF THE ART

Thermal Energy Storage in industrial processes

Experimental Research and Performance Analysis of a Solar-Powered. Air-conditioning System in a Green Building

Innovation in carbon-ammonia adsorption heat pump technology: a case study

Cool Producing Systems Based on Burning and Gasification of Biomass

Bringing an energy neutral built environment in the Netherlands under control

ENGINEERING ASSESSMENT OF REACTOR DESIGNS FOR THERMOCHEMICAL STORAGE OF SOLAR HEAT

Advanced heat driven cooling cycles for low-temperature waste heat recovery

Eurammon Symposium Ammonia Absorption Refrigeration. Colibri b.v.

USING HEAT FOR COOLING

New age adsorption cooling & recuperative power. Enwave District Energy Pacific Northwest National Laboratory. June Brandon Oyer, P.E.

TRIGENERATION TECHNOLOGY

Performance analysis of a new single effect hot water absorption chiller system

Possibility of using adsorption refrigeration unit in district heating network

A Perspective on Heating Technology

Inventaire des installations de climatisation solaires en Europe Inventory of solar cooling installations in Europe

HEAT PUMP MISCELLANY

GASIFICATION: gas cleaning and gas conditioning

SOLAR ENERGY USED FOR HEATING AND COOLING SYSTEMS

Solar cooling potential in tourist complexes in the North Aegean

Energy Saving Report. Frigi-Tech Oil Additive. Application. In HKU Central Plant. Chiller No. 3

THERMAL ENERGY ANALYSIS OF SOLAR POWERED VAPOUR ABSORPTION COOLING SYSTEM

Performance Analysis of a Solar Powered Adsorption Cooling System

Comfort Cooling Application Using Fixed Focus Solar Parabolic Dish Concentrator Integrated with Double Effect Vapor Absorption Machine

Effects of Fin Spacing on Temperature Distribution through Finned Tube Adsorber Beds: Vehicle Air Conditioning Applications

Innovative Systems for Solar Air Conditioning of Buildings

Solar Cooling Technologies for Southern Climates - A System Comparison

Experimental Study on Two Beds Adsorption Chiller with Regeneration

EXPERIMENTATION AND MODELLING OF A SMALL-SCALE ADSORPTION COOLING SYSTEM IN TEMPERATE CLIMATE. July 22, 2013

The technical choices for the 12 MW Bio-SNG demonstration in the Netherlands

The Path Towards Zero Energy District Cooling Plant in Qatar. Salah Nezar, LEED AP, QSAS GCP, Sustainability Director, QPM

Energy Mix Opportunity of Vapor Absorption Refrigeration System Integrated With Solar Collectors: A Case Study of Hotel Shangri-La

THE ALL-IN-ONE INLET AIR COOLING AND FILTRATION SOLUTION USING YOUR WASTE HEAT FREUDENBERG FILTRATION TECHNOLOGIES

Report on thermal cooling system implementation and performance

Experimental Evaluation of a Triple-State Sorption Chiller

13/10/2011 Air Solutions International Air Solutions I P/L Solutions to Indoor Air Problems Vapor Absorption Chillers 1

Thermodynamic Analysis of Gas Turbine Trigeneration System

Renewable Energy Based Active Cooling System

Module 05 Lecture 35 : Low temperature process design Key words: Refrigeration system

Recent U. S. R&D results from IEA HPP Annex 41

Heat pumps. Oilon ChillHeat. Optimized cooling and heating performance

Building Concepts for a mid-century energy-neutral society

MODELLING OF COMMERCIAL ABSORPTION HEAT PUMP WITH INTEGRAL STORAGE

The MILENA gasification technology for the production of Bio-Methane

Heat pumps. WP5 Education and Economic Promotion

Experimental analysis of heat-pump integrated with solar energy

Prof. Bob Critoph University of Warwick

OPTIMIZATION OF PCM NUMBER IN HOT WATER TANK FOR THE APPLICATION OF SOLAR DRIVEN ADSORPTION CHILLER IN TROPICAL CLIMATE

Solar cooling news from Europe: Post-Palermo wrap-up. Dr.-Ing. Paul Kohlenbach ausscig Solar Cooling conference Melbourne

ENERGY EFFICIENT SYSTEMS Recover & recycle your waste heat

CLOSED CYCLE SOLAR REFRIGERATION WITH THE CALCIUM CHLORIDE SYSTEM

DUBAL Energy Optimization Absorption Chiller Pilot Project

Over 3 decades, the company has helped customers to be competitive and earn community goodwill by :

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

Cooling Innovation. Solar Thermal Cooling with Adsorption Chillers Experiences and Consequences for Future Projects

EXPERIENCES WITH LOWEX PCM CHILLED CEILINGS IN DEMONSTRATION BUILDINGS

December 13, 2012 Energy Efficient Cooling Information Service Webinar Series Christine Brinker and Gearoid Foley CHP with Absorption Chilling

Microscale Waste Heat Driven Cooling System

Thermal Devices and Systems For Enhanced Energy Efficiency

Investigation of the Performance of Trigeneration and CO 2 Refrigeration Systems in Supermarket Applications

Heat Pump Hot Water Supply Systems

Waste heat driven silica gel/water adsorption cooling in trigeneration

A new application of an old idea

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

ST-4 Polygeneration plant. Parc de l Alba Cerdanyola del Vallès

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

Packaged AHR (Advanced Heat Recovery) Systems for Engines, Gas Turbines, & Industrial Waste Heat. Tom Pierson

Guide. Heat Pump Boilers. Information. Issue Ten >

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

EXPERIMENTAL ANALYSIS OF ABSORPTION REFRIGERATION SYSTEM DRIVEN BY WASTE HEAT OF DIESEL ENGINE EXHAUST

Heat pumps. Oilon ChillHeat. Optimized cooling and heating performance

Figure 1: Uncovered and covered PVT collectors

Solar Powered Vapour Absorption Refrigeration (SPVAR) System as a rural microenterprise

Cogeneration. Thermal Chillers. and. .. ASHRAE National Capital Chapter. Arlington, VA 10/10/2012

Department of Mechanical and Materials Engineering. Solar Energy Research Institute Faculty of Engineering and Built environment.

Low temperature cogeneration using waste heat from research reactor as a source for heat pump

EVALUATION OF SOLAR SORPTION REFRIGERATION SYSTEM PERFORMANCE IN LATVIA

Solar cooling plants: how to arrange solar collectors, absorption chillers and the load

EVASOLK. Evaluation of Solar Cooling in Comparison to Reference Technologies

DESIGN OF VAPOUR ABSORPTION REFRIGERATION SYSTEM OF 1.5TR CAPACITY BY WASTE HEAT RECOVERY PROCESS

HEATING SYSTEM RETURN TEMPERATURE EFFECT ON HEAT PUMP PERFORMANCE

Modeling and analyzing solar cooling systems in Polysun

ABSORPTION COOLING UNIT DRIVEN BY SOLAR ENERGY

BUILDING FOR THE FUTURE

Study on Ejector - Vapor Compression Hybrid Air Conditioning System Using Solar Energy

SOLAR POWER GENERATION AND SOLAR COOLING TRIGENERATION: A NEW APPROACH OF CONCEPTUAL DESIGN FOR COUNTRIES OF MENA REGION

Compound ejectors with improved off-design performance

Transcription:

Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller E.-J. Bakker R. de Boer S. Smeding N. Sijpheer M. van der Pal September 2013 ECN-B--13-011

DEVELOPMENT OF AN INNOVATIVE 2.5 kw WATER-SILICA GEL ADSORPTION CHILLER Ernst-Jan Bakker, Robert de Boer, Simon Smeding, Niels Sijpheer, Michel van der Pal Energy research Centre of the Netherlands, PO Box 1, 1755 ZG, Petten, The Netherlands r.deboer@ecn.nl Abstract: Besides (better) utilization of available solar heat or waste heat, and thereby reduction of fossil fuel consumption, sorption cooling offers several other advantages compared to conventional compression cooling. Such as reduction of summer peaks in the electricity grid, use of natural refrigerants, and low noise & maintenance. Sorption cooling in itself is not a new development. However, the development of small scale sorption chillers (2-20 kw) is new. This development allows sorption cooling to enter the markets for individual homes, small collective systems and small commercial applications. A second trend is gradual reduction of the driving temperatures of the sorption cycles allowing more solar and waste heat to be used. This article describes the design and performance of a new, innovative 2.5 kw adsorption chiller, developed by ECN. This system was built and tests have been performed in a laboratory and in one of ECN s full-scale research houses. Key Words: adsorption chiller, silica gel, prototype, performance 1 INTRODUCTION Triggered by the potential of waste heat (e.g. from industry) and renewable heat (e.g. from the sun), the Energy research Centre of the Netherlands (ECN) initiated development of sorption cooling technology several years ago. Recent work was done within the framework of the European (FP6) PolySMART project (www.polysmart.org). Water-silica gel was chosen as a working pair for the cooling machine: a choice that has proven to be successful so far. Compared to conventional compression cooling, thermally driven cooling (TDC) offers several advantages, e.g.: Using heat instead of electricity reduces peaks on the electricity grids Using renewable heat reduces carbon emissions. Many sorption cycles are based on natural refrigerants. TDC s have low noise levels and low maintenance and installation requirements. Just like a conventional compression chiller, an adsorption chiller uses a cycle where a refrigerant condenses at high pressure/temperature and evaporates at low pressure/ temperature. However, this cycle is not driven by a mechanical compressor but uses thermal compression, based on the sorption reaction of silica gel and water, using heat as the driving force. Dry silica gel (a porous, glass-like solid) attracts and adsorbs water vapour until it is saturated, and must then be regenerated. Heating the silica gel releases the water vapour at a pressure that allows it to condense at ambient temperatures, after which the cycle of adsorption and de-sorption can be repeated. This cycle is not unlike absorption cycles (with e.g. LiBr-solution), there are two important differences: 1. The silica gel can be regenerated efficiently at lower driving temperatures 2. The silica gel is a solid that cannot be pumped from generator to absorber The silica gel is applied to the surfaces of heat exchangers, which are supplied intermittently with hot and cooling water. The adsorption cycle is therefore a batch process, and for quasi-

continuous cooling at least two silica gel beds (reactors) are needed, operating in counterphase. A schematic system lay-out of an adsorption chiller is shown in Figure 1. The lowest possible chilled water temperature of this adsorption cycle is about 4 C, making it perfectly suited for air-conditioning and chilled water systems in the built environment and in industry. Heat rejection condenser Sorbent heat exchangers cooling water circuit Hot water circuit Heating source Cold distribution evaporator Chilled water circuit Figure 1: Schematic adsorption chiller lay-out 2 DESIGN AND CONSTRUCTION OF THE 2.5 kw ADSORPTION CHILLER As part of the European PolySMART project (www.polysmart.org), ECN has developed a small-scale adsorption chiller using water-silica gel as working pair, which is tested and demonstrated. The starting point for this chiller is to supply sufficient cooling power (2.5 kw) for a modern single-family house. A common (challenging!) standard for household appliances is used to determine the physical size limits: a 60 x 60 cm footprint, and a height of about 100 cm. Compact light-weight aluminium heat exchangers from the automotive industry have been used to carry the silica gel, creating a large surface while maintaining low weight and volume. For the same reason, this type of heat exchanger has also been used for the condenser and for the evaporator. Figure 2 shows the layout of the new chiller: the evaporator at the bottom, two silica gel reactors above the evaporator, and the condenser on top. Water vapor flows at low pressure from the evaporator (creating a cooling effect) and is adsorbed in one of the two silica gel reactors (adsorption phase). At the same time, water vapor flows from the other reactor to the condenser (desorption phase) at a higher pressure. Special check valves have been placed between these components to prevent the water vapor from flowing back. This (low pressure) process requires that the system does not contain any gases or vapors other than water vapor, and that all components are hermetically sealed. The water from the condenser flows back to the evaporator via a condensate return line. The flow for heating and cooling of the silica gel is controlled by eight valves, which intermittently supply both reactors. A PLC unit is included in the chiller to control these valves and to monitor temperatures and pressures.

Figure 2: Design drawing and picture of the ECN 2.5 kw adsorption chiller 3 PERFORMANCE MEASUREMENTS The performance of the chiller was first determined in the laboratory and afterwards in a micro-trigeneration setup in one of ECN s research dwellings. 3.1 Laboratory measurements The prototype adsorption chiller has been tested in an ECN laboratory, with the facilities to control flow rates and temperatures for hot, cooling and chilled water. Hot, cooling and chilled water temperatures strongly influence the chillers performance. The following inlet temperatures are used as nominal operating conditions for driving heat, regeneration and chilling: 80 C, 30 C and 15 C respectively. The influence of cycle time on thermal performance has been determined for these operating conditions. The cycle time is the duration of a complete cycle of heating up and cooling down of one reactor. Figure 3 shows the cooling power (left axis) and coefficient of performance (right axis, ratio of cooling power and driving heat). For this application, the coefficient of performance is defined as: COP Q Q evaporator heatsource (1) Figure 3 shows that cycle times under six minutes are not useful, because both cooling power and COP show a decrease (because this short cycle time does not allow all the silica gel to go through the complete temperature cycle). With increasing cycle times (>10 minutes), a decrease in cooling power is compensated by an increase in efficiency (because fewer changes between heating and cooling of a reactor mean less thermal losses).

RESULTS FROM LAB TEST 3,0 0,7 2,5 0,6 P Chill [kw] 2,0 1,5 1,0 0,5 P COP 0,5 0,4 0,3 0,2 0,1 COP [-] - - 5 10 15 20 Cycle time [min] 0,0 Figure 3: Influence of cycle time on the thermal performance of the adsorption chiller Figure 4 shows the influence of the cooling water and chilled water inlet temperature on the chiller performance. The measurements were all performed with a fixed cycle time of 12 minutes. Chiller performance clearly benefits from high chilled water temperatures and relatively low cooling water temperatures. The laboratory tests show that the ambitious design specifications for this prototype have been achieved. Nearly 2.5 kw cooling power can be produced with a compact machine (power density of 7 kw/m 3 ) at a respectable COP. P Chill [kw] P Chill [kw] 5 4 3 2 1 PERFORMANCE VS CHILLED WATER TEMPERATURE 5 10 15 20 T chilled water [ C] 0,5 COP [-] 0,4 PERFORMANCE VS COOLING WATER TEMPERATURE 4 0,8 0,7 P 3 0,6 COP 0,5 COP [-] 2 0,4 0,3 1 0,2 0,1 0 0 20 25 30 35 40 45 50 T cooling [ C] Figure 4: Influence of cooling water (below) and chilled water (upper) inlet temperature on the chiller performance P COP 0,8 0,7 0,6 0,3 0,2 0,1 0

3.2 Measurements in research dwellings The research dwelling that is used, is in one of the four full-scale single family dwellings at ECN in Petten, Netherlands as shown in Figure 5. The size of these dwellings represents the Dutch average for new dwellings. The research dwellings are equipped with an extensive data acquisition system, logging every 10 minutes more than a 100 sensors. These systems register energy flows such as passive (windows) and active (collector) solar radiation, electricity use but also temperature, humidity and if necessary carbon dioxide levels. The data acquisition also allows to measure on the component level such as: electricity use of circulation pumps or controls, heat supplied by heating systems, temperature and humidity (comfort aspects) etc. The measurements with the adsorption chiller are performed with the installation setup as shown in Figure 6. Figure 5: The four single family dwellings. The second house to the left is used for measurements with the adsorption chiller Figure 6: Installation setup of the adsorption chiller and a gas-fired boiler as heat source In Figure 6 a gas fired boiler is used to supply the heat to the chiller. A dry cooler is positioned outside the building to reject the heat of condensation and the heat of adsorption coming from the chiller. The boiler was applied as a forerunner for the intended micro-chp system (combined heating and power), to provide the driving heat for the chiller. The installation of the micro-chp was delayed due to limited pre-commercial availability.

P chill [kw] COP [-] Chapter 4: Thermally Driven Heat Pumps for Cooling As can be seen in the graphs in Figure 4, the performance of the chiller is strongly influenced by the chilled water temperature and the cooling water temperature. To be able to compare measurements that are performed under different conditions, COP and cooling power can be plotted against the so-called reduced temperature. The reduced temperature is defined as: Tcooling(in) Tchilledwater T reduced (2) T T hot(in) cooling(in) The following graphs (Figure 7) show the results from measurements in the research dwelling and the laboratory. The horizontal axes represent the reduced temperature, allowing comparing the results from lab and research dwelling. 1.0 LABMEASUREMENT AND MEASUREMENTS IN DWELLINGS 0.8 Dwelling Lab 0.6 0.4 0.2 0.0 0.0 0.1 0.2 0.3 0.4 0.5 T reduced [-] 3.5 3.0 2.5 2.0 1.5 1.0 0.5 LABMEASUREMENT AND MEASUREMENTS IN DWELLINGS Dwelling Lab 0.0 0 0.1 0.2 0.3 0.4 0.5 T reduced [-] Figure 7: Comparison of the adsorption chiller performance between laboratory and research dwelling measurements The measurements in the research dwelling demonstrate that the prototype adsorption chiller can also operate successfully under realistic operating conditions. Also, the difference in performance from measurements in the laboratory and the research dwelling is shown.

3.3 Measurement analysis The comparison of the measured data shows reduction in performance of the chiller under operating conditions in the dwelling compared to the performance under laboratory conditions. The available cooling power was reduced by 25 to 30% compared to the laboratory results. The performance of the prototype chiller under operating conditions in the dwelling can be improved by the following design adjustments: - improvement of the refrigerant valve design; - improvement of the refrigerant liquid level control in the evaporator; - reconsider evaporator design to avoid pool boiling; - reconsider material use to reduce any corrosion. If these adjustments are being incorporated in a second prototype, the expectation is that the performance will increase with 10%. Also the difference in performance between lab and practical conditions will be reduced. 4 CONCLUSION AND OUTLOOK A new adsorption chiller prototype was successfully developed, designed, built, commissioned and tested in laboratory conditions and in more real life conditions in a research dwelling. The laboratory measurements indicated a nominal cooling power of 2.5 kw with a COP of 0.5, in accordance to the design targets. The thermal performance increases with higher chilled water delivery temperatures and with lower heat rejection temperatures. Measurements results under the operating conditions in one of ECN s research dwellings, showed a lower cooling power and COP in comparison to the laboratory measurements. The two sets of measurements helped to address future adjustments to the design that can improve a commercial version. The adsorption chiller that is developed by ECN is ready to be commercialized. 5 REFERENCES Bakker, E.J., N.C. Sijpheer 2004. Ecobuild Research: full-scale testing of innovative technologies for energy efficient houses, Report Energy Research Centre of the Netherlands (ECN), Petten, The Netherlands. Bakker, E.J., N.C. Sijpheer 2008. Testing a prototype gas-fired residential heat pump, Proc. 9 th Int. Heat Pump Conference 2008, Zurich, Switzerland. Boer, R. de., E.J. Bakker 2010. Development of a new 2.5 kw adsorption chiller for heat driven cooling, IEA Heat pump Newsletter, Vol. 28, 1/2010, pp. 39-42. Boer, R. de., R.J.H. Grisel, S.F. Smeding 2010. Waste heat driven silica gel/water adsorption cooling in trigeneration, Applied Thermal Engineering, Vol. 30, pp. 1039-1046. Sijpheer N.C. et al. 2007. Floor cooling and air-cooling, the effects on thermal comfort of different cooling systems, Report Energy Research Centre of the Netherlands (ECN), Petten, The Netherlands.

ECN Westerduinweg 3 P.O. Box 1 1755 LE Petten 1755 LG Petten The Netherlands The Netherlands T +31 88 515 4949 F +31 88 515 8338 info@ ecn.nl www.ecn.nl 8