Magnum Board Section Digicon Information Inc. Page 1

Similar documents
Magnum Board Section Digicon Information Inc. Page 1

Highland Manor Dr Suite Website:

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION CEMENTITIOUS SHEATHING

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

SECTION GYPSUM BOARD

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Sept 30, 2004 Page 1

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Octaform Quick Liner Wall & Ceiling Panels Guide Specification CAN Page 1

BEARING METAL STUD FRAMING

Architectural Wall Products Guide Specifications

EQUITONE is a material supplier. Installation Contractors shall be trained and approved by EQUITONE.

SPECIFICATION GUIDELINE

BENJAMIN OBDYKE INCORPORATED

Phenolic Exterior Wall Cladding

SECTION STRUCTURAL INSULATED PANELS

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Product Guide Specification

Note to Specifier: Use this product for coated glass-mat faced polyisocyanurate insulation boards such as Rboard.

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA

Gold Bond BRAND Gypsum Sheathing

Architectural Roof and Wall Products Guide Specifications

SECTION GYPSUM BOARD ASSEMBLIES

EQUITONE is a material supplier. Installation Contractors shall be trained and approved by EQUITONE.

Architectural Roof Products Guide Specifications

MASTERFORMAT SPECIFICATION

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION THERMAL INSULATION

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

SECTION GYPSUM BOARD

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

SECTION Fiber Reinforced Stucco 1

GA APPLICATION OF GYPSUM SHEATHING

SECTION GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.01 SECTION INCLUDES

Architectural Roof Products Guide Specifications

SECTION GYPSUM BOARD ASSEMBLIES

A. Meet at Project site <insert number> days before starting installation.

COMPOSITESIDING

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

Product and System Specifications DuPont Flashing Systems

~ 100 R~~UU~]ION ~ 9RIMIOS Most Wiael>: AcceBtedana Trusted

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

SECTION STAINLESS STEEL WALL PANELS

ROCKWOOL Board Insulation Section Master Guide Specification Page 1 Jan 2017

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)

SPECIFICATION GUIDELINE

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

by Rollfab Metal Products

ROCKWOOL Board Insulation Section Master Guide Specification (ROCKBOARD 80) Page 1 January 2017

EcoTouch Insulation with PureFiber Technology

ROCKWOOL Blanket (and Batt) Insulation Section Master Guide Specification Page 1 Jan 2017

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Architectural Roof and Wall Products Guide Specifications

SECTION COLD-FORMED METAL TRUSSES

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

ROCKWOOL Blanket (and Batt) Insulation Section Master Guide Specification (ROXUL SAFE ) Page 1 Jan 2017

SECTION MANUFACTURED MASONRY VENEER

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

ALUMABOARD SECTION ALUMINUM SIDING AND SOFFITS. A. Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

Henri Fennell, CSI/CDT ABX 2015

Acrytec NC 25 & NC 25 Insulated Glass-Fiber Reinforced Cementitious (GFRC) Rainscreen Panel System

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

Guide Specification for the OSI QUAD Window and Door Flashing System

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

SECTION COMPOSITE CLADDING. Display hidden notes to specifier. (Don't know how? Click Here)

Construction Standards PAGE

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

Master Specification WALLTITE Eco v.3 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

ROXUL Blanket (and Batt) Insulation Section Master Guide Specification (AFB) Page 1 April 2015

ROCKWOOL Board Insulation Section Master Guide Specification (CURTAINROCK 80) Page 1 January 2018

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

Master Specification ENERTITE by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

SECTION METAL WALL PANELS

Master Specification WALLTITE ECO v.2 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

CENTRIA FORMABOND II Metal Composite Wall System

Magnum Board Coatings

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Architectural Roof and Wall Products Guide Specifications

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

LUX Specifications. Section S - Preformed Steel Siding

Transcription:

Digicon Information Inc. Page 1 This section includes sheathing for exterior walls for use in a potentially damp or wet exterior cladding environment. This sheathing section forms an exterior flat plane for the exterior wall framing members. The sheathing forms the exterior skin of the inner "wythe" of a rain screen wall assembly and usually functions as a moisture-resistant backing or as a substrate for a full contact waterproof liquid or sheet membrane. An air space is required by the NBC (for moisture collection and drainage - as well as an air pressure equalizer) prior to installing a weather stop exterior wall finish. This section includes performance, proprietary and descriptive type specifications; edit text to avoid conflicting requirements. Part 1 General 1.1 SECTION INCLUDES In this article, select the components or assemblies that are intended to be part of the content of this section and will not be included in other sections..1 Exterior magnesium oxide sheathing for walls. 1.2 RELATED SECTIONS In this article, indicate those sections that inter-rely on this section. The listing below is only partial and should be edited to include those sections specific to the project that describe subjects or products that affect this section directly..1 Section 05 41 00 - Structural Metal Lightweight Framing: Load bearing studs for exterior applications..2 Section 06 11 00 - Wood Framing: Building wood framing assembly with openings for windows and doors..3 Section 06 10 13 - Wood Blocking and Curbing: Wood blocking for support of [ ]..4 Section 07 21 16 - Blanket Insulation: Thermal insulation within exterior wall framing. 1.3 REFERENCES Edit this article after editing the rest of this section. Only list reference standards below, that are included within the text of this section, when edited for a project specification delete other references that do not apply..1 International Code Council Evaluation Service Inc. (ICC-ES).1 Acceptance Criteria AC386 for Fiber-Reinforced Magnesium-Oxide-Based Sheets..2 ASTM C1185-08(2012) - Standard Test Methods for Sampling and Testing Non- Asbestos Fiber-Cement Flat Sheet, Roofing and Siding Shingles, and Clapboards..3 ASTM C1186-08(2012) - Standard Specification for Flat Fiber-Cement Sheets..4 ASTM C1325-08b - Standard Specification for Non-Asbestos Fiber-Mat Reinforced Cementitious Backer Units..5 ASTM E72-13a - Standard Test Methods of Conducting Strength Tests of Panels for Building Construction.

Digicon Information Inc. Page 2.6 ASTM E84-13a - Standard Test Method for Surface Burning Characteristics of Building Materials..7 ASTM E119-12a - Standard Test Methods for Fire Tests of Building Construction and Materials..8 ASTM G21-13 - Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi..9 UL 263 - Fire Tests of Building Construction and Materials 2011. 1.4 PERFORMANCE REQUIREMENTS Edit this article carefully; restrict statements to identify assembly or system performance requirements or function criteria only. Delete paragraphs not appropriate to the project. Performance specifying permits system manufacturers the latitude to adjust or redesign proprietary systems to achieve requirements specified in this section..1 Surface Burning Characteristics: Classified as non-combustible when tested in accordance with ASTM E84 and E136. 1.5 SUBMITTALS FOR REVIEW Do not request submittals if this specification section or drawings sufficiently describe the products of this section or if proprietary specifying is used. The following submittals are intended for review to determine eligibility for the project..1 Section 01 33 00: Submission procedures..2 Product Data: Provide product data on [magnesium oxide sheathing] [metal framing]..3 Shop Drawings:.1 Indicate special details associated with [lap and seal to window frame air barrier plane] [sealing penetrations]..2 Indicate fastener type and spacing to suit framing details. Use the following paragraph for submission of physical samples for selection of finish, colour, texture, etc..4 Samples: Submit [two (2)] samples, [<[ ] mm><<[ ] inches>>] in size. 1.6 SUBMITTALS FOR INFORMATION The following submittals are for information only; do not request these submittals if the information submitted will be assessed for acceptability..1 Section 01 33 00: Submission procedures..2 Installation Data: Manufacturer's special installation requirements. Include the following ONLY if specifying for a LEED project. Specify only the technical requirements necessary to achieve the credits desired for this project..3 Sustainable Design:.1 Section 01 35 18: LEED documentation procedures.

Digicon Information Inc. Page 3.2 Provide required LEED documentation for Product [recycled content] [regional materials]..3 Manufacturer's Certificate: Certify that Products meet or exceed [specified requirements]. 1.7 CLOSEOUT SUBMITTALS The following submittals are for project closeout purposes; do not request these submittals if the information submitted will be assessed for acceptability..1 Section 01 78 10: Submission procedures. Include the following ONLY if specifying for a LEED project..2 Sustainable Design Closeout Documentation: [ ]. 1.8 QUALITY ASSURANCE This article includes statements that require quality applicable to the whole section..1 Perform Work in accordance with manufacturer s written instructions and Technical Bulletin No. 111309-1108. VERIFY TECH BULLETIN REF#.2 Applicator Qualifications: Company specializing in performing the work of this section with minimum [three (3)] years documented experience [and approved by the manufacturer]. 1.9 DELIVERY, STORAGE, AND PROTECTION.1 Section 01 61 00: Transport, handle, store, and protect products..2 Protect materials from warping or other distortion by stacking in flat sheets, off the ground..3 Protect stockpiled materials from weather using waterproof tarps. Part 2 Products 2.1 MANUFACTURERS This article is for proprietary specifying with one or more manufacturers. Use the first and third paragraphs for specifying a single manufacturer. If specifying a product by reference to a standard only, delete this article. Additional manufacturer s data can be found at http:// www.magnumbp.com..1 Magnum Building Products, LLC.1 10150 Highland Manor Drive, Suite 200.2 Tampa, Florida.3 33610.4 Tel: (813) 314-2202.5 Fax: (813) 314-2203.6 Web: www.magnumbp.com

Digicon Information Inc. Page 4.2 Other acceptable manufacturers offering functionally [and aesthetically] equivalent products..1 [ ]; Product: [ ]..2 [ ]; Product: [ ]..3 [ ]; Product: [ ]..3 Substitutions: [Not permitted] [Refer to Section 01 62 00]. 2.2 MATERIALS Include the following paragraphs for magnesium oxide sheathing not specified in other sections such as the roof deck preparation part of relevant sections in Division 07. Non-fire rated Magnum Board is available in panel thicknesses from 3 mm (1/8 inch) to 25 mm (1 inch) and 1220 mm (4 feet) width x 2440 mm, 2745 mm, 3050 mm and 3660 mm (8, 9, 10 and 12 feet) lengths. Fire rated Magnum Board is only available in 12 mm (15/32 inch) panel thickness and 1220 mm (4 feet) width x 2440 mm, 2745 mm, and 3050 mm (8, 9, and 10 feet) lengths..1 Magnesium Oxide Sheathing: Fibre-reinforced homogeneous panel, paperless, moisture resistant; maximum available length in place ends square cut, square edges..1 Regular, non-fire rated, [<3 mm><<1/8 inch>>] [<13 mm><<1/2 inch>>] [<16 mm><<5/8 inch>>] [<25 mm><<1 inch>>] [<[ ] mm><<[ ] inch>>] thick..2 Fire rated, <12 mm><<15/32 inch>> thick. 2.3 FRAMING MATERIALS This article is to identify wood or metal framing substrates to which the sheathing is to be applied..1 Metal Framing and Accessories: Specified in Section [09 22 13] [09 22 16] [05 41 00]..2 Wood Framing: Specified in Section [06 11 00] [06 10 13]. 2.4 ACCESSORIES.1 Fastening: Corrosion resistant [self-tapping screws][pneumatic nails][adhesive] as recommended by manufacturer. Part 3 Execution 3.1 EXAMINATION.1 Section 01 70 00: Verify existing conditions before starting work..2 Verify that site conditions are ready to receive work and opening dimensions are as [instructed by the manufacturer] [indicated on shop drawings]. 3.2 SHEATHING INSTALLATION.1 Install in accordance with manufacturer s written instructions.2 Coordinate location of openings and through-wall components with other work.

Digicon Information Inc. Page 5.3 Erect magnesium oxide sheathing [vertically] [horizontally], with edges butted tight and ends occurring over firm bearing..4 Use screws when fastening magnesium oxide sheathing to furring or framing..5 Treat cut edges and holes in sheathing with sealant. Control joint spacing in this work should not exceed 10 m (30 ft) for linear work and may also be placed above metal door frames directly above each jamb. Joints constructed of back to back casing beads can be filled with a low modulus sealant capable of flexible joint movement. The following paragraph offers the option to permit site directed placement of control joints..6 Place sealable exterior control joints consistent with lines of building spaces [as directed by Consultant] [as indicated on Drawings] [to maximum spacing of [<[ ] m><<[ ] ft>>] [<10 m><<30 ft>>] ]. Form joint with back to back casing beads spaced apart to form a flexible sealant joint. 3.3 ERECTION TOLERANCES Do not assume that there are industry standards for tolerances. Specify tolerances below as appropriate to the nature or character of the project. Verify that such tolerances are realistic and realizable..1 Section 01 73 00: Tolerances..2 Maximum Variation of Magnesium Oxide Sheathing Surface from True Flatness: [<6 mm in 3 m><<1/4 inch in 10 ft>>] in any direction. END OF SECTION