Giuseppe Giordano Founder & CEO

Similar documents
The energy benefits of View Dynamic Glass

17% 2,300,000 AED. Project Case Study. Fairmont the Palm

Zero Net Energy Buildings February 12, 2014 Beth Brummitt, CEM, CEA, LEED AP. Your guide for improving the performance and value of buildings

Understanding Energy Performance Of The Ku-ring-gai Fitness And Aquatic Centre. Peter Vun Ku-ring-gai Council

Xavier University of Louisiana

Allstream Centre Energy Performance Report

95% U.S. Commercial Properties are less than 5,000 square meters. Vision/Problem Bringing custom energy control to small & medium commercial buildings

Low-Hanging Fruit Simple Steps Toward Energy Effective Building Operations

TVA Melton Hill Dam Sustainable Recreation Area

Clean Energy Extension

18 th National Award Excellence in Energy Management Zonal Office, New Delhi

Managing Energy Use and Cost with Integrated Metering

LIBRARY ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

Assessment of Climate Change Robustness of a Deep Energy Retrofit Design of an Existing Day Care Centre

White Paper. HVLS Fans and Energy Savings. Dubai Case Study. Featuring Altra-Air Fans with WhalePower Technology from Envira-North Systems

The Energy and Sustainability Advantage:

Deep Energy Retrofit of a HighRise MURB

2/17/2017. Energy Accounting & Education. Topics (Electricity) Creating Electricity

Continuous Commissioning Leading Energy Project Process - An Industry Approach

NYSERDA High Performance Development Challenge Energy Monitoring Report Hudson Passive Project

Electric Forward Market Report

Premium Sample Reports

Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings

Greening Buildings at the Dallas/Fort Worth International Airport. Sustainable Communities Conference Dallas, TX. March 10, 2009

Greening Your Business Energy Efficiency in Buildings

IOT SENSOR INTEGRATION IN SMART BUILDINGS FOR MONITORING & CONTROL

Retro-commissioning and on-going commissioning 23 November 2016

Strategies for energy efficiency improvement in residential and office buildings: their role at building and country scale

ENERGY MODELING TOOLS: SOLUTIONS FOR CREATING A HIGH PERFORMANCE BUILDING. Presented by Neil Maldeis Energy Solutions Engineering Leader, Trane

AN INTRODUCTION TO WEATHER NORMALIZATION OF UTILITY BILLS FOR ALTERNATIVE ENERGY CONTRACTORS. John Avina, Director Abraxas Energy Consulting

Sample Reports. for. HAP v4.80 Example Problem

Smart building for a greener Europe: emerging policy and practise

Driving Efficiency with Interval Meter/Smart Meter Data. Mukesh Khattar, Energy Director, Oracle

Future tree planting on the two acre lot will offset remaining lifetime carbon emissions.

Utility Bill Data Accounts Payable s Secret Weapon for Managing Costs and Addressing Stakeholder Questions

Campus Annual Energy Use Report

Your Trusted Partner in Customer Engagement

California Independent System Operator Corporation. California ISO. Import resource adequacy. Department of Market Monitoring

A New Type of Hybrid Groundwater Energy System

Leading Insights into Solar

INTEROFFICE MEMORANDUM

Building Retro-Commissioning

BEYOND O&M. Shawn Maurer SEDAC Building Energy Specialist. Smart Energy Design Assistance Center (SEDAC), University of Illinois at Urbana Champaign

Disaggregating Electric Loads Without Metering Them

SCHOOL ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

1Q 2016 Earnings NASDAQ: TGEN

Commissioning and Retro Commissioning Programs Title Slide for Energy Efficiency

Energy Report - February 2008

TOP 10 STRATEGIES FOR NEW AND EXISTING BUILDINGS

Energy Modeling Tools Solutions for Creating an Intelligent Building

The DHP-AQ Air/Water Heat Pump Savings worth celebrating

Farm Energy Efficiency June Collin Macpherson - JCM Solutions

COMPANY PROFILE 2016

Urban Greening and the UHI: Seasonal Trade-offs in Heating and Cooling Energy Consumption in Manchester, UK

GAS FOR HEATING & COOLING. POLICY WORKSHOP 14 June 2016, European Parliament

High-Performing Home Certificate. Certified Solar

CONDENSING TEMPERATURE CONTROL THROUGH ENERGY MANAGEMENT SYSTEM SIMULATON FOR A LARGE OFFICE BUILDING

Carbon Project Annual Report

Stanford University Water Efficiency Program Marty Laporte Jennifer Fitch Thomas Bartleman

NWC District Energy Campus Energy - RFQ Supporting Documentation. April 25, 2018

SIMULATION VERSUS REALITY 4 CASE STUDIES. Anthony Calderone Aurecon, Melbourne, Australia

Is More Always Better? A Comparison of Billing Regression Results Using Monthly, Daily and Hourly AMI Data

Quality Adjustment of Digital Services in Japan s SPPI

Case Study: Holiday Inn Darling Harbour

Healthcare Facilities: Planning for Increasing Extreme Heat Events

Using Prometheus weather files. Andrew Cripps Sustainable Development Group AECOM

Energy Efficiency in Kuwait: Past, Current & Future

Conservation Success & Challenges

SolarCity Partnership. Toronto Fire Station # kwt Solar Water Heating Installation. Technology. Monitoring. Best Practices

Value of Air Source Heat Pumps in Light of Variable Energy Prices. Jeff Haase. Energy Design Conference February 27, 2013

Connected lightning made easy with Interact Pro

9/13/2011. Mark Hanicits, Director of Facilities and Safety, MetroSouth Medical Center. Terry Malloy P.E., Cxa, Project Manager, Teng & Associates

Quality Adjustment of Digital Services in Japan s SPPI

Getting Started with Your First Project: Considering Rules

PARK PLACE CASE STUDY VANCOUVER. Heat reclaim system expected to reduce steam consumption 80%, GHG emissions 68%

Timmins and District Hospital

A Selection Guide for Resource Conservation Managers

PERFORMANCE REPORT. Building Performance Partnership. January 2011 U.S. GREEN BUILDING COUNCIL

Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

Seventh International IBPSA Conference Rio de Janeiro, Brazil August 13-15, 2001

Building Retro-Commissioning

Case study of an ECBC Compliant, Energy Efficient Building: Aranya Bhawan, Jaipur

ECBC Impacts: Experiences from the ECBC Pilot Building in Rajasthan Jyotirmay Mathur Malaviya National Institute of Technology Jaipur, India

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Sample Reports. for. HAP v4.90 Example Problem

Rainwater tank study of new homes

Energy Management in Existing Buildings

SEEK COMFORT ACHIEVE PERFORMANCE Z SMITH ESKEW+DUMEZ+RIPPLE

Intelligent Energy Management for Multi-Unit Operations:

Energy Management Strategies for MURB & Commercial Buildings. Konrad Seemann PL Consulting Corp CEM,CBCP,CEP,CMVP

PV Generation Potential 17.1 kbtu/ft2/yr 15.4

Managing Transition to Retail Competition. Lim Howe Run Managing Director, GCEO s Office Head, Strategic Investments

NORTH AMERICAN MONITORING OF A HOTEL WITH ROOM SIZE GSHPS

How We Obtained LEED Certification pertaining to the Indoor Environmental Quality Category. Ron Fields, CAFS, NCT General Dynamics C4 Systems

Meet the New Standard. in Building Management Solutions for Commercial Buildings

Solar, Wind and Market Power in the New Zealand Electricity Market (and hydro lake dynamics) Mina Bahrami Gholami and Stephen Poletti

Energy Savings Analysis Generated by a Real Time Energy Management System for Water Distribution

Why Use A DES ESCO? Benefits of A DES ESCO?

ECO-RETROFITTING VERY OLD DWELLINGS: CURRENT AND FUTURE ENERGY AND CARBON PERFORMANCE FOR TWO UK CITIES

Transcription:

Giuseppe Giordano Founder & CEO www.enerbrain.com 1 Your innovation partner for a sustainable future

40% of the world s energy is consumed by buildings US Green Building Council

and yet, how often have you experienced discomfort?

indoor air quality impacts performance Taking a test in a room with high CO 2 results in 50% increase in mistakes HEALTH, WELLBEING & PRODUCTIVITY: The impact of green buildings on people and profit, 2016

and it affects businesses bottom line In a mall, when dwell time doubles sales increase by 130% Time is Money. Shoppers buy more when they stay longer. Pathintelligence

most HVAC systems are not up to the task Do not monitor T, Co2 and humidity in real time Require constant supervision by trained staff Proprietary and expensive upgrades and maintenance Image credit: Mattias Adolfsson

So what? High level of energy costs Low level of comfort Strong dependency from system producers Difficult management of building portfolio 7

Enerbrain turns wasteful buildings into sustainable ones EFFICIENCY 30% energy savings and significant CO 2 emissions reduction COMFORT Productivity increase & less sick hours ENGAGEMENT Promote Social Corporate Responsibility 8 Savings calculated according to UNI EN 15603

Energy Cloud: our HVAC IoT retrofit solution Self-learning Algorithms Dynamically fine tunes the best parameters for comfort & savings Mobile App Remote management from any mobile device Environmental Sensors Monitor occupancy, CO 2, T, humidity & air quality HVAC Actuators Connected to the cloud and installed on any HVAC system 9

Sensor - esense T, RH, CO 2 every 10 4 Year Battery Life Sigfox connectivity Already configured 10

Algorithms Energy Cloud Integration through API Input from indoor, weather & historical PID + fuzzy logic EU patent pending 11

Actuators - enode Remotely controls valves & air gates Encrypted communication 3G connectivity SW & HW bypass, electrically failsafe 12

Reports, Dashboards and App Detailed reports Portfolio Management Real time monitoring Remote access 13

Enerbrain in three key points Flexible Advanced Profitable Suitable for any system: 100% compatible with any HVAC system Non invasive 2 days installation Self-learning algorithms with automatic actuation of hardware systems High redditivity rate NPV and IRR WIN-WIN solution 14

Target verticals Retail Airports Office Venues Public Administration target building spends > 100k /yr in heating & cooling seeking partnerships with real estate companies and utilities 15

16 Enerbrain s Customers

Case Study 8 Gallery Mall Torino, Italy 35% Energy Saving 30.000 2 sqm Days installation 17 100% Comfort

High level of air quality degradation due to visitors During peak hours in the food court CO 2 levels reached 2.000ppm because of manual management of air circulation 18

Air quality improvement thanks to Enerbrain Air circulation is automatically managed below law limits by Enerbrain Indoor temperature variations during lunch are offset by Enerbrain Limit 900 [ppm] 19

Over 35% energy savings, all seasons Thermal energy consumption before and after Enerbrain 20 Savings calculated according to UNI EN 15603

Case Study Autogrill Restaurant + Retail Ceriale, Italy 21 31% Energy Saving 1.000 4 sqm Hours installation 100% Comfort

No more waste due to manual HVAC management Pre Enerbrain Post Enerbrain Hourly T measurements during one week 22

Improved air circulation during peak hour Daily and weekly CO 2 measurements Pre Enerbrain Post Enerbrain 23

Improved time in comfort thanks to Enerbrain Hourly comfort monitoring during a week (7days x 24h, T and CO 2 ) Pre Enerbrain Post Enerbrain * 19% time in comfort 99% time in comfort 24 * Comfort zone: 21 +/- 2 < 900ppm

Enerbrain: Team, Partners, Press & Awards TEAM PARTNERS PRESS AWARDS 25

Giuseppe Giordano Founder & CEO www.enerbrain.com 26 Your innovation partner for a sustainable future

2 727 Technical details

28 Plug & Play integration with any HVAC system

Safety first: why we are different TESTED CE and ROHS compliant Each device passes 3 different tests in different locations Each SW release is thoroughly tested live before rollout FAILSAFE enode is electrically bypassed by a built-in switch in case of failure or maintenance: HVAC still works without Enerbrain Our cloud and services rely on leading service providers for safety, reliability & performance ENCRYPTED End-to-end encrypted communication via LTE/3G using any provider available Thanks to private connection services our IoT system is not exposing data to the Internet 29

How seasonal temperature affects energy usage 20 C Indoor Target T <20 C Outdoor Avg T Heating needed 20 C Outdoor Avg T Very Low Energy Usage >20 C Outdoor Avg T Cooling needed Heating Degree Days measure the T difference between outdoor and the indoor target of 20 C 30 Summer Indoor Target is 26 C. Reference values vary from countries.

Savings calculated according with UNI EN 15603 Savings = Consumption from Baseline Actual Consumption Past Consumption Baseline = average of Past Degree Days Example of Savings and Baseline calculation based on two years of past consumptions If actual HDD= 2500, and actual consumptions = 70000 kwh Consumption from Baseline = 40,2 kwh/hdd * 2500 HDD = 100.500 kwh 31 Savings = 100.500-70.000= 30.500 kwh ~30%

From global consumption to HVAC Heating monthly fossil fuel usage (MWh) Cooling & Ventilation monthly electricity usage (MWh) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Hot Water Heating HDD (weather) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Lights & others Ventilation Cooling CDD (Weather) Bill auditing & seasonal weather allow us to identify the energy used for HVAC 32 The baseline is always approved by the client and can be updated if there are changes to the building or its use by switching Energy Cloud on/off for a few days

Compatibility: why we are different What s missing: truly smart HVAC control 3 STEPS INSTALLATION Replacing your equipment or hacking the BMS is not the way to go because: BMS communication protocols are unsafe, closed and many. It s expensive and lengthy The BMS collects little data from old sensors We integrate to your HVAC with IoT devices By making your HVAC actuators connected, Energy Cloud can control them in real time to set temperature, humidity, ventilation while monitoring energy usage and system status. The actuators - still connected to the BMS - will take the input from Energy Cloud anytime it s possible to maximize savings and comfort. 33

Winning vs competition 100% compatible V Big Companies Small Companies Esco Quick Installation V No changes to the system V V Reports and maintenance SW and HW V V V Portfolio buildings management V V V 34

Enerbrain Step by Step An agreement founded on EPC model of sharing benefits 1. 2. 3. 4. Technical inspection, data collection and bill and portfolio audit 24 months Energy Performance Contract, installation in 45 days Installation on site and remote commissioning à Immediate saving Automatic renewal from Y3 Enerbrain Investments: Assessment + Hardware + Installation + Energy Cloud License + Connectivity + System Management + Maintenance + Insurance + Upgrades 35

3 636 Your innovation partner for a sustainable future