adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI

Similar documents
FOLDING CONTAINER HOUSE: AMH-4000 SERIES GENERAL AMH-4120 DIMENSIONS AND WEIGHT PICTURES:

MODULAR SOLUTIONS. Commercial Registration No /1 Branch of Abela Qatar International, Limited Liability Co. with Capital of QR 1,000,000.

Technical Description For MK-CTX Office Cabins

EXPANDABLE DWELLING SYSTEM FOR CHEAP AND FAST ERECTION AND DISMANTLING

DALAL FLAT PACK MODULAR UNITS

MSP Modular Building System

FLAT PACK SANDWICH PANEL SYSTEM ROCKWOOL DEMONTABLE ACCOMMODATION UNITS

ECOCASITA PLUS63. Drawings. Outside elevation example. Ground floor plan example. Page 1 of 27

FLEXING THE BOUNDARIES OF TEMPORARY SPACE

Worker camp sample. In this presentation Geiger International shows two kinds of building structures, for 200 worker.

Delta Level 1000 Hinged Lip Pit Mounted & Suspended Frame Dock Leveller

PREFAB HOUSES EZ-GROUP

Via Parque Alicante BUILDING SPECIFICATIONS

PND Training Hall Conex Building, Kabul ABSTRACT OF COST

Series ESK / ESB. Cabinets in Modular Design. Manufacturing Program: ESK-20 ESK-40 ESK-80 ESB Sandwich construction 20 mm, 40 mm and 80 mm

OUR SPARK PRE FAB INSULATED CONTAINER SIZES, PRICES AND LAYOUTS

AKASH ENTERPRISE INTRODUCTION: COMPANY PROFILE: PRODUCT ACKNOWLEDGEMENT:

Demonstration building

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

MODULAR DEMOUNTABLE CONTAINER BUILDING SYSTEM TECHNICAL SPECIFICATIONS

Saraswathi. Floor Plans

Protective devices according to EN ISO 12100

SolarStyl BIPV New Building Integrated Photovoltaic System August V13 Page 0

Sheet Metal Protective Films

Due to a depreciating Aussie dollar and increase in local steel prices our pricing will change on October 1 st.

Industrial Doors. Hangar Doors. Sliding Type

Contract with us before 31 January 2012 and be eligible to receive the $10,000 QLD Building Boost Grant

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Page 5/15/2018. Web: Tel: (02)

HEAVY STEEL CONSTRUCTION

ISO 20FT MOBILE FIELD WORKSHOP SHELTER

Series 3000 Pocket Doors

The Alcalá Residential Development combines the peace and quiet of a residential area with the convenience of living in the city.

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

Burlington Model at Country Hills Estates

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

GREENHOUSE ENGINEERING PREFABRICATED HOUSES

GENERAL MECHANICAL SYSTEM REQUIREMENTS

SECTION The specification section is organized by placing information in three standard parts:

the constant partition A partition made-to-measure, adjustable with an accurary to within one millimetre to any building grid.

E. Fume hood to have set baffling system. No adjustable baffles allowed.

BLUEKIT VENTILATION FLAPS

ESSENTIAL TECHNICAL SPECIFICATIONS.

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES

modular scaffolding R+

Pulsar. The panels feature a very interesting construction: modern welding units, Radiant Panels

1. Division 01: Administrative, procedural, and temporary work requirements.

Operable / Fixed Skylight Milgard Aluminum Window

UBC Technical Guidelines Section Edition Audio-Video Infrastructure Page 1 of 5

Cold Rooms Kide

Stack Parking Surface Mounted Stackers

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS

Ventura Office Partitions. Technical guide

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Build Options The Allrounder can be built DIY or let us do it for you. We offer 2 main build options and can customise our service to meet your needs.

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

ALARIS CONSOLE ABOUT ALARIS CONSOLE ALARIS CONSOLE FEATURES. Product Specification Document Date Published: September 17, 2004

VAULT. VIntegrated Storage and Filing wall

IRON AND STEEL PRODUCTS

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Cheshire, CT. By: A.M. Napolitano, LLC. Project Manager: Carolyne Sakonchick Ext. 323

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

About TSSC. Flat Pack Containers. Prefabricated Buildings. Light Steel Buildings. Security Cabins

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

.1 Section Documents and samples to be submitted..2 Section Construction and demolition waste management and disposal.

Product Datasheet. Hydraulic Dock Leveller with Telescopic Lip (PT) Load capacity: 150 KN ANSI NORM. Contact:

BUILDING SPECIFICATIONS

TABLE OF CONTENTS Public Safety Building

MODULAR CONTAINER HOUSES

General Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours

Cabin Specifications:

Waterfront. Floor Plans

THERMAL SOUND & FIRE INSULATION

SPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work

PRM/KA/RERA/1251/446/PR/171230/002141

Soundmaster & Modernfold TECHNICAL DATA

Product Guide Specification

FALSE CEILING SYSTEM CLADDING SYSTEM FLEXIBITY PANEL ASSEMBLY CEILING ASSEMBLY QUALITY VERTICAL JOINT FLOOR SKIRTING TIME AND COST CONTROL 2 /8

Edificio Puerto Príncipe Pza. de Las Américas,

M I N I C O L D R O O M TECHNICAL SPECIFICATIONS

Modular Systems in Shipbuilding

MICRO-PS CLEANROOMS PARTITION SYSTEM

MODULAR HOUSES MAIN PRODUCT LINES. Traditional Prefabricated Houses

Melhart Music Center Modular Music Practice Rooms - E3 Ready Specifications Section 13034

Storage space in steel. Storage Space in Steel. From the market leader!

Bioclimatic Pergola with ajustable blades

ELVORON STELLA HOME ELEVATOR

ELVORON LU/LA ELEVATOR

Residencial Vila Park - "Viviendas desde *. Plaza y Trastero Incluido" Avda. Mestral s/n,

Product Guide Specification

Type II Environmental Declaration according ISO 14021:2001/A1:2011

TABLE OF CONTENT. Equipment kit Description of the technology Installation of equipment Start of construction...

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS

SECTION SECTIONAL OVERHEAD DOORS

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Transcription:

The accurate study of the proportions and modularity, led us to design a elementary module from the standard dimensions of around 2,5 x 5,5 x 3 meters. All modules are designed for minimal waste of space and with dimensions for optimal transport. This allows a wide possibility of aggregation and even to customize the final shape of the building. adaptable

+ transportable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI

The concept which stand at the base of the elementary module is also environmentally friendly because involves the reuse of shipping containers. The use of a modular base, make possible infinite number of combinations and variations, allowing an infinite expansion. 20 module (shipping container) and proportional diagram demonstrating standard modular relationships.

DIMENSION Living 8 sq.m Kitchen 5 sq.m Bathroom 3,5 sq.m Master bedroom 13 sq.m modulable 1 Level 30 sq.m house

DIMENSION Living 13 sq.m Kitchen 5 sq.m Bathroom 3,5 sq.m Master bedroom 13 sq.m Bedroom 10 sq.m modulable 1 Level 50 sq.m house

DIMENSION Living 16 sq.m Kitchen 7 sq.m Bathroom 3,5 sq.m Master bedroom 13 sq.m Bedroom 12 sq.m modulable 4 Level 50 sq.m block apartments

DIMENSION Lv.0 Living 18 sq.m Kitchen 11 sq.m Bathroom 4 sq.m Master bedroom 17 sq.m modulable 2 Level 80 sq.m house DIMENSION Lv.1 Bedroom 11 sq.m Bedroom 14 sq.m Terrace 30 sq.m

modulable 2 Level 80 sq.m house 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI

The whole project has been designed to make energetically autonomous each installation. For this reason, the methods used in the design take into account different climatic conditions and adaptability of the modules. S u sustainable

The basic concept is that of an integrated energy system capable of "self-sustaining": the energy requirement is satisfied by the installation of the house. Integration into the home of a modern energy system, in which the motor is the clean and renewable energy. Integrated systems to increase energy efficiency and reduce water consumption to minimize waste. sustainable

We uses customized, tested and certified high cube ISO light steel structural modules for dwellings. SINGULAR MODULE MEASUREMENTS: 20 foot High Cube ISO LIGHT STEEL MODULE 20 (L) x 8 (W) x 9-6 (H) 6096 mm (l) x 2438 mm (w) x 2896 mm (h) ISO LIGHT STEEL SHIPPING MODULE BUILDING FOOTPRINT Dimensions: 16 x 20 / 4877 mm x 6096 mm Area: 320 ft2 / 30 m2 GROSS FLOOR AREA 320 ft2 / 30 m2 OUR STANDARD MEASUREMENTS: ROOF AREA 320 ft2 / 30 m2 BUILDING HEIGHT (EXCLUDES FOUNDATION HEIGHT) 9-6 / 2896 mm BUILDING CODE COMPLIANCE Our housing units are built in compliance with the following codes: IBC (international building code) 2010 International residential code International energy conservation code International fire code International electrical code International plumbing code International mechanical code technical detail

technical detail 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI CONTAINER HOUSE COST-EFFICIENT, EXPANDABLE, TRANSPORTABLE GENERAL The standard container for various purposes is suitable for international container transport. It is made of appropriate external dimensions and has connections for lifting and fixing or compounding. The container is designed as a light construction consisting of floor and roof frames and corner profiles. The construction enables compounding of individual containers in longitudinal and transverse directions without limits. DELIVERY: Containers can be delivered assembled or individually in kits 650 mm high. 4 kits can be bundled in packages 2591 mm high (ISO dimensions) DIMENSIONS and TARE (ISO Standard 1161) o External length 20 / (inner length) 20: 6.055m / (5.851m) o External width / (inner width): 2.435m / (2.231m) o External height / inner height: 2.790m / (2.510m) o Tare: 1950 Kgs STEEL FRAMEWORK o MATERIAL: cold formed steel profiles in a thickness of 3 to 4mm (bottom rails). o SURFACE WORKING: electric galvanization min 15 µm, zinc compatible epoxy ground coat in a thickness of 30µm, final zinc compatible vinyl acrylic coat in a thickness of 60-70µm. o FITTINGS : 8 comer fittings (dimensions according to ISO standard 1161), rainwater pipe in the roof framework, plate thickness of 10mm excluding top corner fittings of the top kit of each bundle (20mm thickness) o FORKLIFT OPENINGS: openings for fork-lift pockets in the floor framework, dim 88 250mm in a distance of 1200mm

technical detail 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI FLOOR o COMPOSITION: EXTERNAL WAINSCOT: flat galvanized steel sheet metal in a thickness of 0.5mm. INSULATION FILLING: non combustible mineral wool in a thickness of 100 mm among steel transverse supports. MINERAL WOOL DENSITY: 60 Kg/m3 STEAM BLOCKADE: PE foil in a thickness of 80µm PLYWOOD PANEL in a thickness of 18mm. o PERMITTED LOADING : 2.50 KN/m2 o COEFFICIENT OF THERMAL CONDUCTIVITY: l=0.039 W/mK o THERMAL RESISTANCE: 2.56 m2k/w o INSULATION OPTION: It is possible to choose an alternative insulation filling; extruded polystyrene (XPS) in a thickness of 80 mm XPS DENSITY: 35 kgs/cubic meter COEFFICIENT OF THERMAL CONDUCTIVITY: l=0.029 W/ mk THERMAL RESISTANCE: 2.76 m2k/w CEILING o COMPOSITION: external wainscot: flat galvanized and painted steel sheet metal in a thickness of 0.5mm. insulation filling: noncombustible mineral wool in a thickness of 100mm among plywood purlins. Mineral wool density: 60 Kg/m3 steam blockade: PE foil in a thickness of 80µm inner wainscot: chip wood panel in a thickness of 9 mm with a foil in white color; joining of chip wood panels with PVC profiles o METEOR WATER OUTLET: 4 each of PVC rainwater pipes, diameter 50mm in corner pillars o PERMITTED LOADING: 1.50 KN/m² o COEFFICIENT OF THERMAL CONDUCTIVITY: l=0.039 W/mK o THERMAL RESISTANCE : 2.56 m2k/w

FACADE WALLS SIDE PANELS WIDTH: 1145mm; total panel thickness: 70mm. Five panels fit into the long side and two panels fit into the short side of container and they are fully interchangeable. o COMPOSITION: o EXTERNAL WAINSCOT: galvanized and painted steel sheet metal in a thickness of 0.5mm. o INSULATION FILLING: non-combustible mineral wool in a thickness of 50mm in the wood framework. Mineral wool density: 60 Kg/m3 o INNER WAINSCOT: chip wood panel in a thickness of 9 mm with a foil in wood pattern (bright oak or white). o Joining of panels with PVC profiles. Final elements in the interior are made of chip wood panel in a thickness 8mm with a foil in wood pattern. o PERMITTED LOADING: 1.00 KN/m² o COEFFICIENT OF THERMAL CONDUCTIVITY: l=0.039 W/mK o THERMAL RESISTANCE :1.28 m2k/w o 100 MM INSULATION OPTION: The framework can be modified so that mineral wool insulation reaches a thickness of 100mm. In this case the thermal resistance goes up to: 2.56 m2k/w. Note: 100 mm thick wall panels are not fully interchangeable like standard 50 mm ones DOORS Standard external door, single fold, 40mm thick, made of: o a frame in pre-painted aluminum o hot galvanized and pre-painted steel sheets (inside and outside) o insulated with PL (polystyrene) o opening dimensions of 808 2030mm. o net opening dimensions: 754 x 1985 mm. o 845 x 2000 mm net opening is available technical detail

WINDOWS technical detail o Option 1: made of PVC, white color, dimensions 800 1100mm, glazed with double layer glass in a thickness of 4/15/4mm, with sliding mechanism (one side fixed and one sliding) o Option 2: made of PVC, white color, with dimensions 800 1100mm, glazed with double layer glass in a thickness of 4/15/4mm, with tilt and swing mechanism o Option 3: made of PVC, white color, with dimensions 800 1200mm, glazed with double layer glass in a thickness of 4/15/4mm, with tilt and swing mechanism ROLLING SHUTTERS o Option 1: external PVC rolling shutters in PVC guides. o Option 2: external Aluminum rolling shutters without insulation in Aluminum guides. o Option 3: external Aluminum rolling shutters with insulation in Aluminum guides. ELECTRICAL INSTALLATIONS o Standard: CE regulations o Voltage: 220 V, 60 Hz single phase o Network connections: CEE-connection plus/socket, 3-pole 32 A, 220V, o Inner distribution system: BVVB cables of suitable dimensions (6, 2.5, 1.5 mm),ce marked, flush-mounted. All cables (located on the ceiling and inside wall panels) run into CE certified plastic conduits. Roof cables and panel cables are connected with CE compliant jacks. All jack connections are protected inside CE marked and IP44 rated distribution boxes. o Protection: protective current switch (40/2E-0,03A), automatic fuses (B-characteristics) of suitable power (10A, 16A) o Earthing: galvanized connector with a steel plate of dimensions 30x80mm welded on the bottom frame.

PREFAB FLAT-PACK OFFICE/LIVING ROOM / CONTAINER HOUSE o o o o EASY INSTALLATION ENVIRONMENTAL HIGH QUALITY TIME & COST SAVING MAIN STRUCTURE Steel chassis and frame/sandwiched color steel plate DIMENSION internal: L 5.620 X W 2.120 X H 2.280 mm FRAME Steel structure FLOOR Steel structure; leather floor WALL Double side sandwich ROOF Galvanized steel plate; insulation layer; mineral wool DOOR Aluminum alloy WINDOW Plastic; Steel; aluminum alloy with shutter; push-pull / sliding ELECTRICITY One 12 way distribution box; lamps; one switch; 2 plugs; customer standards OPTIONAL Plumping; kitchen cabinet; bathrooms accessories; furniture; etc technical detail technical detail

technical detai

+39 / 011 19 32 39 70 +39 / 331 38 44 047 info@dp-group.org maurizio.devito enrico.damasio D&P Group SRL office: Headquarters: Legal head office: Largo Vittorio Emanuele II nr 82-10121 Torino - Italy Corso Re Umberto 5 bis 10121 Torino - Italy amministrazione@dp-group.org P.I.10906000012 Cap.Soc.10.000,00 R.E.A 1171243 Registro Imprese 35606800