Jet Tunnel Fans.

Similar documents
Design of Ventilation for a Highway Tunnel in a Very Crowded Urban Area

Tunnel Ventilation System Design and Air Quality. Peter Gehrke and Andrew Purchase

Global Leaders in Tunnel Ventilation

GreenPark. Configurable Car Park Solutions

Facilitator Base. Helps you to choose the best product for a given application

Tunnel Ventilation Technology by MRT TEAM

Fans for Tunnel Ventilation

SECTION EXHAUST FANS PART 1 GENERAL

MANUFACTURING DIVISION

It s All a Matter of TechNiQ. NiQ: Our latest generation of energy-saving motors.

EC medium pressure axial fans.

VEHICULAR TUNNEL VENTILATION DESIGN AND APPLICATION OF CFD

AIR TECHNOLOGY SOLUTIONS FOR DEMANDING APPLICATIONS. Product overview.

ufive Fans and Business units

Louvers and Dampers April Product Guide Specification SECTION SMOKE DAMPERS

Precise Air Management Product Range > Car Park Ventilation

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

3363 en / e

Fans for Petrochemical Industry The next generation of technology

Plug Fans with EC motor

MS/MSN Marine Single Suction Pump

Project No

LSA Rating Table Low Voltage Alternators - 4 pole

Central Station Air Handler Specification

lindab we simplify construction LindabAirMovement Product overview Fan Assortment

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics

The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1.

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

KURORTNY AVENUE RELIEF ROAD IN SOCHI

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

660 Volts 630 & 800AMP

EC medium pressure axial fans. The efficient system solution.

Lenntech. Tel Fax / Marley MS Cooling Tower /

Capital Projects Group Air Terminal Units Specification

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information

SECTION AIR-TO-AIR ENERGY RECOVERY EQUIPMENT

Each furnace has an independent 8 segment programmable controller and each has over-temperature protection and RS232 communications.

SUGGESTED SPECIFICATIONS Pump Frames through 64132

Dyno Test Rooms Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market

MoffittVent. Large Natural Ventilator. MoffittCorp.com (800) th Ave S. Suite 130 Jacksonville Beach, FL 32250

SEISMIC RESTRAINT SYSTEM

1.02 Related Sections A. Section Heating, Ventilation and Air Conditioning (HVAC). C. Section Pneumatic and Electric Control HVAC.

GOULDS PUMPS. Commercial Water. e-sv General Market Specifications. Applications. Specifications

All product images are indicative only General characteristics

NV series. Induction VAV air volume control terminals

EFFECTIVE THRUST TRANSFORMATION INSIDE TUNNELS WITH JET FANS (BANANA JET)

Ambient Air Quality Monitoring Update, Kirby Misperton A Wellsite, KM8 Production Well

Room protection nozzles

Air quality in the vicinity of a governmental school in Kuwait

RPM & RPMF Rotor Impact Mill. The Sand Maker

3456 en / c. 1 to 20 MW Land and offshore applications

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

A Twin City Fan Company COMPANYPROFILE

Mechanical vibration Evaluation of machine vibration by measurements on non-rotating parts. Part 8: Reciprocating compressor systems

AirBench EX Operation and Maintenance

NOZZLES NOZZLES NOZZLES

AIRIUS AIR PEAR THERMAL EQUALISER SOUND POWER LEVEL COMPARISONS

AMX - GG PUMP RANGE. Part of the MAGNETIC DRIVE Pump Range AMX-GG OVERVIEW REDUCED LIFE CYCLE COST HIGH EFFICIENCY DESIGN PLASTIC MAGNETIC DRIVE PUMPS

CONCRETE WEIGHBRIDGE. SBP/CO model

NUCLEAR POWER CORPORATION OF INDIA LTD TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 REV NO : 0 DATA SHEET A

PRODUCT SPECIFICATION GUIDE MODEL EQB BELT DRIVEN MIXED FLOW INLINE FAN FACILITY SERVICES SUBGROUP: DIVISION 23 SECTION

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

50948-RHN Putney. Friday, 15 December This document includes: Code Section Revision Dated

PROTEC. High temperature. low voltage electrical material

NEW. FR90 fire dampers. Maintenance-free

SECTION AIR DISTRIBUTION

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

V MW. One turbine for one world. vestas.com

High Performance Wind Turbine

Innovative Low Head Hydro The StreamDiver in Action. NWHA Small Hydro Workshop 2016, Wenatchee, WA USA

LVH-A Series Intumescent Fire Dampers Alternative Mounted Systems 1, 2 & 4 hour Fire Rating

SUSTAINABLE VENTILATION Lessons from the upcoming World Road Association report

Self-Priming pumps, when it really matters

V MW. High energy production for low wind sites. vestas.com

ThermoKey Every detail, even the smallest one, is designed to achieve the best Dry Cooler solution which meets the customer needs.

Jennings O Donovan & Partners Consulting Engineers Sligo

Fixed Blade Weather Louvre

EHH-601D. Miami-Dade Qualified Wind-Driven Rain Louver

Series Sump and Sewage Systems

Ventilation and Exhaust Purification of Motor Vehicle Tunnels in Japan

The following document can be provided to an Engineer, Contractor, or Owner to allow them to properly specify MESAN s MXR-KM series Cooling Towers.

Company profile WORKING FOR AN ESSENTIAL RESOURCE MEANS TAKING CARE OF THE FUTURE. w w w. r o v a t t i. i t

Air Compressor Series.

Cooke Industries - Phone: Fax: Web:

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION

NPSH S TRAINER PTC CORROSION RESISTANT IEC close-coupled BASEPLATE in-line MACHINED TENSI

special needs surface trajectory costs. High Efficiency 3. 4.

SUGGESTED SPECIFICATIONS

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

V MW. One turbine for one world. vestas.com

Are you looking for the maximum return on your investment in wind energy?

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

Standard Pole Range 5. In-Ground Mounted 6. Ground Line Protection 6. Base Plate Mounted 6. Quality & Design Standards 7. Quality Standard 7

CombiSump. Vertical long shaft sump pump,according to ISO 2858,EN 733 (DIN 24255), API 610

Addendum 1 Section THERMAL INSULATION FOR PIPING Burrow Avenue Pumping Station Upgrades Page 1 of 5

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTG. Vertical Turbine Generator

Industrial Silos. World class quality, unbeatable value.

Technical data sheet Number 04 / updated November 2008

SECTION AIR OUTLETS AND INLETS

Transcription:

Jet Tunnel Fans www.systemair.de by

Division AJ (T) Tunnel Jet Fans Standard features: Thrust efficiency in excess of 40 N/kW Adjustable aluminium impellers for maximum efficiency Terminal box on the casing for easy on-site wiring IEC standard motors as specified in IEC 34; high temperature motors for smoke removal Motors can be supplied to suit 50 Hz and 60 Hz supplies. Standard bearings are sealed for life, extended lubricators as an option Unidirectional or fully reversible in either direction The Systemair Matthews & Yates Division has been involved with specialist fan engineering in tunnel ventilation for more than 25 years. A number of important references all over the world prove our competence. Depending on the tunnel design, size and traffic flow, various solutions for ventilation are available. These are generally: a) Fully Transverse Air is supplied from one side of the tunnel and extracted from the other, picking up fumes in the process. Most suited to long tunnels but costly due to the large sized ducts required. b) Semi Transverse Fresh air is supplied uniformly over the length of the tunnel causing the foul air to escape longitudinally from the tunnel. Semi transverse ventilation systems use ducting for supply and often in conjunction with jet fans for certain sensitive areas. c) Longitudinal Widely accepted as the most economical of the three systems and normally used for tunnels up to approximately 1 km in length, depending on traffic flow. Jet fans mounted in the tunnel roof will provide positive longitudinal ventilation and have the ability for reversal in emergencies or to work with prevailing winds. The number and size of fans depends on the maximum air flow required to maintain the level of carbon monoxide and diesel smoke at acceptable levels. The complete design and manufacture of the entire range is backed Types of Tunnel Design Cut & Cover Tunnel up by the latest resources including CAD/CAM systems and CFD software in accordance with AMCA. Quality is to the highest international standard and we are fully certified to ISO 9001. EN 12101-3 certification is in progress. Ring Road Tunnel Circular Tunnel 24

Sturdy casing Casings are heavy gauge, hot dip galvanized upon completion, with spun flanges for high rigidity. Additionally painted or in stainless steel as an option. Silencers are offered with standard length 1 x fan diameter. Other lengths are available on request. Quality Systemair is ISO 9001: 2000 approved. The Systemair quality is regularly monitored by TÜV Süd. Warranty Systemair offers a three year warranty on all AJ (T) fan models. The Systemair warranty conditions apply. Motors Standard or high temperature motors for periods of 1 or 2 hours at temperatures of 250 C, 300 C or as may be specified in the design of the tunnel. Accessories Drop rods for fixing to tunnel ceiling that will suit the customer's requirements. Anti-vibration-hangers to suit the degree of isolation required. Ordering code AJ 1000-10 / 22-4 (T...) Temperature class 4-pole motor Pitch angle Number of blades Impeller diameter Jet tunnel fan TYPICAL CAPACITIES AVAILABLE Jet Fan Size mm Max. Thrust N Max. Motor Power kw Motor Speed rpm (50Hz) Max. Velocity m/s 500 235 6,5 2880 31,1 560 360 13,5 2880 33,3 630 640 27,0 2880 42,0 710 950 40,0 2880 42,9 800 452 13,0 1440 13,9 900 725 25,0 1440 30,3 1000 1100 35,0 1440 35,3 1120 1690 65,0 1440 37,8 1250 2110 75,0 1440 39,6 1400 1766 50,0 960 30,9 1600 1989 50,0 960 30,2 The above details are for Uni-Directional jet fans. Truly Reversible jet fans will give approximately 5% lower thrust than those shown in the table. 25

Division Tunnel Jet Fans Jet Fans provide Ventilation which reduces the Carbon Monoxide (CO) to acceptable levels and cover all other likely pollutants generated by petrol engines, i.e. nitric oxide (NO), nitrogen dioxide (NO2), sulphur dioxide (SO2). Jet Fans can limit the concentration of CO (in parts per million by volume) to suit requirements i.e. 250 parts/mill: Extreme traffic conditions 150 parts/mill: Peak traffic flow 100 parts/mill: Off peak traffic flow (this is the maximum exposure for full time tunnel staff). With diesel-engined traffic the exhaust smoke affects visibility within the tunnel and is the limiting factor rather than CO. Visibility levels (Diesel smoke particles per cubic metre of air) are normally defined as follows: 1 Dmg/m³: clear for practical purposes 9 Dmg/m³: visibility very poor, traffic must move slowly. Thrust Measurement Continuous research and development is our major consideration and our goal is to satisfy worldwide demand for our ventilation products. Jet fan measurements are carried out in accordance with ISO 13350. To further develop our jet fan technology and for customers witness testing, a new rig was commissioned to the latest international standards. This accurately determines the actual thrust by the suspended configuration method. Incorporated within the rig is an adjustable position transducer measuring system. High temperature smoke spill testing is carried out to satisfy the wide range of demands for our export markets. Testing to the EN 12101-3 is in progress. 26

ROAD TUNNEL INFORMATION REQUEST Please provide the following information (if available) Tunnel Length (m) Cross Sectional Area (m²) Hydraulic Diameter (m) Dimensions / Drawing Number of Lanes c Flow (Uni-directional or Bi-directional) Type of Wall Construction (Rough or Smooth) Altitude Above Sea Level (m) Tunnel Gradient (Slope) Wind Velocity Outside Tunnel (m/s) Tunnel Location (Urban or Rural) Number of Vehicles Using Tunnel (per hour, per day) Ratio of Cars to Heavy Goods Vehicles (%) Design Size of Fire (MW) Year of Tunnel Opening For the purposes of calculation. If any of the following are not known, then those from PIARC (1995) will be used. Concentration of CO (ppm) Concentration of NO 2 (ppm) Concentration of Smoke (ppm) Average of CO Emissions (ppm) Average of NO 2 Emissions (ppm) Ambient Temperature Levels ( C) Please provide any further details that may be available and could be of assistance in relation to the tunnel design. 27