Corrosion protection systems for any application

Similar documents
Compendium of finishes

Technical data sheet Spectral UNDER 385 Two-component epoxy primer RELATED PRODUCTS

Technical data sheet PROTECT 360 Anti-corrosion epoxy primer Fast drying epoxy anti-corrosion primer hardened with amine adduct RELATED PRODUCTS H5950

POWDER COATINGS- GENERAL SPECIFICATIONS

Technical Data Sheet EPOXY PRIMER 3:1 Anti-corrosion epoxy primer RELATED PRODUCTS. Epoxy primer hardener EPOXY PRIMER HARDENER PROPERTIES

E-Xtreme. Titanium plasma protected. E-Xtreme hours in salt spray tests. series. iwww.ilme.com

Pc-Coat. Duplex coating

State-of-the-art paint plant

Technical data sheet Spectral UNDER 325 Two-component acrylic filler RELATED PRODUCTS. acrylic thinners

Coating Specifications

Nylofor Swing Gate. Figure 1: Single Nylofor Swing Gate

Sapa Surface Treatments. Anodising, powder coating and Decoral

Technical Specification for Galvanised Fabricated Steelwork

Generic Product Index

Technical Information Sheet

TECHNICAL DESCRIPTION OF A MULLION/TRANSOM WALL OF MB-SR50 EI SYSTEM

80/90/100/120/mm POST Standard Medium Heavy Extra Heavy

complete with pallet support bars, column guards, safety barriers, pallet back stopper painting

Product Data Sheet AkzoNobel Powder Coatings Interpon APP 120 (EL140G)

P R O D U C T D E S C R I P T I O N

Binding protection at different levels

M.K.Plastics Coatings Fiberglass Characteristics & Corrosion Resistance Guide

Technical data sheet Spectral UNDER 335 Two-component acrylic filler RELATED PRODUCTS. acrylic thinners

IMRON MARINE DP4101/DP4104 HS Primer

Photo: Salzgitter Mannesmann Grossrohr GmbH. Photo: Salzgitter Mannesmann Grossrohr GmbH

FAST drying products for steel structures

Colourthane C-Series. Metal Coatings Guide

Chapter 7 APPROVAL OF COATINGS

AK40 PRIMER ACRILICO HS Two-component acrylic monolayer primer

Epoxy resin MIO + polyurethane

two component polyamide cured epoxy primer yellow/green - eggshell

CORROSION PROTECTION HEAVY INDUSTRIAL MARINE POWER MINING BRIDGE STRUCTURES HARBOURS CHEMICAL PROCESSING PETROCHEMICAL WASTE WATER TREATMENT

TECHNICAL DATA SHEET 1051R / 1057R HIGH PRODUCTIVE SURFACER DESCRIPTION

1040R UNIVERSAL 2K PRIMER GREY

DEXION RACKING. The Product picture Effect of picture. 80/90/100/120/mm POST. Standard Medium Heavy Extra Heavy

HS+ Primer Filler P , P & P

two component polyamide cured epoxy primer yellow/green (redbrown on request) - eggshell

two component polyamide cured epoxy primer yellow/green (redbrown on request) - eggshell

3 Thermal range of application of the coated parts Continuous operational temperature range: JED to C to +80 C JED C to +120 C

Product Data Sheet. Suitable for electrostatic spray Specific gravity g/cm³ Storage

FUCHS Industrial Lubricants. For extra process reliability. Lubricants for cold forming

Moisture curing paint systems. (Moisture Curing Urethanes) MCU

Structuring Agents. Polymer powders to create haptic, visual and functional effects on surfaces.

1(5) Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.

Fast curing epoxy resins + polyurethane

Wind power energy is attractive as a clean energy source.

DP4101 / DP4104 / DP4107 HS PRIMER

Moisture curing paint systems. (Moisture Curing Urethanes) MCU

Novelis stands for excellent quality, with consistently reproducible products manufactured in our network of world-class Coil Coating facilities.

External Coating Chart

Standard Operating Procedure (SOP) Remech

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 25 C calculated IED (2010/75/EU) (theoretical)

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.

4970 PRIME COAT FZ Two components zinc phosphate epoxy product

TECHNICAL INFORMATION

Thermoplastic Coatings for Metal Protection and Corrosion Prevention of Lighting Columns. Gerry O Donnell - Technical Manager Plascoat Systems Ltd.

Hot Dip Galvanized Case Study No. 21 Eskom Coastal Sub-station

Property Test/Standard Description

CT ETCH PRIMERS 466-Line

Anticorrosive Coatings

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

LV360 Primer EP 2.1 FOR PROFESSIONAL USE ONLY

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation

Acronal PRO & Joncryl Water based Resins for Metal Protection

OUTLINE ATMOSPHERIC CORROSION INTEGRITY MANAGMENT

PRODUCT INFORMATION Dero Hoop Rack

NON-CLEANING AND OPTIMIZED FOR CORROSIVE ENVIRONMENTS. Hilti HIT-Z-F and HIT-HY 200 ultimate performance chemical anchor system

Richter Sealless Chemical Magnetic Drive Pumps

SECTION STEEL WINDOWS UL Labeled Fire-Rated Horizontal Slider (900) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

EX-408 PRIMERS for Australian Defence Force using

Fastening technology for metals and plastics

Technical Information

A reliable partner. Find out for yourself! is a company operating in the field of surface technology and mechanical processing.

Norlux. GmbH. Solar shading that works, and works, and keeps working... - external sun protection Sheet Metal Blades. Technical Specifications

Open to bring alive in technicolour

TECHNICAL DATA SHEET

Road Tunnel Fire Protection. with Alvenius Piping Systems

CANAL COMPACT & CANAL PLUS. powerful warmth, perfectly integrated

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 29 C IED (2010/75/EU) (calculated)

Cold trichloroethylene degreasing Film Thickness 70± 10 µm 10 minutes at 170 C (PZ 660 alone) 5 minutes 30 sec. at 220 (Maximum curing conditions)

Abcite 500. Technical Data and Application Guide. Product description. Typical applications. Product range. Product certifications.

Imron HydroClearCoat. 2K Waterbased Clearcoat PUR. Technical Data Sheet. Description

Complete Car Refinishing

Property Test/Standard Description

Eurovent Product Catalogue

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

QUALICOAT SPECIFICATIONS UPDATE SHEET No th Edition Page 1/15. Chapter 4 Approval of coatings

Product Data Sheet July 2017

Coatings for Electronics

APU 108 : Acryline Wet on Wet Epoxy Primer Surfacer

Unmatched Coating Performance! DRY BULK STORAGE

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C

- RUSTKLEEN. Characteristics Test Method Unit RUSTKLEEN

Technical Specification for Steel Forged Fittings

A Contract for Constructing a Building in Steel

Property Test/Standard Description

Sika offers the right solution for every task in any area.

Effective 15 July, 2010 LE2001 / LE2004 / LE2007 LOW EMISSION PRIMER PLUS

4 SPRINGS 6 SPRINGS 8 SPRINGS 10 SPRINGS 12 SPRINGS 14 SPRINGS

Technical Specification for Live Line Tap Connectors

Transcription:

Corrosion protection systems for any application 1

2

Fans need an excellent atmosphere or an excellent protection layer To prevent them from corrosion, we provide extra layers. Fans are not always exposed to a gentle atmosphere over their lifetime. Damage to the surface can occur caused by high temperatures, UV radiation, contact to abrasive material, or by mechanical impacts. We in Nicotra Gebhardt GmbH provide our products with layer by layer a protection against perishable actions. The higher the corrosion load, the more important is the protection layer. Especially high corrosion loads occur in the chemical industry or in coastal areas. A good corrosion protection will be essential in these places. But even in less aggressive areas corrosion may occur e.g. in places with higher industrial pollution. In any case a class of its own. We adapt solutions for different applications. Besides selecting corrosion-resistant construction materials (galvanised sheet steel, aluminium, stainless steel, or plastics) we offer a system consisting of 3 different classes of corrosion protection based on different coating materials. This system confirms: Nicotra Gebhardt GmbH is in a class of its own. 3

Every fan you receive from us provided with corrosion protection All fans in standard execution are already equipped with a basic corrosion protection by either using corrosionresistant materials or by receiving a basic layer of coating. This corrosion protection satisfies the need for longlasting material lifetime in most fan applications. If stronger requirements are demanded, an increased corrosion protection will be applied. Step-by-step corrosion-protected Nicotra Gebhardt GmbH fan Any corrosion protection system is only as good as the quality of the pretreatment! For this reason, all parts made by Nicotra Gebhardt GmbH to be coated are submitted to the following pretreatment processes: Zone 1: Intensive washing and degreasing, then full iron phosphating Zone 2: Rinsing process Zone 3: Clear rinsing with VE water Zone 4: Drying After this, the coating process is made. One of two different procedures may be applied: Electrostatic powder coating Wet lacquering 4

The electrostatic powder coating The epoxy-polyester mixed powder coating combines the features of epoxy and polyester. Excellent mechanical and chemical resistance are the advantages of this combination. The thermoplastic powder coating is recommended for cases where highest resistance, long life operation and increased surface quality are required. Also sound and electrical isolation features are added. Frequently required is this application of thermoplastic powder coating for tropical and subtropical areas. The wet lacquering unit One component synthetic enamel (1K) The 1K synthetic enamel provides an excellent chemical resistance. The mechanical stress resistance is high because the material keeps a certain flexibility when hardened. Two components acrylic lacquer (2K) The 2K acrylic lacquer provides an excellent resistance against mechanical stress and UV radiation. It resists against splash or condensation water and also against diluted acids and alkaline solutions. This coating fulfils the specifications concerning long lasting corrosion protection for industrial, ventilation and air treatment installations. Our High-Tec powder coating plant with bar code control and efficient power & free conveyors ensures that a continuous quality level in surface protection is met. Environmental control by optimised water and energy management. In both coating method the water is permanently treated in the pretreatment zones 1 to 3. Advantage: low need for fresh water and good environmental control. The drying plant as well is very energy-efficient using the waste heat of the powder polymerisation oven thus saving a lot of energy. Test procedures In order to assure the quality of the corrosion protection of our fans, they are submitted to special quality checks. The salt-water spray test to DIN 50 021 evaluates the layer quality in regard to the corrosion-inhibiting effect. The grid cutting method to DIN ISO 2409 evaluates the adhesive capacity of the coating. The impact test finally evaluates the resistance against mechanical shocks as they may occur during transport. Further options Welding seams As a standard, the welding on a fan casing and impeller is made discontinuously (stitch-welded). In order to increase the corrosion resistance and to avoid intergranular corrosion, when conveying wet or slightly aggressive media, the weld can be executed continuously (seam-welded). Detachable fixing elements of the shaft As a standard, all detachable fixing elements (screws, nuts and bolts, washers) in Nicotra Gebhardt GmbH are made of galvanised steel. Fan shafts are made of steel and protected by a Tectyle coating. For increased protection requirements, these elements can be made of stainless steel as an option. 5

Which corrosion protection class do you need? In standard HVAC installations and for AHU (air handling units) without special corrosion protection requirements, the standard execution of the fans will be sufficient. If higher corrosion loads are expected, the additional corrosion protection class S40, the increased protection class K90 or the premium protection class P100 will be adequate. For fans working in areas of high temperatures, we offer the class H execution. Without having further details, the subsequent criteria may only be understood as an indication. The final decision for a corrosion protection class has to be made by the end-user evaluating the conditions of operation of the fan. For operation in: - Buildings with varying temperatures - Fair air humidity conditions - Operation in open air, country or city site without major corrosion loads Additional corrosion protection Class S40 Powder coating L 2,000 W 1,400 H 1,600 mm, made of blank or galvanised steel and aluminium Epoxy-polyester powder mix Layer thickness M 40 µm For applications in: - High-value air-conditioning installations in hygienic execution - Laboratories, shelters, cooling towers - Installation outside at seaside or industrial areas - Air-conditioning installation in chemical or pharmaceutical industry Increase corrosion protection Class K90 Powder coating L 2,000 W 1,400 H 1,600 mm made of blank or galvanised steel and aluminium Epoxy-polyester powder mix Total layer thickness M 90 µm Wet lacquering L 2,000 W 1,400 H 1,600 mm made of blank steel 1x1-component primer (synthetic enamel primer alkydbased) 1x1-component lacquer finish (synthetic enamel) Total layer thickness M 40 µm L 2,000 W 1,400 H 1,600 mm made of steel and aluminium 1x2-component primer (polyacrylate/polyisocyanate) 1x1-component lacquer finish (synthetic enamel) Total layer thickness M 40 µm Wet lacquering L 2,000 W 1,400 H 1,600 mm made of blank steel 1x2-component primer (polyacrylate/polyisocyanate) 1x2-component lacquer finish (polyurethane) Total layer thickness M 90 µm L 2,000 W 1,400 H 1,600 mm made of galvanised steel and aluminium 1x2-component primer (polyacrylate/polyisocyanatet) 1x2-component lacquer finish (polyurethane) Total layer thickness M 90 µm For the classes S40, K90 and P100, the following corrosion protection improvement options can be additionally chosen (see also catalogues or price lists): Impeller blades continuously welded Casing inside or outside continuously welded Fan, shaft made of stainless steel 6 Fixing elements made of stainless steel

The subsequent criteria may serve as guidelines. The final decision for a corrosion protection class has to be made by the end-user evaluating the operating conditions of the fan. For operation at: - Ship building - Chemical industry, laboratories - Canal building and tunnel building - Air-conditioning - Environment with agressiven media - for highest corrosion protection Premium corrosion protection Class P100 For operation at: - High temperatures up to 500 C and relatively low corrosion load High temperature corrosion protection Class H Thermoplastic powder coating consisting of a single component. L 2,000 W 1,400 H 1,600 mm made of blank or galvanised steel and aluminium Thermoplastic powder coating Total layer thickness M 100 µm Colour RAL 7001 Wet lacquer primer For fans operating in a temperature range up to 500 C. The high-temperature primer can only be applied to fan components made of blank steel Degreasing Single-layer lacquering primer (silicone raisin) Colour RAL 7004 7

Nicotra Gebhardt GmbH Gebhardtstrasse 19-25 74638 Waldenburg, Germany Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-mail info@nicotra-gebhardt.com www.nicotra-gebhardt.com Nicotra Gebhardt S.p.A Via Modena, 18 24040 Ciserano - Loc. Zingonia (BG), Italy Phone +39 035 873 111 Fax +39 035 884 319 E-mail info@nicotra-gebhardt.com www.nicotra-gebhardt.com Perfect technology for perfect corrosion protection EN - CP2.3 PDF1-09.2010 8