Precise Thermometry for Next Generation LHC Superconducting Magnets

Similar documents
ON 19 September 2008, during powering tests of the main

Design and Manufacture of the Superconducting Bus-Bars for the LHC Main Magnets

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH Laboratory for Particle Physics RECENT DEVELOPMENTS AND QUALIFICATION OF CRYOGENIC HELIUM FLOW METERS

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN - ACCELERATORS AND TECHNOLOGY SECTOR

Quench Protection Study of a 11 T Nb 3 Sn Model Dipole for the High Luminosity LHC

METHODS FOR THE EVALUATION OF QUENCH TEMPERATURE PROFILES AND THEIR APPLICATION FOR LHC SUPERCONDUCTING SHORT DIPOLE MAGNETS

Thermal-Tab and Thermal-Ribbon Sensors

Fabrication and Test of a 3.7 m Long Support Structure for the LARP Nb 3 Sn Quadrupole Magnet LQS01

A High-Quality Platinum Resistance Thermometer to 661 C

The Optimal Passive Thermal Management Soldering and Electrically-Isolating Power Semiconductors to Within 33-micron (1.3 mil) of The Heat Sink

Solar Flat Plate Thermal Collector

The Role of Quench-back in the Passive Quench Protection of Uncoupled Solenoids in Series with and without Coil Sub-division

THE CRYOGENIC SYSTEM FOR THE LHC TEST STRING 2: DESIGN, COMMISSIONING AND OPERATION

Welding Processes. Consumable Electrode. Non-Consumable Electrode. High Energy Beam. Fusion Welding Processes. SMAW Shielded Metal Arc Welding

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Sensitivity of Nb 3 Sn Rutherford-type cables to transverse pressure

Temperature sensors for automotive applications

Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm

Earlier Lecture. In the earlier lecture, we have seen the importance of instrumentation in Cryogenic Engineering.

Current Status of the KSTAR TF Superconducting Magnet Development

2008 JINST 3 S Cryogenic system. Chapter Overview

CERN experience on accelerator magnets based on permanent magnets

CHARACTERISATION OF MAGNETIC SHIELDING MATERIAL FOR HL-LHC CRAB CAVITIES

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing

1. CERN Accelerator Complex 2. Decay Ring Magnets 3. Costing

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

CERN Conductor and Cable Development for the 11T Dipole

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH European Laboratory for Particle Physics CERN TS DEPARTMENT

Realization of ITS-90 from K through K: One Company s Approach

Critical Current versus Transverse Stress and Thermal Stability of a RRP Nb 3 Sn Rutherford Cable.

4 RESISTANCE THERMOMETRY

Quench Protection of Very Large, 50 GJ Class and High-temperature Superconductor Based Detector Magnets

ELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE

Pt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.

CRYOSAVER SUPERCONDUCTING LEAD INSTALLATION GUIDE

Agilent 4339B/4349B High Resistance Meters Technical Overview

Agilent 4339B/4349B High Resistance Meters Technical Overview

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

Sheet) Graphite Sheet

A NOVEL METHOD FOR THE IMPROVEMENT IN THERMOELECTRIC PROPERTY OF TIN OXIDE THIN FILMS AND ITS APPLICATION IN GAS SENSING

Summary of test results of MQXFS1 - the first short model 150 mm aperture Nb 3 Sn quadrupole for the High-Luminosity LHC upgrade

Specialised Hydrocarbon-based Grease for Cryogenic Applications

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

UNIT 5 High Energy Rate Forming (HERF) Processes

Operation of the Levitated Dipole Experiment Floating Coil

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

Item No.*9: 14T Cryogen Free System for measurement of physical properties:

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head

150 mm. 1/8 BSPP brass male compression fitting with locknut included

PLASTICS TODAY THE MAGAZINE OF PLASTICS MANUFACTURING PRODUCTIVITY

SURFACE TEMPERATURE SENSORS

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

Market Survey. Technical Description. Supply of Long Austenitic Steel Shells for D2 Dipole Cold Masses

CRYOGENICS AND LHC BEAM COMMISSIONING

Stud Welding. What is stud welding and how does it work? The 12 most important questions and answers

Mechanical behavior of a 16 T FCC dipole magnet during a quench

A Thermal Comparison of Power Device Mounting Technologies

ISO INTERNATIONAL STANDARD. Fire-resistance tests Elements of building construction Part 1: General requirements

Prospects of MgB 2 Superconductor in Energy and Magnet Applications

3M Cold Shrink Joint, SC145-II/SS145-II

PRELIMINARY. HTHA (Z1-Foil)

HTHA (Z1-Foil) Vishay Foil Resistors

Packaging Design for Lawrence Berkeley National Laboratory High Resistivity CCDs

CONTINUOUSLY TRANSPOSED CABLE

Fixed Resistors INSULATED ALUMINUM SUBSTRATES. Thermal Solutions for Hi Brightness LED Applications - Application Note

MEHRAN UNIVERSITY OF ENGINEERING AND TECHNOLOGY, JAMSHORO Sensors & Actuator for Automatic Systems LAB # 01 RESISTIVE TEMPERATURE TRANSDUCERS

HTHG* (Z1-Foil) Vishay Foil Resistors

B.0. Multipin Connector. Introduction

Jewelry Laser Spot Welding Machine

PRELIMINARY. HTH (Z1-Foil)

IPC Qualification and Performance Specification for Organic Multichip Module (MCM-L) Mounting and Interconnecting Structures IPC-6015

Nb3Sn Accelerator Magnets Insulation Review. Elwyn Baynham Simon Canfer Justin Greenhalgh CCLRC Rutherford Appleton Laboratory

CONDUCTION-COOLED 60 A RESISTIVE CURRENT LEADS FOR LHC DIPOLE CORRECTORS

curamik CERAMIC SUBSTRATES AMB technology Design Rules Version #04 (09/2015)

CRYOGENICS. MSN 506/Phys 580

Bonded Neo Magnetization Guide

Second stage cooling from a Cryomech PT415 cooler at second stage temperatures up to 300 K with cooling on the first-stage from 0 to 250 W

HEAT TRANSFER OF SEVERAL MATERIALS AT CRYOGENIC TEMPERATURE

Gold Wire Bondable Chip Resistor for Hybrid Circuits and High Temperature Applications up to +240 C, Long-Term Stability of 0.05%

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting

BUREAU OF INDIAN STANDARDS Draft Indian Standard

Stud Welding. What is stud welding and how does it work? The 12 most important questions and answers

User Manual. Version 1.0 THERMISTOR CHARACTERISTICS TRAINER. Model No : (ITB - 06ACE)

Detector Solenoid and Iron Structure

3M Electrically Conductive Adhesive Transfer Tape 9707

Wendelstein 7-X A technology step towards DEMO

HOS LOW OHM POWER RESISTORS. SERIES Size As per AEC-Q Open frame strip type. 2W to 5W. R001 to R05.

Study of Ion Beam Sputtering using Different Materials

Measurement Probe Brochures

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

LOW TEMPERATURE PHOTONIC SINTERING FOR PRINTED ELECTRONICS. Dr. Saad Ahmed XENON Corporation November 19, 2015

PRECISION BLACKBODY SOURCES FOR THERMOMETRY AND RADIOMETRY

Basic Properties and Application Examples of

Advances in Printing nano Cu and Using Existing Cu Based Manufacturing Processes. Michael J. Carmody Chief Scientist, Intrinsiq Materials

PRELIMINARY. FRSH Series (0603, 0805, 1206, 1506, 2010, 2512) (Z1-Foil) Vishay Foil Resistors

FRENIC4800VM5, a Water-Cooled High Capacity, High Voltage Inverter

Transcription:

1PoAP-01 1 Precise Thermometry for Next Generation LHC Superconducting Magnets V. Datskov 1, G. Kirby 1, L. Bottura 1, J.C. Perez 1, F. Borgnolutti 1, B. Jenninger 1, P. Ryan 2 Abstract The next generation of LHC superconducting magnets is very challenging and must operate in harsh conditions: high radiation doses in a range between 10 and 50 MGy, high voltage environment of 1 to 5 kv during the quench, dynamic high magnetic field up to 12 T, dynamic temperature range 1.8 K to 300 K in 0.6 sec. For magnet performance and long term reliability it is important to study dynamic thermal effects, such as the heat flux through the magnet structure, or measuring hot spot in conductors during a magnet quench with high sampling rates above 200 Hz. Available on the market cryogenic temperature sensors comparison is given. An analytical model for special electrically insulating thermal anchor (Kapton pad) with high voltage insulation is described. A set of instrumentation is proposed for fast monitoring of thermal processes during normal operation, quenches and failure situations. This paper presents the technology applicable for mounting temperature sensors on high voltage superconducting (SC) cables. The temperature measurements of fast heat crosspropagation in MQXC SC cable and FCM dynamic tests are also presented. Novel thermometry has been successfully applied to several CERN magnet systems (MQXC, FCM and FRESCA2). The variety of high-voltage thin film thermal anchors and fast temperature sensor are the basis of the LHC novel cryogenic thermometry. The MQXC model Quadruple of 1.8 m long has been developed at CERN for LHC accelerator insertion upgrade -Phase 1 [2-3]. The magnet incorporates several novel concepts to extract high levels of heat flux into liquid helium at 1.8 K. Internal thermometry (Fig. 1) has to survey at high mechanical stresses, 0-12 T fast changing magnetic field and to measure magnet hot spots temperature. Index Terms Electric resistance, Quench heaters, Temperature measurement, Superconducting coils. T I. INTRODUCTION he conception of new superconducting magnets with record parameters requires the use of composite materials, metal alloys and superconductors with extreme mechanical and radiation characteristics. Studying the behavior of such systems at cryogenic temperature require a qualitatively new approach in the development and use of diagnostic systems, including cryogenic thermometry. During magnet quench the coils are at high voltage and experiencing rapid temperature change. Our accurate and fast thermometry can be realized by mounting the thermometer directly on zone to be measured in our case on the SC cable. New fixation of fast cryogenic thermometer was realized by use of thin-film thermal anchor that may be glued or soldered at the desired position. To optimize thermal performance and electrical insulation of this anchor an analytical model was developed. Polyimide film meets the 50 MGy radiation requirements. Twisted manganin wires and DC measuring current of 10-30 µa were chosen to reduce the parasitic heat load via wires and temperature sensor self-heating. Wires insulated with polyimide were tested at 4.5 K 1.8 K and 1.5 kv. High speed recording (>200 Hz) was provided with data acquisition system MX840A [1]. Manuscript received 14 th July, 2013. 1 V. Datskov 1, G. Kirby 1, L. Bottura 1, J.C. Perez 1, F. Borgnolutti 1, B. Jenninger 1, are with CERN, 1211, Geneva 23, Switzerland, (e-mail: vladimir.ivanovich.datskov@cern.ch), phone +41 22 767 1980, fax +41 22 767 6300, P. Ryan 2 is with Temati, Tackley, Oxford, OX5 3BL, UK. Fig. 1: MQXC magnet cross section. Fast Cycled superconducting Magnets (FCM) is a dipole for CERN accelerator booster PS2 upgrade [4-5]. FCM dipole produces the rapid field required by the PS2 (1.8 T, 1.5 T/s). Magnet coils operate in vacuum and are made from tubular Nb-Ti cable with circulating supercritical helium flow. The internal thermometry in vacuum conditions has to measure the temperature of SC cables at voltage of 1 kv, joints and other points in the magnet structure. FRESCA2 is a 100 mm aperture Nb 3 Sn dipole magnet, generating a bore field of 13 T [6-7]. It has a massive 10 tons support structure to withstand forces between coils. Thermometry was designed to control magnet cooling and to keep allowable temperature gradients. II. CRYOGENIC TEMPERATURE SENSORS The main objective for accelerator cryogenic thermometry is to have a precise and fast temperature measurement over a large temperature interval, for periods lasting 10 years or longer and at reasonable cost. Cryogenic sensor suppliers do not offer a warranty on qualitative thermometry for 10-15 years. Therefore in-house development of thermometry application for magnets are required to make it cheaper, reliable and satisfying the challenging specifications. The LHC accelerator calibration group at CERN in 1998 has conducted the irradiation tests of seven selected resistive-type

1PoAP-01 2 temperature sensors at cryogenic conditions [8]. Three types of cryogenic sensors have been selected for applications able to withstand the radiation conditions of LHC accelerator. After being irradiated with a neutrons dose of 4x10 14 n/cm 2 at 1.8 K, a temperature shift of +2 mk was observed for the AB (Allan Bradley) carbon sensors, shift of +0.3 mk for Carbon Ceramic Sensor (CCS-Russian name is TVO) [9] and shift of +1 mk for CX (Cernox) [10] sensor. After neutron dose of 1.1x10 17 n/cm 2 TVO sensor had a shift of 0.04 K at 4.2K [11]. AB and CCS sensors response time is 8 ms and 1 ms at 4.2 K accordingly [12]. Comparison [13] showed that on the market there are two cryogenic temperature sensors CX [10] and CCS [14] which have similar electrical characteristics. The major parameters of these sensors are presented in the Table I. CCS sensors offer a good long-term stability and fast response due to silver-leads difuse electrical contacts and ceramic body. Table I. COMPARISON OF TEMPERATURE SENSORS Sensor Price/each Resistance at: Long-term Time type from 300 K/4.2 K stability response company Ω at 4.2 K at 4.2 K CX-1050 665 USD 60/3500 25 mk/year 15 ms CCS/A 380 USD 920/3500 1 mk/year 1 ms III. THERMAL ANCHOR DESIGN The thermal anchors that are used in our setup are based on the commercially available polyimide (Kapton) film with thin metallic layers (generally gold plated copper) on either side. On one side metallic strips are prepared by lithography or chemical edging. The electrical wire is soldered on one side of the strip whereas the lead of the temperature sensor is soldered at the opposite end. The substrate (0 in Fig. 2) is at the temperature T 0, which is the quantity we want to measure. The heat Q b from the wire as a result of thermal conductance is evacuated along the strip, resulting in a remaining temperature T c where the temperature lead is connected. Depending on the material choice and dimensions, the thermal anchor can be optimized such that the difference between T c and the temperature T 0 to be measured is minimized. below are as the following: k-thermal conductivity, L-length, s-thickness, A-cross-section, w-width of wire and layers, T a and T b -wire temperature, T c -conductive layer temperature, Q a - heat flux along thermal anchor (function of x), Q b - heat flux from connecting wire. The conductive heat load along the wire is: (1) The heat flux across the thermal anchor causes the variation of the heat flux along the thermal anchor. with (2) The heat flux along the thermal anchor is: Differentiation gives and applying the definition : (4) Equation 2 with equation 4 gives: (5) By defining and, as well as considering the thermal conductance being constant in the temperature range (hence using their mean values), the corresponding differential equation is: (6) With the boundary conditions: and (7, 8) And the following definitions: and (3) (9,10) The following solution to the upper differential equation can be found as the following: ( ( )) (11) Figure 3 shows the calculated temperature gradient along a thermal anchor based on equation (11). Fig. 3: Calculated temperature gradient along the strip. Fig. 2: Schematic of a thermal anchor based on metal strips on a polyimide film: 0 - substrate, 1 - wire, 2 - conductive layer, 3 - polyimide insulator layer. The following equations are an analytical approach to estimate this difference. Symbols description for equations In this calculation the copper strip size was 1.6x30x0.018 mm, and we had a 0.05 mm thick polyimide foil. For copper we used the mean thermal conductance 500 W/m/K, and for polyimide 0.3 W/m/K. In vacuum the heat load from 300 K to 4.2 K via copper electrical wire with diameter of 0.1 mm and length of 0.5 m is about 2.3 mw. As shown on the graph, the error in the measurement even in this unfavorable situation with copper wires would still be below 1mK. Thermal anchors are available on the market from Temati company with the

1PoAP-01 3 product name thermal pad [14]. Some later research has demonstrated that such thermal anchor provides accurate temperature measurements and has electrical insulation of 100 GΩ at the voltage of 1.5 kv. It was no change of electrical insulation and thermal conductivity after its soldering on desired metal surface. It is possible to increase insulation voltage above 1.5 kv by copper strips geometry optimization. T2 showed temperature dropping during 10-20 ms. Using modified thermal pads geometry it was possible to mount CCS sensors on several locations of MQXC magnet coils (Fig. 6-7). A. MQXC thermometry IV. THERMOMETRY APPLICATION For the MQXC model we developed a test rig to characterize fast performance of CCS sensors. Two CCS sensors were mounted with thermal pads, which were glued on two sides of MQXC flat SC cable using VGE-7031varnish [10]. The goal of the test was checking of the heat transfer and the time response of sensors during the fast pulse heating of MQXC SC cable, immersed in liquid helium. The fast heat pulse was done by discharging of 10 mf capacitor (0-80V) into a spot heater, glued on one side of SC cable. Sensor T1 was mounted on the surface of spot heater and another T2 was mounted on the opposite side of SC cable (Fig. 4). Fig. 6: CCS sensor and thermal pad, mounted on MQXC coil conductor near voltage taps. Fig. 4: CCS sensor T2, mounted on MQXC superconducting cable with use of thermal pad. Fig. 7: CCS sensors and thermal pads, mounted on MQXC lamination. B. FCM thermometry FCM magnet with tubular SC cable in vacuum had a strict requirement for cryogenic temperature sensors, which include the following: mounting of sensors on a round surface of SC cable with electrical insulation of 1 kv to the cable, accuracy of measurements better than 0.01 K in the temperature range of 4-20 K during the fast current ramping in the magnet. Fig. 5: MQXC spot heater cryogenic testing. From recorded data at rate of 1200 Hz one can deduce (Fig. 5) a fast time response of T1 sensor on the spot heater in the range of 3-5 ms in helium gas at 4.5 K. The presence of liquid helium delays the response time up to 8-10 ms. Other sensor Fig. 8: CCS sensors allocation in FCM magnet. Twelve CCS sensors were mounted in different locations of FCM magnet (Fig. 8) using glued straight and soldered curved thermal pads (Fig. 9). During calorimetric measurement we increased the heating in steps of 5-10-15-20 W of helium flow

1PoAP-01 4 with the heater mounted on the helium supply pipe >1 m before the inlet of FCM coils. examine the performance of FRESCA2 thermometry a special test rig was created. In the top and bottom of aluminum alloy cylinder two CCS sensors were mounted with screws size M10. The edge of the screw with mounted sensor had a good thermal contact inside of aluminum body using Apiezon-N grease [10]. The cool-down in liquid nitrogen showed smooth temperature T1 decreasing at the bottom (Fig. 12). This confirms no liquid nitrogen has penetrated to the sensor. A batch of 10 CCS sensors, mounted as Fig. 11 in the dummy magnet system. Cool-down of this 10 tons system till 77.4 K over 1 week demonstrated that temperature gradients were within the allowed range. Fig. 9: Curved thermal pad with CCS sensor on FCM cable. Recorded data has shown a 2 s time response of T3 sensor on the second coil inlet (Fig. 10). Fig. 12: FRESCA2 model cylinder cooling in liquid nitrogen. Fig. 10: FCM coil 2 heating during calorimetric test. C. FRESCA2 thermometry FRESCA2 magnet requires a special technology of sensors mounting in holes of massive magnet support components using screws of different size and deep. All components of this magnet are immersed in cryogenic liquid: during cool-down in liquid nitrogen and in liquid helium at working conditions. Accurate cryogenic thermometry in massive metal structure immersed in cryogenic liquid is not trivial. One has to ensure a V. CONCLUSION Precise thermometry, based on thin-film thermal pads and fast, low cost CCS carbon-ceramic sensor, performed well during the cryogenic tests of three CERN projects: MQXC, FCM and FRESCA2. Different mounting techniques of CCS sensors were applied in each system. With this thermometry we could record the pulsed heat propagation from the MQXC spot heater through SC cable. The time response of CCS sensor mounting fixture was in the range 3-5 ms at 4.5 K in helium gas. This system permits the future studies of high heat fluxes with high voltages through the equipment needed for the Hi-Luminosity LHC upgrade foreseen in 2022. ACKNOWLEDGMENT The authors thank the teams in CERN MSC group, Cryo-Lab, and SM18 for their help with assembling and testing of the selection of sensor set-up s. In particular: Laetitia Dufay- Chanat for help with cryogenic insert, Michael Guinchard for guidance and the implementation of the fast data acquisition system, Vincent Roger for analysis of FCM data. Fig. 11: FRESCA2 temperature sensor in the screw. a good thermal contact of thermometer to the metal body and fixture seal from cryogenic liquid. Magnet support is made of Al-alloy and sensor mounting technique was chosen with the use of aluminum screws and Teflon screw-cups (Fig. 11).To REFERENCES [1] http://www.hbm.com/en/menu/products/measurement-electronicssoftware/compact-universal-data-acquisition-system/quantumx-mx840a/ [2] G.A. Kirby et al. Engineering Design and Manufacturing Challenges for a Wide-Aperture, Superconducting Quadrupole Magnet, IEEE Trans. Magn., 22 (2012). [3] G. Kirby et al. LHC IR Upgrade Nb-Ti, 120mm Aperture Model

1PoAP-01 5 Quadrupole Test Results at 1.8 K, Presentation 3OrCC-04, MT23. [4] L. Bottura et al. The Fast Cycled superconducting Magnets (FCM) R&D program at CERN, HHH-2008 proceedings, pp. 71-75. [5] G. Willering et al. Fast Cycled Magnet (FCM) demonstrator program at CERN: Test station, instrumentation and measurement campaign, Presentation 4OrCB-05, MT23. [6] P. Ferracin et al., Development of the EuCARD Nb3Sn Dipole Magnet FRESCA2, IEEE Trans. Magn., 23 (2013). [7] J.E. Muñoz Garcia et al. "Assembly, loading, and cool-down of the FRESCA2 support structure", Presentation 3PoAF, MT23. [8] J-F. Amand et al., Neutron Irradiation Tests in Superfluid Helium of LHC Cryogenic Thermometers, CERN-LHC Project report #209, July 1998. [9] V.I. Datskov and J.G. Weisend II, "Characteristics of Russian Carbon Resistance (TVO) Cryogenic Thermometers", ICEC-15 Proceedings, Cryogenics. 1994, Vol.34, pp. 425-428. [10] http://www.lakeshore.com/products/cryogenic-temperature- Sensors/Cernox/ [11] V. Datskov et al.,"long-life cryogenic thermometry in particle accelerators and other demanding applications", IEEE Trans. Magn.,10 (2000), pp.1403-1406. [12] V.I. Datskov et al., "Inertial characteristics of cryogenic temperature sensors", Preprint of JINR, 8-83-45, Dubna, 1983, (in russian). [13] Süßer M., Comparison of TVO and Cernox temperature sensors, Proceedings of ICEC 22-ICMC 2008, pp. 479-482 [14] http://www.temati-uk.com/