University of Missouri St. Louis UMSL Project No. S Thomas Jefferson Library Elevator R&B Project No: Renovation & Repairs

Similar documents
A. Section includes surface preparation and the application of paint systems on interior substrates.

SECTION GYPSUM BOARD

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

GYPSUM BOARD

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

A. Section includes surface preparation and application of wood finishes[.]

Student Services & Classroom Addition

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats.

SECTION GYPSUM BOARD

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Ash Brook Golf Course Scotch Plains, New Jersey

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

Ice Rink Renovation & New Clubhouse

1. Interior gypsum board. 2. Glass-mat gypsum sheathing board for ceilings and soffits. 3. Cement board. 4. Sound attenuation blankets

SECTION (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES

EDGEWATER, FLORIDA JUNE 14, 2010

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

A. Product Data: For each type of product specified.

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD

DAYTONA BEACH PIER BUILDING RESTORATION 06/10

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 09 - FINISHES

B. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors and finishes available for wood flooring.

Section GYPSUM DRYWALL

SAN DIEGO STATE UNIVERSITY PACIFIC CORNERSTONE ARCHITECTS TENOCHCA HALL PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

SECTION GYPSUM BOARD SYSTEM

SECTION GYPSUM BOARD SYSTEM

SECTION COMMON WORK RESULTS FOR ELECTRICAL

SECTION EXTERIOR PAINTING PART 1 - GENERAL 1.1 SUMMARY

SECTION ACOUSTICAL PANEL CEILINGS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:

Construction Standards PAGE

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

SECTION (09941) - TEXTURED FINISHING

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

SECTION GYPSUM BOARD PART 1 - GENERAL

SECTION GYPSUM BOARD

B. Related Sections: The following Sections contain requirements that relate to this Section:

SECTION HIGH-PERFORMANCE COATINGS

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

SECTION GYPSUM BOARD ASSEMBLIES

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Construction Standards PAGE

SECTION GYPSUM BOARD ASSEMBLIES

Union County Vocational - Technical Schools Scotch Plains, New Jersey

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

1. Seismic Loads: Reference structural drawings.

A. Extent of each type of gypsum drywall construction required is indicated on the Drawings.

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

RENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION PENETRATION FIRESTOPPING PART 1- GENERAL PART 2- PRODUCTS 1.1 RELATED DOCUMENTS

Fishers, Indiana Axis Architecture + Interiors SECTION SECTION THERMAL INSULATION PART 1 - GENERAL

SECTION GYPSUM BOARD ASSEMBLIES

Rhode Island College - Recreation Center, Providence, RI June 7, 2010 Designpartnerhip of Cambridge Inc., 2909 SECTION

1. Nonload-bearing steel framing members for gypsum board assemblies. 2. Gypsum board assemblies attached to steel framing.

Copyright 2010 AIA MasterSpec Short Form 02/10 PRODUCT MASTERSPEC LICENSED BY ARCOM TO GEORGIA-PACIFIC GYPSUM LLC

SECTION RESILIENT SHEET FLOORING

SECTION GYPSUM BOARD

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

SECTION GYPSUM BOARD

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

SECTION NON--STRUCTURAL METAL FRAMING

SECTION RESILIENT SHEET FLOORING

A. Product Data: For each joint-sealant product indicated. D. Joint-Sealant Schedule: Include the following information:

SECTION GYPSUM BOARD

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

Life Hall Renovation Issued: July 9, 2014 Montclair State University Addendum No. 1 Owner's Project No Cannon Design Project No

SECTION JOINT SEALERS 1.03 THIS SECTION INCLUDES JOINT SEALERS FOR THE FOLLOWING LOCATIONS:

Student Services & Classroom Addition

Venger Electrostatic Coatings Master Specification Page 1

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

1. Include construction details, materials, individual components and profiles, and finishes.

SUNY GENESEO RED JACKET DINING HALL RENOVATION SECTION JOINT SEALANTS

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

SECTION PORTLAND CEMENT PLASTER (STUCCO) WITH ACRYLIC FINISH

MDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

The City of Winnipeg NEWPCC Lab Renovation

SECTION PAINTING

SECTION PAINTING. A. Surface preparation and field application of paints and coatings at interior and exterior surfaces.

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

SECTION NON-STRUCTURAL METAL FRAMING

SPECIFIER SHALL REMOVE COMMENTS IN BOLD TEXT PRIOR TO SUBMITTING.

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

Transcription:

SECTION 092116.23 - GYPSUM BOARD SHAFT WALL ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: Gypsum board shaft wall assemblies. 1.3 ACTION SUBMITTALS A. Product Data: For each component of gypsum board shaft wall assembly. 1.4 DELIVERY, STORAGE, AND HANDLING A. Store materials inside under cover and keep them dry and protected against weather, condensation, direct sunlight, construction traffic, and other potential causes of damage. Stack panels flat and supported on risers on a flat platform to prevent sagging. 1.5 FIELD CONDITIONS A. Environmental Limitations: Comply with ASTM C 840 requirements or with gypsum board manufacturer's written recommendations, whichever are more stringent. B. Do not install interior products until installation areas are enclosed and conditioned. C. Do not install panels that are wet, moisture damaged, or mold damaged. 1. Indications that panels are wet or moisture damaged include, but are not limited to, discoloration, sagging, and irregular shape. 2. Indications that panels are mold damaged include, but are not limited to, fuzzy or splotchy surface contamination and discoloration. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Fire-Resistance-Rated Assemblies: For fire-resistance-rated assemblies, provide materials and construction identical to those tested in assembly indicated according to ASTM E 119 by an independent testing agency. 2.2 GYPSUM BOARD SHAFT WALL ASSEMBLIES A. Fire-Resistance Rating: 2 hours GYPSUM BOARD SHAFT WALL ASSEMBLIES 092116.23-1

B. Studs: Manufacturer's standard profile for repetitive members, corner and end members, and fire-resistance-rated assembly indicated. 1. Depth: 2-1/2 inches (64 mm) 2. Minimum Base-Metal Thickness: 0.0219 inch (0.56 mm) C. Runner Tracks: Manufacturer's standard J-profile track with manufacturer's standard long-leg length, but at least 3 inches (76.2 mm) long and matching studs in depth. 1. Minimum Base-Metal Thickness: Matching steel studs. D. Firestop Tracks: Provide firestop track at head of shaft wall on each floor level. E. Room-Side Finish: As indicated. F. Shaft-Side Finish: As indicated. 2.3 PANEL PRODUCTS A. Panel Size: Provide in maximum lengths and widths available that will minimize joints in each area and that correspond with support system indicated. B. Gypsum Shaftliner Board, Moisture- and Mold-Resistant Type X: ASTM C 1396/C 1396M; manufacturer's proprietary fire-resistive liner panels with moisture- and mold-resistant core and surfaces. 1. Thickness: 1 inch (25.4 mm). 2. Long Edges: Double bevel. 3. Mold Resistance: ASTM D 3273, score of 10 as rated according to ASTM D 3274. C. Gypsum Board: As specified in Section 092900 "Gypsum Board." 2.4 NON-LOAD-BEARING STEEL FRAMING A. Steel Framing Members: Comply with ASTM C 645 requirements for metal unless otherwise indicated. 1. Protective Coating: ASTM A 653/A 653M, G40 (Z120), hot-dip galvanized unless otherwise indicated. B. Firestop Tracks: Top runner manufactured to allow partition heads to expand and contract with movement of the structure while maintaining continuity of fire-resistance-rated assembly indicated; in thickness not less than indicated for studs and in width to accommodate depth of studs. 2.5 AUXILIARY MATERIALS A. General: Provide auxiliary materials that comply with manufacturer's written recommendations. GYPSUM BOARD SHAFT WALL ASSEMBLIES 092116.23-2

B. Trim Accessories: Cornerbead, edge trim, and control joints of material and shapes as specified in Section 092900 "Gypsum Board" that comply with gypsum board shaft wall assembly manufacturer's written recommendations for application indicated. C. Steel Drill Screws: ASTM C 1002 unless otherwise indicated. Track Fasteners: Power-driven fasteners of size and material required to withstand loading conditions imposed on shaft wall assemblies without exceeding allowable design stress of track, fasteners, or structural substrates in which anchors are embedded. 1. Expansion Anchors: Fabricated from corrosion-resistant materials, with capability to sustain, without failure, a load equal to 5 times design load, as determined by testing according to ASTM E 488 conducted by a qualified testing agency. 2. Power-Actuated Anchors: Fastener system of type suitable for application indicated, fabricated from corrosion-resistant materials, with capability to sustain, without failure, a load equal to 10 times design load, as determined by testing according to ASTM E 1190 conducted by a qualified testing agency. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates to which gypsum board shaft wall assemblies attach or abut, with Installer present. Examine for compliance with requirements for installation tolerances and other conditions affecting performance. B. Examine panels before installation. Reject panels that are wet, moisture damaged, or mold damaged. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. General: Install gypsum board shaft wall assemblies to comply with requirements of fireresistance-rated assemblies indicated, manufacturer's written installation instructions, and ASTM C 754 other than stud-spacing requirements. B. Do not bridge building expansion joints with shaft wall assemblies; frame both sides of expansion joints with furring and other support. C. Install supplementary framing in gypsum board shaft wall assemblies around openings and as required for blocking, bracing, and support of gravity and pullout loads of fixtures, equipment, services, heavy trim, and similar items that cannot be supported directly by shaft wall assembly framing. D. Isolate perimeter of gypsum panels from building structure to prevent cracking of panels, while maintaining continuity of fire-rated construction. E. Firestop Tracks: Where indicated, install to maintain continuity of fire-resistance-rated assembly indicated. GYPSUM BOARD SHAFT WALL ASSEMBLIES 092116.23-3

F. Installation Tolerance: Install each framing member so fastening surfaces vary not more than 1/8 inch (3 mm) from the plane formed by faces of adjacent framing. 3.3 PROTECTION A. Protect installed products from damage from weather, condensation, direct sunlight, construction, and other causes during remainder of the construction period. B. Remove and replace panels that are wet, moisture damaged, or mold damaged. 1. Indications that panels are wet or moisture damaged include, but are not limited to, discoloration, sagging, and irregular shape. 2. Indications that panels are mold damaged include, but are not limited to, fuzzy or splotchy surface contamination and discoloration. END OF SECTION 092116.23 GYPSUM BOARD SHAFT WALL ASSEMBLIES 092116.23-4

SECTION 092900 - GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Special Conditions of Division 01 Specification, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Interior gypsum board. B. Related Requirements: 1. Section 092116.23 "Gypsum Board Shaft Wall Assemblies" for metal shaft-wall framing, gypsum shaft liners, and other components of shaft-wall assemblies. 1.3 SUBMITTALS A. Product Data: For each type of product. 1.4 DELIVERY, STORAGE AND HANDLING A. Store materials inside under cover and keep them dry and protected against weather, condensation, direct sunlight, construction traffic, and other potential causes of damage. Stack panels flat and supported on risers on a flat platform to prevent sagging. 1.5 FIELD CONDITIONS A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written recommendations, whichever are more stringent. B. Do not install paper-faced gypsum panels until installation areas are enclosed and conditioned. C. Do not install panels that are wet, those that are moisture damaged, and those that are mold damaged. 1. Indications that panels are wet or moisture damaged include, but are not limited to, discoloration, sagging, or irregular shape. 2. Indications that panels are mold damaged include, but are not limited to, fuzzy or splotchy surface contamination and discoloration. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS GYPSUM BOARD 092900-1

A. Fire-Resistance-Rated Assemblies: For fire-resistance-rated assemblies, provide materials and construction identical to those tested in assembly indicated according to ASTM E 119 by an independent testing agency. 2.2 GYPSUM BOARD, GENERAL A. Size: Provide maximum lengths and widths available that will minimize joints in each area and that correspond with support system indicated. 2.3 INTERIOR GYPSUM BOARD A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: 1. Georgia-Pacific Gypsum LLC. 2. National Gypsum Company. 3. USG Corporation. B. Gypsum Board, Type X: ASTM C 1396/C 1396M. 1. Thickness: 5/8 inch. 2. Long Edges: Tapered. 2.4 TRIM ACCESSORIES A. Interior Trim: ASTM C 1047. 1. Material: Galvanized or aluminum-coated steel sheet or rolled zinc. 2. Shapes: a. Cornerbead. b. LC-Bead: J-shaped; exposed long flange receives joint compound. 2.5 JOINT TREATMENT MATERIALS A. General: Comply with ASTM C 475/C 475M. B. Joint Tape: 1. Interior Gypsum Board: Paper. C. Joint Compound for Interior Gypsum Board: For each coat use formulation that is compatible with other compounds applied on previous or for successive coats. 1. Prefilling: At open joints and damaged surface areas, use setting-type taping compound. 2. Embedding and First Coat: For embedding tape and first coat on joints, fasteners, and trim flanges, use drying-type, all-purpose compound. 3. Fill Coat: For second coat, use drying type, all purpose sandable topping compound. 4. Finish Coat: For third coat, use drying type, all purpose sandable topping compound. GYPSUM BOARD 092900-2

2.6 AUXILIARY MATERIALS A. General: Provide auxiliary materials that comply with referenced installation standards and manufacturer's written recommendations. B. Steel Drill Screws: ASTM C 1002, unless otherwise indicated. 1. Use screws complying with ASTM C 954 for fastening panels to steel members from 0.033 to 0.112 inch (0.84 to 2.84 mm) thick. C. Fire-Resistance-Rated Assemblies: Comply with mineral-fiber requirements of assembly. D. Acoustical Joint Sealant: Manufacturer s standard non-sag, paintable, non-staining latex sealant complying with ASTM C 834. Product effectively reduces airborne sound transmission through perimeter joints and openings in building construction as demonstrated by testing representative assemblies according to ASTM E 90. 1. Products: Subject to compliance with requirements, available products that may be incorporated into the Work include, but are not limited to, the following: PART 3 - EXECUTION 3.1 EXAMINATION a. Pecora Corporation; AC-20 FTR. b. USG Corporation; SHEETROCK Acoustical Sealant. A. Examine areas and substrates including welded hollow-metal frames and framing, with Installer present, for compliance with requirements and other conditions affecting performance. B. Examine panels before installation. Reject panels that are wet, moisture damaged, and mold damaged. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 APPLYING AND FINISHING PANELS, GENERAL A. Comply with ASTM C 840. B. Install ceiling panels across framing to minimize the number of abutting end joints and to avoid abutting end joints in central area of each ceiling. Stagger abutting end joints of adjacent panels not less than one framing member. C. Install panels with face side out. Butt panels together for a light contact at edges and ends with not more than 1/16 inch (1.5 mm) of open space between panels. Do not force into place. D. Locate edge and end joints over supports, except in ceiling applications where intermediate supports or gypsum board back-blocking is provided behind end joints. Do not place tapered edges against cut edges or ends. Stagger vertical joints on opposite sides of partitions. Do not make joints other than control joints at corners of framed openings. GYPSUM BOARD 092900-3

E. Cover both faces of support framing with gypsum panels in concealed spaces (above ceilings, etc.), except in chases braced internally. 1. Fit gypsum panels around ducts, pipes, and conduits. 2. Where partitions intersect structural members projecting below underside of floor/roof slabs and decks, cut gypsum panels to fit profile formed by structural members; allow 1/4- to 3/8-inch- (6.4- to 9.5-mm-) wide joints to install sealant. F. Isolate perimeter of gypsum board applied to non-load-bearing partitions at structural abutments, except floors. Provide 1/4- to 1/2-inch- (6.4- to 12.7-mm-) wide spaces at these locations and trim edges with edge trim where edges of panels are exposed. Seal joints between edges and abutting structural surfaces with sealant. G. Attachment to Steel Framing: Attach panels so leading edge or end of each panel is attached to open (unsupported) edges of stud flanges first. 3.3 APPLYING INTERIOR GYPSUM BOARD A. Install interior gypsum board in the following locations: 1. Type X: As indicated on Drawings. B. Multilayer Application: 1. Retain first subparagraph below for multilayer gypsum board ceilings. 2. Apply base layers at right angles to framing members and offset face-layer joints one framing member, 16 inches (400 mm) minimum, from parallel base-layer joints, unless otherwise indicated or required by fire-resistance-rated assembly. 3. On partitions/walls, apply gypsum board indicated for base layers and face layers vertically (parallel to framing) with joints of base layers located over stud or furring member and face-layer joints offset at least one stud or furring member with base-layer joints, unless otherwise indicated or required by fire-resistance-rated assembly. Stagger joints on opposite sides of partitions. 4. Fastening Methods: Fasten base layers and face layers separately to supports with screws. 3.4 INSTALLING TRIM ACCESSORIES A. General: For trim with back flanges intended for fasteners, attach to framing with same fasteners used for panels. Otherwise, attach trim according to manufacturer's written instructions. B. Interior Trim: Install in the following locations: 1. Cornerbead: Use at outside corners. 2. LC-Bead: Use at exposed panel edges. GYPSUM BOARD 092900-4

3.5 FINISHING GYPSUM BOARD A. General: Treat gypsum board joints, interior angles, edge trim, control joints, penetrations, fastener heads, surface defects, and elsewhere as required to prepare gypsum board surfaces for decoration. Promptly remove residual joint compound from adjacent surfaces. B. Prefill open joints and damaged surface areas. C. Apply joint tape over gypsum board joints, except for trim products specifically indicated as not intended to receive tape. D. Gypsum Board Finish Levels: Finish panels to levels indicated below and according to ASTM C 840: 1. Level 1: Hoistway elevator areas, concealed areas and where indicated. 3.6 PROTECTION A. Protect adjacent surfaces from drywall compound and promptly remove from floors and other non-drywall surfaces. Repair surfaces stained, marred, or otherwise damaged during drywall application. B. Protect installed products from damage from weather, condensation, direct sunlight, construction, and other causes during remainder of the construction period. C. Remove and replace panels that are wet, moisture damaged, and mold damaged. END OF SECTION 092900 GYPSUM BOARD 092900-5

This Page Left Intentionally Blank

SECTION 099123 - INTERIOR PAINTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section includes surface preparation and the application of paint systems on the following interior substrates: 1. Concrete. 2. Concrete masonry units (CMU). 3. Steel. 4. Galvanized metal. 5. Gypsum board. B. Related Requirements: 1. Section 051200 "Structural Steel Framing" for shop priming of metal substrates with primers specified in this Section. 1.3 DEFINITIONS A. Gloss Level 1: Not more than 5 units at 60 degrees and 10 units at 85 degrees, according to ASTM D 523. B. Gloss Level 2: Not more than 10 units at 60 degrees and 10 to 35 units at 85 degrees, according to ASTM D 523. C. Gloss Level 3: 10 to 25 units at 60 degrees and 10 to 35 units at 85 degrees, according to ASTM D 523. D. Gloss Level 4: 20 to 35 units at 60 degrees and not less than 35 units at 85 degrees, according to ASTM D 523. E. Gloss Level 5: 35 to 70 units at 60 degrees, according to ASTM D 523. F. Gloss Level 6: 70 to 85 units at 60 degrees, according to ASTM D 523. G. Gloss Level 7: More than 85 units at 60 degrees, according to ASTM D 523. 1.4 SUBMITTALS A. Product Data: For each type of product. Include preparation requirements and application instructions. B. Samples for Verification: For each type of paint system and in each color and gloss of topcoat. INTERIOR PAINTING 099123-1

1. Submit Samples on rigid backing, 8 inches (200 mm) square. 2. Step coats on Samples to show each coat required for system. 3. Label each coat of each Sample. 4. Label each Sample for location and application area. C. Product List: For each product indicated, include the following: 1. Cross-reference to paint system and locations of application areas. Use same designations indicated on Drawings and in schedules. 2. Printout of current "MPI Approved Products List" for each product category specified in Part 2, with the proposed product highlighted. 3. VOC content. 1.5 DELIVERY, STORAGE, AND HANDLING A. Store materials not in use in tightly covered containers in well-ventilated areas with ambient temperatures continuously maintained at not less than 45 deg F (7 deg C). 1. Maintain containers in clean condition, free of foreign materials and residue. 2. Remove rags and waste from storage areas daily. 1.6 FIELD CONDITIONS A. Apply paints only when temperature of surfaces to be painted and ambient air temperatures are between 50 and 95 deg F (10 and 35 deg C). B. Do not apply paints when relative humidity exceeds 85 percent; at temperatures less than 5 deg F (3 deg C) above the dew point; or to damp or wet surfaces. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: 1. Glidden Professional. 2. Sherwin-Williams Company (The). 3. Scuffmaster 2.2 PAINT, GENERAL A. Master Painters Institute (MPI) Standards: Provide products that comply with MPI standards indicated and that are listed in its "MPI Approved Products List." B. Material Compatibility: 1. Provide materials for use within each paint system that are compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience. INTERIOR PAINTING 099123-2

2. For each coat in a paint system, provide products recommended in writing by manufacturers of topcoat for use in paint system and on substrate indicated. C. VOC Content: Products shall comply with VOC limits of authorities having jurisdiction. 1. Flat Paints and Coatings: 50 g/l. 2. Nonflat Paints and Coatings: 150 g/l. 3. Dry-Fog Coatings: 400 g/l. 4. Primers, Sealers, and Undercoaters: 200 g/l. 5. Anticorrosive and Antirust Paints Applied to Ferrous Metals: 250 g/l. 6. Zinc-Rich Industrial Maintenance Primers: 340 g/l. 7. Pretreatment Wash Primers: 420 g/l. 8. Floor Coatings: 100 g/l. 9. Shellacs, Clear: 730 g/l. 10. Shellacs, Pigmented: 550 g/l. D. Low-Emitting Materials: Interior paints and coatings shall comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." E. Colors: As selected by Owner s Representative and Elevator Specification. 2.3 BLOCK FILLERS A. Block Filler, Latex, Interior/Exterior: MPI #4. 2.4 PRIMERS/SEALERS A. Primer Sealer, Interior, Institutional Low Odor/VOC: MPI #149. 2.5 METAL PRIMERS A. Primer, Rust-Inhibitive, Water Based: MPI #107. B. Primer, Galvanized, Water Based: MPI #134. 2.6 WATER-BASED PRIMERS A. Primer, Stain Blocking, Water Based: MPI #137. 2.7 WATER-BASED PAINTS A. Latex, Interior, Institutional Low Odor/VOC, Semi-Gloss (Gloss Level 5): MPI #147. 2.8 FLOOR COATINGS A. Floor Paint, Latex, Low Gloss (Maximum Gloss Level 3): MPI #60. INTERIOR PAINTING 099123-3

2.9 ELEVATOR DOOR FRAMES A. Scuffmaster Premium eggshell finish PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with Applicator present, for compliance with requirements for maximum moisture content and other conditions affecting performance of the Work. B. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter as follows: 1. Concrete: 12 percent. 2. Masonry (Clay and CMU): 12 percent. 3. Gypsum Board: 12 percent. C. Gypsum Board Substrates: Verify that finishing compound is sanded smooth. D. Verify suitability of substrates, including surface conditions and compatibility with existing finishes and primers. E. Proceed with coating application only after unsatisfactory conditions have been corrected. 1. Application of coating indicates acceptance of surfaces and conditions. 3.2 PREPARATION A. Comply with manufacturer's written instructions and recommendations in "MPI Manual" applicable to substrates indicated. B. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting. 1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection if any. C. Clean substrates of substances that could impair bond of paints, including dust, dirt, oil, grease, and incompatible paints and encapsulants. 1. Remove incompatible primers and reprime substrate with compatible primers or apply tie coat as required to produce paint systems indicated. D. Concrete Substrates: Remove release agents, curing compounds, efflorescence, and chalk. Do not paint surfaces if moisture content or alkalinity of surfaces to be painted exceeds that permitted in manufacturer's written instructions. INTERIOR PAINTING 099123-4

E. Masonry Substrates: Remove efflorescence and chalk. Do not paint surfaces if moisture content or alkalinity of surfaces or mortar joints exceed that permitted in manufacturer's written instructions. F. Steel Substrates: Remove rust, loose mill scale, and shop primer, if any. Clean using methods recommended in writing by paint manufacturer. G. Shop-Primed Steel Substrates: Clean field welds, bolted connections, and abraded areas of shop paint, and paint exposed areas with the same material as used for shop priming to comply with SSPC-PA 1 for touching up shop-primed surfaces. H. Galvanized-Metal Substrates: Remove grease and oil residue from galvanized sheet metal fabricated from coil stock by mechanical methods to produce clean, lightly etched surfaces that promote adhesion of subsequently applied paints. 3.3 APPLICATION A. Apply paints according to manufacturer's written instructions and to recommendations in "MPI Manual." 1. Use applicators and techniques suited for paint and substrate indicated. 2. Paint surfaces behind movable equipment and furniture same as similar exposed surfaces. Before final installation, paint surfaces behind permanently fixed equipment or furniture with prime coat only. 3. Paint front and backsides of access panels, removable or hinged covers, and similar hinged items to match exposed surfaces. 4. Do not paint over labels of independent testing agencies or equipment name, identification, performance rating, or nomenclature plates. 5. Primers specified in painting schedules may be omitted on items that are factory primed or factory finished if acceptable to topcoat manufacturers. B. Tint each undercoat a lighter shade to facilitate identification of each coat if multiple coats of same material are to be applied. Tint undercoats to match color of topcoat, but provide sufficient difference in shade of undercoats to distinguish each separate coat. C. If undercoats or other conditions show through topcoat, apply additional coats until cured film has a uniform paint finish, color, and appearance. D. Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brush marks, roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color breaks. 3.4 CLEANING AND PROTECTION A. At end of each workday, remove rubbish, empty cans, rags, and other discarded materials from Project site. B. After completing paint application, clean spattered surfaces. Remove spattered paints by washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces. INTERIOR PAINTING 099123-5

C. Protect work of other trades against damage from paint application. Correct damage to work of other trades by cleaning, repairing, replacing, and refinishing, as approved by Architect, and leave in an undamaged condition. D. At completion of construction activities of other trades, touch up and restore damaged or defaced painted surfaces. 3.5 INTERIOR PAINTING SCHEDULE A. Concrete Substrates, Nontraffic Surfaces: 1. Institutional Low-Odor/VOC Latex System: a. Prime Coat: Primer sealer, interior, institutional low odor/voc, MPI #149. b. Intermediate Coat: Latex, interior, institutional low odor/voc, matching topcoat. c. Topcoat: Latex, interior, institutional low odor/voc, semi-gloss (Gloss Level 5), MPI #147. B. Concrete Substrates, Traffic Surfaces: 1. Latex Floor Enamel System: a. Prime Coat: Floor paint, latex, low gloss (maximum Gloss Level 3), MPI #60. b. Intermediate Coat: Floor paint, latex, low gloss (maximum Gloss Level 3), MPI #60. c. Topcoat: Floor paint, latex, low gloss (maximum Gloss Level 3), MPI #60. C. Clay-Masonry Substrates: 1. Institutional Low-Odor/VOC Latex System: D. CMU Substrates: a. Prime Coat: Primer sealer, interior, institutional low odor/voc[, MPI #149]. b. Intermediate Coat: Latex, interior, institutional low odor/voc, matching topcoat. c. Topcoat: Latex, interior, institutional low odor/voc, semi-gloss (Gloss Level 5)[, MPI #147]. 1. Institutional Low-Odor/VOC Latex System: E. Steel Substrates: a. Block Filler: Block filler, latex, interior/exterior, MPI #4. b. Intermediate Coat: Latex, interior, institutional low odor/voc, matching topcoat. c. Topcoat: Latex, interior, institutional low odor/voc, semi-gloss (Gloss Level 5), MPI #147. 1. Institutional Low-Odor/VOC Latex System: a. Prime Coat: Primer, rust-inhibitive, water based MPI #107. INTERIOR PAINTING 099123-6

b. Intermediate Coat: Latex, interior, institutional low odor/voc, matching topcoat. c. Topcoat: Latex, interior, institutional low odor/voc, semi-gloss (Gloss Level 5), MPI #147. F. Galvanized-Metal Substrates: 1. Institutional Low-Odor/VOC Latex System: a. Prime Coat: Primer, galvanized, water based, MPI #134. b. Intermediate Coat: Latex, interior, institutional low odor/voc, matching topcoat. c. Topcoat: Latex, interior, institutional low odor/voc, semi-gloss (Gloss Level 5), MPI #147. G. Elevator Door Frames: a. Prime Coat: 1 Coat Scuffmaster Primemaster Bonding Primer b. Intermediate Coat: ScrubTough Performance Paint with Microban c. Topcoat: ScrubTough Performance Paint with Microban H. Gypsum Board Substrates: 1. Institutional Low-Odor/VOC Latex System: a. Prime Coat: Primer sealer, interior, institutional low odor/voc, MPI #149. b. Intermediate Coat: Latex, interior, institutional low odor/voc, matching topcoat. c. Topcoat: Latex, interior, institutional low odor/voc, semi-gloss (Gloss Level 5), MPI #147. 2. Pre-Catalyzed Waterbased Epoxy (at Elevator Lobby Walls): a. Prime Coat: ProMar 200 Primer b. Intermediate Coat: Pro Industrial Pre-Catalyzed Epoxy c. Intermediate Coat: Pro Industrial Pre-Catalyzed Epoxy END OF SECTION 099123 INTERIOR PAINTING 099123-7

This Page Left Intentionally Blank