Vertical Siding. With a Minimum 12-inch Eave Overhang. Vertical Joints formed by Expressed Seam Joints

Similar documents
LP SmartSide Perfection Shingle

application instructions

Architectural Details and Technical Guide

The HardieZone System: HZ5 Care and Maintenance Guide

The HardieZone System: HZ5 Care and Maintenance Guide

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

APPLICATION INSTRUCTIONS REALSIDE TM

Resysta Wall Cladding Installation Guidelines

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS, INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

Architectural Specifications

Siding and Soffit Installation Guidelines

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

Architectural Specifications

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

GA APPLICATION OF GYPSUM SHEATHING

Siding and Soffit Installation Guidelines

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DuPont RainVent Batten Installation Guidelines

Architectural Specifications Nichiha Fiber Cement Products Block Panels

Appendix A. Additional Information RAINSCREENS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

Appendix A. Additional Information RAINSCREENS

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE

LP OSB Sheathing & Structural 1 Sheathing

1. Opinion. 2. Description. MasterFormat: Evaluation issued: Re-evaluated: Evaluation revised:

Stone and Masonry Veneer

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

A. Meet at Project site <insert number> days before starting installation.

The better way to build TM. Installation Manual NAILBASE PANELS

SECTION Fiber Reinforced Stucco 1

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Architectural Wall Products Guide Specifications

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

Gold Bond BRAND Gypsum Sheathing

ICC-ES Evaluation Report Reissued November 2014 This report is subject to renewal November 2016

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation

Installation Guidelines

CEMENT BACKERBOARD FOR TILE AND STONE INSTALLATION GUIDE OUR GUIDE TO INSTALLING CEMENT BACKERBOARD DO IT ONCE, DO IT RIGHT. TM

SSL-175. Specifications

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS, INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

DL-200. Specifications

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

Triton BK Backer Board & Tile Underlayment

Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

Rev. 07 8/15 Please Read Disclaimers:

DuraLife Capped Composite Decking Installation Instructions

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

SECTION METAL ROOF AND SOFFIT PANELS

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

Technical Data Sheet

SECTION FIBER CEMENT SIDING. A. Furnish and install CERACLAD fiber cement rain screen siding system.

Exterior System installation instructions

Standard Specification For Installation of ARMOROC PANEL For Roofs 1. GENERAL 1.01 SUMMARY OF WORK 1.02 DESCRIPTION OF ARMOROC PANEL

Engineering Services Program

Rev. 08 9/15 Please Read Disclaimers:

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

INSTALLATION GUIDE.

BENJAMIN OBDYKE INCORPORATED

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

LUX Specifications. Section S - Preformed Steel Siding

INSTALLATION GUIDE EPS FOAM

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

~ 100 R~~UU~]ION ~ 9RIMIOS Most Wiael>: AcceBtedana Trusted

The GlasRoc Shaftliner Type X advantage...

GAF EnergyGuard Polyiso Wall Sheathing

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

Roofing City of Owatonna BUILDING DEPARTMENT

ALLMET CONTINENTAL INSTALLATION GUIDE

CS-100 Guide Specifications

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

Classic and NB Tile Counter Batten and Batten

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PRODEMA USA INC. EVALUATION SUBJECT:

WEIGHT PER PIECE (LBS.)

Contents. ZIP System R-Sheathing

Envelope Highlights Mandatory Measures Prescriptive High Performance Walls 150.1

Multi-Institutional Academic Health Science & Research Center Evansville, IN

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

KNIGHT WALL SYSTEMS GUIDE DETAILS:

USG Tile & Flooring Solutions. USG DUROCK BRAND CEMENT BOARD WITH EDGEGUARD Installation Guide

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

Code Compliance Research Report CCRR-0228

Transcription:

Vertical Siding MULTI-FAMILY / COMMERCIAL INSTALLATION REQUIREMENTS - PRIMED & COLORPLUS PRODUCTS SMOOTH CEDARMILL SELECT SIERRA 8 STUCCO DECEMBER 205 Visit www.jameshardiecommercial.com for the most recent version. IMPORTANT: FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. TO DETERMINE WHICH HARDIEZONE PRODUCT APPLIES TO YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL -866-942-7343 (866 9HARDIE) STORAGE & HANDLING: Store flat and keep dry and covered prior to installation. Installing product wet or saturated may result in shrinkage at butt joints. Carry product on edge. Protect and corners from breakage. James Hardie is not responsible for damage caused by improper storage and handling of the product. OUTDOORS. Position cutting station so that wind will blow dust away from user and others in working area. 2. Use one of the following methods: a. Best: i. Score and snap ii. Shears (manual, electric or pneumatic)* b. Better: Dust reducing circular saw CUTTING INSTRUCTIONS * equipped with a HardieBlade saw blade and vacuum dust extraction c. Good: Circular saw with a HardieBlade saw blade (for low to cutting volume) * Shears and score/snap methods may not be suitable for products thicker than /2 in. INDOORS. NEVER cut with power saws indoors 2. Cut only using score and snap, or shears (manual, electric or pneumatic). 3. Position cutting station in well-ventilated area NEVER dry sweep Use wet suppression or vacuum NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures. Additional exposure information is available at www.jameshardie.com to help you determine the most appropriate cutting method for your job requirements. If concern still exists about exposure levels or you do not comply with the above practices, you should always consult a qualified industrial hygienist or the manufacturer for further information. SD08305 GENERAL REQUIREMENTS: Refer to table for James Hardie s multifamily/commercial requirements. References to the 2005 National Building Code (NBC) of Canada are made throughout this document. Local building code requirements may supersede the NBC in some locations. Where local building code requires a capillary break (Rainscreens, Furring, Etc.), fastener specifications per the CCMC can still be used as long as the required fastener penetration is achieved into an approved nailable substrate. A barrier is required in accordance with local building code requirements. The barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. James Hardie does market HardieWrap Weather Barrier, a non-woven non-perforated housewrap¹, which complies with building code requirements. Information on installing James Hardie products over foam can be located in JH Tech Bulletin 9 at www.jameshardie.com. Do not install James Hardie products, such that they may remain in with standing water. vertical may be installed on vertical wall applications only. DO NOT use vertical in Fascia or Trim applications. The designer and/or architect shall take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin #8 Expansion Characteristics of James Hardie Siding Products at www.jameshardiecommercial.com. Table : Siding Wall Drainage Requirements Exterior Wall Drainage Requirements With a Minimum 2-inch Eave Overhang Without a Minimum 2-inch Eave Overhang Building Height (Stories) formed by: Board and Batten; Moderate Contact; Caulk formed by Expressed Seam Joints formed by: Board and Batten; Moderate Contact; Caulk formed by Expressed Seam Joints James Hardie Panel Products > 30% of Building's Total Exterior Wall Covering 7 story building 6 story building 5 story building 4 story building 3 story building 2 story building story building WRB Rainscreen (min. 3/8 in. air gap) 3 James Hardie Panel Products 30% of Building's Total Exterior Wall Covering 7 story building 6 story building 5 story building 4 story building 3 story building 2 story building story building WRB Drainage Plane (e.g. drainable WRB) with 90% efficiency 2 Rainscreen (min. 3/8 in. air gap) 3 Water-resistive Barrier and requirements as defined by building code. 2 Water-resistive Barrier as defined by local building code that is manufactured in a manner to enhance, must meet minimum 90% efficiency when tested in accordance with ASTM E2273 or other recognized national standards. 3 Water-resistive Barrier (WRB) as defined by building code and a minimum 3/8 in. (0mm) air space between the WRB and the panel (formed by minimum 3/8 in. furring). *DANGER: Do not breathe dust from this product. Respirable Crystalline Silica Dust causes damage to lungs and respiratory system through prolonged or repeated inhalation. Fiber cement is not a health hazard when handled or stored in its original, unaltered condition. The hazard associated with cement arises from crystalline silica present in the dust generated by activities such as cutting, rebating, drilling, routing, sawing, crushing, or otherwise abrading cement, and when cleaning up, disposing of or moving the dust. When doing any of these activities in a manner that generates dust: () follow James Hardie instructions and best practices to reduce or limit the release of dust; (2) warn others in the area to avoid the dust; (3) when using mechanical saw or high speed cutting tools, work outdoors and use dust collection equipment; and (4) if no other dust controls are available, wear a NIOSH-approved dust mask or respirator (e.g., the N 95 dust mask). Refer to the product Safety Data Sheet before use. Do not handle product until all safety precautions have been read and understood. Wash hands and face thoroughly after handling. If exposed to dust or concerned, get medical advice. If shortness of breath or other health concerns develop after exposure to dust from the product, seek medical attention. Dispose of product in accordance with local, state and national regulations. If there are no applicable regulations, dispose of in a secure or in a way that will not expose others to dust. WARNING: This product contains a chemical known to the State of California to cause cancer. For more information go to www.p65warnings.ca.gov/product. For more information : James Hardie Building Products, Inc., 23 S. LaSalle St., Suite 2000, Chicago, IL 60604 USA -888 JHARDIE www.jameshardie.com www.jhsafesite.com COM30-P/5 2/5

INSTALLATION: vertical must be joined on. Position fasteners and no closer than 50mm (2 in.). JOINT TREATMENT - Install panels in (fig. ); alternatively joints may also be covered with battens or caulked (fig. 2). Horizontal Joints - Provide positive slope at all horizontal joints (fig. 3). Refer to Table for correct installation condition Water Resistive Barrier Condition Figure min. a double at panel Drainage Plane/Wrap Condition Figure min. a double at panel Furring/Rainscreen Condition Figure furring strip** furring strip** min. * Apply caulk in accordance with caulk manufacturer s written application instructions. ** Furring as prescribed in Table. *** WRB or Drainage Plane as prescribed in Table. furring strip** a double at panel COM30-P2/5 2/5

CLEARANCES Install and trim products in compliance with local building code requirements for clearance between the bottom edge of the and the adjacent finished grade. Figure 5 bottom 52mm (6 in.) min furring strip Maintain a minimum 50mm (2 in.) clearance between James Hardie products and paths, steps and driveways. Figure 6 50mm (2 in.) min. Maintain a minimum 50mm (2 in.) clearance between James Hardie products and decking material. Figure 7 deck material joist water resistive barrier 50mm (2 in.) min. flashing furring strip ledger Do not bridge floors with. Horizontal joints should always be created between floors (fig. 0). Figure 0 Water- Resistive Barrier Horizontal Trim Sheathing Furring Framing Flooring Step flashing Self-adhering membrane Housewrap Note: Furring shown is as a best practice or as prescribed per Table. Self-adhering eaves membrane Kickout flashing Drip edge At the juncture of the roof and vertical surfaces, flashing and counterflashing shall be installed per the roofing manufacturer s instructions. A minimum 50mm (2 in.) clearance between the roofing and the bottom edge of the and trim. Figure 8 50 mm (2 in.) min. 25mm ( in.) Maintain a 6mm (/4 in.) clearance between the bottom of James Hardie products and horizontal flashing. gap. (refer to figure 3 on page 2) Maintain a minimum 25mm ( in.) gap between gutter end caps and & trim. Figure 9 gutter and end cap fascia KICKOUT FLASHING Because of the volume of water that can pour down a sloped roof, one of the most critical flashing details occurs where a roof intersects a sidewall. The roof must be flashed with step flashing. Where the roof terminates, install a kickout to deflect water away from the. It is best to install a self-adhering membrane on the wall before the subfascia and trim boards are nailed in place, and then come back to install the kickout. Figure, Kickout Flashing. To prevent water from dumping behind the and the end of the roof intersection, install a "kickout" as required by IRC code R905.2.8.3 : flashing shall be a min. of 4 in. high and 4 in. wide. James Hardie recommends the kickout be angled between 00-0 to maximize water deflection GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot-dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie products near the ocean, large bodies of water, or in very humid climates. Consult applicable code compliance report for correct fastener type and placement to achieve specific design wind loads. NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. Drive fasteners perpendicular to and framing. Fastener heads should fit snug against (no air space). (fig. A) Do not over-drive nail heads or drive nails at an angle. If nail is countersunk, fill nail hole and add a nail. (fig. B) For wood framing, under driven nails should be hit flush to the plank with a hammer (for steel framing, remove and replace nail). NOTE: Whenever a structural member is present, should be fastened with even spacing to the structural member. The tables allowing direct to OSB or plywood should only be used when traditional framing is not available. Do not use aluminum fasteners, staples, or clipped head nails Note: When utilizing express seam joints ensure adequate nailable substrate width is available. Figure A Figure B CUT EDGE TREATMENT Caulk, paint or prime all field cut. James Hardie touch-up kits are required to touch-up ColorPlus products. BLOCKED PENETRATIONS Penetrations such as hose bibs and holes ½ in. or larger such as dryer vents shall have a block of trim around point of penetration. PNEUMATIC FASTENING James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer; does not apply for installation to steel framing). CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher, such as Quad Max or a Latex Joint Sealant complying with ASTM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer s written instructions. DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section. PAINTING DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie Products. James Hardie products must be painted within 80 days for primed product and 90 days for unprimed. 00% acrylic topcoats are recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back-rolling is recommended if a paint sprayer is used. COM30-P3/5 2/5

COMPLIANCE: vertical complies with ASTM Specification C86 (Grade II, Type A) and ISO Standard 8336 (Category 3, Type A). When tested in accordance with CAN/ULC-S02, the product is recognized to have the following properties: Flame Spread Rating: 0, Smoke Developed Classification: 0. When tested in accordance with CAN/ULC-S4, the product is recognized as noncombustible. RECOGNITION: vertical may be recognized as an alternative to exterior wall cladding in section 9.27 of the NBC. For technical assistance, call -800-9-HARDIE. FIRE-RESISTIVE CONSTRUCTION: vertical is recognized as a component in -hour fire-related wall construction. Details of this assembly (Design No. JH/WA 60-0, JH/WA 60-09 and JH/WA 60-0) may be found at: www.intertek-etlsemko.com ALLOWABLE LOADS FOR STRUCTURAL EXTERIOR HARDIEPANEL VERTICAL SIDING PRODUCT THICKNESS FASTENER TYPE FASTENER SPACING FRAME TYPES MAXIMUM STUD SPACING SHEAR VALUE (knm) (plf) ULTIMATE LOAD@FAILURE (kpa) (psf) 2.3mm shank x 5.7mm HD 38mm ( /2 in.) ring shank nail 02mm (4 in.) - edge/ 2 (6 in.) 2.92 200 4.30 90 50mm (6 in.) - edge/ 305mm (2 in.) - field (6 in.) 2.29 57 4.26 89 50mm (6 in.) - edge/ 50mm (6 in.) - field (6 in.) 2.92 200 7.3 49 02mm (4 in.) - edge/ 02mm (4 in.) - field (6 in.) 3.25 223 2.30 236 50mm (6 in.) - edge/ 305mm (2 in.) - field 60mm 2.2 46 2.82 59 50mm (6 in.) - edge/ 50mm (6 in.) - field 60mm 2.23 53 4.5 94 02mm (4 in.) - edge/ 02mm (4 in.) - field 60mm 2.23 53 4.85 43 Min No. 8-8 x 8.2mm HD x 25mm ( in.) long Hi-Lo S or S-2 ribbed bugle screws 50mm (6 in.) - edge/ 50mm (6 in.) - field metal C- (6 in.) 2.33 60 8.4 70 2.5mm shank x 6.2mm HD x 38mm ( /2 in.) long ET & F pin fastener 02mm (4 in.) - edge/ metal C- (6 in.) 2.25 54 8.4 70 2.5mm shank x 6.2mm HD x 38mm ( /2 in.) long ET & F pin fastener 02mm (4 in.) - edge/ metal C- 60mm.94 33 4.84 0 WIND LOAD TABLE FOOT NOTES:. Values are for species of wood having a specific gravity of 0.42 or greater. 2. Values are for species of wood having a specific gravity of 0.36 or greater. METRIC TO IMPERIAL CONVERSION TABLE The following table provides a conversion of the nominal metric measurements presented in these installation instructions to nominal Imperial fraction measurement values 2.3 3/32 6.7 7/64 25 50 6 2.5 3/32 7.5 5/6 38 -/2 203 8 2.8 7/64 8.2 2/64 50 2 305 2 5.7 7/32 9 23/64 92 3-5/8 406 6 6.2 /4 2 5/32 02 4 60 24 COM30 - P4/5 2/5

COLORPLUS TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE Care should be taken when handling and cutting James Hardie ColorPlus products. Laminate sheet must be removed immediately after installation of each course. Gently wipe any residue or construction dust left on the product using a soft cloth. Touch up nicks, scrapes and nail heads using the ColorPlus Technology touch-up applicator. Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new with ColorPlus Technology. Terminate non-factory cut into trim where possible, and caulk. Color matched caulks are available from your ColorPlus product dealer. Treat all other non-factory cut using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer. Note: Use of touch-up on fasteners on the face of ColorPlus panels should be avoided. joint between ColorPlus panels. Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up, will not be covered under the James Hardie ColorPlus Limited Finish Warranty. Not all designs will be suitable forevery application. PAINTING JAMES HARDIE SIDING AND TRIM PRODUCTS WITH COLORPLUS TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: Ensure the surface is clean, dry, and free of any dust, dirt, or mildew Repriming is normally not necessary 00% acrylic topcoats are recommended DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie Products. Apply finish coat in accordance with paint manufacturer s written instructions regarding coverage, application methods, and application temperature RECOGNITION: In accordance with ICC-ES Evaluation Report ESR-844, vertical is recognized as a suitable alternate to that specified in: the 2006.2009, & 202 International Residential Code for One-and Two-Family Dwellings and the 2006, 2009, & 202 International Building Code. vertical is also recognized for application in the following: City of Los Angeles Research Report No. 24862, State of Florida listing FL#889, Dade County, Florida NOA No. 02-0729.02, U.S. Dept. of HUD Materials Release 263c, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA 223-93-M, and California DSA PA-09. These documents should also be consulted for additional information concerning the suitability of this product for specific applications. 205 James Hardie Building Products Inc. All rights reserved. TM, SM, and denote trademarks or registered trademarks of James Hardie Technology Limited. The QUAD mark is a registered trademark owned by Henkel Corporation. Additional Installation and Warranty information available at www.jameshardie.com COM30 - P5/5 2/5