EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration

Similar documents
EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration

Built for Better Testing. EZ-Fit Filtration Units: Convenience without compromise. Data Sheet

MicroFunnel Filter Funnels

Microfil Filtration System

Microfil Filtration System

Streamline your microbial detection workflow with the Milliflex platform.

Swab and Samplers Test Kits Quality control as easy as 1, 2, 3

Streamline your microbial detection workflow with the Milliflex platform.

Microbial Media and Culture Dishes

Your Goal is Zero Positives. So is Ours.

Monitoring the quality of beverages, water and foods...

Monitoring the quality of beverages, water and foods

Heterotrophic Bacteria

Swab and Samplers Test Kits Quality control as easy as 1, 2, 3

Membrane Solutions is manufacturer

USEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.

Method 9.2 Drinking water and effluent: bacteria by the membrane filter method

EZ-Fluo System. For rapid detection of spoilage organisms in wine

Milliflex Rapid Microbiology Detection System

Air monitoring around the world.

Plastic Storage Bottles Product Selection Guide

COMPARING THE ANTIMICROBIAL ACTIVITY OF THE SEMCO 3A TOTAL ENERGY WHEEL WITH OTHER SELECTED ANTIMICROBIAL SURFACE TREATMENTS RESEARCH FINDINGS

1. Low profile units 2 Normal profile sterilisation filter units 3. Each pack includes 12 glass-fibre prefilters

Microbial Monitoring. Gusmer Enterprises April 2013

Polysep II Filters. Superior filters provide multiple filtration stages in a single compact configuration for critical prefiltration applications

At Your ServIce. Microbiology Services. The life science business of Merck operates as MilliporeSigma in the U.S. and Canada.

Tissue Culture Products

COLIFORM FILTERS. All filters listed on this page are white with black grids, 47 mm diameter, sterile.

Coliforms, Total and E. coli

Validation Guide for and

Milligard Filters. Superior filters for critical prefiltration applications. Benefits. Data Sheet. Data Sheet

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum

A Top Tip System! H I G H - T E C H D I S P O S A B L E S

Monitoring the quality of drinking water

DAIRY WATERS. (Coliform Group and Escherichia coli) [E. coli verification required only on source water] IMS #24

RiOs Essential 5, 8, 16, 24 Water Purification Systems

Sterisart BD Media and Fluids One-Stop Shopping for Sterility Testing

FlexReady Solution for Clarification. Mobius. Fast setup. Maximum adaptability. Pre-designed and optimized.

Microscale Gas Chemistry, Part 29. The Mini-Ozone Generator and Bacteria

Monitoring the quality of drinking water

Biocidal Surface Test - Clinell Wipes ~ Project Report Prepared for GAMA Healthcare Ltd ~ Huddersfield Microbiology Services Oct 06

Cell Culture Flasks DATA SHEET

Biocontamination control in pharmaceutical production

Microbiological tests not just for safe drinking water. PRACTICE REPORT MICROBIOLOGY Author: Dr. Elmar Grabert, HACH LANGE GmbH, Germany

Synchronized solutions for food and beverage testing

Microbiological Methods

Supor PES Membrane Disc Filters

RiOs 3, 5, 8 Water Purification Systems

Viresolve Pro Solution

RiOs 3, 5, 8 Water Purification Systems

SOUTH AFRICAN NATIONAL STANDARD

Claristep Filtration System The Easy Choice Syringeless and Fast

A Hands-On Guide to Ultrafiltration/ Diafiltration Optimization using Pellicon Cassettes

Cell Culture Solutions. Tough problems require innovative Solutions from Corning

MicroVantage MAN Series

Guideline Landscape. Quality Control

Make the invisible visible HY-LiTE Plus.

Microbiological Quality: Understanding Drinking Water Quality and Management

BD PhaSeal System. Product Catalog

Originally released 12/2017 with proposed compliance date extension and equivalent methods Updated 07/2018 to include FDA updates to equivalent

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

Merck Millipore BioMonitoring

BIO & PHARMA ANALYTICAL TECHNIQUES

Milli-Q Reference Water Purification System

mdi Filters for Pharmaceutical and Biological

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

Microbiology. Sample collection, cultivation, processing

Synchronised solutions for cell culture

Millistak+ Pod carbon depth filter media system

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

General Protocol. Solutions.

Nunc EasyFill Cell Factory system

Simply get started! Ready-to-Use culture media from Merck

COUNT METHOD 5.0 OBJECTIVES 5.1 INTRODUCTION 5.2 PRINCIPLE. Structure

The Opta SFT-D is available as individual device for end-user assembly with TPE tubing and autoclave sterilization.

Microsart e.motion Filter Dispensers Make Membranes Move

Milliflex Quantum Detection of microbial contaminants in water samples

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

BiOstic Paraffin Removal Reagent

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

Finally, You Have a Choice! Online Ordering Available

Hamilton PRP Polymeric Columns

Lab Activity #14 - Bacteriological Examination Of Water and Milk (Adapted from Lab manual by Dr. Diehl)

Standing Committee of Analysts

Core Cell Culture Product Training

MICROBIOLOGICAL TOOLS FOR QUALITY ASSURANCE IN HATCHERY: Laboratory Methods

Microbiological Methods

Falcon Multi-Flask FEATURES:

DPTE -EN 1 DPTE TRANSFER SYSTEM THE GLOBAL REFERENCE

Reflectoquant System. Easy in-process monitoring for food & beverages.

Filtration in Preparation of Cell Culture Media and Buffers

Lifegard. Filters. Lenntech Tel Fax

You Can Always Get What You Want. PCR Consumables from Eppendorf

Sanitization and endotoxin clearance in AxiChrom columns

TRANSFER OF BACTERIA USING ASEPTIC TECHNIQUE

Validation Guide Sterisart NF

Validation Guide Sterisart NF

You can always get what you want

Standard Flexel 3D bioprocessing bags for Palletank (US and Canada)

METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES. NOTE: This method does not include all of the

Transcription:

EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration EMD Millipore is a division of Merck KGaA, Darmstadt, Germany

Ready-to-use sterilized filtration devices for microbial enumeration The EZ-Fit Filtration Unit is a disposable filtration device for Bioburden testing of liquid samples including water, in-process samples, and final products. It is designed for optimizing and securing the laboratory workflow to save time and provide reliable microbiological results. After the filtration of the sample, the membrane can be transferred to an agar plate to culture the captured organisms. Alternatively, liquid media can be added after the filtration, and the device converts into a Petri dish. Cover Funnel EZ-Fit Filtration Units comprise a range of products to fit to various applications: 100 ml funnels or 250 ml funnels Black or white gridded membranes Units are either individually bagged or packaged in bulk. Membrane Support pad Base Designed for optimal microbial recovery The EZ-Fit Filtration Unit has been designed to ensure optimal microbial recovery. The drain support and the funnel-to-base assembly have been optimized so that the membrane is perfectly flat after the sample filtration. When transferred to the culture media, the whole filtration surface of the membrane is in perfect contact with the culture media. No folds or membrane waves ensures optimal microbial recovery. EZ-Fit Filtration Unit components The shape of the funnel and the plastic material minimize sample residue ensuring that the complete sample volume reaches the membrane surface. The innovative funnel assembly design prevents any leaks or sample by-pass of the membrane, meaning that the whole sample volume is filtered. The EZ-Fit Filtration Units conform to inter national standards (EP/ USP) and comply with water testing regulations. Funnel design minimizes residual liquid and prevents sample by-pass Drain support ensures membrane shape for perfect contact with media and optimal microbial recovery 2

Reduced risk of contamination It is important to choose a filtration device that protects your sample from contamination during processing. The design of the EZ-Fit Filtration Unit helps you avoid contamination by reducing the risk of accidentally touching the membrane filtration area with forceps during membrane transfer and by allowing you to filter with the lid in place. A rim stops the forceps from coming into contact with the membrane filtration area Vented lid on the device during filtration Efficient laboratory workflow EMD Millipore has worked with membrane filtration users worldwide and across industries to develop the EZ-Fit Filtration Unit. Taking into consideration user requirements and ergonomic improvements, EMD Millipore has developed a filtration unit which brings a new standard for Easy to Use. Clear, transparent funnel material for visualizing the end of the filtration from any angle. All around level indicators mean there is no need to turn the funnel when placing it on the filtration support. Membrane base shape facilitates membrane transfer with forceps. Funnel assembly allows one-handed funnel removal. 250 ml funnels are ideal for larger volume samples. Units are stackable to conserve space in the working area. Convenient see-through funnel and all-around volume indications Units can be stacked to conserve space in the working area 3

EZ-Fit Manifold designed for EZ-Fit Filtration Units The EZ-Fit Manifold allows access to easily clean all internal areas in order to ensure the filtration process is contamination-free. Each component can be removed by hand and autoclaved. Quick-fit connections for the vacuum tubing and low manifold height improve the ease of use. A specific filtration head fits the EZ-Fit Filtration Unit, enabling the removal of the funnel with one hand. The EZ-Fit Filtration Unit fits perfectly to the manifold One handed funnel removal EZ-Fit Filtration Unit can also be used with liquid media in ampoules After the sample filtration step, the membrane can be transferred to agar media for cultivation. Alternatively, liquid media can be added from the top. The funnel is then removed and the unit converts to a Petri dish ready for incubating. Liquid media 4 Petri dish

Technical specifications Material of construction Cover Funnel Membrane Support pad Base Plug Dimensions Height Largest diameter Filtration surface 12.56 cm 2 Sterilization method Ethylene oxide (EO) Polystyrene Styrene butadiene copolymer (SBC) Mixed cellulose esters Cellulose Acrylonitrile butadiene styrene Low-density polyethylene 100 ml: 66.5 mm (2.6 in.) 250 ml: 108.5 mm (4.3 in.) 75.8 mm (3.0 in.) Ordering Information Filtration Units, Hardware and Accessories Description Qty / Pk Catalog No. EZ-Fit Filtration Units White membrane, 0.45 µm pore size, 100 ml funnel, bulk packaging 48 EFHAW100B Black membrane, 0.45 µm pore size, 100 ml funnel, bulk packaging 48 EFHAB100B White membrane, 0.45 µm pore size, 100 ml funnel, individual packaging 48 EFHAW100I Black membrane, 0.45 µm pore size, 100 ml funnel, individual packaging 48 EFHAB100I White membrane, 0.45 µm pore size, 250 ml funnel, bulk packaging 48 EFHAW250B Black membrane, 0.45 µm pore size, 250 ml funnel, bulk packaging 48 EFHAB250B White membrane, 0.45 µm pore size, 250 ml funnel, individual packaging 48 EFHAW250I Black membrane, 0.45 µm pore size, 250 ml funnel, individual packaging 48 EFHAB250I EZ-Fit Manifolds, Accessories, Filtration pump EZ-Fit Manifold, 1-place for EZ-Fit Filtration Units 1 EZFITEFUN1 EZ-Fit Manifold, 3-place for EZ-Fit Filtration Units 1 EZFITEFUN3 EZ-Fit Manifold, 6-place for EZ-Fit Filtration Units 1 EZFITEFUN6 EZ-Fit filtration head for EZ-Fit Filtration Units 1 EZFITMVHE1 EZ-Fit filtration head for EZ-Fit Filtration Units 3 EZFITMVHE3 EZ-Fit adapter for using EZ-Fit Filtration Units on Microfil Manifolds 3 EZFITMICAD EZ-Fit filtration head gasket 3 EZFITMVG3 EZ-Stream Vacuum Pump for liquid transfer 1 EZSTREAM1 Silicone tubing for EZ-Stream Vacuum Pump 1 STREAMTUB Ready to use 2 ml single test Liquid Media in plastic ampoules m-green Yeast and Mold Broth 50 MHA000P2M m-fc Broth with Rosolic Acid 50 MHA000P2F m-endo Total Coliform Broth 50 MHA000P2E Tryptone Glucose Extract Broth (TGE) 50 MHA000P2T m-coliblue24 Broth for Total coliforms and E coli detection 50 M00PMCB24 m-hpc broth 50 MHA000P2S Triptic Soybean Broth (TSB) 50 MHA000T2B Tryptone Glucose Extract Broth with TTC 50 MHA00P2TT Preservative Resistant Yeast Broth 50 MHA00PRY2 5

For technical service please visit: www.emdmillipore.com/techservice EMD Millipore Corporation 290 Concord Rd. Billerica, MA 01821, USA In the United States: For customer service, call 1-800-766-7000 To fax an order, use 1-800-926-1166 To order online: www.fishersci.com In Canada: For customer service, call 1-800-234-7437 To fax an order, use 1-800-463-2996 To order online: www.fishersci.ca EMD Millipore, the M logo and Chromocult are registered trademarks of Merck KGaA, Darmstadt, Germany. EZ-Fit and EZ-Stream are trademarks of Merck KGaA, Darmstadt, Germany. All other trademarks are the property of their respective owners. W.260917 Fisher Lit. No. BN1009143 02/2015 BM-15-11020 Printed in the USA. 2015 EMD Millipore Corporation, Billerica, MA 01821, U.S.A. All rights reserved. We provide information and advice to our customers on application technologies and regulatory matters to the best of our knowledge and ability, but without obligation or liability. Existing laws and regulations are to be observed in all cases by our customers. This also applies in respect to any rights of third parties. Our information and advice do not relieve our customers of their own responsibility for checking the suitability of our products for the envisaged purpose.