HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Similar documents
GYPSUM BOARD AND PLASTER

Stone and Masonry Veneer

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

SECTION GYPSUM BOARD

GA APPLICATION OF GYPSUM SHEATHING

SPECIFICATION GUIDELINE

SECTION Fiber Reinforced Stucco 1

Code Compliance Research Report CCRR-0231

City of Long Beach Department of Development Services Building and Safety Bureau. Design Limitation for Wood Shear Walls

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

SPECIFICATION GUIDELINE

EDGEWATER, FLORIDA JUNE 14, 2010

RLGA. Gypsum Board Construction 2012 International Building Code. By Ronald L. Geren, AIA, CSI, CCS, CCCA, SCIP

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

R-Matte Plus-3: Insulation for the Building Envelope

ICC-ES Evaluation Report Reissued November 2014 This report is subject to renewal November 2016

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

SECTION PORTLAND CEMENT PLASTER (STUCCO) WITH ACRYLIC FINISH

Technical Bulletin. CTIOA Technical Committee

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

Gold Bond BRAND Gypsum Sheathing

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

SECTION GYPSUM BOARD

SECTION PORTLAND CEMENT PLASTERING

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

The better way to build TM. Installation Manual NAILBASE PANELS

SECTION NON-STRUCTURAL METAL FRAMING

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

SECTION GYPSUM BOARD ASSEMBLIES

REPORT HOLDER: GYPSUM ASSOCIATION 962 WAYNE AVENUE, SUITE 620 SILVER SPRING, MARYLAND EVALUATION SUBJECT:

JC Code & Construction Consultants, Inc. Advanced Training: The FBC & ASTM C 1063

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

STRENGTH AND DURABILITY OF THE INSTALLED STONE

Installation Standard For TILE-LINED ROMAN BATH TUBS IAPMO IS (10) Wall Finish. (3) Test Required. (2) Waterproof. Tile. (8) Concrete Shell

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: MATERIAL DISTRIBUTOR COMPANY, INC.

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA

Multi-Institutional Academic Health Science & Research Center Evansville, IN

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

CONCRETE MASONRY VENEERS TEK 3-6C

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD ASSEMBLIES

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

REPORT HOLDER: GYPSUM ASSOCIATION 6525 BELCREST ROAD #480 HYATTSVILLE, MARYLAND EVALUATION SUBJECT:

Section Metal Lath and Accessories

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC

ESR-2771 Reissued December 1, 2013 This report is subject to renewal December 1, 2014.

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

ICC-ES Evaluation Report Reissued April 1, 2010 This report is subject to re-examination in two years.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

Ash Brook Golf Course Scotch Plains, New Jersey

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 301

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Product Specification

Building Division Informational Handout

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

GAF EnergyGuard Polyiso Wall Sheathing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: BASF CORPORATION WALL SYSTEMS

SECTION CEMENTITIOUS SHEATHING

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

SECTION GYPSUM BOARD ASSEMBLIES

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. Section Includes: 1. Patching of exterior portland cement plasterwork (stucco) on metal lath.

Stucco and EIFS Wall Systems

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: AMERICAN EAGLE MATERIALS, LLC

SECTION NON--STRUCTURAL METAL FRAMING

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

SECTION BRICK MASONRY ASSEMBLIES

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: BONSAL AMERICAN, INC.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

Construction Standards PAGE

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

Inspection Fundamentals: Stucco & EIFS

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

GYPSUM BOARD

1. Interior gypsum board. 2. Glass-mat gypsum sheathing board for ceilings and soffits. 3. Cement board. 4. Sound attenuation blankets

DIVISION: CONCRETE SECTION: CEMENTITIOUS WOOD FIBER DECKS DIVISION: FINISHES SECTION: ACOUSTIC ROOM COMPONENTS

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

Transcription:

CALIFORNIA BUILDING CODE MATRIX ADOPTION TABLE CHAPTER 25 GYPSUM BOARD AND PLASTER (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building applications.) Adopting agency BSC SFM HCD DSA OSHPD 1 2 1/AC AC SS SS/CC 1 2 3 4 Adopt entire chapter X X X X Adopt entire chapter as amended (amended sections listed below) X X Adopt only those sections that are listed below Chapter / Section 2501.2 X X X X 2503.2 X X X X 2504.2 X X X X 2504.2.1 X X X X 2505.3 X X X X 2507.3 X X X X 2508.5.6 X X X X BSCC DPH AGR DWR CEC CA SL SLC The Office of the State Fire Marshal s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11. 2013 CALIFORNIA BUILDING CODE JANUARY 1, 2014 ERRATA 379 BUFF

380 JANUARY 1, 2014 ERRATA 2013 CALIFORNIA BUILDING CODE BUFF

CHAPTER 25 GYPSUM BOARD AND PLASTER 2501.1 Scope. SECTION 2501 GENERAL 2501.1.1 General. Provisions of this chapter shall govern the materials, design, construction and quality of gypsum board, lath, gypsum plaster and cement plaster. 2501.1.2 Performance. Lathing, plastering and gypsum board construction shall be done in the manner and with the materials specified in this chapter, and when required for fire protection, shall also comply with the provisions of Chapter 7. 2501.1.3 Other materials. Other approved wall or ceiling coverings shall be permitted to be installed in accordance with the recommendations of the manufacturer and the conditions of approval. 2501.2 Additional requirements. [DSA-SS, DSA-SS/CC and OSHPD 1 & 4] Details of attachment for wall and ceiling coverings which are not provided for in these regulations shall be detailed in the approved construction documents. SECTION 2502 DEFINITIONS 2502.1 Definitions. The following terms are defined in Chapter 2: CEMENT PLASTER. EXTERIOR SURFACES. GYPSUM BOARD. GYPSUM PLASTER. GYPSUM VENEER PLASTER. INTERIOR SURFACES. WEATHER-EXPOSED SURFACES. WIRE BACKING. SECTION 2503 INSPECTION 2503.1 Inspection. Lath and gypsum board shall be inspected in accordance with Section 110.3.5, Chapter 1, Division II. 2503.2 Additional requirements for inspection and testing. [DSA-S, DSA-SS/CC and OSHPD 1 & 4 ] 1. Lath and gypsum board shall be inspected in accordance with Chapter 17A and the California Administrative Code. 2. No lath or gypsum wallboard or their attachments shall be covered or finished until it has been inspected and approved by the inspector of record and/or special inspector. 3. The enforcement agency may require tests in accordance with Table 2506.2 to determine compliance with the provisions of these regulations. 4. The testing of gypsum and gypsum products shall conform with standards listed in Table 2506.2 SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES 2504.1 Scope. The following requirements shall be met where construction involves gypsum board, lath and plaster in vertical and horizontal assemblies. 2504.1.1 Wood framing. Wood supports for lath or gypsum board, as well as wood stripping or furring, shall not be less than 2 inches (51 mm) nominal thickness in the least dimension. Exception: The minimum nominal dimension of wood furring strips installed over solid backing shall not be less than 1 inch by 2 inches (25 mm by 51 mm). 2504.1.2 Studless partitions. The minimum thickness of vertically erected studless solid plaster partitions of 3 / 8 - inch (9.5 mm) and 3 / 4 -inch (19.1 mm) rib metal lath or 1 / 2 - inch thick (12.7 mm) long-length gypsum lath and gypsum board partitions shall be 2 inches (51 mm). 2504.2 Additional requirements. [DSA-SS, DSA-SS/CC and OSHPD 1 & 4] In addition to the requirements of this section, the horizontal and vertical assemblies of plaster or gypsum board shall be designed to resist the loads specified in this code. For suspended acoustical ceiling systems, see Section 2506. For gypsum construction see Section 2508. 2504.2.1 Wood furring strips. Wood furring strips for ceilings fastened to floor or ceiling joist shall be nailed at each bearing with two common wire nails, one of which shall be a slant nail and the other a face nail, or by one nail having spirally grooved or annular grooved shanks approved by the enforcement agency for this purpose. All stripping nails shall penetrate not less than 1 3 / 4 inches (44.5 mm) into the member receiving the point. Holes in stripping at joints shall be subdrilled to prevent splitting. Where common wire nails are used to support horizontal wood stripping for plaster ceilings, such stripping shall be wire tied to the joists 4 feet (1219 mm) on center with two strands of No. 18 W&M gage galvanized annealed wire to an 8d common wire nail driven into each side of the joist 2 inches (51 mm) above the bottom of the joist or to each end of a 16d common wire nail driven horizontally through the joist 2 inches (51 mm) above the bottom of the joist, and the ends of the wire secured together with three twists of the wire. 2013 CALIFORNIA BUILDING CODE 381

SECTION 2505 SHEAR WALL CONSTRUCTION 2505.1 Resistance to shear (wood framing). Wood-framed shear walls sheathed with gypsum board, lath and plaster shall be designed and constructed in accordance with Section 2306.3 and are permitted to resist wind and seismic loads. Walls resisting seismic loads shall be subject to the limitations in Section 12.2.1 of ASCE 7. 2505.2 Resistance to shear (steel framing). Cold-formed steel-framed shear walls sheathed with gypsum board and constructed in accordance with the materials and provisions of Section 2211.6 are permitted to resist wind and seismic loads. Walls resisting seismic loads shall be subject to the limitations in Section 12.2.1 of ASCE 7. 2505.3 [DSA-SS & DSA-SS/CC and OSHPD 1 & 4] Section 2505.1 and 2505.2 are not permitted. SECTION 2506 GYPSUM BOARD S 2506.1 General. Gypsum board materials and accessories shall be identified by the manufacturer's designation to indicate compliance with the appropriate standards referenced in this section and stored to protect such materials from the weather. 2506.2 Standards. Gypsum board materials shall conform to the appropriate standards listed in Table 2506.2 and Chapter 35 and, where required for fire protection, shall conform to the provisions of Chapter 7. 2506.2.1 Other materials. Metal suspension systems for acoustical and lay-in panel ceilings shall conform with ASTM C 635 listed in Chapter 35 and Section 13.5.6 of ASCE 7 for installation in high seismic areas. TABLE 2506.2 GYPSUM BOARD S AND ACCESSORIES STANDARD Accessories for gypsum board ASTM C 1047 Adhesives for fastening gypsum wallboard ASTM C 557 Elastomeric joint sealants ASTM C 920 Fiber-reinforced gypsum panels ASTM C 1278 Glass mat gypsum backing panel ASTM C 1178 Glass mat gypsum panel ASTM C 1658 Glass mat gypsum substrate ASTM C 1177 Joint reinforcing tape and compound ASTM C 474; C 475 Nails FOR gypsum boards ASTM C 514, F 547, F 1667 Steel screws ASTM C 954; C 1002 Steel studs, load-bearing ASTM C 955 Steel studs, nonload-bearing ASTM C 645 Standard specification for gypsum board ASTM C 1396 Testing gypsum and gypsum products ASTM C 22; C 472; C 473 SECTION 2507 LATHING AND PLASTERING 2507.1 General. Lathing and plastering materials and accessories shall be marked by the manufacturer s designation to indicate compliance with the appropriate standards referenced in this section and stored in such a manner to protect them from the weather. 2507.2 Standards. Lathing and plastering materials shall conform to the standards listed in Table 2507.2 and Chapter 35 and, where required for fire protection, shall also conform to the provisions of Chapter 7. TABLE 2507.2 LATH, PLASTERING S AND ACCESSORIES STANDARD Accessories for gypsum veneer base ASTM C 1047 Blended cement ASTM C 595 Exterior plaster bonding compounds ASTM C 932 Gypsum casting and molding plaster ASTM C 59 Gypsum Keene's cement ASTM C 61 Gypsum plaster ASTM C 28 Gypsum veneer plaster ASTM C 587 Interior bonding compounds, gypsum ASTM C 631 Lime plasters ASTM C 5; C 206 Masonry cement ASTM C 91 Metal lath ASTM C 847 Plaster aggregates Sand Perlite Vermiculite ASTM C 35; C 897 ASTM C 35 ASTM C 35 Plastic cement ASTM C 1328 Portland cement ASTM C 150 Steel screws ASTM C 1002; C 954 Steel studs and track ASTM C 645; C 955 Welded wire lath ASTM C 933 Woven wire plaster base ASTM C 1032 2507.3 Lath attachment to horizontal wood supports. [DSA- SS & DSA-SS/CC and OSHPD 1 & 4] Where interior or exterior lath is attached to horizontal wood supports, either of the following attachments shall be used in addition to the methods of attachment described in referenced standards listed in Table 2507.2. 1. Secure lath to alternate supports with ties consisting of a double strand of No. 18 W & M gage galvanized annealed wire at one edge of each sheet of lath. Wire ties shall be installed not less than 3 inches (76 mm) back from the edge of each sheet and shall be looped around stripping, or attached to an 8d common wire nail driven into each side of the joist 2 inches (51 mm) above the bottom of the joist or to each end of a 16d common wire nail driven horizontally through the joist 2 inches (51 mm) above the bottom of the joist and the 382 2013 CALIFORNIA BUILDING CODE

ends of the wire secured together with three twists of the wire. 2. Secure lath to each support with 1 / 2 -inch-wide (12.7 mm), 1 1 / 2 -inch-long (38mm) No. 9 W & M gage, ring shank, hook staple placed around a 10d common nail laid flat under the surface of the lath not more than 3 inches (76 mm) from edge of each sheet. Such staples may be placed over ribs of 3 / 8 -inch (9.5 mm) rib lath or over back wire of welded wire fabric or other approved lath, omitting the 10d nails. SECTION 2508 GYPSUM CONSTRUCTION 2508.1 General. Gypsum board and gypsum plaster construction shall be of the materials listed in Tables 2506.2 and 2507.2. These materials shall be assembled and installed in compliance with the appropriate standards listed in Tables 2508.1 and 2511.1.1, and Chapter 35. TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION STANDARD Gypsum board GA-216; ASTM C 840 Gypsum sheathing ASTM C 1280 Gypsum veneer base ASTM C 844 Interior lathing and furring ASTM C 841 Steel framing for gypsum boards ASTM C 754; C 1007 2508.2 Limitations. Gypsum wallboard or gypsum plaster shall not be used in any exterior surface where such gypsum construction will be exposed directly to the weather. Gypsum wallboard shall not be used where there will be direct exposure to water or continuous high humidity conditions. Gypsum sheathing shall be installed on exterior surfaces in accordance with ASTM C 1280. 2508.2.1 Weather protection. Gypsum wallboard, gypsum lath or gypsum plaster shall not be installed until weather protection for the installation is provided. 2508.3 Single-ply application. Edges and ends of gypsum board shall occur on the framing members, except those edges and ends that are perpendicular to the framing members. Edges and ends of gypsum board shall be in moderate contact except in concealed spaces where fire-resistancerated construction, shear resistance or diaphragm action is not required. 2508.3.1 Floating angles. Fasteners at the top and bottom plates of vertical assemblies, or the edges and ends of horizontal assemblies perpendicular to supports, and at the wall line are permitted to be omitted except on shear resisting elements or fire-resistance-rated assemblies. Fasteners shall be applied in such a manner as not to fracture the face paper with the fastener head. 2508.4 Joint treatment. Gypsum board fire-resistance-rated assemblies shall have joints and fasteners treated. Exception: Joint and fastener treatment need not be provided where any of the following conditions occur: 1. Where the gypsum board is to receive a decorative finish such as wood paneling, battens, acoustical finishes or any similar application that would be equivalent to joint treatment. 2. On single-layer systems where joints occur over wood framing members. 3. Square edge or tongue-and-groove edge gypsum board (V-edge), gypsum backing board or gypsum sheathing. 4. On multilayer systems where the joints of adjacent layers are offset from one to another. 5. Assemblies tested without joint treatment. 2508.5 Horizontal gypsum board diaphragm ceilings. Gypsum board shall be permitted to be used on wood joists to create a horizontal diaphragm ceiling in accordance with Table 2508.5. 2508.5.1 Diaphragm proportions. The maximum allowable diaphragm proportions shall be 1 1 / 2 :1 between shear resisting elements. Rotation or cantilever conditions shall not be permitted. 2508.5.2 Installation. Gypsum board used in a horizontal diaphragm ceiling shall be installed perpendicular to ceiling framing members. End joints of adjacent courses of gypsum board shall not occur on the same joist. TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES Gypsum board THICKNESS OF (MINIMUM) (inches) SPACING OF FRAMING MEMBERS (MAXIMUM) (inches) SHEAR VALUE a, b (plf of ceiling) 1 / 2 16 o.c. 90 MIMIMUM FASTENER SIZE 5d cooler or wallboard nail; 1 5 / 8 -inch long; 0.086-inch shank; 15 / 64 -inch head c Gypsum board 1 / 2 24 o.c. 70 5d cooler or wallboard nail; 1 5 / 8 -inch long; 0.086-inch shank; 15 / 64 -inch head c For SI: 1 inch = 25.4 mm, 1 pound per foot = 14.59 N/m. a. Values are not cumulative with other horizontal diaphragm values and are for short-term loading due to wind or seismic loading. Values shall be reduced 25 percent for normal loading. b. Values shall be reduced 50 percent in Seismic Design Categories D, E and F. c. 1 1 / 4 -inch, No. 6 Type S or W screws are permitted to be substituted for the listed nails. 2013 CALIFORNIA BUILDING CODE 383

2508.5.3 Blocking of perimeter edges. All perimeter edges shall be blocked using a wood member not less than 2-inch by 6-inch (51 mm by 159 mm) nominal dimension. Blocking material shall be installed flat over the top plate of the wall to provide a nailing surface not less than 2 inches (51 mm) in width for the attachment of the gypsum board. 2508.5.4 Fasteners. Fasteners used for the attachment of gypsum board to a horizontal diaphragm ceiling shall be as defined in Table 2508.5. Fasteners shall be spaced not more than 7 inches (178 mm) on center (o.c.) at all supports, including perimeter blocking, and not more than 3 / 8 inch (9.5 mm) from the edges and ends of the gypsum board. 2508.5.5 Lateral force restrictions. Gypsum board shall not be used in diaphragm ceilings to resist lateral forces imposed by masonry or concrete construction. 2508.5.6 Diaphragm ceiling connection to partitions. [DSA-SS & DSA-SS/CC and OSHPD 1 & 4] Gypsum board shall not be used in diaphragm ceilings to resist lateral forces imposed by partitions. Connection of diaphragm ceiling to the vertical lateral force resisting elements shall be designed and detailed to transfer lateral forces. SECTION 2509 GYPSUM BOARD IN SHOWERS AND WATER CLOSETS 2509.1 Wet areas. Showers and public toilet walls shall conform to Section 1210.2. 2509.2 Base for tile. Glass mat water-resistant gypsum backing panels, discrete nonasbestos fiber-cement interior substrate sheets or nonasbestos fiber-mat reinforced cementitious backer units in compliance with ASTM C 1178, C 1288 or C 1325 and installed in accordance with manufacturer recommendations shall be used as a base for wall tile in tub and shower areas and wall and ceiling panels in shower areas. Water-resistant gypsum backing board shall be used as a base for tile in water closet compartment walls when installed in accordance with GA-216 or ASTM C 840 and manufacturer recommendations. Regular gypsum wallboard is permitted under tile or wall panels in other wall and ceiling areas when installed in accordance with GA-216 or ASTM C 840. 2509.3 Limitations. Water-resistant gypsum backing board shall not be used in the following locations: 1. Over a vapor retarder in shower or bathtub compartments. 2. Where there will be direct exposure to water or in areas subject to continuous high humidity. 3. On ceilings where frame spacing exceeds 12 inches (305 mm) o.c. for 1 / 2 -inch thick (12.7 mm) water-resistant gypsum backing board and more than 16 inches (406 mm) o.c. for 5 / 8 -inch thick (15.9 mm) water-resistant gypsum backing board. SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO) 2510.1 General. Exterior and interior cement plaster and lathing shall be done with the appropriate materials listed in Table 2507.2 and Chapter 35. 2510.2 Weather protection. Materials shall be stored in such a manner as to protect such materials from the weather. 2510.3 Installation. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. 2510.4 Corrosion resistance. Metal lath and lath attachments shall be of corrosion-resistant material. 2510.5 Backing. Backing or a lath shall provide sufficient rigidity to permit plaster applications. 2510.5.1 Support of lath. Where lath on vertical surfaces extends between rafters or other similar projecting members, solid backing shall be installed to provide support for lath and attachments. 2510.5.2 Use of gypsum backing board. 2510.5.2.1 Use of gypsum board as a backing board. Gypsum lath or gypsum wallboard shall not be used as a backing for cement plaster. Exception: Gypsum lath or gypsum wallboard is permitted, with a water-resistive barrier, as a backing for self-furred metal lath or self-furred wire fabric lath and cement plaster where either of the following conditions occur: 1. On horizontal supports of ceilings or roof soffits. 2. On interior walls. 2510.5.2.2 Use of gypsum sheathing backing. Gypsum sheathing is permitted as a backing for metal or wire fabric lath and cement plaster on walls. A waterresistive barrier shall be provided in accordance with Section 2510.6. 2510.5.3 Backing not required. Wire backing is not required under expanded metal lath or paperbacked wire fabric lath. 2510.6 Water-resistive barriers. Water-resistive barriers shall be installed as required in Section 1404.2 and, where applied over wood-based sheathing, shall include a waterresistive vapor-permeable barrier with a performance at least equivalent to two layers of Grade D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance with Section 1405.4) intended to drain to the water-resistive barrier is directed between the layers. Exception: Where the water-resistive barrier that is applied over wood-based sheathing has a water resistance equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially nonwater-absorbing layer or drainage space. 2510.7 Preparation of masonry and concrete. Surfaces shall be clean, free from efflorescence, sufficiently damp and 384 2013 CALIFORNIA BUILDING CODE

> rough for proper bond. If the surface is insufficiently rough, approved bonding agents or a Portland cement dash bond coat mixed in proportions of not more than two parts volume of sand to one part volume of Portland cement or plastic cement shall be applied. The dash bond coat shall be left undisturbed and shall be moist cured not less than 24 hours. SECTION 2511 INTERIOR PLASTER 2511.1 General. Plastering gypsum plaster or cement plaster shall not be less than three coats where applied over metal lath or wire fabric lath and not less than two coats where applied over other bases permitted by this chapter. Exception: Gypsum veneer plaster and cement plaster specifically designed and approved for one-coat applications. 2511.1.1 Installation. Installation of lathing and plaster materials shall conform with Table 2511.1.1 and Section 2507. TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION STANDARD Cement plaster ASTM C 926 Gypsum plaster ASTM C 842 Gypsum veneer plaster ASTM C 843 Interior lathing and furring (gypsum plaster) ASTM C 841 Lathing and furring (cement plaster) ASTM C 1063 Steel framing ASTM C 754; C 1007 2511.2 Limitations. Plaster shall not be applied directly to fiber insulation board. Cement plaster shall not be applied directly to gypsum lath or gypsum plaster except as specified in Sections 2510.5.1 and 2510.5.2. 2511.3 Grounds. Where installed, grounds shall ensure the minimum thickness of plaster as set forth in ASTM C 842 and ASTM C 926. Plaster thickness shall be measured from the face of lath and other bases. 2511.4 Interior masonry or concrete. Condition of surfaces shall be as specified in Section 2510.7. Approved specially prepared gypsum plaster designed for application to concrete surfaces or approved acoustical plaster is permitted. The total thickness of base coat plaster applied to concrete ceilings shall be as set forth in ASTM C 842 or ASTM C 926. Should ceiling surfaces require more than the maximum thickness permitted in ASTM C 842 or ASTM C 926, metal lath or wire fabric lath shall be installed on such surfaces before plastering. 2511.5 Wet areas. Showers and public toilet walls shall conform to Sections 1210.2 and 1210.3. When wood frame walls and partitions are covered on the interior with cement plaster or tile of similar material and are subject to water splash, the framing shall be protected with an approved moisture barrier. SECTION 2512 EXTERIOR PLASTER 2512.1 General. Plastering with cement plaster shall be not less than three coats when applied over metal lath or wire fabric lath or gypsum board backing as specified in Section 2510.5 and shall be not less than two coats when applied over masonry or concrete. If the plaster surface is to be completely covered by veneer or other facing material, or is completely concealed by another wall, plaster application need only be two coats, provided the total thickness is as set forth in ASTM C 926. 2512.1.1 On-grade floor slab. On wood framed or steel stud construction with an on-grade concrete floor slab system, exterior plaster shall be applied in such a manner as to cover, but not to extend below, the lath and paper. The application of lath, paper and flashing or drip screeds shall comply with ASTM C 1063. 2512.1.2 Weep screeds. A minimum 0.019-inch (0.48 mm) (No. 26 galvanized sheet gage), corrosion-resistant weep screed with a minimum vertical attachment flange of 3 1 / 2 inches (89 mm) shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. The weep screed shall be placed a minimum of 4 inches (102 mm) above the earth or 2 inches (51 mm) above paved areas and be of a type that will allow trapped water to drain to the exterior of the building. The water-resistive barrier shall lap the attachment flange. The exterior lath shall cover and terminate on the attachment flange of the weep screed. 2512.2 Plasticity agents. Only approved plasticity agents and approved amounts thereof shall be added to Portland cement or blended cements. When plastic cement or masonry cement is used, no additional lime or plasticizers shall be added. Hydrated lime or the equivalent amount of lime putty used as a plasticizer is permitted to be added to cement plaster or cement and lime plaster in an amount not to exceed that set forth in ASTM C 926. 2512.3 Limitations. Gypsum plaster shall not be used on exterior surfaces. 2512.4 Cement plaster. Plaster coats shall be protected from freezing for a period of not less than 24 hours after set has occurred. Plaster shall be applied when the ambient temperature is higher than 40 F (4 C), unless provisions are made to keep cement plaster work above 40 F (4 C) during application and 48 hours thereafter. 2512.5 Second-coat application. The second coat shall be brought out to proper thickness, rodded and floated sufficiently rough to provide adequate bond for the finish coat. The second coat shall have no variation greater than 1 / 4 inch (6.4 mm) in any direction under a 5-foot (1524 mm) straight edge. 2512.6 Curing and interval. First and second coats of cement plaster shall be applied and moist cured as set forth in ASTM C 926 and Table 2512.6. 2013 CALIFORNIA BUILDING CODE 385

COAT TABLE 2512.6 CEMENT PLASTERS MINIMUM PERIOD MOIST CURING MINIMUM INTERVAL BETWEEN COATS First 48 hours a 48 hours b Second 48 hours 7 days c Finish Note c a. The first two coats shall be as required for the first coats of exterior plaster, except that the moist-curing time period between the first and second coats shall not be less than 24 hours. Moist curing shall not be required where job and weather conditions are favorable to the retention of moisture in the cement plaster for the required time period. b. Twenty-four-hour minimum interval between coats of interior cement plaster. For alternative method of application, see Section 2512.8. c. Finish coat plaster is permitted to be applied to interior cement plaster base coats after a 48-hour period. 2512.7 Application to solid backings. Where applied over gypsum backing as specified in Section 2510.5 or directly to unit masonry surfaces, the second coat is permitted to be applied as soon as the first coat has attained sufficient hardness. 2512.8 Alternate method of application. The second coat is permitted to be applied as soon as the first coat has attained sufficient rigidity to receive the second coat. 2512.8.1 Admixtures. When using this method of application, calcium aluminate cement up to 15 percent of the weight of the Portland cement is permitted to be added to the mix. 2512.8.2 Curing. Curing of the first coat is permitted to be omitted and the second coat shall be cured as set forth in ASTM C 926 and Table 2512.6. 2512.9 Finish coats. Cement plaster finish coats shall be applied over base coats that have been in place for the time periods set forth in ASTM C 926. The third or finish coat shall be applied with sufficient material and pressure to bond and to cover the brown coat and shall be of sufficient thickness to conceal the brown coat. graded white or natural sand by volume. The bedding coat for interior surfaces shall be composed of 100 pounds (45.4 kg) of neat gypsum plaster and a maximum of 200 pounds (90.8 kg) of graded white sand. A factory-prepared bedding coat for interior or exterior use is permitted. The bedding coat for exterior surfaces shall have a minimum compressive strength of 1,000 pounds per square inch (psi) (6895 kpa). 2513.4 Application. The bedding coat is permitted to be applied directly over the first (scratch) coat of plaster, provided the ultimate overall thickness is a minimum of 7 / 8 inch (22 mm), including lath. Over concrete or masonry surfaces, the overall thickness shall be a minimum of 1 / 2 inch (12.7 mm). 2513.5 Bases. Exposed aggregate plaster is permitted to be applied over concrete, masonry, cement plaster base coats or gypsum plaster base coats installed in accordance with Section 2511 or 2512. 2513.6 Preparation of masonry and concrete. Masonry and concrete surfaces shall be prepared in accordance with the provisions of Section 2510.7. 2513.7 Curing of base coats. Cement plaster base coats shall be cured in accordance with ASTM C 926. Cement plaster bedding coats shall retain sufficient moisture for hydration (hardening) for 24 hours minimum or, where necessary, shall be kept damp for 24 hours by light water spraying. SECTION 2513 EXPOSED AGGREGATE PLASTER 2513.1 General. Exposed natural or integrally colored aggregate is permitted to be partially embedded in a natural or colored bedding coat of cement plaster or gypsum plaster, subject to the provisions of this section. 2513.2 Aggregate. The aggregate shall be applied manually or mechanically and shall consist of marble chips, pebbles or similar durable, moderately hard (three or more on the Mohs hardness scale), nonreactive materials. 2513.3 Bedding coat proportions. The bedding coat for interior or exterior surfaces shall be composed of one part Portland cement and one part Type S lime; or one part blended cement and one part Type S lime; or masonry cement; or plastic cement, and a maximum of three parts of 386 2013 CALIFORNIA BUILDING CODE