Insulated Fire-Rated Access Door Model(s): BIT/BIW/BIP

Similar documents
5-1/2 inch Vinyl Handrail Model(s): BHRVE55C-P

SECTION ACCESS DOORS AND FRAMES

SECTION ACCESS DOORS AND FRAMES

where high efficiency is the standard

SECTION METAL DOORS & FRAMES

B. Provide fire-rated access doors where indicated or scheduled.

4-PIECE SHOWER WITH E-Z Pin INSTALLATION

SINGLE SWING DOOR PAIRED SWING DOOR

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

Access Doors. Babcock-Davis Always right there.

RECEIVING AND HANDLING

HOTEL SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

LO-DOCK LEVELER (LD) OWNER S MANUAL AND INSTALLATION GUIDE GLOBAL GROUP INC. PROOF

Application & General Notes: Installation Supplements: Safety Warning: Other Installation References: Receiving & Handling: Electrical Guidelines:

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

Access Doors Standard and Custom

Installation Guide. Linear Drain Shower bases

To Contact PS DOORS:

SERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual

for FD & DFD 150X MODELS

Installation, Operation and Maintenance Manual

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

4-PIECE SHOWER & TUB/SHOWER w/ E-Z Pin INSTALLATION

1. Include construction details, materials, individual components and profiles, and finishes.

INSTALLATION MANUAL PROVIDER PLUS

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

SECTION GYPSUM BOARD

INSTALLATION GUIDE MODELS DMV2402 / DMV3002 / DMV3602

Installation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors.

Pallet Gate Installation Instructions and Operators Manual

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Gun Safe 6720F / 6740F. Operation & Installation Guide. FIRE 30minutes /1100ºF RATED THEFT. Manual # M

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

RSIC-V RSIC-V INSTALLATION GUIDE RSIC-V SOUND ISOLATION CLIP

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

WHERE HIGH EFFICIENCY IS THE STANDARD

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

FIXED CEILING COLUMN. Installation Manual FIXED CEILING COLUMN

Construction Standards PAGE

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing

WHERE HIGH EFFICIENCY IS THE STANDARD

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Document Number FD & DFD 150X MODELS Hour Curtain Fire Dampers Vertical or Horizontal Mount

INSTALLATION GUIDE MODELS DMV2401 / DMV3001 / DMV3601 DMV4801 / DMV6001 / DMV60DS / DMV72DS

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

RSIC-V INSTALLATION GUIDE RSIC-V SOUND ISOLATION CLIP. PAC International, Inc. Tel: (866) Fax: (866) Web Site:

10331 Date Street Murrieta, CA SECTION HYBRID LAMINATE LOCKERS W/ PHENOLIC DOORS

ION Fresh & Clean Ventilation System Part # Basement Unit Part # Crawlspace Unit

Ion Fresh & Clean Ventilation System

RSIC-1 SOUND ISOLATION SYSTEMS RSIC-1 INSTALLATION GUIDE

Prime Shower Enclosure & Base Kit

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Allure Aluminum Fencing

PrimeWall Stud Interior Drywall Stud PrimeWall EQ Stud Interior Drywall Stud

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

INSTALLATION MANUAL RECTANGULAR COLUMN

Construction Standards PAGE

220 E. General Robinson St. Pittsburgh, PA fax

installation instructions Combination Fire & Smoke Damper

Installation, Operation and Maintenance Manual

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

B. Surface, partition and recessed mounted toilet and bath accessories indicated on the Drawings and Schedules.

Pedestrian Flood Door

Installation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier.

TORERO TUB DOOR INSTALLATION INSTRUCTIONS

Aqua Ultra Shower Door & Base Kit

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

ROOF MOUNT KIT OWNERS MANUAL

SHOWER & TUB/SHOWER INSTALLATION

SECTION SOLID PLASTIC TOILET PARTITIONS. A. Section Includes: Toilet partitions and urinal screens, complete with hardware.

MTI BATHS BOUTIQUE COLLECTION ENGINEERED SOLID STONE SHOWER BASES OWNER S MANUAL INSTALLATION GUIDE EFFECTIVE JANUARY 1, 2013

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY

Access Doors. Babcock-Davis Always right there.

1.0. Post Install Kit. For Use With All Vinyl Railing BOM V1 1/13. Owner's Manual. Assembly and Installation Instructions.

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

Access Doors. Complementary Building Products. Right to site.

Prime Shower Enclosure & Base

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

Product Description. Standard Sizes and Hardware Locations

Impression Graphic panels

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

INSTALLATION INSTRUCTIONS FOR BALCO, INC. TRENCH AND ACCESS COVER TSA/ACA-X-250 W/O LINER FOR CAST-IN-PLACE INSTALLATION

Bottom Hinged Flood Barrier Operation & Maintenance Manual

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips)

SECTION ACCESS PANELS

QUADLUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

DESCRIPTION SAFETY: WARNINGS ORDERING INFORMATION T01-B INSTALLATION INSTRUCTIONS DROP-IN AND FREESTANDING BATH K-11343T / K-11344T

WEC Manufacturing Phone: (901) Website: Itswec.com

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Transcription:

Insulated Fire-Rated Access Door INSTALLATION, OPERATION & MAINTENANCE MANUAL

Table of Contents Insulated Fire-Rated Access Door Table of Contents General Description...3 Installation...4-7 Operation...8 Maintenance...8 Parts List...9 Standard Warranty...10 Factory Assistance...11 Copyright 2017 by Babcock-Davis. All rights reserved. This document contains proprietary information. No part of this document may be reproduced without the prior written consent of Babcock-Davis. Note The information in this document is subject to change without notice. General Safety Precautions Improper selection, installation, or use can cause personal injury or property damage. It is solely the responsibility of the user, through its own analysis to select products suitable for their specific application requirements, ensure they are properly maintained, and limit their use to its intended purpose. Follow proper local, state and federal regulations for proper installation and operation requirements. 2

Insulated Fire-Rated Access Door general description general description Access Doors are designed and built for years of convenient and easy access to mechanical areas in commercial buildings. The following is a general instruction for installing, operating and maintaining Access Doors. These are recommended general guidelines only. Locally accepted practices and procedures should be followed to ensure the ultimate durability of access doors installed into the various different types of construction. 3

stud wall installation Insulated Fire-Rated Access Door stud wall installation Proper installation is critical to maintaining and withstanding the fire-ratings shown on the product label. When correctly installed, the door will close and latch when released from an open position of approximately 60. Tools Needed Supplies Needed 5/32 Drill Bit and Drill #12 Drywall Screws Screwdriver Preparation 1. Install a framed opening at specified location of access door. 2. Opening dimensions should be 1/4 inch larger than catalog size of door, after wrapping studs with 5/8 inch type X (fire-resistant) gypsum board if necessary. Example: 12 inch by 12 inch door, opening should be 12-1/4 inches by 12-1/4 inches. A notched out area is required for the lock bolt cover. Installation (fig. 1) 1. Place door in opening and mark location of attachments on studding using holes in latch and hinge side of door frame as guides. 2. Remove door and drill 5/32 inch holes through studs at points marked for attachment hole. 3. Place door into position and fasten to wall as follows: Wood Substrates Steel Substrates #12 X 1-1/4" drywall screws; minimum of 2 per side. #12 x 1-1/8" drywall screws; minimum of 2 per side. For panels utilizing a drywall bead flange (BIW), screws should be fastened at 18 inches on center maximum through the flange face in addition to the pre-existing holes located on the inside of the frame. 4. Check door for freedom of movement. If it binds, shim to remove any racking of frame at attachment points. 5. Install springs per reference table, pg. 9. Self-closure of door is required for UL or Warnock-Hersey fire rating. Neglecting to install springs will void the fire-rating. 4

Insulated Fire-Rated Access Door masonry wall installation masonry wall installation Proper installation is critical to maintaining and withstanding the fire-ratings shown on the product label. When correctly installed, the door will close and latch when released from an open position of approximately 60. Tools Needed Drill Bit and Drill Supplies Needed #10-32 x 1" flat-head steel machine screws Preparation Opening dimensions should be 1/4 inch larger than catalog size of door. Example: 12 inch by 12 inch door, opening should be 12-1/4 inches by 12-1/4 inches. A notched out area is required for the lock bolt cover. Installation (fig. 1) 1. For new construction, unfold masonry anchors prior to fill. 2. Place door in opening and mark location of attachments on wall using holes in latch and hinge sides of door as guides. 3. Remove door and install expansion shields in wall at points marked. 4. Place door in position and attach with #10-32 x 1inch flat-head steel machine screws. 5. Check door panel for freedom of movement. If it binds, shim to remove any racking of frame at attachments. 6. Install springs per reference table, pg. 9. Self-closure of door is required for UL or Warnock-Hersey fire rating. Neglecting to install springs will void the fire-rating. fig. 1 5

ceiling installation Insulated Fire-Rated Access Door ceiling installation Proper installation is critical to maintaining and withstanding the fire-ratings shown on the product label. When correctly installed, the door will close and latch when released from an open position of approximately 60. Tools Needed Supplies Needed 5/32 Drill Bit and Drill #12 Drywall Screws Screwdriver Preparation 1. Install a framed opening at specified location of access door. 2. Opening dimensions should be 1/4 inch larger than catalog size of door, after wrapping studs with 5/8 inch type X (fire-resistant) gypsum board if necessary. Example: 12 inch by 12 inch door, opening should be 12-1/4 inches by 12-1/4 inches. A notched out area is required for the lock bolt cover. 3. Frame can be supported with 12 gauge wire ties to ceiling structure at all four corners or plumbers tape attached from framing screws to studs of floor above for ease of installation, fig. 3. Installation 1. Place door in opening and mark location of attachments on studding using holes in latch and hinge side of door frame as guides. 2. Remove door and drill 5/32 inch holes through studs at points marked for attachment hole. 3. Place door into position and fasten to wall as follows: Wood Substrates Steel Substrates #12 X 1-1/4" drywall screws; minimum of 2 per side. #12 x 1-1/8" drywall screws; minimum of 2 per side. 4. Check door for freedom of movement. If it binds, shim to remove any racking of frame at attachment points. 5. Install springs per reference table, fig. 2. Self-closure of door is required for UL or Warnock-Hersey fire rating. Neglecting to install springs will void the fire-rating. 6

Insulated Fire-Rated Access Door ceiling installation ceiling installation Quantity Spring Location of Springs B A C 1-1 - 2-2 - 3 2-1 4 2-2 5 2 1 2 6 2 2 2 fig. 2 12 GA. WIRE TIE fig. 3 7

operation + maintenance Insulated Fire-Rated Access Door operation + maintenance Access doors are designed and built for years of dependable wall or ceiling access. Our access doors come standard with a paintable, powder coat finish. maintenance Access doors should be manually operated once a year to check performance. Lubricate moving parts such as hinges and latches with a silicone spray lube as required to maintain a smooth opening and closing of the door. Do not over grease. Do not use regular lubricating oil as it can attract dust and grit. Non-moving parts can be cleaned with a mild soap or dish washing detergent and water solution. 8

Insulated Fire-Rated Access Door parts list parts list Part Number Description AD-KIT-SPRING-S SHORT DOOR CLOSER SPRING, 3.64" AD-KIT-SPRING-L LONG DOOR CLOSER SPRING, 7.13" Door Size 08 X 08 Spring Part Number Spring Quantity Bracket Quantity 1 1 10 X 10 1 1 AD-KIT-SPRING-S 12 X 12 1 1 (Under 16" wide) 12 X 24 2 1 14 X 14 1 1 16 X 16 2 1 18 X 18 2 1 18 X 24 3 2 20 X 30 4 2 22 X 22 3 2 22 X 30 4 2 22 X 36 3 2 24 x 24 AD-KIT-SPRING-L 4 2 24 x 30 (16" wide & larger) 5 3 24 x 36 6 3 24 X 48* 2 1 30 X 30* 1 1 32 X 32* 2 1 36 X 36* 2 1 36 X 48* 2 1 48 X 48* 3 2 *Wall applications only. 9

standard warranty Insulated Fire-Rated Access Door standard warranty Babcock-Davis warrants all Access Doors to be free from manufacturing defects in materials, factory finishes and workmanship for a period of one (1) year from the date of shipment. Should a product fail to function in normal use within this period, Babcock-Davis shall furnish a replacement or new part at Babcock-Davis discretion. Failure to use product in methods consistent with Babcock-Davis product manuals shall relieve Babcock-Davis of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature. For warranty support and registration please visit www.babcockdavis.com/support 10

Insulated Fire-Rated Access Door factory assistance factory assistance Babcock-Davis engineers and manufactures access doors for worldwide customers. Our products enable safe access to plumbing and mechanical equipment. Recognized as an industry leader, Babcock-Davis has been relied upon by building and construction professions for over 100 years and we pride ourselves in offering exceptional technical support. Please do not return any product before discussing your application problem with a Babcock-Davis representative and obtaining a Return Authorization. Your Babcock-Davis representative is eager to help you. Please feel free to call your representative or contact Babcock-Davis to discuss your application. Babcock-Davis 9300 73rd Avenue North Brooklyn Park, MN 55428 Phone: 888.412.3726 Fax: 888.312.3726 Email: info@babcockdavis.com 11

Visit www.babcockdavis.com for the latest version of this document and more information. Great Products. Better Partners. 9300 73RD AVENUE NORTH BROOKLYN PARK, MN 55428 (888) 412-3726 (888) 312-3726 FAX WWW.BABCOCKDAVIS.COM