Product Test Summaries

Similar documents
Product Test Summaries Nichiha Fiber Cement Products Sierra Premium Boards

Product Test Summaries

Test Summaries: AWP 1818 & 3030

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

Product Test Summaries

Product Test Summaries

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

RENDERED TO. CastleRock Building Products Incorporated P.O. Box 1258 Meridian, ID USA 83680

Gold Bond BRAND Gypsum Sheathing

Specification Document

FIRE RESISTANCE TESTS OF BRICK VENEER / WOOD FRAME WALLS J. GREGG BORCHELT

Delivering the Power of POSSIBILITIES. Residential Full Line Catalog

Delivering the Power of POSSIBILITIES. Residential Full Line Catalog

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

Architectural Specifications

Residential Full Line Catalog

NichiProducts TM & Full Line Catalog

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS)

GA GYPSUM BOARD TYPICAL MECHANICAL AND PHYSICAL PROPERTIES

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

ASTM E Fire Tests of Building Construction and Materials* Protective Structures, Ltd. Bullet-Resistant FRP Panel

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

2012 & 2015 International Building Code. Section Section Section 713.4

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

2012 & 2015 International Building Code. Section Section Section Section Section Section 713.4

ICC-ES Evaluation Report Reissued February 1, 2012 This report is subject to renewal February 1, 2013.

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

About TAKTL. What is TAKTL?

JOHNS MANVILLE CONTINUOUS INSULATION WALL SYSTEM MASTER SPECIFICATION June 2014 CSI FORMAT SECTION FOIL-FACED RIGID INSULATION

SPECIFICATION GUIDELINE

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: December 18, 2012 REVISED DATE:

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

Construction Standards PAGE

Deer Ridge Consulting, Inc.

Gypsum Board Systems Manual

Prepared by: DPA Issue No.: XIX Checked by: EAG

SECTION INSULATING CONCRETE FORMING (ICF)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

Advantage ICF System Product Information Bulletin

Showcase Your Space. Not Your Access Panel. Product Features. Shop online at or call

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Fire Testing Laboratory TEST REPORT FOR THERMORY USA, LLC Wilmette Avenue, Suite 208 Wilmette, IL 60091

PinkWood Ltd. Revised September 29, 2017

(800) (562) A Subsidiary of the International Code Council

OBJECTIVE TEST ASSEMBLY

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: April 30, 2013 REVISED DATE:

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: March 13, 2013 REVISED DATE:

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

SECTION Fiber Reinforced Stucco 1

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Code Compliance Research Report CCRR-0231

REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: September 14, 2012 REVISED DATE: N/A

Architectural Specifications

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: October 30, 2014 REVISED DATE:

EVALUATION CENTER INTERTEK TESTING SERVICES NA LTD BRIGANTINE DRIVE COQUITLAM, BC V3K 7C1 RENDERED TO

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

WFCi Report # Conducted For: Supress Products LLC. 5/8 Supress Sound-Engineered Drywall SED58410C; U305 Design

Issue Date: April 2003 Release: I. Product Specifications

The provisions of this document apply to Residential projects, as well as Commercial and Multifamily projects not exceeding a height of 75 feet.

FIRE ENDURANCE RATINGS CLAY BRICK MASONRY

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

TEST REPORT. Report No.: H Rendered to: GEORGIA-PACIFIC WOOD PRODUCTS, LLC Atlanta, Georgia

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

Thermo-Ply Red & Thermo-Ply Red AMG Structural Sheathing Canada Limit States Design. TER No

CertainTeed. Tile Backer

A. Source Limitations: Obtain each type of building insulation through one source.

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

RAY-CORE Structural Insulated Roof and Wall Panels

SECTION GLASS FIBER REINFORCED GYPSUM FABRICATIONS

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: March 13, 2017 REVISED DATE:

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

1/2 in. (12.7 mm) and 5/8 in. (15.9 mm) glass mesh. It has an exceptionally hard, durable surface that can withstand prolonged exposure to moisture.

REPORT NUMBER: SAT-002A ORIGINAL ISSUE DATE: August 16, 2017 REVISED DATE:

FIRE RESISTANCE RATING OF TEK 7-1A CONCRETE MASONRY ASSEMBLIES

SPECIFICATION GUIDELINE

Drywall and Plastering

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

Section Roof/Ceiling Thermal Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

REPORT NUMBER: SAT-001A Rev 1 ORIGINAL ISSUE DATE: November 16, 2010 REVISED DATE: June 20, 2011

ROCKWOOL Board Insulation Section Master Guide Specification (CURTAINROCK 80) Page 1 January 2018

Gold Bond BRAND Kal-Kore Plaster Base

RLGA. Gypsum Board Construction 2012 International Building Code. By Ronald L. Geren, AIA, CSI, CCS, CCCA, SCIP

Exterior Wall Solutions Building Shell

1. Opinion. 2. Description. MasterFormat: Evaluation issued: Re-evaluated: Evaluation revised:

USG Co. Plant # th Street Mediapolis, IA Atlantic Wallboard Ltd. # Jervis Lane St. John, NB E2J 0A9

WALL APPLICATIONS IN BUILDINGS EXCEPTIONAL R-VALUE. OUTSTANDING RESISTANCE TO MOISTURE. LONG TERM DURABILITY.

Magnum Board Section Digicon Information Inc. Page 1

REPORT NUMBER: SAT-004A ORIGINAL ISSUE DATE: April 13, 2017 REVISED DATE:

Transcription:

NichiProducts TM NichiBoard TM, NichiFrontier TM, NichiPanel TM, NichiShake TM, NichiSoffit TM, NichiStaggered TM, NichiStraight TM Product Test Summaries ASTM C 1185 Physical Properties Tests ASTM E 84/CAN/ULC S102-07 Surface Burning Characteristics ASTM E 119/CAN/ULC S101-07 Fire Resistance of Wall Assembly - Metal Construction ASTM E 119/CAN/ULC S101-07 Fire Resistance of Wall Assembly - Wood Construction Letter Re: Report No. 3015885COQ-002 - ASTM E136 Non-Combustibility Test Results Independent Code Evaluation and Wind Load Testing: Refer to PEI-PER 14086 for NichiProducts wind load (ASTM E 330) data. TS-NP 11.15

ASTM ASTM C 1185 C Physical 1185 Physical Properties Properties Tests Tests Date Of Test: May 20, 2008 Test Agency: Test Method: Intertek Testing Services NA LTD. 1500 Brigantine Drive, Coquitlam, BC V3K 7C1 Canada ASTM C 1185 Durability tests including linear variations with change in moisture content, water tightness, wet flexural strength, freeze/thaw, warm water, and heat/rain. Test Specimen: NichiBoard, NichiPanel, NichiShake, and NichiSoffit - i.e. NichiProducts Specimen : 5/16 and 1/4 Specifications: : Various. Length: Various. Test Procedure: Test Results: The test was performed in accordance to ASTM requirements. The test results show the Nichiha NichiProducts Fiber Cement Boards successfully comply with the requirements specified in the ICC-ES Acceptance Criteria for Fiber Cement for use. Physical Property Test Results for NichiBoard TM Property Test Result Requirement Dimensional Tolerances, in Length ± 0.38 ± 0.38 Density, lb/ft 3 77.6 As reported Heat Rain Resistance Physical Property Test Results for NichiPanel TM Property Test Result Requirement Dimensional Tolerances, in Water Tightness Length 0.06 No formation of water drops No formation of water drops Heat Rain Resistance NichiProducts Product Test Summaries 2 NichiProducts Fiber Cement Boards and Panels - Product Test Summaries 2

ASTM ASTM C 1185 C 1185 Physical Physical Properties Properties Tests (cont.) Tests (cont.) Physical Property Test Results for NichiShake TM Property Test Result Requirement Dimensional Tolerances, in 12"wide Length 8-1/4" wide Length 6-1/4" wide Length Flexural Strength, psi Frost Resistance 0.06 0.04 0.07 0.04 Dry 2154 > 1450 1 Wet 1743 > 1015 1 Strength Retention % 96 > 80 Observation Warm Water Resistance No deleterious effects No deleterious effects Strength Retention % 103 As Reported Observation No deleterious effects No deleterious effects Heat Rain Resistance No cracks or structural Note 1 - Grade II requirements taken from Table 1 - "Flexural Strength Requirements" of ASTM C1186-07 NichiProducts Product Test Summaries 3 NichiProducts Fiber Cement Boards and Panels - Product Test Summaries 3

ASTM C 1185 C 1185 Physical Physical Properties Properties Tests (cont.) Tests (cont.) Physical Property Test Results for NichiSoffit TM Property Test Result Requirement Dimensional Tolerances, in Length 0.04 0.02 ± 0.38 ± 0.38 Moisture Movement, % 0.08 As Reported Water Absorption, % 38.1 As Reported Moisture Content, % 10.5 As Reported NichiProducts Product Test Summaries 4 NichiProducts Fiber Cement Boards and Panels - Product Test Summaries 4

ASTM ASTM E 84/CAN/ULC E CAN/ULC S102-07 S102-07 Surface Surface Burning Burning Characteristics Date of Test: June 25, 2008 Test Agency: Test Method: Test Specimen: Intertek Testing Services NA LTD. 1500 Brigantine Drive, Coquitlam, B.C. V3K 7C1 Canada ASTM E 84 Standard test method for surface burning characteristics of building materials, sometimes referred to as the Steiner Tunnel test. 5/16 thick NichiProducts Specimen : 5/16 Specifications: : Various. Length: Various. Test Procedure: Test Results: For each trial run, three 8ft. panels were placed on the upper ledge of the flame spread tunnel and butted to- gether to form the required 24ft. sample length. A layer of 6mm reinforced cement board was placed over the top of the samples, the tunnel lid was lowered into place, and the samples were then tested in accordance with ASTM E84-08. The test result is shown in the table below. NichiProducts meets Class A requirements. Test Sample Maximum Flame Spread (ft.) Smoke Developed NichiProducts 0 1 Note: Class A requirements: Flame Spread < 25 Smoke Developed < 450 NichiProducts Product Test Summaries 5 NichiProducts Fiber Cement Boards and Panels - Product Test Summaries 5

ASTM E E 119/CAN/ULC CAN/ULC S101-07 S101-07 Fire Resistance Fire Resistance of Wall of Assembly Wall Assembly - Metal Metal Construction Date of Test: September, 2008 Test Agency: Test Method: Test Specimen: Intertek Testing Services 1500 Brigantine Drive, Coquitlam, B.C. V3K 7C1 ASTM E/CAN/ULC S101-07 Standard practicing for fire tests of building construction and materials. NichiBoard, NichiPanel Specimen : 5/16 Specifications: : 12 trimmed as needed for tests. Length: 12 trimmed as needed for tests. Test Panel Structure: 20-gauge steel studs on 3 5/8 deep track, placed at 16 in. on center. R-13 fiberglass un-faced insulation (4-in thickness) was installed within each stud cavity. Both sides of wall assembly were faced with 5/8 Type-X gypum wallboards oriented horizontally with joints staggered. Drywall tape was applied to all joints. 15-lb felt paper was installed over gypsum board on the exposed surface with ¼ staples. Nichiboards were installed, per installation instructions, using 1-5/8 self-tapping screws at each stud. Test Procedure: Test Result: The test panel was secured to the test fixture in accordance with the requirements of ASTM. The test exposes a wall assembly to a standard fire exposure controlled to achieve specified temperatures throughout a specified time period. The fire exposure may be followed by a standard hose steam test, which subjects the specimen to impact, erosion, and cooling effects of the water stream. The wall was evaluated with the exterior (Nichiha face) exposure. The walls successfully endured a 60 minute fire exposure without developing excessive surface temperatures or allowing flaming on the unexposed side of the assembly. 1 Hour Steel-Stud Assembly Time (min.) Exposed Side Unexposed Side 5:00 No change 20:00 Some flaming observed 45:00 Gypsum wallboard intact 61:00 No change, test discontinued No flaming, no burn-through, no open cracks have occurred. NichiProducts Product Test Summaries 6 NichiProducts Fiber Cement Boards and Panels - Product Test Summaries 6

ASTM E 119 CAN/ULC S101-07 Fire Resistance of Wall Assembly Wood Construction Date of Test: September, 2008 Test Agency: Test Method: Intertek Testing Services 1500 Brigantine Drive, Coquitlam, B.C. V3K 7C1 ASTM E/CAN/ULC S101-07 Standard practicing for fire tests of building construction and materials. Test Specimen: NichiBoard, NichiPanel Specimen : 5/16 Specifications: : 12 trimmed as needed for tests. Length: 12 trimmed as needed for tests. Test Panel Structure: 2 x 4 Douglas Fir studs placed at 16 on center. R-13 fiberglass un-faced insulation was installed within each stud cavity. Both sides of the wall were faced with 5/8 Type-X gypsum wallboard with staggered joints. Drywall tape was applied to all joints. 15-lb felt paper was installed horizontally, with 6 inch overlap, over the gypsum wallboards on the fire side of the wall assembly using ¼ staples. Nichi boards were installed, per installation instructions, using 8D common nails over each stud. Test Procedure: The test panel was secured to the test fixture in accordance with the requirements of ASTM. The test exposes a wall assembly to a standard fire exposure controlled to achieve specified temperatures throughout a specified time period. The fire exposure may be followed by a standard hose steam test, which subjects the specimen to impact, erosion, and cooling effects of the water stream. Test Result: The wall was evaluated with the exterior (Nichiha face) exposure. The walls successfully endured a 60 minute fire exposure without developing excessive surface temperatures or allowing flaming on the unexposed side of the assembly. The data is shown below. 1 Hour Wood-Stud Wall Assembly Time (min.) Exposed Side Unexposed Side 0:00 2700 psi load applied (17,000 lbs.) 10:00 Siding is starting to crack 15:00 Tar paper has ignited 18:00 Siding has fallen off 25:00 Tar paper no longer burning 51:00 No change, holding 2700 psi load 60:00 No change, test discontinued No flaming, no burn-through, no open cracks have occurred, 2700 psi load held. NichiProducts Product Test Summaries 7 NichiProducts Fiber Cement Boards and Panels - Product Test Summaries 7

ASTM E 136 Non-Combustibility NichiProducts Product Test Summaries 8

ASTM E 136 Non-Combustibility NichiProducts Product Test Summaries 9 1-866-424-4421 nichiha.com 6465 East Johns Crossing, Suite 250 Johns Creek, GA 30097