LSA 42.3 Low Voltage Alternators - 4 pole

Similar documents
LSA 51.2 Low Voltage Alternators - 4 pole

Low Voltage alternators - 4 pole LSA 42.3

LSA 47.2 Low Voltage Alternators - 4 pole

Low Voltage Alternators - 4 pole LSA 46.2

Low Voltage Alternators - 4 pole LSA 46.3

LSA 53.2 Low Voltage Alternator - 4 pole

3867 en / f. Alternators. LSA Pole Electrical and mechanical data

3867 en / a

3820 en / c

Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2

3363 en / e

LSA Rating Table Low Voltage Alternators - 4 pole

ALTERNATOR. LSA 36 - single-phase to 11.5 kva

3456 en / c. 1 to 20 MW Land and offshore applications

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

Environmental Product Declaration FLSES. 3-phase induction motors with cast iron frame

EC medium pressure axial fans.

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw)

Environmental Product Declaration PLSES. 3-phase induction ODP motors

Product Environnemental Profile LSES. 3-phase induction motors with aluminium frame

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information

EC medium pressure axial fans. The efficient system solution.

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION

Interconnection Application

Dated: April 16, 2002

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

Generation Application Part B: Technical Form

Zero cross function. DIN track mounting *2. Screw mounting

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers.

Unit Coolers SKB. 4 kw 30,5 kw.

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8

Connection of generation plant to distribution networks. Guidance on completing the application form

Power Quality Improvement in Distribution System Using Distribution Static Compensator

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

Applications. Capacitance Tolerance The last three digits represent significant figures. The first digit specifies the total number of digits.

Equipment Specifications Low Voltage. Active Harmonic Filter


Applications R46 K I P0 M

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on

SPECIFICATION FOR APPROVAL

MODEL 16ASX T/S - SPECIFICATION

nicrom e l e c t r o n i c

- Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination

15 15A 20 20A 30 30A 40 40A 60 60A. Load voltage(rated) VAC VAC VDC 24VAC VAC

MAY-16 REV B2

Oil & Gas Energy Solutions. Power Generation Expertise for the Oil & Gas Industry

Cannon Trident Connector System

RadiFit EC centrifugal fans. Compact, efficient, easily upgraded.

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

Applications PME295 R B 3470 M R30 P 295 B E 471 M 440 A. First two digits represent significant figures. Third digit specifies number of zeros.

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

Air Cooler Industry AC-MS Modular Systems

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics

DRUM MOTOR 138LS 138.5Ø 0.10kW kW, with steel helical gearbox

Axial Fans - Basic principles. Expertise, performance, innovation

Low and Medium Voltage Motor Repair

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

Qualification Test Report VAL-U-LOK* Connectors

Product Specification JUL 14 Rev. A1

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

High Current Thermal Fuse

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

Bulkhead Feed-throughs

DRUM MOTOR 216LS 216.0Ø 0.11kW kW, with steel helical gearbox

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

Simple operation and a built-in bypass function make the CSX series a pleasure to use with many benefits in a tidy package.

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P W

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Applications R46 K I P0 M

ABSORPTION HYBRID FILTER FAR-Q TYPE

Metal Composite Type Power Choke Coils

Introduction of an innovative base isolation system for seismic protection of HV components based on a combination of wire ropes and viscous dampers

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

1. MECHANICAL: 2.ELECTRICAL: Dimension of fan shall be shown in the outline styling drawing attached Dimension Motor Four-pole motor.

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw

Analysis of kva Savings with PowerPlus under Certain Conditions. Robert N Guenther, Jr. VP- Product Development and Engineering IEEE Fellow

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw)

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

Transcription:

LSA 42.3 Low Voltage Alternators - 4 pole 2 to 60 kva - 0 Hz / 31. to 7 kva - 60 Hz Electrical and mechanical data

Specially adapted to applications The LSA 42.3 alternator is designed to be suitable for typical generator applications, such as: backup, marine applications, rental, telecommunications, etc. Compliant with international standards The LSA 42.3 alternator conforms to the main international standards and regulations: - IEC 60034, NEMA MG 1.32-33, ISO 28-3, CSA C22.2 n 0-14, UL 1446 (UL 04 on request), marine regulations, etc. It can be integrated into a CE marked generator. The LSA 42.3 is designed, manufactured and marketed in an ISO 01 and ISO 14001 environment. Top of the range electrical performance Class H insulation. Standard 12 wire re-connectable winding, 2/3 pitch, type no. 6 Voltage range: - 0 Hz: 2 V - 240 V and 3 V - 41 V (440 V) - 60 Hz: 8 V - 240 V and 3 V - 4 V High efficiency and motor starting capacity Other voltages are possible with optional adapted windings: - 0 Hz: 440 V (no. 7), 00 V (no. 9), 6 V (n ) - 60 Hz: 3 V and 416 V (no. 8), 600 V (no. 9) R 791 interference suppression conforming to standard EN 600-6-3, EN 600-6-2, EN 011 group 1 class B standard for European zone (CE marking) Reinforced mechanical structure using finite element modelling Compact rigid assembly to better withstand generator vibrations Steel frame Aluminium flanges and shields Two-bearing and single-bearing versions designed to be suitable for commercially-available heat engines Half-key balancing two bearing Permanently greased bearings ( 000h) Direction of rotation : clockwise and anti-clockwise (without derating) Excitation and regulation system suited to the application Excitation system Regulation options Voltage regulator PMG Current transformer for paralleling Mains paralleling 3-phase sensing 3-phase sensing for mains paralleling unbalanced Remote voltage potentiometer R2 Std - - - - - - - R438 - Std Std C.T. R726* R731* R734* R40* Option Option Option C.T. R726* R731* R734* DC* Option Option Option C.T. included included contacter factory * Steel terminal box mounting only : Possible mounting Compact and design terminal box Easy access to the AVR (lid) and to the connections 8 way terminal block for reconnecting the voltage Predrilled holes for cable gland Steel terminal box in option Protection system suited to the environment The LSA 42.3 is IP 23 Standard winding protection for clean environments with relative humidity, including indoor marine environments Options: - Filters on air inlet : derating % - Filters on air inlet and air outlet (IP 44) : derating % - Winding protection for harsh environments and relative humidity greater than - Space heaters - Thermal protection for stator windings - Height fixing : H = 22 mm (option) with the order 2 Electric Power Generation

General characteristics Insulation class H Excitation system or PMG Winding pitch 2/3 (wdg 6) AVR type R 2 R 438 Number of wires 12 Voltage regulation (*) ± 0. % ± 0. % Protection IP 23 Short-circuit current - 0% (3 IN): s Altitude 00 m Total Harmonic Distortion THD (**) in no-load... : < 2% Overspeed 220 min -1 Total Harmonic Distortion THD (**) on linear load : < 4% Air flow 0.m 3 /s, 0 Hz - 0.13m 3 /s, 60 Hz Waveform: NEMA = TIF (**) < 0 (*) Steady state. (**) Total harmonic distortion between phases, no-load or on-load (non-distorting). Ratings 0 Hz - 100 R.P.M. kva / kw - P.F. = 0.8 Duty/T C Continuous duty/40 C Continuous duty/40 C Stand-by/40 C Stand-by/27 C Class/T K H/12 K F/ K H/10 K H/163 K Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. Y 3V 400V 41V 440V 3V 400V 41V 440V 3V 400V 41V 440V 3V 400V 41V 440V 2V 2V 240V 2V 2V 2V 240V 2V 2V 2V 240V 2V 2V 2V 240V 2V YY 2V 2V 2V 2V 42.3 VS1 kva 2 24. 1 22.8 22.3 13.7 26. 26 1.9 27. 27 16. kw 19.6 12 18.2 17.9.9 21.2.8 12.7 22 21.6 13.2 42.3 VS2 kva 27 26 16.2 24.6 23.6 14.7 28.9 27.6 17.3 28 18 kw 21.6.8 13 19.7 18.9 11.8 23.1 22.1 13.9 24 22.9 14.4 42.3 VS3 kva 32 19.2 29.1 27.3 17. 34 31.8.4 3.2 33.0 21.1 kw 2.6 24 1.4 23.3 21.8 14 27.1 2.4 16.3 28.2 26.4 16.9 42.3 S4 kva 3.6 22 32 27.9 37.1 32. 23.3 38. 33.7 24.2 kw 28 24. 17.6 2. 22.3 16 29.7 26 18.7.8 27.0 19.4 42.3 S kva 40 3 2 36.4 31.9 22.8 42.4 37.1 26. 4 38. 28.1 kw 32 28 29.1 2. 18.2 33.9 29.7 21.2 36.8 22. 42.3 kva 4 39 27 41 3. 24.6 48.2 41.3 28.9 0 42.9 kw 36 31.2 21.6 32.8 28.4 19.7 38. 33.1 23.1 40 34.3 24 42.3 kva 0 43 4. 39.1 27.3 3 4.6 31.8 47.3 33 kw 40 34.4 24 36.4 31.3 21.8 42.4 36. 2.4 44 37.8 26.4 42.3 kva 60 1.6 36 4.6 47.0 32.8 63.6 4.7 38.2 66 6.8 40 kw 48 41.3 28.8 43.7 37.6 26.2 0.9 43.8. 2.8 4.4 32 Ratings 60 Hz - 10 R.P.M. kva / kw - P.F. = 0.8 Duty/T C Continuous duty/40 C Continuous duty/40 C Stand-by/40 C Stand-by/27 C Class/T K H/12 K F/ K H/10 K H/163 K Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. Y 3V 416V 440V 4V 3V 416V 440V 4V 3V 416V 440V 4V 3V 416V 440V 4V 2V 240V 240V 2V 240V 240V 2V 240V 240V 2V 240V 240V YY 8V 2V 240V 8V 2V 240V 8V 2V 240V 8V 2V 240V 42.3 VS1 kva 29.1 31.3 31. 31. 18.9 26. 28.4 28.7 28.7 17,2.8 33.1 33.4 33.4 19,8 32 34.4 34.7 34.7,8 kw 23.3 2 2.2 2.2 1.1 21.2 22.8 22.9 22.9 13,7 24.7 26. 26.7 26.7 1,9 2.6 27. 27.7 27.7 16,6 42.3 VS2 kva 29.9 31.9 33.8 33.8 19.2 26.9 29.7.7 17, 31.4 33.8 3.8 3.8,2 32. 3.1 37. 37. 21,1 kw 23.7 2. 27 27 1.4 21. 23.2 24.6 24.6 14,0 2.1 27.1 28.6 28.6 16,2 26 28.1 16,9 42.3 VS3 kva 34. 38 40 40 22.8 31.4 34.6 36.4 36.4,7 36.6 40.3 42.4 42.4 23,9 38 41.8 44 44 2,1 kw 27.6.4 32 32 18.2 2.1 27.7 29.1 29.1 16,6 29.3 32.2 33.9 33.9 19,1.4 33.4 3.2 3.2,0 42.3 S4 kva 37. 40.3 42.9 43.8 24.2 33.4 36.6 39.0 39.8 22,0 39 42.7 4.4 46.4 2,4 40.4 44.3 47.2 48.1 26,6 kw 32.2 34.3 3 19.3 26.8 29.3 31.2 31.9 17,6 31.2 34.1 36.4 37.1,3 32.3 3.4 37.7 38. 21,2 42.3 S kva 42 46 49 0 27.6 38.2 41.9 44.6 4. 2,1 44. 0 1.9 3 29,0 46.2 0.6 3.9,4 kw 33.6 36.8 39.2 40 22.1.6 33. 3.7 36.4,1 3.6 40 41.6 42.4 23,2 37 40. 43.1 44 24,3 42.3 kva 46 0 3. 6. 41.9 4. 48.7 1.4 27,3 48.8 3 6.7 9.9 31, 0.6 8.9 62. 33,0 kw 36.8 40 42.8 4.2 24 33. 36.4 38.9 41.1 21,8 39 42.4 4.4 47.9 2,2 40. 44 47.1 0 26,4 42.3 kva 1. 6. 9. 62. 33.9 46.9 1.4 4.1 7,8 4.6 60 63.1 66.3 3,6 6.7 62. 6. 68.8 37,3 kw 41.2 4.2 47.6 0 27.1 37. 41.1 43.3 4. 24,7 43.7 48 0. 3 28, 4.3 0 2.4 29,8 42.3 kva 9 6 69 7 39 3.7 9.2 62.8 68.3 3, 62. 68.9 73.1 79. 41,0 64.9 71. 7.9 82. 42,9 kw 47.2 2.0.2 60 31.2 43.0 47.3 0.2 4.6 28,4 0.0.1 8. 63.6 32,8 1.9 7.2 60.7 66.0 34,3 Electric Power Generation 3

Efficiencies 400 V - 0 Hz ( P.F.: 0.8) (... P.F.: 1 ) 87.3 91.4.3 LSA 42.3 VS1 92 91.8 91. 88. 88.3 87.3 86.8.1 93.2 88.6.9 LSA 42.3 S 93.2 92.9.6 89.1 89.6 0 1 2 3 40 kva 0 40 0 60 70kVA 88.2 LSA 42.3 VS2 91.8 92.3 92 91.7 89 88.8 86.2 87.7 87.2.9 89.4 93.6 93.8 91.4 LSA 42.3 93.3.9 93.1 89.9 89.4 0 1 2 3 40 kva 0 40 0 60 70kVA 89.1 87.3 LSA 42.3 VS3 92.4 92.8 92.4 92.1 89.8 89.4 88.3 87.8. 89 91.3 LSA 42.3 93.8 93.3 91 89.6 0 1 2 3 40 kva 0 40 0 60 70kVA 89.1 87.7 92.8 LSA 42.3 S4.7 93.4.8 93.2.1 89.7 91.3 89.8 LSA 42.3 93.9 94.1 93.7 91.8 91.4.4 89.9 0 1 2 3 40 kva 0 40 0 60 70kVA Reactances (%). Time constants (ms) - Class H / 400 V VS1 VS2 VS3 S4 S Kcc Short-circuit ratio 0.4 0.1 0.48 0.3 0.46 0.43 0.47 0.44 Xd Direct-axis synchro. reactance unsaturated 240 249 261 229 262 27 264 283 Xq Quadrature-axis synchro. reactance unsaturated 144 149 16 137 17 16 18 169 T do No-load transient time constant 733 79 3 8 8 914 931 962 X d Direct-axis transient reactance saturated 16.3 16.4 16.2 13.0 14.8 1.0 14.1 14.7 T d Short-circuit transient time constant 0 0 0 0 0 0 0 0 X d Direct-axis subtransient reactance saturated 8.1 8.2 8.1 6. 7.4 7. 7.0 7.3 T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated 11. 11.6 11. 9.2.6.7.1. Xo Zero sequence reactance unsaturated 0.78 0.46 0.88 0.73 0.23 0.2 0.84 0.43 X2 Negative sequence reactance saturated 9.88 9.91 9.82 7.89 9.02 9.12 8.61 8.93 Ta Armature time constant 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 Other class H/400 V data io (A) No-load excitation current (/) 0./0. 0.2/0.8 0.1/0.79 0.49/0.7 0.49/0.7 0.46/0.71 0./0.78 0./0.77 ic (A) On-load excitation current (/) 1.74/2.66 1.72/2.63 1.77/2.71 1.4/2.36 1.73/2.66 1.7/2.68 1.86/2.86 2.04/3.13 uc (V) On-load excitation voltage (/) 29.6/19.2 29.2/18.9 29.9/19.3 26/16.8 29.1/18.8 29/18.8.6/19.8 32.8/21.2 ms Response time ( U = % transient) < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms kva Start ( U = % cont. or ( U = % trans.) 1.7 6 67.7 92 92 3. 11 138 kva Start ( U = % cont. or ( U = % trans.) 9.6 64.3 76.1 93.1 93.1 3.2 4.9 116.8 % Transient U (on-load 4/4) - P.F.: 0.8 LAG 16.3 16.3 16.2 14.3 1.4 1. 1 1.3 % Transient U (on-load 4/4) - P.F.: 0.8 LAG 13.8 13.8 13.7 12.2 13.1 13.2 12.8 13 W No-load losses 719 713 762 861 861 879 29 11 W Heat dissipation 2894 17 3371 3704 4022 4396 091 4 Electric Power Generation

Transient voltage variation 400V - 0 Hz % 2 Phase loading () VS1 VS2 VS3 S4 S % 2 Phase loading ( & PMG) VS1 VS2 VS3 S4 S 1 1 0 40 1 kva 0 40 1 kva Load shedding () Load shedding ( & PMG) VS1 VS2 VS3 S4 S VS1 VS2 VS3 S4 S Voltage rise Voltage rise 0 40 1 kva 0 40 1 kva kva at PFØ 0.8 Motor starting () Motor starting ( & PMG) VS1 VS2 VS3 S4 S VS1 VS2 VS3 S4 S 13% 0 40 1 160 0kVA 4.8 locked rotor kva at PF Ø 0.6 0 40 1 160 0kVA locked rotor kva at PF Ø 0.6 1) For a starting P.F. other than 0.6, the starting kva must be multiplied by K = Sine P.F. / 0.8 Calculation example for a different P.F. other than 0.6: Starter motor kva calculated at 0.4 P.F. = 40 kva > Sin P.F. 0.4 = 0.916 > K = 1.14 > kva corrected = 4.8 kva > Voltage dip corresponding to = 13%. 2) For voltages other than 400V (Y), 2V ( ) at 0 Hz, then kva must be multiplied by (400/U) 2 or (2/U) 2. Electric Power Generation

Efficiencies 4 V - 60 Hz ( P.F.: 0.8) (... P.F.: 1 ) LSA 42.3 VS1 92 92 91 91.8 86.3 88.6 88.8 87.7 88.1 84.7 0 1 2 3 40 4 0kVA LSA 42.3 VS2 91. 92.3 92.2 92 87.2 89.1 89.3 88..6 88 LSA 42.3 S 92.9 93.3 92.9 89.2.9.9.2 89.8 87.9 0 40 0 60 70 kva LSA 42.3 93.8 93.3 93.6 93.4.1 91.4 91.3..1 88.8 0 1 2 3 40 4 0kVA 0 40 0 60 70 kva 88.2 86.7 92.1 LSA 42.3 VS3 92.8 92.6 89.9 89.9 92. 89.1 88.6 LSA 42.3 93.8 93.3 91.3 91 89.6. 89 0 1 2 3 40 4 0kVA 0 40 0 60 70 kva LSA 42.3 S4 93.4 92.4 88.1.6 86.9 91.1 93.4.6.4. 89.3 93.6 LSA 42.3 94.1 93.9 91.8 91.7 93.8 91.6 0 1 2 3 40 4 0kVA 0 40 0 60 70 kva Reactances (%). Time constants (ms) - Class H / 4 V VS1 VS2 VS3 S4 S Kcc Short-circuit ratio 0.2 0.49 0.46 0.1 0.44 0.41 0.4 0.42 Xd Direct-axis synchro. reactance unsaturated 22 260 272 239 273 287 27 294 Xq Quadrature-axis synchro. reactance unsaturated 11 16 163 143 163 172 16 176 T do No-load transient time constant 733 79 3 8 8 914 931 962 X d Direct-axis transient reactance saturated 17.2 17.1 16.9 13. 1. 1.7 14.7 1.3 T d Short-circuit transient time constant 0 0 0 0 0 0 0 0 X d Direct-axis subtransient reactance saturated 8.6 8. 8.4 6.7 7.7 7.8 7.3 7.6 T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated 12.1 12.1 12.0 9.6 11.0 11.2.. Xo Zero sequence reactance unsaturated 0.46 0.83 0.31 0.26 0.69 0.0 0.97 0.86 X2 Negative sequence reactance saturated.37.3.24 8.22 9.39 9. 8.97 9. Ta Armature time constant 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 Other class H/4 V data io (A) No-load excitation current (/) 0./0. 0.2/0.8 0.1/0.79 0.49/0.7 0.49/0.7 0.46/0.71 0./0.77 0./0.77 ic (A) On-load excitation current (/) 1.76/2.69 1.73/2.6 1.77/2.72 1.4/2.36 1.73/2.66 1.7/2.68 1.84/2.82 1.99/3.06 uc (V) On-load excitation voltage (/).2/19.3 29.7/19.3/19.4 26.4/16.9 29.4/18.8 29./18.8.9/19.7 32.9/21.1 ms Response time ( U = % transient) < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms kva Start ( U = % cont. or ( U = % trans.) 63.3 68.1 82 111.8 111.8 124.7 146.9 16.6 kva Start ( U = % cont. or ( U = % trans.) 71.4 76.9 92.6 121.8 121.6 133.8 137.9 12.2 % Transient U (on-load 4/4) - P.F.: 0.8 LAG 16.8 16.8 16.6 14.7 1.8 1.9 1.4 1.7 % Transient U (on-load 4/4) - P.F.: 0.8 LAG 14.1 14.1 14.0 12. 13.4 13. 13.0 13.3 W No-load losses 21 16 87 1229 1229 128 1462 191 W Heat dissipation 3389 30 3914 397 4312 4709 1 917 6 Electric Power Generation

Transient voltage variation 4V - 60 Hz Phase loading () Phase loading ( & PMG) % 2 VS1 VS2 VS3 S4 S % 2 VS1 VS2 VS3 S4 S 1 1 0 40 1 kva 0 40 1 kva Load shedding () Load shedding ( & PMG) VS1 VS2 VS3 VS1 VS2 VS3 S4 S S4 S Voltage rise Voltage rise 0 40 1 kva 0 40 1 kva Motor starting () Motor starting ( & PMG) VS1 VS2 VS3 S4 S VS1 VS2 VS3 S4 S 12% 0 40 1 160 0kVA 4.8 locked rotor kva at PF Ø 0.6 0 40 1 160 0kVA locked rotor kva at PF Ø 0.6 1) For a starting P.F. other than 0.6, the starting kva must be multiplied by K = Sine P.F. / 0.8 Calculation example for a different P.F. other than 0.6: Starter motor kva calculated at 0.4 P.F. = 40 kva > Sin P.F. 0.4 = 0.916 > K = 1.14 > kva corrected = 4.8 kva > Voltage dip corresponding to = 12%. 2) For voltages other than 4V (Y), 277V ( ), 240V (YY) at 60 Hz, then kva must be multiplied by (4/U) 2 or (277/U) 2 or (240/U) 2. Electric Power Generation 7

3-phase short-circuit curves at no load and rated speed (star connection Y) LSA 423 VS1 000 00 0 1 0 00 000 000 LSA 423 VS2 00 0 1 0 00 000 000 LSA 423 VS3 00 0 000 1 0 00 000 LSA 423 S4 00 0 1 0 00 000 Influence due to connection Curves shown are for star (Y) connection. For other connections, use the following multiplication factors: - Series delta : current value x 1.732 - Parallel star : current value x 2 8 Electric Power Generation

3-phase short-circuit curves at no load and rated speed (star connection Y) 000 LSA 423 S 00 0 1 0 00 000 LSA 423 000 00 0 1 0 00 000 LSA 423 000 00 0 1 0 00 000 LSA 423 000 00 0 1 0 00 000 Influence due to short-circuit Curves are based on a three-phase short-circuit. For other types of short-circuit, use the following multiplication factors. 3-phase 2-phase L/L 1-phase L/N Instantaneous (max.) 1 0.87 1.3 Continuous 1 1. 2.2 Maximum duration (/PMG) sec. sec. 2 sec. Electric Power Generation 9

Single bearing dimensions LSA 42.3 - S.A.E. 3 L Ø 4 + 0-0.127 Ø N AH 3-0.00-0.0 Ø BX LB Ø P Ø N AH 3 + 0-0.127-0.00-0.0 Ø BX Xg 3 2 L LB 89 32 32 89 9 Optional PMG Ø 23 XBG Ø 11 holes equid. over Ø M 4 Access to terminals Cable outlet X Ø Y holes equid. over Ø U 1 Ø 64 Access to AVR H 264 (270.:) +1-3 AIR OUTLET T LA C AIR OUTLET T LA C 78. 14 B INLET 137 97 Optional H = 22 A2 A1 Dimensions (mm) and weight (kg) H = 1 (Standard) H = 22 (Option) Coupling L LB Xg Masse (kg) C B A1 A2 C B A1 A2 Flange 2 3 4 LSA 42.3 VS1 6 03 237 117 260 18 7 279 299 23 400 36 Flex plate LSA 42.3 VS2 6 03 242 122 260 18 7 279 299 23 400 36 11 1/2 x x - LSA 42.3 VS3 6 03 22 133 260 18 7 279 299 23 400 36 x x x LSA 42.3 S4 6 48 27 16 260 18 7 279 312. 23 400 36 8 - x x LSA 42.3 S 6 48 27 16 260 18 7 279 312. 23 400 36 7 1/2 - x x LSA 42.3 60 88 287 181 260 18 7 279 312. 23 400 36 LSA 42.3 60 88 29 186 260 18 7 279 312. 23 400 36 LSA 42.3 662 622 3 187 260 18 7 279 312. 23 400 36 Flange (mm) Flex plate (mm) S.A.E. P N M XBG T LA S.A.E. BX U X Y AH 4 406 361.9 381 12 6 122 11 1/2 32.42 333.38 8 11 39.6 3 42 409.8 428.62 12 112. 314.32 29.28 8 11 3.8 2 4 447.67 466.72 12 6 111 8 263.2 244.48 6 11 62 7 1/2 241.3 222.2 8 9.2 Xr Torsional analysis data Ø 18 Ø 60 Lr Ø 41 Ø Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Flex plate S.A.E. 7 1/2 Flex plate S.A.E. 8 Flex plate S.A.E. Flex plate S.A.E. 11 1/2 Type Xr Lr M J Xr Lr M J Xr Lr M J Xr Lr M J LSA 42.3 VS1 279 26.2 4.36 0.29 277 8 4.68 0.2246 274 49.8 46.13 0.2363 272 3.6 46.62 0.2843 LSA 42.3 VS2 282 26.2 47.36 0.2337 2 8 47.68 0.2374 277 49.8 48.13 0.2491 274 3.6 48.62 0.2611 LSA 42.3 VS3 287 26.2 1.41 0.292 286 8 1.73 0.2629 283 49.8 2.18 0.2746 281 3.6 2.67 0.2866 LSA 42.3 S4 3 71.2 61.49 0.317 8 603 61.81 0.37 6 94.8 62.26 0.3324 4.6 62.7 0.3444 LSA 42.3 S 3 71.2 61.49 0.317 8 603 61.81 0.37 6 94.8 68.18 0.364 4.6 62.7 0.3444 LSA 42.3 32 611.2 67.41 0.3491 323 643 67.73 0.328 321 634.8 68.18 0.364 319 6.6 68.67 0.376 LSA 42.3 3 611.2 70.42 0.3683 328 643 70.74 0.372 326 634.8 71.18 0.3837 324 6.6 71.68 0.397 LSA 42.3 344 641.2 77.49 0.4141 342 673 77.81 0.4178 340 664.8 78.2 0.429 338 60.6 78.7 0.441 NOTE : Dimensions are for information only and may be subject to modifications. Contractual 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. The torsional analysis of the transmission is imperative. All values are available upon request. Electric Power Generation

Two bearing dimensions Ø P 1 M16 hole 36 depth Ø N + - 0.127 0 Ø 48 k6 LB 82 Xg 89 32 32 89 47 11 AIR OUTLET 6 139 18 3 2 213 18 C 172 L 14 AIR INLET 137 4x2 M holes on Ø M to 4 Access to terminals Access to the AVR Optional PMG Cable outlet Ø 23 97 4 M holes to unusable 1 1. 279 3 1 14 1 M12 hole 18 depth 9 264 (270.:) +1-3 1 Dimensions (mm) and weight (kg) Type L LB N M P C Xg Weight (kg) LSA 42.3 VS1 6 28 361.9 381 406 189.2 242 129 LSA 42.3 VS2 6 28 361.9 381 406 189.2 247 134 LSA 42.3 VS3 6 28 361.9 381 406 189.2 27 14 LSA 42.3 S4 6 73 361.9 381 406 2.7 2 170 LSA 42.3 S 6 73 361.9 381 406 2.7 2 170 LSA 42.3 69 613 361.9 381 406 2.7 292 1 LSA 42.3 69 613 361.9 381 406 2.7 0 1 LSA 42.3 72 643 409.8 428.62 4 2.7 314 7 Torsional analysis data Xr Ø 48 Ø 0 Ø 60 Lr Ø 41 Ø Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Type Xr Lr M J LSA 42.3 VS1 238 603 4.18 0.213 LSA 42.3 VS2 240 603 47.18 0.2263 LSA 42.3 VS3 24 603 1.23 0.218 LSA 42.3 S4 267 648 61.31 0.96 LSA 42.3 S 267 648 61.31 0.96 LSA 42.3 281 688 67.23 0.3417 LSA 42.3 286 688 70.23 0.3609 LSA 42.3 299 718 77.29 0.4066 NOTE : Dimensions are for information only and may be subject to modifications. Contractual 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. The torsional analysis of the transmission is imperative. All values are available upon request. Electric Power Generation 11

www.leroy-somer.com/epg Linkedin.com/company/Leroy-Somer Twitter.com/Leroy_Somer_en Facebook.com/LeroySomer.Nidec.en YouTube.com/LeroySomerOfficiel Nidec 17. The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as Nidec have an ongoing process of development and reserve the right to change the specification of their products without notice. Moteurs Leroy-Somer SAS. Siège : Bd Marcellin Leroy, CS 01, 1691 Angoulême Cedex 9, France. Capital social : 6 0 12, RCS Angoulême 338 67 28. 42 en - 17.12 / j