Hamilton Microlab STAR Reference Guide

Similar documents
HiSeq Rapid Primer Rehybridization Reference Guide

TruSeq DNA PCR-Free Library Prep Protocol Guide

TruSeq Nano DNA Library Prep Protocol Guide

TruSight HLA Sequencing Panel Protocol Guide

TruSight Cardio Sequencing Kit Protocol Guide

Single Cell Washing and Handling. Introduction 1 Preparation 3 Cell Wash Protocol 5 Technical Assistance 7

ForenSeq DNA Signature Prep Protocol Guide

TruSeq Custom Amplicon v1.5 Protocol Guide

Illumina Free Adapter Blocking Reagent

NovaSeq Series. Custom Primers Guide

A Technical Guide to Aneuploidy Calling with VeriSeq PGS

TruSight Tumor 15 Protocol Guide

Introduction to the NextSeq System

TruSeq Small RNA Library Prep Protocol Guide

Normalization, Dilution and Transfer Methods for the Maxprep TM Liquid Handler Technical Manual

AltoStar Connect Software Manual IVD 01/2018 EN

TruSight Tumor 26 Protocol Guide

Attracting and Engaging Talent in Mid-Market Organizations

Automated Plate Replication

isolight System Guide For Research Use Only. Not for use in diagnostic procedures.

TruSight HLA Sequencing Panel Reference Guide

Evolution TM P 3 Precision Pipetting Platform

Process security technologies. for the Freedom EVO liquid handling platform

cobas s 201 system for NAT Donor Screening One Vision. Many Possibilities.

MiSeq. system applications

ELISA STAR Standard Solutions

VERSANT kpcr Molecular System

FluentControl TM TAKE CONTROL OF TECAN S MOST POWERFUL LIQUID HANDLING WORKSTATIONS

PrepFiler Express and PrepFiler Express BTA Forensic DNA Extraction Kits

easyblood Standard Solutions

Te-Options TWO INSTRUMENTS, UNLIMITED OPTIONS, INDIVIDUAL SOLUTIONS.

Agilent High Sensitivity DNA Kit Guide

Industrial Hygiene in the Genomics Revolution Keith Rego, MS, CSP, CIH Sr. Manager, IH and Chemical Compliance

Maxwell RSC Whole Blood DNA Kit

Hamilton VANTAGE. Start the future

Changing the world of laboratory developed testing

Next Generation Sequencing Method for Illumina TruSeq DNA Sample Preparation Protocol on the Hamilton STAR

foodproof Magnetic Preparation Kit I

TruSight Myeloid Sequencing Panel Reference Guide

Illumina Sequencing Overview

QIAGEN GeneRead QIAact Panel Cleanup Kit Handbook

Set-up, programming and analysis MagNA Pure 96 (Roche)

Dynex DS2 2-Plate ELISA Processing System. Compact Easy to Use Innovative A Perfect Combination.

Applied Biosystems QuantStudio 12K Flex Real- Time PCR System: OpenArray Plate

Fully Automated Library Quantification for Illumina Sequencing on the NGS STAR

May 2016 STAR Q SP/AS User Manual. Version 1. Hamilton Bonaduz AG Via Crusch Bonaduz SWITZERLAND R

Illumina Bio-Rad Single Cell Sequencing For Research Use Only. Not for use in diagnostic procedures.

Table of contents. 1. Introduction

PyroTec PRO Robotic Solution for Endotoxin Detection FAQs Tech Tips

illumina Nanotechnology for a Genomic Revolution

Fast and reproducible amplicon library preparation for HLA typing with the 454 sequencing system

Reagent Kit Guide RNA 6000 Nano Assay. Edition April 2003

Maxwell RSC Blood DNA Kit

Maxwell RSC Buffy Coat DNA Kit

Identity Automation DNA IQ System Protocol for the Tecan Freedom EVO Workstation Automated Protocol #EP039

Maxwell RSC Blood DNA Kit

Fluent Laboratory Automation Workstation for cell-based assays THE SIMPLE WAY TO TAKE THE COMPLEXITY OUT OF CELL BIOLOGY RESEARCH

chemagic STAR New methods for total RNA extraction Standard Solutions Workstation for nucleic acid extraction

PIPETMAX : Automation of the Illumina Nextera XT DNA Library Preparation Kit

Procedure for BSD600-Duet Semi-Automated Dried Sample Punch Instrument

Preparing Samples for Multiplexed Paired-End Sequencing

Dynex DSX 4-Plate ELISA Processing System. Modular Flexible Reliable A Perfect Combination.

Introduction to the MiSeq

ENGLISH USER S MANUAL. compact omnidirectional bar code scanner

DRAFT. Apollo 324 System. Protocol. PrepX-32i DNA Library

QIAcube Pure Efficiency

AccuSEQ Real-Time PCR Detection Software

Procedure for PCR Amplification for Casework

Fluent for Genomic Workflows INCREASED PRODUCTIVITY POWERED BY TECAN S AUTOMATION WORKSTATION

Getting high-quality cytogenetic data is a SNP.

Performing the CTA Carryover PVT Procedure on the LXi or DXC 600i System

QIAGEN Supplementary Protocol

FemINDICAtor qpcr Plant Gender Detection Kit on the BIO-RAD CFX96 Touch Real- Time PCR Detection System Page 1 of 11

TruSeq ChIP Sample Preparation

For detailed instructions about the TruSeq Custom Amplicon library preparation methods, refer to your reference guide.

Use the AccuSEQ Software v2.0 Mycoplasma SEQ module

Automated Apo-ONE Homogeneous Caspase-3/7 Assay Automated Protocol #EP012

qpcr Quantification Guide

UM0925 User manual. Using the M24LR64-R datalogger reference design. Introduction

Genomics: A Paradigm Shift in Animal Breeding

Genomic Information Revolution(s)

AutoLys workstation: Validation of a fully automated forensic sample lysis solution

Maxwell RSC Cell DNA Purification Kit

Automated Wizard SV 96 Genomic DNA Purification System for Cell Culture Samples Automated Protocol #EP018

Illumina TruSeq RNA Access Library Prep Kit Automated on the Biomek FX P Dual-Hybrid Liquid Handler

Maxwell RSC Viral Total Nucleic Acid Purification Kit

Polymer Block Cleaning Kit

Automated CellTiter-Blue Cell Viability Assay Protocol Automated Protocol #EP015

QUICK Guide. System start-up and shutdown 3. Operating panels. State colors. General process description. Device operating modes

Single-Use RNA Preparation

Your Power for Health. CheckExtractor.

Apollo 324 System. PrepX SPIA RNA-Seq Library. Protocol

TruSight DNA Amplicon Sequencing Panel

ROBOTICS APPLICATION NOTE

Automated Wizard SV 96 Genomic DNA Purification System for Tissue Samples

Identity Automation Differex System Protocol for the Beckman Coulter Biomek 4000

Xerox Nuvera Xerox Production Stacker Operator Manual

TruSeq Nano DNA Sample Preparation Guide FOR RESEARCH USE ONLY

ab ERK1/2 (Thr202/Tyr204) In-Cell ELISA Kit

QIAsymphony SP Protocol Sheet

Transcription:

Hamilton Microlab STAR Reference Guide Revision History 1 Introduction 2 ML STAR Components 3 System Software 7 Safety Precautions 8 Perform A Run 10 Deck Layout and Icon Legend 12 Maintenance 14 Troubleshooting 16 Technical Assistance 17 ILLUMINA PROPRIETARY Part # 15070074 Rev. A June 2015

This document and its contents are proprietary to Illumina, Inc. and its affiliates ("Illumina"), and are intended solely for the contractual use of its customer in connection with the use of the product(s) described herein and for no other purpose. This document and its contents shall not be used or distributed for any other purpose and/or otherwise communicated, disclosed, or reproduced in any way whatsoever without the prior written consent of Illumina. Illumina does not convey any license under its patent, trademark, copyright, or common-law rights nor similar rights of any third parties by this document. The instructions in this document must be strictly and explicitly followed by qualified and properly trained personnel in order to ensure the proper and safe use of the product(s) described herein. All of the contents of this document must be fully read and understood prior to using such product(s). FAILURE TO COMPLETELY READ AND EXPLICITLY FOLLOW ALL OF THE INSTRUCTIONS CONTAINED HEREIN MAY RESULT IN DAMAGE TO THE PRODUCT(S), INJURY TO PERSONS, INCLUDING TO USERS OR OTHERS, AND DAMAGE TO OTHER PROPERTY. ILLUMINA DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE IMPROPER USE OF THE PRODUCT(S) DESCRIBED HEREIN (INCLUDING PARTS THEREOF OR SOFTWARE). 2015 Illumina, Inc. All rights reserved. Illumina, 24sure, BaseSpace, BeadArray, BlueFish, BlueFuse, BlueGnome, cbot, CSPro, CytoChip, DesignStudio, Epicentre, GAIIx, Genetic Energy, Genome Analyzer, GenomeStudio, GoldenGate, HiScan, HiSeq, HiSeq X, Infinium, iscan, iselect, MiSeq, NeoPrep, Nextera, NextBio, NextSeq, Powered by Illumina, SeqMonitor, SureMDA, TruGenome, TruSeq, TruSight, Understand Your Genome, UYG, VeraCode, verifi, VeriSeq, the pumpkin orange color, and the streaming bases design are trademarks of Illumina, Inc. and/or its affiliate(s) in the U.S. and/or other countries. All other names, logos, and other trademarks are the property of their respective owners.

Revision History Part # Revision Date Description of Change 15070074 A June 2015 Initial release Revision History Hamilton Microlab STAR Reference Guide 1

Introduction The Hamilton Microlab STAR (ML STAR) is used for automated pipetting of liquid sample material and reagents. Use this guide as a reference to operate and maintain the instrument when performing Illumina protocols on the ML STAR. 2 Part # 15070074 Rev. A

ML STAR Components The ML STAR performs pipetting operations on liquids in containers and transports plates placed on the work surface. Pipetting operations aspirate differing quantities of liquid from a source container, and then transfer the liquid to a target container. The ML STAR work surface, called the deck, holds loadable carriers in multiple sizes. The carriers hold reagent containers, tubes, and microplates. Figure 1 ML STAR Components ML STAR Components A B C D E F G H I J K Pipetting arm Deck Loading tray Front cover Waste slide for CO-RE head tips Waste attachment for CO-RE head tips Pipetting channel, CO-RE head Carrier for microplates, tips Carrier for tubes Autoload unit and barcode reader Waste container for pipetting channel tips The deck of the ML STAR is divided into equal tracks that guide carriers into predetermined positions. The deck has partitions for up to 54 specialized 1 track (1T) carriers for sample tubes, or up to 9 carriers with 6 tracks (6T) for microplates and CO-RE tips. Pipetting Channels The ML STAR has 8 pipetting channels working in parallel for simultaneous transfer of liquids. The dynamic positioning system (DPS) moves each 1000 µl pipetting channel independently on the Y-axis and Z-axis. The pipetting channels use disposable tips and move at a specified height to prevent collisions with other items on the deck. Hamilton Microlab STAR Reference Guide 3

Figure 2 Pipetting Channels with 1000 µl Tips Pipetting Principle The ML STAR is based on the air displacement pipetting principle, which is comparable to the functionality of hand pipettes. Air displacement aspirates and dispenses the liquid into the disposable tip using a plunger. Figure 3 Pipetting Principle Diagram A B C D E Plunger Barrel Tip Air between plunger and liquid Aspirated liquid Liquid Level Detection Capacitive Liquid Level Detection (clld) enables the tip to find the surface of the liquid at the start of an aspiration or dispense step. This feature detects the difference in capacitance between the tip in the air and the tip in the liquid. clld verifies that liquid is in a container, and then calculates the volume. If the volume is less than expected, an error message appears. Each individual channel has the clld functionality. The 96 CO-RE head has clld sensors on the A1 and H12 channels. 4 Part # 15070074 Rev. A

CO-RE Technology The ML STAR picks up a disposable tip using compression-induced O-ring expansion technology, or CO-RE technology. CO-RE technology enables precision tip attachment and positioning without vertical force. This technology improves overall reliability, pipetting speed, and capability. Only use ML STAR CO-RE tips. Other tips do not mount properly and can cause errors. Figure 4 Precision Tip Attachment ML STAR Components CO-RE Gripper The CO-RE gripper is the plate handling tool that 2 pipetting channels pick up during a run. The gripper picks up plates in landscape or portrait orientation, but does not rotate plates. The CO-RE gripper holder for the 2 gripper jaws is mounted on the waste block. Figure 5 CO-RE Gripper CO-RE 96 Probe Head The CO-RE 96 Probe Head is a high-throughput pipettor with 96 pipetting channels that work simultaneously. Each 1000 µl pipetting channel uses the same volume of liquid. Heater Shaker The Hamilton heater shaker (HHS) heats and shakes plates during a run. When the shaking process is complete, plates are unlocked for automatic removal. Figure 6 HHS with Universal Flat Bottom Adapter Hamilton Microlab STAR Reference Guide 5

Carriers CAUTION Do not touch the HHS during a run or shortly after completing a run. The HHS adapters fit to a plate type, which allows optimal heating of samples. Only use labware that complies with the HHS dimensions. The maximum temperature of the HHS is 105 C. The HHS has 2 sensors that monitor and control the temperature. A default threshold temperature protects samples from overheating. Plates, tips, and reagents are placed on carriers that are loaded onto the ML STAR. Every carrier is equipped with at least 2 labels 1 identification label and 1 barcode label. } The identification label is a human-readable label on the front of the carrier with the carrier name and barcode information. The ML STAR software uses the carrier name. } The barcode label is on the back of the carrier and used for automatic identification during the loading process. Items are loaded according to the deck layout of the method. Carrier positions are numbered from back to front and left to right. Load items with barcode labels facing right. Figure 7 Tip Carrier with Labeled Carrier Positions and Barcodes Facing Right A B C Front of carrier Back of carrier Barcode labels facing right User-Supplied Consumables Only use original ML STAR parts and commercially available liquid containers that meet assay specifications. To prevent damage to the pipetting channels and crosscontamination, only use ML STAR disposable CO-RE tips with filters. Tip racks are barcode labeled for automatic identification. Tip carriers hold up to 5 tip racks. 6 Part # 15070074 Rev. A

System Software The dedicated ML STAR software controls the instrument and accessories. The software is a Windows-based application with a menu-driven interface. Control Software Commands The Run Control toolbar contains the following command options to control the operation of the current method. Only use command options that are applicable for the assay. System Software Table 1 Operation Commands Icon Command Analyze Only Analyze for syntax errors when the run control is opened. This functionality is not applicable. Start or Run Process Starts the method. Pause Pauses the current run after the current pipetting operation is complete. An audible beep indicates that the run is paused. Paused runs can be resumed or aborted. Single Step Performs the next step in the method and then pauses the run. Abort Cancels the current operation and ends the run. Control Panel Opens the control panel, which includes commands to initialize the instrument and move mechanical components before starting a method. This functionality is not applicable. Incubation Timer Aborting A Run The Timer Display screen shows the incubation completion time for steps performed on the ML STAR. For steps performed on other equipment, set a separate timer. During incubation, complete other work or prepare for the next step. To abort a run, perform the following steps. 1 Click the Abort button on the Run Control toolbar. 2 Click Abort to confirm, or click Cancel to continue the method. 3 Open the Hamilton App Launcher and restart the method. The Abort button is active for the entire duration of a method. If a problem is identified early in the procedure, restart the method. If a problem is identified late in the procedure, do not proceed with the next step of the workflow. Hamilton Microlab STAR Reference Guide 7

Safety Precautions Safety Labeling Carefully review safety information before operating the ML STAR. This section describes safety labeling on the instrument, electrical and biological safety considerations, and potential hazards associated with operation. Safety labels are affixed to the instrument in specific locations to provide information and appropriate warnings. Figure 8 Safety Label Locations Table 2 Label Descriptions Location Label Description A Pipetting arm Never attempt to move the pipetting arm manually. B C Biohazard warning Deck contains biohazardous or chemically contaminated materials. Power connections Only connect to earth-grounded outlet. D Connection to PC Only use appropriately shielded cables. USB connection To avoid signal interference, do not exceed a cable length of 5 m (16.4 feet). Laser beam Do not stare into the beam of the class 2 laser. E F Biohazard warning Waste contains biohazardous or chemically contaminated materials. Moving parts Keep the cover closed while parts are moving. If the cover is opened, the run is stopped. 8 Part # 15070074 Rev. A

Electrical Safety Location Label Description On HHS Hot surface Avoid contact with the Hamilton Heater Shaker (HHS). The surfaces are hot and can cause burns. Before removing a mechanical or electrical component, turn off the ML STAR and disconnect the main electricity supply from the instrument and the control computer. Biological Hazard Precautions Safety Precautions Observe the following best practices when working with biohazardous samples: } Perform regular maintenance procedures for cleaning and decontamination. For more information, see Maintenance on page 14. } Wear gloves when handling the pipetting arm and channels, carriers, racks, containers, and tips. } Do not touch discarded tips in the waste containers. Used tips are automatically dropped into the waste containers at specific points in the method. Operational Safety Requirements Observe the following laboratory practices when operating the ML STAR: } Wear suitable protective clothing, safety glasses, and protective gloves. } Take care when troubleshooting an instrument malfunction, especially when there is risk of contamination from spilled liquids. Completion of a certified training course is required for any persons operating the ML STAR and the computer running the software. Failure to follow the procedures as described can result in errors or malfunction. Transport and Installation The Hamilton service technician is responsible for the installation qualification (IQ) and operation qualification (OQ). The clinical validation is the responsibility of the laboratory. Hamilton Microlab STAR Reference Guide 9

Perform A Run Best Practices 1 Turn on the ML STAR. 2 Turn on the instrument control computer and enter your user name and password. 3 From the ML STAR desktop, open the Hamilton App Launcher. 4 Select Maintenance and Verification and perform the required maintenance procedures. For more information, see Maintenance on page 14. 5 Select the appropriate program. 6 Select the appropriate method. 7 Enter your user name and password, and then click OK. 8 Follow the on-screen instructions to load the ML STAR carriers. Click OK after loading each carrier. 9 Click OK to verify all labware positions and begin the run. To ensure effective use, maintain sample and reagent tracking, prevent harm to the operator or instrument damage, perform the following best practices. Category Plates Best Practices Place the barcode label on side A, the edge closest to column 12, as shown in the following figure. Position the barcode label at the top of the plate, centered and parallel to the edge. Make sure that it does not protrude above or below the edge of the plate. Load plates so that the A1 well is oriented to the left and rear of the carrier. Tips Do not mix tip size and type in the same tip rack. Load tip racks as they are provided in the original packaging. Tips are individually labeled with a barcode for identification. Discard used tips. Do not empty the tip waste during a run. Do not leave tips on the pipetting channels in between runs or overnight. Doing so can cause deformation of the channel O-ring and can result in early wear on the channel and unreliability in tip pickups. Run the daily maintenance procedure to remove the tips. 10 Part # 15070074 Rev. A

Category Reagents General Best Practices When pouring liquid into the containers, make sure that there is no foam or bubbles on the surface of the liquid. Do not overfill the liquid containers. Do not exchange the positions of plates or tubes after the barcodes are scanned. Do not attempt to lift single-track carriers solely by the finger-hook handles. Perform periodic maintenance as required. Perform A Run Hamilton Microlab STAR Reference Guide 11

Deck Layout and Icon Legend The pre-pcr lab ML STAR has 10 carriers and the post-pcr lab ML STAR has 12 carriers. Refer to the following figures for the general deck layouts of the instruments. Figure 9 Pre-PCR Lab ML STAR Deck Figure 10 Post-PCR Lab ML STAR Deck A B C Carrier positions numbered from back to front Track locations numbered from left to right Heater Shaker Refer to the following table for the track location of each carrier. Table 3 Carrier Numbers and Track Locations Carrier Track Locations Carrier Track Locations 1 1 6 7 37 42 2 7 12 8 43 3 13 18 9 44 4 19 24 10 45 5 25 30 11* 46 6 31 36 12* 47 *Post-PCR instrument only. 12 Part # 15070074 Rev. A

Refer to the following table for the labware description of each icon. Table 4 Example Deck Layout Icons and Labware Description Icon Labware Description Icon Labware Description Hamilton CO-RE tips, 50 µl, sterile, filtered 96-well reservoir Hamilton CO-RE tips, 300 µl, sterile, filtered Axygen 384-well plates/ Roche 384-well plates Covaris Rack/ 96-well TCY plate/ 96-well midi plate/ 96-well super midi plate 96-well black FLUOTRAC plates 60 ml reservoir Eppendorf tube Reagent tube CST holder Deck Layout and Icon Legend Hamilton Microlab STAR Reference Guide 13

Maintenance Maintenance procedures include daily maintenance, weekly maintenance, and preventive service every 6 months. If maintenance procedures are not completed, the instrument cannot perform a run. Perform the required verification process within the required intervals and document the verification process. Only certified technicians are authorized to perform mechanical maintenance on the ML STAR. Required Materials } 70% ethanol (EtOH) } Deionized water } Lint-free cloth } Microcide SQ Broad Spectrum Disinfectant } Personal protective equipment NOTE Do not spray Microcide SQ directly onto electrical components. Daily Maintenance Procedure The daily maintenance procedure consists of automated steps, visual inspection, and waste disposal. Automated steps check the tightness of the pipetting channel and the capacitive liquid level (clld) detection. 1 After starting the daily maintenance method, visually inspect the deck. If the deck is clean, proceed with daily maintenance. If the deck is not clean, cancel daily maintenance and perform a weekly maintenance. 2 When prompted, empty the CO-RE head tip and channel tip waste containers. 3 When prompted, click OK. 4 Remove the tip eject plate from the waste section. Spray Microcide SQ onto the waste section and wipe. 5 Reinstall the tip eject plate. 6 Click OK. Weekly Maintenance Procedure The daily maintenance procedure consists of automated steps, visual inspection, manual cleaning, and waste disposal. Automated steps check the tightness of the pipetting channel and the capacitive liquid level (clld) detection. 1 After starting the weekly maintenance method, clean all carriers with Microcide SQ or 70% EtOH and allow to dry. If the carriers are heavily soiled, soak the carriers in a solution of Microcide SQ. 2 Clean the tube inserts with Microcide SQ or 70% EtOH 3 Visually inspect each carrier for damage or barcode scratches. If damaged, replace the carrier. 14 Part # 15070074 Rev. A

4 Open the front cover and wipe the deck with a cloth saturated with Microcide SQ or 70% ethanol. Make sure that the slide blocks are clean, and then close the front cover. 5 When prompted, empty the CO-RE head tip and channel tip waste containers. 6 Remove the tip eject plate from the waste section. Spray Microcide SQ onto the waste section and wipe. 7 Reinstall the tip eject plate. 8 Clean the laser scanner window of the barcode reader with a lint-free cloth lightly soaked in 70% ethanol. 9 Click OK. Maintenance Decontamination Procedure Decontaminate the instrument after any biohazardous fluid spills on the ML STAR deck. 1 Use a lint-free wipe to contain the spill. 2 Wipe the spill and affected area using Microcide SQ, and then wait 10 minutes. 3 Wipe with deionized water to remove all traces of Microcide SQ. 4 Dry the area with a clean wipe. Preventive Maintenance and Verification An authorized service technician performs preventive maintenance, which is required every 6 months, or after a maximum of 200 days. This procedure is performed during instrument installation and required after instrument service or repair. If verification procedures are not completed successfully, a run cannot be performed. Hamilton Microlab STAR Reference Guide 15

Troubleshooting Most errors can be corrected without aborting the run. If an error occurs, follow the troubleshooting commands in the error message. The software includes an automatic recovery feature for some errors. If an error cannot be corrected, contact your Illumina representative. Barcode Reading Errors The ML STAR methods check for an expected barcode mask for all items. If the labware barcode does not match what is expected, or a barcode is placed incorrectly, a barcode error is triggered. To correct the error, select from the following options: } Click Repeat, and then click Execute to repeat scanning at a slower speed. } Click Barcode and manually scan or enter the barcode. Insufficient Number of Tips If the ML STAR detects an insufficient number of tips, replace the tip rack. In the error message, click Repeat, and then click Execute. Insufficient Reagent Volumes The ML STAR uses the tips and capacitive liquid level detection (clld) to check the volumes of the reagents. If volumes are insufficient, add more reagent to the container, and then select from the following options: } Click Repeat, and then click Execute to repeat the step. } Click Bottom to pipette from the bottom of the reagent container, and then click Execute. CO-RE Grip Errors If the system aborts with the CO-RE gripper or CO-RE tips on the pipetting channels, follow the on-screen instructions to check the traverse height. } If the path to the waste bar is not clear, click Yes. The instrument completes the abort and the channels do not move to the waste bar. Open the control panel on the Run Control and click Initialize Instrument to remove the CO-RE grips or tips before the next run. } If the path to the waste bar is clear, click No. Follow the on-screen instructions to check positions under specified channels. Click Yes to replace the CO-RE grips. 16 Part # 15070074 Rev. A

Technical Assistance For technical assistance, contact Illumina Technical Support. Table 5 Illumina General Contact Information Website Email www.illumina.com techsupport@illumina.com Table 6 Illumina Customer Support Telephone Numbers Region Contact Number Region Contact Number North America 1.800.809.4566 Italy 800.874909 Australia 1.800.775.688 Netherlands 0800.0223859 Austria 0800.296575 New Zealand 0800.451.650 Belgium 0800.81102 Norway 800.16836 Denmark 80882346 Spain 900.812168 Finland 0800.918363 Sweden 020790181 France 0800.911850 Switzerland 0800.563118 Germany 0800.180.8994 United Kingdom 0800.917.0041 Ireland 1.800.812949 Other countries +44.1799.534000 Technical Assistance Safety Data Sheets Safety data sheets (SDSs) are available on the Illumina website at support.illumina.com/sds.html. Product Documentation Product documentation in PDF is available for download from the Illumina website. Go to support.illumina.com, select a product, then click Documentation & Literature. Hamilton Microlab STAR Reference Guide 17