A demonstration of the antimicrobial effectiveness of various copper surfaces

Similar documents
Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

Join the movement to continuously kill bacteria.

Killing of Bacteria by Copper Surfaces Involves Dissolved Copper

Featuring. Devices made with CuVerro Antimicrobial Copper Surfaces. EPA registered touch surfaces

HARDWARE MADE WITH BACTERICIDAL COPPER

February 3, 2014 hs-mf

Assessment of Antibacterial Efficacy of Goldshield against MRSA and VRE

THERMAL SPRAY COATINGS

Test Method of Specified Requirements of Antibacterial Textiles for Medical Use FTTS-FA-002

ORIGINAL ARTICLE. H.T. Michels 1, J.O. Noyce 2 and C.W. Keevil 2. Abstract

DID YOU KNOW? Acquired Infections (HAI s) reported every year!

Alpha HydroMAID Cleaning Effectiveness of the Alpha HydroMAID Cleaning System versus Conventional Mopping

Microbial Survival. Created on 2/25/ :05 AM

Test Organisms: Staphylococcus aureus (ATCC 6538) Escherichia coli (ATCC 11229) Pseudomonas aeruginosa (15442)

Result:COMPLETE Report Date: December 28 th, 2015

ATP ATP ATP ATP ATP 2017:27:45-52 X ) [1,2] [2-4] DOI: /ICJ (04) #3080

Decontamination Effectiveness of Esco Celsafe CO2 Incubator Sterilization Feature using High Heat Temperature By Bekti Tri Sumaryati

FINAL REPORT. Bacterial Survival on Glass and Laminated Wood Surfaces Exposed to PURE-LIGHT Coated LED Light Bulbs. Order Number:

Laser assisted Cold Spray

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

Repetition: Electrochemistry

ASSESSMENT OF THE MICROBICIDAL ACTIVITY OF AN ACCELERATED HYDROGEN PEROXIDE- BASED FORMULATION (AHP-5) AGAINST VRE AND MRSA

INTRODUCTION Sanitization sterilization Antibiotics Bactericidal Bacteriostatic Antiseptics disinfectants

Dryflex. Antimicrobial TPEs

The Effect of Air Pockets on the Efficiency of Disinfection of Respiratory Equipment by Pasteurization

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

PRESERVATIVE EFFICACY TEST FOR COSMETIC PRODUCT

Cold Spray Action Team Materials Characterization of Pure Copper Consolidated by Liquid Particle Acceleration and the Cold Gas- Dynamic Spray Process

ENVR 421 Laboratory #1: Basic Bacteriology Techniques

Aseptic Techniques. A. Objectives. B. Before coming to lab

RETHINK HOW YOU CLEAN REPLACE TRADITIONAL CAUSTIC CHEMICALS IMPROVE EMPLOYEE SAFETY & PRODUCTIVITY SAVE TIME & MONEY IMPROVE SUSTAINABILITY

Biocidal Surface Test - Clinell Wipes ~ Project Report Prepared for GAMA Healthcare Ltd ~ Huddersfield Microbiology Services Oct 06

Consolidation of Magnesium Alloys Using Cold Spray. Theresa Dillon, Victor Champagne, and Matthew Trexler US Army Research Laboratory.

MICROBIOLOGY #2 PREPERATION AND STERILIZATION OF CULTURE MEDIA

The AOAC Germicidal Spray Products as Disinfectants

EVALUATION OF THE HYGIENE STATUS IN SEVERAL MEAT AND DAIRY PROCESSING ESTABLISHMENTS IN R.MACEDONIA

3.0. Materials and methods

INTRODUCTION Contaminated serial dilution countable plates

Microbiological Methods

BIOCOTE. BioCote treatment reduces contamination of laboratory equipment. Introduction

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

endurocide SPORICIDAL HOSPITAL DISPOSABLE CURTAINS

Analysis of Surface Properties of Al 2 O 3 Coating over Mild Steel Using Plasma Spray Process

TRYPTIC SOY AGAR (TSA) WITH LECITHIN AND TWEEN 80

Novel Cold Spray Nanostructured Aluminum. Aberdeen Proving Ground Maryland USA 2 University of Central Florida

KILL TIME STUDIES Antimicrobial Activity of Advanced Cellular Silver (ACS) 200 Using Methicillin resistant Staphylococcus aureus (MRSA)

Institute for Diagnostic Imaging Research

SonoSteam. Hanieh Musavian, SonoSteam FORCE Technology. Teknologi der kun anvender damp-ultralyd, derfor ingen kemi.

Environmental Surveillance FIDSSA Dr Ben Prinsloo Medical Microbiologist

55 Industrial Park Road Boothbay, ME USA

ASEPTIC TRANSFER & PURE CULTURE TECHNIQUES

High Pressure Cold Spray Makes Structural Repairs Possible

Lab Exercise #4 Microbial Control Lab Exercise #4 Control of Microorganisms: Physical, Chemical and Chemotherapeutic

ENVIROCIDE. Technical Bulletin

SilvaClean Antimicrobial Laundry Additive

Impact of Room Location on UV-C Irradiance and UV-C Dosage and Antimicrobial Effect Delivered by a Mobile UV-C Light Device

Terminal Disinfection in Hospitals with Quaternary Ammonium Compounds by Use of a Spray-Fog Technique

Plasma Science and Technology

Submitted May 16, May 23, 2014 BY:

DISINFECTION QUALIFI CATION TESTING CONSIDERATIONS FOR THE ASEPTIC AND CLEANROOM MANUFACTURING ENVIRONMENT

WELDING Topic and Contents Hours Marks

LABORATORY #2 -- BIOL 111 BACTERIAL CULTIVATION & NORMAL FLORA

Puritan Environmental Sampling Kit (ESK )

á61ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: MICROBIAL ENUMERATION TESTS

Dealer Bulletin. Re: OPTIM 33TB; 3 Minute Fungicidal Claim. OPTIM 33TB Contact Times* To: All Authorized SciCan Dealers Canada

The Efficacy of 300 ppm Peracetic Acid from Perasan MP-2 and MP-2C on E. Coli O157:H7 Inoculated Meat Surfaces

Antimicrobial effectiveness evaluation of Isocide powder coating versus stainless steel plate

Microbiological Methods

Mapecoat ACT 196. Advanced Coating TecHnology WALL COATINGS WITH SUPERIOR PERFORMANCE

Evaluation of a Novel Non-Sterile Glove Dispensing System Uyen Nguyen

bottom of the cylindrical chamber. The chamber is sterilized by dipping in alcohol and flaming. Placing the open end of the

Surface Compatibility and the Use of the SteraMist BIT Systems:

Surface Compatibility and the Use of the SteraMist BIT Systems:

Orthophenylphenol in healthcare environments: a trial related to a new administration method and a review of the literature*

DNA TRANSFORMATION OF BACTERIA RED COLONY REVISED 3/2003

HARD CHROME REPLACEMENT

AIRCRAFT COLD SPRAY REPAIR COLD SPRAY REPAIR SERVICES

METHODS OF COATING FABRICATION

A membrane filter technique for testing disinfectants

Lecture 16 Gas Tungsten Arc welding III & Plasma Arc Welding Keyword: 16.1 Selection of pulse parameters

NIMBUS The Next Generation in Antimicrobial Protection. October, 2010

COMPARING THE ANTIMICROBIAL ACTIVITY OF THE SEMCO 3A TOTAL ENERGY WHEEL WITH OTHER SELECTED ANTIMICROBIAL SURFACE TREATMENTS RESEARCH FINDINGS

Rubber Processing Industry Effluent Treatment and Electricity Production Using Microbial Fuel Cell Technology

BIO & PHARMA ANALYTICAL TECHNIQUES

Accugen Laboratories, Inc.

UNIVERSITEIT GENT. Laboratory of Microbiology K.L. Ledeganckstr. 35 B-9000 Gent (BELGIUM) SOP. Standard Operating Procedure.

FINAL REPORT LOW LEVEL DISINFECTION EVALUATION VIOGUARD KEYBOARD

why your next CO 2 incubator should be 100% pure copper

PURE CULTURE TECHNIQUES

smart antimicrobial additive we will work with you to create unique antimicrobial solutions to fit your product needs PROVEN ANTIMICROBIAL ACTIVITY

Study of Nozzle Clogging During Cold Spray

USN. Hosur : 6A/6B/6C 10ME665. Discuss briefly. 1 a.

High Speed Titanium Coatings by Supersonic Laser Deposition

bottom of the cylindrical chamber. The chamber is sterilized by dipping in alcohol and flaming. Placing the open end of the

FINAL REPORT Efficacy of a Cold Plasma System

Indigo-Clean White Paper: #1 Bactericidal Performance Testing of Indigo-Clean Upon Bacterial Species. Healthcare

Sanitization of ÄKTA pilot 600 using sodium hydroxide

Shrouding of Thermal Plasma Jets Generated by Gas-Water Torch

Cleaning Efficiency of The MicroOne Wipe and Mop Cleaning System

Transcription:

A demonstration of the antimicrobial effectiveness of various copper surfaces Champagne and Helfritch Champagne and Helfritch Journal of Biological Engineering 2013, 7:8

Champagne and Helfritch Journal of Biological Engineering 2013, 7:8 RESEARCH Open Access A demonstration of the antimicrobial effectiveness of various copper surfaces Victor K Champagne 1 and Dennis J Helfritch 2* Abstract Background: Bacterial contamination on touch surfaces results in increased risk of infection. In the last few decades, work has been done on the antimicrobial properties of copper and its alloys against a range of micro-organisms threatening public health in food processing, healthcare and air conditioning applications; however, an optimum copper method of surface deposition and mass structure has not been identified. Results: A proof-of-concept study of the disinfection effectiveness of three copper surfaces was performed. The surfaces were produced by the deposition of copper using three methods of thermal spray, namely, plasma spray, wire arc spray and cold spray The surfaces were then inoculated with meticillin-resistant Staphylococcus aureus (MRSA). After a two hour exposure to the surfaces, the surviving MRSA were assayed and the results compared. The differences in the copper depositions produced by the three thermal spray methods were examined in order to explain the mechanism that causes the observed differences in MRSA killing efficiencies. The cold spray deposition method was significantly more effective than the other methods. It was determined that work hardening caused by the high velocity particle impacts created by the cold spray technique results in a copper microstructure that enhances ionic diffusion, and copper ions are principally responsible for antimicrobial activity. Conclusions: This test showed significant microbiologic differences between coatings produced by different spray techniques and demonstrates the importance of the copper application technique. The cold spray technique shows superior anti-microbial effectiveness caused by the high impact velocity imparted to the sprayed particles which results in high dislocation density and high ionic diffusivity. Background Bacterial growth on surfaces is a cause of concern in many hospitals and food processing industries due to the possibility of increased risk of bacterial infection [1]. The bacterial contamination of hospital surfaces, including patient rooms, nurse stations and kitchens has been extensively documented [2-5]. Contamination of meat and vegetable preparation surfaces, including refrigerators, and conveyors have also been the subject of investigation [6-10]. In addition to topically applied disinfectants, the use of surfaces that can self-disinfect would enhance overall infection prevention. In the last few decades, work has been done on the antimicrobial properties of copper and its alloys against a range of micro-organisms threatening public health in food processing and healthcare applications [11]. The * Correspondence: dennis.j.helfritch.ctr@mail.mil 2 Dynamic Science, Aberdeen, MD, USA Full list of author information is available at the end of the article use of copper and copper alloys for frequently touched surfaces such as door and furniture hardware, bed rails, light switches and food preparation surfaces can help limit microbial infections in hospitals and food dispensing organizations. Michels, et al. [12] show that increasing the copper content of alloys increases antimicrobial effectiveness. The contact killing is so rapid that the production of protective biofilms is not possible [13]. The specific mechanism by which copper affects cellular structures is not yet proven, but the active agent of cell destruction is generally considered to be the copper ion [11,14,15]. Recent studies showed that large amounts of copper ions were taken up by E. coli over 90 min, when cells were applied to copper coupons via an aqueous suspension (a standing drop). When cells were plated on copper using minimum liquid and a drying time of 5 seconds, the accumulation of copper ions by cells was even more dramatic, reaching a high concentration in a fraction of the time. 2013 Champagne and Helfritch; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Champagne and Helfritch Journal of Biological Engineering 2013, 7:8 Page 2 of 6 Figure 1 The plasma spray deposition system. The copper ion level of cells remained high throughout the killing phase, suggesting that cells become overwhelmed by their intracellular copper [15]. The grain structure of the copper material affects ion diffusion and hence affects bacterial destruction by copper ions. The US Environmental Protection Agency (EPA) registers five copper alloys with public health claims [16]. All of the alloys have minimum nominal copper concentrations of 60%. Registration of copper and certain copper alloys such as brass and bronze means that the EPA recognizes these solid materials antimicrobial properties. Products made from any of the registered alloys are legally permitted to make public health claims relating to the control of organisms that pose a threat to human health. Laboratory studies conducted under EPA-approved protocols have proven copper s ability to kill, within 2 hours of contact time, more than 99.9% of the following disease-causing bacteria: Staphylococcus aureus, Enterobacter aerogenes, Escherichia coli O157:H7, Pseudomonas aeruginosa, Vancomycin-resistant Enterococcus faecalis (VRE) and MRSA. Copper surface generation In order to make use of the antimicrobial ability of copper, surfaces that contact skin and foods should be composed of copper or copper alloy. This can be accomplished with solid copper equipment or by means of copper surface coating. In general, cost considerations favour copper coatings over solid structural copper. Various metal spray techniques are available for the purpose of depositing a copper surface onto implements that can transmit microorganisms, and it is desired to identify an optimal deposition method. Accordingly, three metal spray techniques are evaluated with respect to the anti-microbial activity of the copper surfaces produced by each. Plasma spray The plasma spray process shown in Figure 1 uses a DC electric arc to generate a stream of high temperature ionized plasma gas, which acts as the spraying heat source. The coating material, in powder form and carried by an inert gas, is injected into the plasma jet where it is melted and propelled towards the substrate. The plasma spray gun includes a copper anode and tungsten cathode, which are both water cooled. Plasma gas (argon, nitrogen, hydrogen, helium) flows around the cathode and through the anode, which is shaped as a constricting nozzle. The plasma, containing suspended Figure 2 The wire Arc spray deposition system.

Champagne and Helfritch Journal of Biological Engineering 2013, 7:8 Page 3 of 6 Figure 3 The cold spray deposition system. metal droplets, exits in the anode nozzle and is directed toward a surface, where the particles deposit. Arc spray The arc spray process shown in Figure 2 creates an arc between two metallic wires acting as consumable electrodes. A DC voltage is applied between the wires, and an arc discharge is created at the contact of the wires. The wire electrodes are melted by the electric arc and a compressed air jet disperses the molten droplets and propels them onto a surface. Cold spray The cold spray process shown in Figure 3 imparts supersonic velocities to metal particles by placing them in a heated nitrogen or helium gas stream that is expanded through a converging diverging nozzle. The powder feed is inserted at high pressure at the nozzle entrance. The particles, entrained within the gas, are directed towards a surface, where they are embedded on impact, forming a strong bond with the surface. The term cold spray has been used to describe this process due to the relatively low temperatures (100-500 C) of the expanded gas stream that exits the nozzle. Subsequent spray passes increase the structure thickness. The adhesion of the metal powder to the substrate, as well as the cohesion of the deposited material, is accomplished in the solid state. The relatively low porosity of the cold spray coating results from particle packing caused by high velocity impact. Another characteristic of high velocity impacts is the creation of grain dislocations and work hardening. The low oxide content of cold sprayed deposits occurs because the particle temperature remains low and thus inhibits oxidation. The spray techniques described each produce impacting metal particles in distinct temperature and velocity ranges. These temperatures and velocities create metal coatings with different characteristics with respect to the presence of oxides, porosity, grain dislocations, and hardness. Because of these metallurgic differences, it is reasonable to assume that the coatings will exhibit differences in antimicrobial efficiency. Table 1 gives the particle temperatures and impact velocities, as well as the porosity and oxide ranges of the resulting deposits. Test procedure These three surface coating techniques were used to produce copper-coated metal coupons. Approximately 1 mm thick coatings were applied to aluminum substrates. The coatings completely covered the metal substrates with an impervious seal. The copper powder feedstock used for the plasma and cold sprays is shown in Figure 4. Cross sections of the coupons produced by the three spray techniques are shown in Figures 5, 6 and 7. Differences in microstructure are clearly evident, suggesting that differences in biological activity may also occur. Evidence of particle melting is clear for the high-temperature plasma and wire arc processes. The incidence of large voids is seen in the wire arc process cross section. The coated coupons were inoculated with MRSA. The plated samples were then held at room temperature for two hours, after which survivors were resuspended and cultured. This procedure followed the EPA Protocol [17] Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer. The details of this procedure are given below [17-20]. Carrier surfaces and preparation The copper coupon surfaces were utilized as the test carriers and stainless steel squares were used as control Table 1 Typical spray gun operating parameters Spray/ Temperature C Velocity, m/s Porosity, % Oxides, % Property Plasma 2500-3500 100-300 1-10 1-3 Wire Arc 2500-3500 50-100 5-20 10-20 Cold Spray 100-500 600-1000 <1 <1

Champagne and Helfritch Journal of Biological Engineering 2013, 7:8 Page 4 of 6 Figure 4 Feedstock copper powder for plasma and cold spray. carriers. The carriers were dipped into ethanol, rinsed with deionized water, and allowed to air dry. The carriers were autoclaved prior to use in test. After sterilization, each carrier was placed into a Petri dish matted with two pieces of filter paper. Preparation of test organisms Ten (10) ml tubes of Synthetic Broth were inoculated from stock cultures and incubated for 24 hours at 36 C. Using a 4-mm inside diameter disposable sterile plastic transfer loop, at least three consecutive daily transfers of cultures were made in Synthetic Broth prior to use as test inoculum. Two loopfuls of culture were transferred to 10 ml broth medium and incubated for 48 hours. The culture was thoroughly mixed on a vortex mixer and allowed to settle. The upper two thirds of this suspension was used as the inoculum for testing. Figure 6 Cross sectional view of the wire arc sprayed copper deposit. Addition of organic soil load An organic soil load containing Triton X-100 (to aid in spreading of the inoculums) was added to the test culture. A 0.25 ml aliquot of fetal bovine serum and 0.05 ml aliquot of 1% Triton X-100 was added to 4.70 ml of culture to yield a 5% fetal bovine serum and 0.01% Triton X-100 soil load. Inoculation of carriers Each test and control carrier was inoculated at staggered intervals with 0.02 ml of 48 hour culture using a calibrated pipettor. The inoculum was spread to within 3 mm of the edges of the carrier. The lids of the Petri dishes were replaced and the carriers were held at room temperature (20 C) for 2 hours. The exposure period began immediately after inoculation. Figure 5 Cross sectional view of the plasma sprayed copper deposit. Figure 7 Cross sectional view of the cold sprayed copper deposit.

Champagne and Helfritch Journal of Biological Engineering 2013, 7:8 Page 5 of 6 Figure 8 Percent MRSA surviving after exposure to various copper deposits. Neutralization and subculture Following the 2 hour exposure, the carriers were transferred to jars containing 20 ml of Letheen Broth + 0.07% Lecithin + 0.5% Tween 80 at staggered intervals. Each neutralizer jar was sonicated for five minutes to suspend any survivors and rotated to mix. Serial dilutions (10 0 10-4 ) of the neutralized solution from each of the jars were prepared. One (1.0) ml aliquots of those dilutions were plated in duplicate using standard spread plate technique onto sheep blood agar plates (BAP). solid particles at high velocity (>600 m/s). Champagne, et al. [21] have shown that the high velocity impacts of cold sprayed particles lead to extreme work hardening and correspondingly high dislocation density within the deposit. For example, the Vickers Hardness values for plasma, wire arc, and cold spray deposited copper were 94, 105, and 141, respectively. Ion diffusion in metals is augmented by the presence of grain dislocations, known as pipe diffusion, and ionic diffusion occurs principally through these dislocations. The relationship between Incubation and observation The plates were incubated at 36 C for 44 hours prior to observation and enumeration. Following incubation, the plates were visually enumerated. Subcultures containing 30 300 colonies were used for calculations. Results and discussion The reduction of inoculated S. aureus was normalized by the results of the control exposure to a stainless steel surface. The results of these tests in terms of the percent of surviving S. aureus after two hours are shown in Figure 8. The result for cold spray was below minimal measurement thresholds and is thus reported as less than. The results show a greater than three order of magnitude difference in kill efficiency between the plasma and wire arc methods and the cold spray method of copper deposition. This large difference in anti-microbial effectiveness between copper spray deposition methods requires an examination of how the deposition mechanism affects the nature of the copper. The plasma and wire arc methods deposit molten particles at relatively low velocity (<200 m/s). The cold spray method deposits Figure 9 Hospital table coated with cold-sprayed copper.

Champagne and Helfritch Journal of Biological Engineering 2013, 7:8 Page 6 of 6 dislocation density and Vickers Hardness is [22] ρ H 2, and the relationship between diffusivity and displacement density is given by [23] D p ρ. Diffusivity in metals thus varies as the square of hardness and is therefore very sensitive to impact hardening by cold spray deposition. The diffusion of copper ions can therefore be significantly increased through the hardness increase produced by the cold spray process, which serves to enhance the flow of Cu 2+ ions needed for microbial destruction. Conclusions The effectiveness of copper and copper alloys as antimicrobial coatings on touch-surfaces has been well documented by many researchers [5-7,10,12-15]. Except for the copper content of alloys, the effects of the metallurgical properties of the copper coatings have not been investigated by these efforts. The significant anti-microbiologic differences between coatings produced by different spray techniques, as shown here, demonstrate the importance of the copper application technique and of the resulting deposition structure. The cold spray technique showed superior anti-microbial effectiveness caused by the high impact velocity imparted to the sprayed particles which results in high dislocation density and high ionic copper diffusivity. The cold spray process is a mature technology which is currently in use for a variety of applications requiring various metal coatings. The cold spray process can readily apply copper coatings onto touch surfaces. Figure 9 is an example of copper coating by cold spray. The hospital tray and the entire metal support structure of the hospital table have been coated with cold-sprayed pure copper. In addition to providing highly efficient antimicrobial surfaces, the cold spray technique is less likely to damage heat sensitive substrates than are high temperature thermal sprays. This work is a proof-of-concept effort, and additional, more statistically significant, work should be performed in order to justify commercialization. Competing interests The authors declare that they have no competing interests. Authors contributions VKC conceived and directed the test program. DJH interpreted the test results and justified the mechanism. Both authors read and approved the final manuscript. Acknowledgements The sanitizer efficacy testing conducted against Staphylococcus aureus and reported in this paper was carried out under contract by ATS Labs at Eagan MN. The experiments were performed by Amy Jeske and Becky Lien. Author details 1 U.S. Army Research Laboratory, Aberdeen Proving Ground, MD, USA. 2 Dynamic Science, Aberdeen, MD, USA. References 1. Page K, Wilson M, Parkin I: Antimicrobial surfaces and their potential in reducing the role of the inanimate environment in the incidence of hospital-acquired infections. J Mater Chem 2009, 19:3819 3831. 2. Aycicek H, Oguz U, Karci K: Comparison of results of ATP bioluminescence and traditional hygiene swabbing methods for the determination of surface cleanliness at a hospital kitchen. Int J Hyg Environ Health 2006, 209:203 206. 3. Bernard L, Kereveur A, Durand D, Gonot J, Goldstein F, Mainardi J, Acar J, Carlet J: Bacterial contamination of hospital physicians stethoscopes. Infect Control Hosp Epidemiol 1999, 20:626 628. 4. Rutala WA, Katz EB, Sherertz RJ, Sarubbi FA: Environmental-study of a methicillin-resistant staphylococcus -aureus epidemic in a burn unit. J Clin Microbiol 1983, 18:683 688. 5. White LF, Dancer SJ, Robertson C: A microbiological evaluation of hospital cleaning methods. Int J Environ Health Res 2007, 17:285 295. 6. Faúndez G, Troncoso M, Navarrete P, Figueroa G: Antimicrobial activity of copper surfaces against suspensions of Salmonella enterica and Campylobacter jejuni. BMC Microbiol 2004, 4:19. 7. Gounadaki S, Skandamis PN, Drosinos EH, Nychas GJ: Microbial ecology of food contact surfaces and products of small-scale facilities producing traditional sausages. Food Microbiol 2008, 25:313 323. 8. Jackson V, Blair IS, McDowell DA, Kennedy J, Bolton DJ: The incidence of significant foodborne pathogens in domestic refrigerators. Food Control 2007, 18:346 351. 9. Kaneko K, Hayashidani H, Takahashi K, Shiraki Y, Limawongpranee S, Ogawa M: Bacterial contamination in the environment of food factories processing ready-to-eat fresh vegetables. J Food Prot 1999, 62:800 804. 10. Noyce J, Michels H, Keevil C: Use of copper cast alloys to control Escherichia coli O157 cross-contamination during food processing. Appl Environ Microbiol 2006, 72:4239 4244. 11. Grass G, Rensing C, Solioz M: Metallic copper as an antimicrobial surface. Appl Environ Microbiol 2011, 76:1541 1547. 12. Michels H, Wilks S, Noyce J, Keevil C: Copper Alloys for Human Infectious Disease Control. Pittsburgh, PA: Proceedings of the Materials Science and Technology Conference; 2005. 13. Nie Y, Kalapos C, Nie X, Murphy M, Hussein R, Zhang J: Superhydrophilicity and antibacterial property of a Cu-dotted oxide coating surface. Ann Clin Microbiol Antimicrob 2010, 9:25. 14. Raffi M, Mehrwan S, Bhatti T, Akhter J, Hameed A, Yawar W, Masood Ul Hasan M: Investigations into the antibacterial behavior of copper nanoparticles against Escherichia coli. Ann Microbiol 2010, 60:75 80. 15. Santo CE, Lam EW, Elowsky CG, Quaranta D, Domaille DW, Chang CJ, Grass G: Bacterial killing by dry metallic copper surfaces. Appl Environ Microbiol 2011, 77:794 802. 16. EPA registers copper-containing alloy products. www.epa.gov/pesticides/ factsheets/copper-alloy-products.htm. 17. Test method for efficacy of copper alloy surfaces as a sanitizer. www.epa. gov/oppad001/pdf_files/test_method_copper_alloy_surfaces.pdf. 18. Lien B: Test Method for Determining the Efficacy of Antimicrobial Surfaces as Sanitizers. Eagan: ATS Labs Report A09966; 2010. 19. Jeske A: Custom Microbiology Evaluation of Coated Copper Surfaces. Eagan: ATS Labs; 2009 Report. 20. Jeske A: Custom Microbiology Evaluation of Cold Spray Copper Surfaces, ATS Labs Report. Eagan: ATS Labs; 2008. Report A06255. 21. Champagne V, Helfritch D, Trexler M: Some Material Characteristics of Cold-Sprayed Structures. Res Lett Mater Sci 2007, 2007:ID 27347. 22. Al-Rub R, Faruk NM: Dislocation-based model for predicting size-scale effects on the micro and nano indentation hardness of metallic materials. Int J Mater Struct Integrity 2010, 4:251 277. 23. Hart EW: On the role of dislocations in bulk diffusion. Acta Metall 1957, 5:597. doi:10.1186/1754-1611-7-8 Cite this article as: Champagne and Helfritch: A demonstration of the antimicrobial effectiveness of various copper surfaces. Journal of Biological Engineering 2013 7:8. Received: 24 January 2013 Accepted: 15 March 2013 Published: 27 March 2013