Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Similar documents
Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Tehnical Data Sheet Astro X-Series CE Pipe Wrap. UIC of product-type: XSPW CPR-JA5085 ETA-15/0619. ETAG 026-Part 1 ETAG 026-Part 2

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

ETA 17/0081 of 21/06/2017. European Technical Assessment. Technical Assessment Body issuing the ETA and designated according to Article 29 of the

Trade name EZ-Path Fire-Rated Pathway (Series 33 and Series 44+) Cable Penetration Seals

DECLARATION OF PERFORMANCE

European Technical Approval ETA-13/0262

European Technical Assessment ETA-17/0741 of 29/08/2017

Fire Stopping and Sealing Product: Penetration Seals

European Technical Assessment. ETA-11/0372 of Member of. General part

UL- E U C E R T I F I C A T E

UL- E U C E R T I F I C A T E

ORYX Grafite FR. Our specialists are always ready to provide you with technical advice and support. PRODUCT DESCRIPTION

Tehnical Data Sheet Astro HS FM Compound. UIC of product-type: HSFMC CPR-JA5013 ETA-14/0047. ETAG 026-Part 1 ETAG 026-Part 2

European Technical Assessment. ETA-15/0801 of Member of. General part

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

UL- E U C E R T I F I C A T E

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

DECLARATION OF PERFORMANCE

European Technical Assessment. ETA-11/0206 of Member of. General part. Technical Assessment Body issuing the

This European technical approval

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

DECLARATION OF PERFORMANCE

European Technical Assessment ETA-16/0952 of 06/01/2017

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

European Technical Assessment. ETA 07/0075 of General part

Technical Data Sheet. Hilti CFS-CU Firestop Cushion. European technical approval ETA N o 08/0213. Issue 04 / Hilti Firestop Cushion CFS-CU

European Technical Assessment. ETA-16/0320 of Member of. General part

DECLARATION OF PERFORMANCE

This European technical approval

European Technical Assessment ETA-09/0156 of 18/12/2015

DECLARATION OF PERFORMANCE

European Technical Approval No. ETA-12/0056

European Technical Assessment. ETA-17/0398 of Member of. General part

This European technical approval

European Technical Assessment. ETA-10/0291 of Member of. General part

European Technical Assessment ETA-12/0578 of 2014/04/01

ETA-14/0484 of 9 October European Technical Assessment. General Part. Deutsches Institut für Bautechnik

European Technical Assessment ETA-17/0346 of 07/06/2017

European Technical Assessment ETA-11/0518 of 19/08/2015

European Technical Assessment. ETA 17/0154 of 27/03/2017. ALSAN Flashing quadro. Liquid applied roof waterproofing kit on the basis of plyurethane

In der Stockwiese Bad Laasphe DEUTSCHLAND. Manufacturing plant EJOT Herstellwerk 1, 2, 3 und 4 manufacturing plant EJOT 1, 2, 3 und 4

European Technical Assessment ETA-10/0124 of 29/04/2016

European Technical Assessment. ETA-13/0099 of Member of. General part

DECLARATION OF PERFORMANCE

European Technical Assessment. ETA-13/0088 of 20/03/2018. Egzemplarz archiwalny. General Part. Instytut Techniki Budowlanej

(English language translation, the original version is in French language) SORMAT LYT. SORMAT OY Harjutie 5 FIN Rusko Finlande.

European Technical Assessment ETA-10/0067 of

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

European technical approval

Hilti Firestop Single Board Seal Hilti Firestop Single Board Seal. Hilti AG Feldkircherstrasse Schaan Liechtenstein

No: UK-WER _english. 1. Unique identification code of the product-type UK-WER _english

fermacell AESTUVER Mixed / Cable Penetration Seal S

fermacell AESTUVER Fire-protection board

European Technical Assessment. ETA-18/0083 of Member of. General part

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015

European Technical Assessment. ETA-18/0041 of Member of. General part

European Technical Assessment. ETA-15/0540 of Member of. General part

ETA-07/0291 of 30/06/2014. European Technical Assessment. Draft. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

Fire Barrier 3000 WT Intumescent Silicone Sealant

HENSOMASTIK. Mixed Penetration Seal EI 30 / EI 60. According to the European Technical Assessment ETA 15/0294

European Technical Assessment. ETA-11/0135 of Member of. General part

European Technical Approval ETA-13/0078

European Technical Assessment. ETA-12/0101 of Member of. General part

ETA-06/0076 of European Technical Assessment. Member of. General part. Technical Assessment Body issuing the

ETA-13/0584 of 24/09/2014. European Technical Assessment. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

Manufacturer Pre Cast Technology AB, Box 552, SE Kungälv, Sweden Manufacturing plant(s)

European Technical Assessment ETA 14/0075 of 14/04/2014

European Technical Assessment ETA 14/0077

Technical Data Sheet. Hilti Firestop Block Kit: Hilti firestop block CFS-BL Hilti firestop filler CFS-FIL Hilti firestop putty bandage CFS-P BA

U L - E U C E R T I F I C A T E

European Technical Assessment ETA-14/0392 of 04/12/2014

European technical approval

Fire Barrier CP25WB+ Sealant

European Technical Approval ETA 13/0334

European Technical Assessment ETA-14/0354 of

(English language translation, the original version is in French language) Sto-Polydal SP 15/09/ /04/2015

European Technical Approval ETA-10/0212 Revision 1

European Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the

European Technical Approval ETA-13/0982

European Technical Assessment ETA-14/0331

European Technical Approval ETA-13/0623

(English language translation, the original version is in French language) SPIT SAS route de Lyon F BOURG-LES-VALENCE France

European Technical Assessment ETA-10/0422 of 08/01/2016

ETA-07/0034 of 24/04/2017. European Technical Assessment. Member of. Designated according to Article 29 of Regulation (EU) No 305/2011.

English translation prepared by CSTB - Original version in French language

(English language translation, the original version is in French language) SOFRETHANE S3

DECLARATION OF PERFORMANCE. No EN

Transcription:

Member of www.eota.eu UL INTERNATIONAL (UK) LTD Wonersh House, Building C, The Guildway, Old Portsmouth Road, Guildford. GU3 1LR. United Kingdom. designated according to Article 29 of the Regulation (EU) No 305/2011 and member of EOTA (European Organisation for Technical Assessment, www.eota.eu) European Technical Assessment ETA 14/0266 of 16/07/2014 Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd Trade name of the construction product Product family to which the construction product belongs Sealfire FX400 CE Pipe Collar Fire Stopping and Sealing Product: Penetration Seals Manufacturer Würth Oy Hyvinkääntie 1 FI-11710 Riihimäki Finland Manufacturing plant(s) A/005 This European Technical Assessment contains This European Technical Assessment is issued in accordance with regulation (EU) No 305/2011, on the basis of 12 pages including 1 Annex which forms an integral part of this assessment. ETAG 026-2, edition 2011, used as European Assessment Document (EAD). Translations of this European Technical Assessment in other languages shall fully correspond to the original issued document and should be identified as such. Communication of this European Technical Assessment, including transmission by electronic means, shall be in full. However, partial reproduction may be made, with the written consent of the issuing Technical Assessment Body. Any partial reproduction has to be identified as such. ETA 14/0266 of 16/07/2014 page 1 of 9

Table of Contents I. SPECIFIC PARTS OF THE EUROPEAN TECHNICAL ASSESSMENT... 3 1 Technical description of the product... 3 2 Specification of the intended uses of the product in accordance with the applicable European Assessment Document (Hereinafter EAD): ETAG 026-2... 3 3 Performance of the product and references to the methods used for its assessment... 5 4 ASSESSMENT AND VERIFICATION OF CONSTANCY OF PERFORMANCE (HEREINAFTER AVCP) SYSTEM APPLIED, WITH REFERENCE TO ITS LEGAL BASE... 6 5 Technical details necessary for the implementation of the AVCP system, as provided for in the applicable EAD... 6 6 Issued on:... 7 ANNEX A Resistance to Fire Classification Sealfire FX400 CE Pipe Collar... 8 A.1 Flexible or rigid wall constructions with wall thickness of minimum 100 mm... 8 A.1.1 Penetration seals, in drywalls and concrete/masonry walls... 8 A.2 Rigid floor constructions with floor thickness of minimum 150 mm... 10 A.2.1 Penetration seals, in concrete floors... 10 A.3 Rigid floor constructions with floor thickness of minimum 150 mm... 12 A.3.1 Penetration seals, in concrete floors... 12 ETA 14/0266 of 16/07/2014 Page 2 of 12

I. SPECIFIC PARTS OF THE EUROPEAN TECHNICAL ASSESSMENT 1 Technical description of the product 1) Sealfire FX400 CE Pipe Collar is a pipe closure device used to form penetration seals where combustible pipes, cables and metal pipes with insulation penetrate walls and floors. 2) The Sealfire FX400 CE Pipe Collar is supplied with intumescent liner complete within metal steel shell, to be clamped around the service and screw fixed back to the supporting element. The Firebreak FX400 Pipe Collar may be supplied with powder coated steel shells incorporating a hinge and toggle latch, stainless steel half shells with slide together fixing and galvanized steel half shells with slide together fixing. 3) The applicant has submitted a written declaration that the product and/or constituents of the product contains no substances which have been classified as dangerous according to Directive 67/548/EEC and Regulation (EC) No. 1272/2008 and listed in the indicative list on dangerous substances of the EGDS taking into account the installation conditions of the construction product and the release scenarios resulting from there. In addition to the specific clauses relating to dangerous substances contained in this European Technical Assessment, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the Construction Products Regulation, these requirements need also to be complied with, when and where they apply. 4) The use catagory of Sealfire FX400 CE Pipe Collar in relation to BWR 4 (safety in use) is IA1, S/W3 2 Specification of the intended uses of the product in accordance with the applicable European Assessment Document (Hereinafter EAD): ETAG 026-2 Detailed information and data is given in Annex A. The intended use of system Sealfire FX400 CE Pipe Collar is to reinstate the fire resistance performance of flexible wall and rigid wall and floor constructions, where they are penetrated by services. 1) The specific elements of construction that the system Sealfire FX400 CE Pipe Collar may be used to provide a penetration seal in, are as follows: Flexible walls: Rigid walls: Rigid floors: The wall must have a minimum thickness of 100 mm and comprise steel studs lined on both faces with minimum 2 layers of 12.5 mm thick boards. The wall must have a minimum thickness of 100 mm and comprise concrete, aerated concrete or masonry, with a minimum density of 650 kg/m3. The floor must have a minimum thickness of 150 mm and comprise aerated concrete or concrete with a minimum density of 650 kg/m3. The supporting construction must be classified in accordance with EN 13501-2 for the required fire resistance period. 2) The system Sealfire FX400 CE Pipe Collar may be used to provide a penetration seal with specific supporting constructions and substrates (for details see Annex A). ETA 14/0266 of 16/07/2014 Page 3 of 12

3) The provisions made in this European Technical Assessment are based on an assumed working life of the Sealfire FX400 CE Pipe Collar of 10 years, provided that the conditions laid down in the manufacturers datasheet and instructions for the packaging/transport/storage/installation/ use/repair are met. The indications given on the working life cannot be interpreted as a guarantee given by the producer, but are to be regarded only as a means for choosing the right products in relation to the expected economically reasonable working life of the works. 4) Type Y 2 : intended for use at temperatures below 0 C, but with no exposure to rain nor UV. Includes lower use categories. ETA 14/0266 of 16/07/2014 Page 4 of 12

3 Performance of the product and references to the methods used for its assessment Product-type: Pipe Collar Intended use: Penetration Seal Basic requirement for construction work Basic Requirement BWR 1 Mechanical resistance and stability Performance - None Not relevant BWR 2 Safety in case of fire EN 13501-1 Reaction to fire Class F EN 13501-2 Resistance to fire Annex A BWR 3 Hygiene, health and environment EN 1026:2000 Air permeability (material property) No performance determined ETAG 026-2, Annex C Water permeability (material property) No performance determined Declaration of manufacturer Release of dangerous substances BWR 4 Safety in use Use categories: IA1, S/W3 Declaration of manufacturer EOTA TR 001:2003 Mechanical resistance and stability No performance determined EOTA TR 001:2003 Resistance to impact/movement No performance determined EOTA TR 001:2003 Adhesion No performance determined BWR 5 Protection against noise EN 10140-2/ EN ISO 717-1 Airborne sound insulation No performance determined BWR 6 Energy economy and heat retention EN 12664, EN 12667 or EN 12939 EN ISO 12572 EN 12086 Thermal properties Water vapour permeability General aspects relating to fitness for use No performance determined No performance determined EOTA TR 024:2009, clause 3.1.11 & 3.1.12 Durability and serviceability Y 2 BWR 7 Sustainable use of natural resources - - No performance determined ETA 14/0266 of 16/07/2014 Page 5 of 12

4 ASSESSMENT AND VERIFICATION OF CONSTANCY OF PERFORMANCE (HEREINAFTER AVCP) SYSTEM APPLIED, WITH REFERENCE TO ITS LEGAL BASE According to the decision 1999/454/EC Commission Decision of date 22nd June 1999 on on the procedure for attesting the conformity of construction products pursuant to Article 20(2) of Council Directive 89/106/EEC as regards fire stopping, fire sealing and fire protective products, published in the Official Journal of the European Union (OJEU) L178/52 of 14/07/1999, see http://eur-lex.europa.eu/joindex.do) of the European Commission 1, as amended, the system(s) of assessment and verification of constancy of performance (see Annex V to Regulation (EU) No 305/2011) given in the following table(s) applies (apply). Product(s) Intended use(s) Level(s) or class(es) System(s) Fire stopping and Fire Sealing Products For fire compartmentation and/or fire protection or fire performance Any 1 5 Technical details necessary for the implementation of the AVCP system, as provided for in the applicable EAD Tasks of the manufacturer: Factory production control The manufacturer shall exercise permanent internal control of production. All the elements, requirements and provisions adopted by the manufacturer shall be documented in a systematic manner in the form of written policies and procedures, including records of results performed. This production control system shall ensure that the product is in conformity with this European Technical Assessment. The manufacturer may only use initial / raw / constituent materials stated in the technical documentation of this European Technical Assessment. The factory production control shall be in accordance with the Control Plan of 23 rd January 2014 relating to the European Technical Assessment ETA 14/0266 issued on 16/07/14 which is part of the technical documentation of this European Technical Assessment. The "Control Plan" is laid down in the context of the factory production control system operated by the manufacturer and deposited at UL International (UK) Ltd. The results of factory production control shall be recorded and evaluated in accordance with the provisions of the Control Plan. 1 Official Journal of the European Communities L178/52 of 14/7/1999 ETA 14/0266 of 16/07/2014 Page 6 of 12

Other tasks of the manufacturer Additional information The manufacturer shall provide a technical data sheet and an installation instruction with the following minimum information: (a) Technical data sheet: Field of application: Building elements for which the penetration seal is suitable, type and properties of the building elements like minimum thickness, density, and - in case of lightweight constructions the construction requirements. Limits in size, minimum thickness etc. of the penetration seal Construction of the penetration seal including the necessary components and additional products (e.g. backfilling material) with clear indication whether they are generic or specific. (b) Installation instruction: Steps to be followed Procedure in case of retrofitting Stipulations on maintenance, repair and replacement 6 Issued on: 16 th July 2014 Report by: Reviewed by: C. Johnson C. W. Miles Staff Engineer Business Manager Europe & Latin America Building and Life Safety Technologies Building and Life Safety Technologies For and on behalf of UL International (UK) Ltd. ETA 14/0266 of 16/07/2014 Page 7 of 12

ANNEX A Resistance to Fire Classification Sealfire FX400 CE Pipe Collar A.1 Flexible or rigid wall constructions with wall thickness of minimum 100 mm A.1.1 Penetration seals, in drywalls and concrete/masonry walls Penetration Seal: Insulated metal and combustible pipes and telecoms cables fitted with Sealfire FX400 CE Pipe Collar to both sides of the wall. Construction details: Sealant ETA 14/0266 of 16/07/2014 Page 8 of 12

A.1.1.1 Services Collar Inlay Classification PVC-U pipe according to EN 1329-1, EN 1452-2 and EN 1453-1 Diameter 32 mm, wall thickness 3-3.2 mm Diameter 38 mm, wall thickness 3-3.2 mm Diameter 40 mm, wall thickness 3-3.2 mm Diameter 42.2 mm, wall thickness 3.2 mm Diameter 46 mm, wall thickness 3.2 mm 50 x 4 mm Diameter 48.3 mm, wall thickness 3.2 mm Diameter 50 mm, wall thickness 3.2 mm Diameter 55 mm, wall thickness 3.2 mm Diameter 82 mm, wall thickness 3.2 mm Diameter 110 mm, wall thickness 6.6 mm 50 x 8 mm EI 120 U/U, EI 120 C/U, EI 120 U/C, EI 120 C/C Diameter 160 mm, wall thickness 9.5 mm 60 x 12 mm Diameter 160 mm, wall thickness 3.2 mm 60 x 18 mm Diameter 200 mm, wall thickness 3.9 mm 125 x 20 mm PE pipe according to EN 1519-1, EN 12201-2 and EN 12FX 4006-1, ABS pipe according to EN 1455-1 and SAN+PVC pipe according to EN 1565-1 Diameter 32 mm, wall thickness 3.7-4.6 mm 50 x 4 mm Diameter 38 mm, wall thickness 3.7-4.6 mm Diameter 40 mm, wall thickness 3.7-4.6 mm Diameter 42.2 mm, wall thickness 4.6 mm EI 120 U/U, EI 120 C/U, EI 120 U/C, EI 120 C/C Diameter 46 mm, wall thickness 4.6 mm Diameter 48.3 mm, wall thickness 4.6 mm Diameter 50 mm, wall thickness 4.6 mm Diameter 75 mm, wall thickness 6.8 mm 50 x 6 mm EI 60 U/U, EI 60 C/U, EI 60 U/C, EI 60 C/C Diameter 75 mm, wall thickness 5.1 mm 50 x 8 mm Diameter 90 mm, wall thickness 5.1 mm 50 x 8 mm EI 120 U/U, EI 120 C/U, EI 120 U/C, EI 120 C/C Diameter 110 mm, wall thickness 6.2 50 x 8 mm EI 120 U/U, EI 120 C/U, EI 120 U/C, EI 120 C/C Diameter 110 mm, wall thickness 10 mm 50 x 8 mm EI 60 U/U, EI 60 C/U, EI 60 U/C, EI 60 C/C Diameter 160 mm, wall thickness 7 mm 60 x 17 mm EI 120 U/U, EI 120 C/U, EI 120 U/C, EI 120 C/C PVC-U pipe according to EN 1329-1, EN 1452-2 and EN 1453-1 with 19 mm Armaflex insulation Diameter 55 mm, wall thickness 2 mm 50 x 8 mm E 120 U/U, E 120 C/U, E 120 U/C, E 120 C/C EI 90 U/U, EI 90 C/U, EI 90 U/C, EI 90 C/C Copper with 19 mm thick Armaflex insulation Diameter 54 mm, wall thickness 0.8-14.2 mm 50 x 8 mm E 120 U/U, E 120 C/U, E 120 U/C, E 120 C/C EI 60 U/U, EI 60 C/U, EI 60 U/C, EI 60 C/C Telecoms cables up to 21 mm diameter in bundles up to 100 mm diameter^ Up to 21 mm diameter in bundles up to 100 mm diameter^ Up to 21 mm diameter in bundles up to 100 mm diameter^ wrapped with 300 mm long Insuwrap material 50 x 8 mm E 120, EI 90 EI 120 ETA 14/0266 of 16/07/2014 Page 9 of 12

A.2 Rigid floor constructions with floor thickness of minimum 150 mm A.2.1 Penetration seals, in concrete floors Penetration Seal: Combustible pipes fitted with Sealfire FX400 CE Pipe Collar to the soffit of the floor. Construction details: ETA 14/0266 of 16/07/2014 Page 10 of 12

A.2.1.1 Services Collar Inlay Classification PVC-U pipe according to EN 1329-1, EN 1452-2 and EN 1453-1 Diameter 32 mm, wall thickness 3 mm Diameter 38 mm, wall thickness 3 mm Diameter 40 mm, wall thickness 3 mm Diameter 42.2 mm, wall thickness 2 mm Diameter 46 mm, wall thickness 2 mm 50 x 4 mm EI 240 U/U, EI 240 C/U, EI 240 U/C, EI 240 C/C Diameter 48.3 mm, wall thickness 2 mm Diameter 50 mm, wall thickness 2 mm Diameter 55 mm, wall thickness 2 mm Diameter 82 mm, wall thickness 3.2 mm 50 x 6 mm EI 180 U/U, EI 180 C/U, EI 180 U/C, EI 180 C/C Diameter 110 mm, wall thickness 6.6 mm 50 x 8 mm Diameter 160 mm, wall thickness 9.5 mm 60 x 18 mm Diameter 200 mm, wall thickness 3.9 mm 125 x 20 mm PE pipe according to EN 1519-1, EN 12201-2 and EN 12FX 4006-1, ABS pipe according to EN 1455-1 and SAN+PVC pipe according to EN 1565-1 Diameter 32 mm, wall thickness 3.7 mm Diameter 38 mm, wall thickness 3.7 mm 50 x 4 mm EI 180 U/U, EI 180 C/U, EI 180 U/C, EI 180 C/C Diameter 40 mm, wall thickness 3.7 mm Diameter 75 mm, wall thickness 8.2 mm Diameter 110 mm, wall thickness 8.2 mm 50 x 8 mm EI 240 U/U, EI 240 C/U, EI 240 U/C, EI 240 C/C Diameter 160 mm, wall thickness 6.2 mm 60 x 18 mm EI 180 U/U, EI 180 C/U, EI 180 U/C, EI 180 C/C ETA 14/0266 of 16/07/2014 Page 11 of 12

A.3 Rigid floor constructions with floor thickness of minimum 150 mm A.3.1 Penetration seals, in concrete floors Penetration Seal: Combustible pipes fitted with Sealfire FX400 CE Pipe Collar to the recessed/cast in, within the soffit of the floor. Construction details: A.3.1.1 Services Collar Inlay Classification PVC-U pipe according to EN 1329-1, EN 1452-2 and EN 1453-1 Diameter 110 mm, wall thickness 3.2 mm 50 x 8 mm EI 90 U/U, EI 90 C/U, EI 90 U/C, EI 90 C/C Diameter 200 mm, wall thickness 3.9 mm 125 x 20 mm EI 240 U/U, EI 240 C/U, EI 240 U/C, EI 240 C/C ETA 14/0266 of 16/07/2014 Page 12 of 12