SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

Similar documents
SINTEF Building and Infrastructure confirms that. Hunton wall

SINTEF Building and Infrastructure confirms that. Kriaute Building System

SINTEF Building and Infrastructure confirms that. Protan Vacuum Roofing System

SINTEF Building and Infrastructure confirms that. Protan G, GG og GT roofing and waterproofing membranes

SINTEF Building and Infrastructure confirms that. Hunton Undertak / Hunton Sarket

SINTEF Building and Infrastructure confirms that. Guardian Fastening System

SINTEF Building and Infrastructure confirms that. Unihouse timber frame building elements

ASSEMBLY INSTRUCTIONS silencio THERMO 24 / 36 TG 2330

SINTEF Building and Infrastructure confirms that. HRC 700 cast-in connection system

NBI Technical Approval

Building elements. Guideline for SINTEF Technical Approval

Metal Web Floor System

SINTEF confirms that. Milletech Fastening System

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

LEWIS Dovetailed sheeting. Dovetailed Sheeting

Please Note: PhoneStar was previously branded as Phonewell

FERMACELL DRY FLOORING ELEMENTS: IMPROVED LIVING CONDITIONS THROUGH BETTER ACOUSTIC AND THERMAL INSULATION. Dry Lining

Wooden suspended floors

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

DOCUMENTATION FIRE - SOUND - U-VALUE B

ROCKWOOL FLEXI Insulation Application Guide

ROCKFLOOR. Thermal and acoustic stone wool insulation for ground and separating floors

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

SOLUTIONS FOR TIMBER STRUCTURES ACOUSTIC INSULATION

Wood Build Norway. New opportunities with web joist floor constructions. Contribution from SINTEF Building & Infrastructure. Anders Homb June 2013

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

On load-bearing floors with LK Slotted Board EPS 16

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

Roth Compact system. German quality since Installation 1/6

Polyfoam Floorboard For thermal insulation of floors

June Non - Residential New Build Partition walls

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

June Non - Residential Refurbishment Separating floors

Exterior Wall Solutions Building Shell

* lion (EU) No 305/2011 * * sation fortechnical * fermacell flooring systems. Fermacell GmbH Dosseldorfer Landstra~e Duisburg DEUTSCH LAND

Suspended timber upper floors

Sopro FDP 558 tile insulation board

SINTEF Building and Infrastructure confirms that. Moelven Modules

SINTEF Building and Infrastructure confirms that. Protan BlueProof Roofing System

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

June Residential Refurbishment Separating floors

April Section 4.3. Separating Floors

ETAG 016 SELF-SUPPORTING COMPOSITE LIGHTWEIGHT PANELS PART 4:

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Fire Barrier 3000 WT Intumescent Silicone Sealant

September Reflex Bearers

Selecting floors and ceilings

Masonite Beams Technical Guide for Floor Applications

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Jabfloor High Performance (HP) 70 and 100

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

9 Revision B

9/24/2015. Aalto! / ENG + ARC. Asuinrakennusten rakenneratkaisut. Requirements : Sound insulation requirements : Thermal insulation requirements :

PlyLok. Product Guide PIR and Plywood Laminate Insulation for Warm Flat Roofs.

Voie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) Operating vacuum pressure: - 500Pa

Member Design - Timber Floor XX 20/08/2015 EC5 Ref Timber Material Properties

SOUND INSULATION SLAB A family of fire resilient stone wool insulation products optimised for soundproofing

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Masonite Beams Technical Guide for Floor Applications

Sound insulation of Swedish Wooden floors Delphine Bard

Part E robustdetails. robustdetails. September 2015 Update Pack. Dear Colleague,

UL- E U C E R T I F I C A T E

Specialists in Acoustic Flooring and House to Flat Conversions

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

September Saddle Flooring Systems

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

LEWIS Dovetailed sheeting. Dovetailed Sheeting

Prediction of the acoustic performance of floor coverings on lightweight floors

CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance

Jabfloor 70, 100, 150, 200, 250

Multi-layer Insulation Blanket for Floors

HIGH PERFORMANCE PIR INSULATION

Timber Separating Walls 3.3.3

NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. Date of update May 30, 2018 Valid until May 29, 2023 HYBRIS

Construction Catalogue Timber construction goes into a lot of detail. Just like this catalogue.

FireX Fire Stopping Mastic FM

URSA ACOUSTIC ROLL URSA GLASSWOOL.

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

June Residential Refurbishment Exposed soffit floors

Hybrid cross-laminated timber floors. Comparison of measurements and calculations

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

fermacell AESTUVER Fire-protection board

SoundPro CDM-ISO-LAT. Acoustic solution for floating isolated floors

Part E robustdetails. robustdetails. January 2018 Update Pack

Introduction. Contents

CORK ROLLS WITH MICROBAN ANTIBACTERIAL PROTECTION TECHNICAL SPECIFICATION version: date: subject to errors or modifications

- Oversize panels to be used at perimeters as necessary in order to maintain minimum cut panel size.

CAN THE IMPACT SOUND IMPROVEMENT OF FLOOR COVERINGS BE MEASURED ON A WOODEN MOCK UP INSTEAD OF A TIMBER JOIST FLOOR?

R-Matte Plus-3: Insulation for the Building Envelope

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

WP6 Case studies. Pic. 1 Apartment houses in Chýně

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

GypLyner UNIVERSAL Concealed grid ceiling lining system

DECLARATION OF PERFORMANCE

Transcription:

SINTEF Certification No. 2330 Issued t: 18.02.2002 Revised: 17.06.2013 Valid until: 01.07.2018 Page: 1 of 5 SINTEF Building and Infrastructure confirms that Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo meets the provisions regarding product documentation given in Norwegian building regulations, with properties, fields of application and conditions as stated in this document 1. Holder of the approval Hunton Fiber AS P.O.Box 633 NO-2810 Gjøvik, Norway www.hunton.no 2. Manufacturer Hunton Fiber AS, NO-2810 Gjøvik, Norway 3. Product description This approval regards the use of Hunton Silencio 36 and Hunton Silencio Thermo as supporting layer and damping material in separating floor constructions. Fig. 1 Use of Hunton Silencio 36 under parquet flooring Hunton Silencio 36 is wood fibre softboards with a thickness of 36 mm, made of three 12 mm sheets glued together with water glass adhesive. The boards have rebated edges or tongue and groove on all four sides. Board density is approximately 250 kg/m 3, corresponding to a sheet weight of approximately 9 kg/m 2. Hunton Silencio Thermo is the same product as Hunton Silencio 36, but is supplied with slotted grooves for pipes combined with heat distribution plates of aluminium for waterborne floor heating. The standard board format is 600 mm x 1800 mm. The boards have the following tolerances in compliance with NS-EN 324-1: Thickness: ± 0.5 mm Length/width: ± 2 mm / ± 1 mm Perpendicular alignment: ± 1.5 mm per board width Hunton Silencio Thermo is supplied as standard elements, bend elements and distribution elements, with grooves for pipes with 17/16 mm diameter spaced c/c 200 mm or 300 mm, and for pipes with 20 mm diameter spaced c/c 300 mm. Fig.2. Use of Hunton Silencio Thermo with pipes for waterborne heating under parquet flooring 4. Fields of application Hunton Silencio is used as a damping layer under parquet or building board subfloors in floor constructions to reduce the impact level, and to increase the airborne insulation for rooms below. See fig 1 and 2. The use is restricted to floors with design loads in category A in compliance with NS-EN 1991-1-1/Eurokode 1, i.e. evenly distributed vertical load up to 2.0 kn/m 2 and recommended, vertical concentrated load up to 2 kn. Hunton Silencio may also be used under wooden floors fastened with screws. The boards are then combined with wooden laths in the joints as shown in fig. 3. SINTEF is the Norwegian member of European Organisation for Technical Approvals, EOTA, and European Union of Agrément, UEAtc Reference: Appr. 102000843-2 Contr. 102000843-1 Subject: Floor boards Head Office: SINTEF Building and Infrastructure P.O.Box 124 Blindern NO 0314 Oslo Tel. + 47 22 96 55 55 Fax + 47 22 69 94 38 Copyright SINTEF Byggforsk e-mail: byggforsk@sintef.no www.sintef.no/byggforsk Trondheim: SINTEF Building and Infrastructure 7465 Trondheim Tel. +47 73 59 30 00/33 90 Fax +47 73 59 33 50/80

SINTEF Technical Approval - No. 2330 Page 2 av 5 Fig. 3 Use of wooden lath in the joints of Hunton Silencio. Floor boards of solid wood can be attached to the laths with screws. The wooden lath is designed so that attaching the flooring does not impair the insulation. 5. Properties Load-carrying capacity The boards are sufficiently strong and rigid for the intended use as specified in clause 4. 8 (laboratory measurements) or NS-EN ISO 140-7 / NS- EN ISO 16283-2 (field measurements) including evaluation according to NS-EN ISO 717-2 / NS-EN ISO 16717-2. The expected, weighted improvement of the airborne insulation are in compliance with NS-EN ISO 10140-2 (laboratory measurements) or NS-EN ISO 140-4 / NS-EN ISO 16283-1 (field measurements) including evaluation according to NS-EN ISO 717-1 / NS- EN ISO 16717-1. Table 2 states the expected, weighted, apparent reduction index, R w and the expected, weighted, normalized impact level, L n,w for complete floor constructions in finished buildings with Hunton Silencio 36 or Hunton Silencio Thermo (example in fig. 4). The values are valid for heavy-weight floor constructions with normally good flanking transmission properties. Properties related to fire The boards are classified as E og E fl in compliance with NS-EN 13986 and NS-EN 13501-1. The boards are classified as combustible in compliance with NS 3919. Sound insulation, dynamic stiffness The dynamic stiffness for Hunton Silencio 36 is 8 MN/m 3 measured according to NS-ISO 9052-1 (EN 29052-1). Sound insulation, heavy-weight floor decks Table 1 states the expected weighted reduction of impact level (weighted improvement of impact insulation), ΔL n,w og expected weighted improvement of the airborne insulation, Δ R w by use of 13-15 mm laminated parquet on 36 mm Hunton Silencio on heavy floor decks. Table 1 Expected range of variation of impact level improvement and airborne insulation improvement for various types of flooring on Hunton Silencio on heavy floor decks. Top floor construction over floor deck 13-15 mm laminated parquet on Hunton Silencio 36 - Massive concrete floors - Concrete hollow core decks on Hunton Silencio - Massive concrete floors - Concrete hollow core decks Impact level improvement L n,w, db 22-24 26-30 23-25 24-32 Improvement of airborne insulation R w, db 3-5 3-5 The weighted reduction of impact level are in compliance with NS-EN ISO 10140-3/ NS-EN ISO 140- Fig. 4 Example of a heavy weight floor construction with Silencio Hunton. Table 2 Expected insulation characteristics of heavy weight floors with Hunton Silencio measured in finished buildings. Construction Weighted apparant reduction index, R w, db Weighted, normalized impact level, L n,w, db Hunton Silencio 36 1), 10 mm filler levelling, 55 53 200 mm concrete hollow core deck Hunton Silencio 36 1), 10 mm filler levelling, 265 mm concrete hollow core deck or 200 mm massive concrete deck 56 52 From experience the impact properties are 1-2 db better with Hunton Silencio Thermo 1) The weighted, apparent reduction index, R w are in compliance with NS-EN ISO 140-4 / NS-EN ISO 16283-1 including evaluation according to NS-EN ISO 717-1 / NS- EN ISO 16717-1. The weighted, normalized impact level, L n,w are in compliance with NS-EN ISO 140-7 / NS-EN ISO 16283-2 including evaluation according to NS-EN ISO 717-2 / NS-EN ISO 16717-2.

SINTEF Technical Approval - No. 2330 Page 3 av 5 Sound insulation, light-weight floors Table 3 states the expected, weighted, apparent reduction index, R w and the expected, weighted, normalized impact level, L n,w for complete floor constructions in finished buildings with Hunton Silencio 36 or Hunton Silencio Thermo on timber floor constructions with minimum 223 mm high joists, (see fig. 5-7). As the figures show, it is normally necessary to use an additional board under the parquet layer to obtain the impact level given in table 3. The insulation values vary with the degree of flanking transmissiom and are given for floors supported on respectivelyheavy-weight and light-weight load bearing walls. Table 3 Expected insulation characteristics of timber floor constructuions with Hunton Silencio, measured in finished buildings. Floor construction 1) Weighted apparant reduction index, R w, db Weighted, normalized impact level, L n,w, db On supporting walls of masonry or concrete 57 51 On supporting walls of timber construction with two layers of 13 mm plasterboard or similar on each side. 56 53 1) Floor construction as shown in fig. 5 ( 13-15 mm laminated parquet, 13 mm plasterboard, Hunton Silencio 36/Thermo, 22 mm chipboard, joists with minimum 223 mm height, 150 mm mineral wool, ceiling of 2 x 13 mm plasterboards suspended in elastic brackets) Fig. 6 Connection detail between external timber wall and timber floor construction. The top floor layers have a gap towards the wall. The gap may be filled with an elastic sealant. At need for internal support of the floor joists, we recommend use of hidden steel girder integrated in the floor construction so that the ceiling boards are continueously passing, see fig. 7. Use of exposed girder can not be used between different dwellings if the insulation requirements shall be fulfilled. Fig. 5 Example of timber floor construction with Hunton Silencio. Fig. 6 shows construction detail for connection between timber floor construction and external timber wall. Fig. 7 Support on hidden steel girder Support on internal load bearing wall may reduce the insulation values. If it is to be used, the dimension of the sill and studs must at least be 98 mm. In addition the cavity must be filled with mineral wool and the wall must have two layers of low radiation boards of 13 mm standard plaster board lining or similar on each side, see fig. 8.

SINTEF Technical Approval - No. 2330 Page 4 av 5 ± 2 mm over a measurement length of 2 m for decks and subfloors. The requirement is stricter than the recommended normal class in NS 3420-L and NS 3420-Q. Flooring material Laminated parquet laid directly on the boards must have a minimum thickness of 14 mm. Min. 15 mm boards for load distribution, e.g. chipboard with tongue and groove, shall be placed between Hunton Silencio and thin floor coverings, carpets and thin laminated flooring. Alternatively, 13 mm floor plasterboard can be used under thin laminate flooring, which is particularly relevant in combination with Silencio Thermo and floor heating systems. Fig. 8 Alternative support on insulated, load bearing internal wall with two layers of low radiation 13 mm standard plaster board lining or similar on each side. Thermal insulation The thermal conductivity for Hunton Silencio is λ d = 0,05 W/(m K), and the thermal resistance is R = 0.7 m²k/w. 6. Environmental aspects Substances hazardous to health and environment The product contains no hazardous substances with priority in quantities that pose any increased risk for human health and environment. Chemicals with priority include CMR, PBT or vpvb substances. Effect on indoor environment The product is not regarded as emitting any particles, gases or radiation that have a perceptible impact on the indoor climate, or to have any significant impact on health. Waste treatment/recycling The product shall be sorted as wood and metal materials on the building/demolition site. The product shall be delivered to an authorized waste treatment plant for energy and material recovery. Environmental declaration No environmental declaration (EPD) has been worked out for the product. 7. Special conditions for use and installation Design considerations The substrate should have evenness according to tolerance class PA as specified in Building Research Design Sheet No. 520.008 when using a floating parquet floor. This corresponds to a maximum surface deviation of Supporting conditions for the floor construction The characteristic insulation values stated in table 3 are valid as long as both external walls and internal load bearing walls have two layers of internal boards, see fig. 6 and 7. If the load bearing beam is replaced by a internal load bearing wall the wall dimension, insultation and number for boards be in accordance with the principle given in fig. 8. Installation The boards must be conditioned at the building site before installation, and the relative humidity of the air must not exceed 60 % during installation. The boards shall be placed staggered, with at least 200 mm side displacement. Pieces less than 150 mm should be avoided. There should be at least 5 mm clearance to walls, floor openings etc. A damp proof membrane of 0.2 mm polyethylene sheet under the boards shall be used when installation is made on concrete or light weight concrete decks. A wool felt should be placed on Hunton Silencio Thermo between the heat distribution plates and the top floor. Transport and storage The boards must be protected against precipitation during transport and storage. 8. Factory production control Hunton Silencio is subject to supervisory factory production and product control according to contract between SINTEF Building and Infrastructure and Hunton Fiber AS concerning Technical Approval. The floor construction on site must be controlled in each building project as a part of the ordinary building control. 9. Basis for the approval The approval is primarily based on verification of characteristics documented in the following reports: Norwegian Building Research Institute, report O 3952-46 dated 15.03.99. Measurement of thermal conductivity on wood fibre boards

SINTEF Technical Approval - No. 2330 Page 5 av 5 Norwegian Building Research Institute, report O 7978 dated 16.04.97. Measurement of dynamic stiffness Norwegian Building Research Institute, report N 7866 dated 17.09.99 and provisional report 08.02.01 on strength and stiffness of parquet and laminated floors on elastic foundation. SP Technical Research Institute of Sweden. Emission measurement Hunton Silencio 36. Report 3F 00 2441 av 05.03.2013. Emisjonsmåling.. In addition, the approval is based upon several assignment reports from the Norwegian Building Research Institute for Hunton Fiber AS et. al. concerning insulation measurements of floors with Hunton Silencio 36 and Hunton Silencio Thermo. 10. Marking All boards shall be labelled with the manufacturer s product designation and date of production. The approval mark for SINTEF Technical Approval No. 2330 may also be used. TG 2330 Approval mark 11. Liability The holder/manufacturer has sole product responsibility according to existing law. Claims resulting from the use of the product cannot be brought against SINTEF beyond the provisions of Norwegian Standard NS 8402 12. Technical management Project manager for this approval is Sigurd Hveem, SINTEF Building and Infrastructure, Oslo. for SINTEF Building and Infrastructure Marius Kvalvik Approval Manager