STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

Similar documents
IMAGE II. Panel Information. Detail Conditions. Flashing Profiles. Accessory Profiles. Testing Information. Design/Installation Considerations PIM-1

TABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles

CLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations

Detail Conditions. Panel Information. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations PEF-1

VERTICAL SEAM TABLE OF CONTENTS

Prior to ordering and installing materials, all dimensions should be verified by field measurements.

PBR & PBU PANELS. Technical/Installation Information

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

Stile. Spanish Tile Installation Guide

SEAM-LOC 24. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles

5V Crimp DESIGN/INSTALLATION INFORMATION

PBR & PBU PANELS. Technical/Installation Information

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

SHURLOC 150 STANDARD DETAILS

EVERSEAM 20 APPLICATION GUIDE

TRIAD CORRUGATED METAL, INC.

PBR & PBU Panels. Technical/Installation Information

SSL-175. Specifications

DL-200. Specifications

TYPICAL ROOF CONDITION LAYOUT

SECTION METAL ROOF AND SOFFIT PANELS

Western States 7/8 Corrugated

IMPORTANT INFORMATION

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.

ML200 Panel Technical Data Guide

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.

Roofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions

1.5 mechanical lock ml 150

T-Armor Install Guide

w w w. s a q u l i t y m e ta l s. c o m

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.

RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE

Table of Contents. 3. Exposed Fastener Panels

CONTOUR CORRUGATED PANEL

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

TABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB

TRIAD CORRUGATED METAL, INC.

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Tile

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Central Snap. Condition Details C SNAPDETAILS

1.5 mechanical lock ml 150

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

1.5 snap lock sl 150

2120 SW Poma Drive; Palm City, Florida Phone Fax

ENERGY STAR PARTNER. PBR & R Panel

COMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER

Central Seam Plus. Central-Loc

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Architectural Roof and Wall Products Guide Specifications

ML-150. w w w. s a q u l i t y m e ta l s. c o m. san antonio branch 210 W. Peden San Antonio TX P. (210) F.

SL-16. Design/Installation Information

Architectural Roof and Wall Products Guide Specifications

Classic Rib Roofing Panels DETAIL MANUAL

a division of NCI Standing Seam Roof Systems

2120 SW Poma Drive; Palm City, Florida Phone Fax

Black s Metals Installation Guide

UNA-CLAD Metal Roof Systems Code Approval Guide

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten

Residential Pricing Guide

SHEET METAL ROOF TEST REPORT

SECTION METAL ROOF PANELS

w w w. s a q u l i t y m e ta l s. c o m

INSTALLATION GUIDE.

Architectural Wall Products Guide Specifications

238T Aluminum Standing Seam Metal Roof System (SSMRS)

3' COMMERCIAL RIB PREFORMED METAL SIDING

SL175 Panel Technical Data Guide

Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood

Classic and NB Tile Counter Batten and Batten

Trusted Tested Tough Kalaeloa Blvd, Kapolei, Hawaii Phone (808) Fax (808) Neighbor Islands (800)

BARREL VAULT Tile Counter Batten and Batten Installation Guide

Architectural Roof and Wall Products Guide Specifications

ALLMET CONTINENTAL INSTALLATION GUIDE

5V CRIMP. Technical/Installation Information

Covering Design Regions

CS-100 Guide Specifications

Sheet Metal Flashing and Trim

HORIZON-LOC EXPOSED FASTENER TRIMS

Residential, 26 Ga. Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION

T-Rib Roofing System

S BI COM P ON E NT CA T ALOG

Table of Contents. 3. Standing Seam Panels

Light-Metal Roof Edge, Raised

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

UNA-CLAD Metal Roof Systems

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

1 1/2" SSR. FABRAL The pursuit of excellence since 1967

KS SERIES - VERTICAL INSTALLATION

FABRAL The pursuit of excellence since 1967

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SECTION STEEL BUILDING SYSTEMS

Recla Metals RCM INSTALLATION GUIDELINES

PRE-ENGINEERED METAL BUILDING SYSTEM

Transcription:

Table of ontents Product Page No. Product Page No. Panel Information Profile...PST-2 Panel Overview...PST-2 Flashing Profiles Eave...PST- Extended Eave...PST- leat...pst- Stile Starter...PST- Box Gutter...PST- Box Gutter End...PST- Universal Gutter/Downspout Strap...PST- 4" x /2" Downspout...PST- 4" x /2" 95 Elbow...PST- Downspout Bracket...PST- Stile Valley...PST- Valley over...pst- Formed Rake...PST- Rake...PST- Rake Starter...PST- Pitch Break...PST-4 ounter Flashing...PST-4 Reglet Flashing...PST-4 Ridge/Hip over...pst-4 Formed Ridge...PST-4 Vent Drip...PST-4 Stile -losure...pst-4 Junction Sheet...PST-4 Stile Ridge Drip...PST-4 Design/Installation onsiderations Fastener Installation Technique...PST-8 ondition of Substructure...PST-8 Ventilation...PST-9 Panel Applications...PST-9 Detail onditions Eave Detail...PST-0 Extended Eave Detail...PST-0 Gutter Detail...PST- Valley Detail...PST- Slope hange Detail...PST-2 Endlap Detail...PST-2 Rake Detail...PST- Formed Rake Detail...PST- Rake Parapet Siding Detail...PST-4 Endwall with ounter Detail...PST-4 Endwall with Reglet Detail...PST-5 Junction Sheet Detail...PST-5 Ridge/Hip Detail...PST-6 Formed Ridge/Hip Detail...PST-6 Formed Vented Ridge Detail...PST-7 Roof Vent Detail...PST-7 Notes Notes...PST-8 Accessory Profiles Stile Inside/Outside losure...pst-5 Stile Formed Ridge losure...pst-5 Universal losure...pst-5 Tube Sealant...PST-5 Tape Sealant...PST-5 Rubber Roof Jack...PST-5 Touch-Up Paint...PST-5 Stile Roof Vent...PST-5 Vent Material...PST-5 Testing Information UL 580 Wind Uplift Information...PST-6 Section Properties and General Information...PST-7 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-

Panel Overview PANEL PROFILE 2" /2" Step /6" Available in lengths up to 20'-0" 2" 9.4" overage 42." Overall width 2" SLOPE SUBSTRATE OVERAGE LENGTH AVAILABILITY APPLIATION PERFORMANE TEST FASTENING SYSTEM FASTENERS MATERIALS FINISH The minimum recommended slope for any Stile roofing panel is :2. The recommended substrate is 5 /8" plywood with a 0 pound felt moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure. If your application is over a solid substrate other than 5 /8" plywood, please contact the your Metal Sales branch location (see pages PGI-2-). Each panel has a coverage of 9.4" ( meter). factory cut length is '-0", and the maximum panel length is 20'-0". Lengths between '-0" and 20'-0" will be cut at '-0" increments. Stile panels are available in 26 Gauge Galvanized (G-90) coating. Architectural panel. UL 580, UL 790, UL 26, UL 228, Miami-Dade ounty, FB Direct Fasten (exposed). The fastener selection guide should be consulted for choosing proper fasteners for specific applications. Quantity and type of fastener must meet necessary loading and code requirements (see PGI-2-4). Steel Grade 40, per ASTM A-65 ** PVDF Fluorocarbon ** Meets both Kynar 500 and Hylar 5000 specifications. PST-2 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/

Flashing Profiles EAVE EXTENDED EAVE LEAT /8" X* 2 /2" 5 /8" Hem Length 0'-2" - *Specify Slope Angle 6" /2" X* " 5 /8" Length 0'-2" - *Specify Slope Angle 2 /2" 5 /2" Length 0'-2" STILE STARTER BOX GUTTER BOX GUTTER END /8" /2" Hem " /2" 2 /8" X* 4" " " 4" " Length 0'-2" UNIVERSAL GUTTER/ DOWNSPOUT STRAP Hem Length 0'-2", 20'-" - *Specify Slope Angle DOWNSPOUT 4" x /2" 95 0 ELBOW 4" x /2" 4" /2" 4" /2" 6" /2" Length 0'-2", 20'-" (Also available 6" x 4") (Also available 6" x 4") DOWNSPOUT BRAKET VALLEY VALLEY OVER 4" X* /2" 2" Hem X* 5 /8" (Also available 6") Length 0'-2", 20'-" - *Specify Slope Angle Length 0'-2" - *Specify Slope Angle FORMED RAKE " 7 /8" RAKE 4" RAKE STARTER /2" 2 7 /8" /4" 2 /6" 2 /6" /4" Length '-6" Hem Length 0'-2", 20'-" 5 /8" 4 /2" Length 0'-2" Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-

Flashing Profiles (cont.) PITH BREAK OUNTER FLASHING REGLET FLASHING /2" X* 4" 5 /8" " /4" 2" " 6" /4" Hem Length 0'-2" - *Specify Slope Angle Length 0'-2" Length 0'-2" RIDGE/HIP OVER FORMED RIDGE VENT DRIP /2" /4" 5 /8" Hem X* /4" 7 /8" /2" 4" /4" /4" 6 5 /8" /4" 60 20 /4" Length 0'-2", 20'-" - *Specify Slope Angle Length '-6" Length 0'-2" STILE -LOSURE JUNTION SHEET STILE RIDGE DRIP /4" /2" 2" 7 /8" X* 4 /2" 47 / 2 9 /6" Length 0'-2", 20'-" Length '-" *Specify Slope Angle - Indicates color side of flashing. PST-4 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/

Accessory Profiles STILE INSIDE/OUTSIDE LOSURE STILE FORMED RIDGE LOSURE UNIVERSAL LOSURE Polyethylene Foam TUBE SEALANT Polyethylene Foam TAPE SEALANT " x / 2" x 50' Polyethylene Foam " x / 2" x 0' Polyethylene Foam RUBBER ROOF JAK 0. oz. artridge Urethane TOUH-UP PAINT 7 /8" X /6" X 25' Double Bead Butyl - Gray STILE ROOF VENT 4 /2" MINI ( /4" to /8" O.D. Pipe) #2 ( /4" to " O.D. Pipe) #4 (" to 6" O.D. Pipe) #6 (6" to 9" O.D. Pipe) #8 (7" to " O.D. Pipe) VENT MATERIAL /8" 4 /8" Front View 7 /8" 5 /8" 4" Available in pints PVDF STILE VALLEY LOSURE Side View 6 /4" Right Valley losure Left Valley losure Polyethylene Foam Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-5

UL 580 Wind Uplift Information 6" o.c. 5 6 2 5A 7 4 5 6 2 STILE onstruction No. 5 November, 999 Uplift - lass 90 Fire Not Investigated. Metal Roof Deck Panels* No. 26 MSG min thick coated steel. Width 9.4 in., height at ribs -/6 in. METAL SALES MANUFATURING ORPORATION - Stile 2. over Board (Optional)-/4 in. Georgia-Pacific Dens- Deck.. Underlayment 0 lb organic felt. Sides overlapped min 2 in., end laps per manufacturer s instructions. 4. Insulation* (Optional)-Any UL lassified rigid insulation, thickness not to exceed -/2 in. 5. Fasteners (Screws) Fasteners to be No. 4-4 x -/2 in., hex head, Type AB, self- tapping screws with sealing washer and painted finish. 5A. Fasteners (Rivets) Fasteners used to attach panels (Item ) at side and end laps to be /8 in. diameter by /6 in. long stainless steel pop rivets. 6. Plywood Decking Decking to be min 5/8 in. (9/2 in. actual) thick. APA 20 span rated plywood sheathing. Fastened to supports with No. 8 by 2 in. long coarse thread wood screws. All butt joints to be sealed against leakage by using tape and/or caulk or with one-part urethane sealant. 7. Supports (Joists) Spaced max 2 ft O. Graded dimension lumber, No. 2 or better. Refer to general information, Roof Deck onstruction, for Items not evaluated. *Bearing the UL lassification Marking U L Underwriters Laboratories Inc. LISTED PST-6 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/

Section Properties and General Information 2" 2" Available in lengths up to 20'-0" 9.4" overage 42." Overall width 2" Ga. 26 Width (in.) Yield KSI 9.4" 25 Weight PSF 0.8 SETION PROPERTIES Top in ompression Ixx In 4 /ft Sxx In /ft Bottom in ompression Ixx In 4 /ft Sxx In /ft 0.096 0.0644 0.096 0.064 ALLOWABLE UNIFORM LIVE LOADS PSF ( or More Equal Spans) Outward Uplift (Stress) Load '-0" 2'-0" '-0" 0 77 50. Theoretical section properties have been calculated per AISI 200 Specification for the Design of old-formed Steel Structural Members. Ixx and Sxx are effective section properties for deflection and bending. 2. Allowable load is calculated in accordance with AISI 200 specifications considering bending, shear, combined bending and shear, deflection, uplift testing, pullout from 5/8" plywood, and pullover. Allowable load considers the worst case of and 4 equal span conditions. Allowable load does not address web crippling. Panel weight is not considered.. Deflection consideration is limited by a maximum deflection ratio of L/80 of span. 4. Allowable loads do not include a / stress increase in uplift. ATTAHMENT DETAIL High end Sidelaps fastened '-0" o.c. with a /8" x /6" Pop Rivet or a /4"-4 x 7 /8" Stitch Screw FASTENING PATTERNS / 4"-4 x / 2" Woodscrew XL Stile Panel Stile losure Tube Sealant (Top and Bottom of losure) End Fastening Pattern Pop Rivet or Stitch Screw w/ Tube Sealant END FASTENING PATTERN / 8" x / 6" Pop Rivet with Tube Sealant / 4"-4 x / 2" Woodscrew XL Stile Panel Interior Fastening Pattern at every third step Low end End Fastening Pattern GENERAL INFORMATION Slope The minimum recommended slope for the Stile roof panel is :2. Substructure The recommended substrate is 5 / 8" plywood with a 0 pound felt moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure. NOTE: Stile roof panels are not recommended for use over open structural framing. overage Stile panels have a coverage of 9.4" ( meter). Length factory cut panel length is '-0". Maximum panel length is 20'-0". Panel lengths are available in '-0" increments. Fasteners The fastener selection guide should be consulted for choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading and code requirements. NOTE: All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment. Availability Finish: Kynar 500 (PVDF) colors. Gauge: 26 ga standard Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-7

Design / Installation onsiderations FASTENER INSTALLATION TEHNIQUE Recommended Tool Type - Use depth locating nose or adjustable clutch on screw gun to prevent overdrilling and strip out. Do not use impact tools or runners. Seating the washer - Apply sufficient torque to seat the washer - do not overdrive the fastener. ORRET Sealing material slightly visible at edge of metal washer. Assembly is watertight. TOO LOOSE Sealing material is not visible; not enough compression to seal properly. TOO TIGHT Metal washer deformed; sealing material pressed beyond washer edge. WOODSREW To prevent wobbling - Make sure fastener head is completely engaged in the socket. If the head does not go all the way in the socket - tap the magnet deeper into the socket to allow full head engagement. Metal chips will build up from drilling and should be removed from time to time. Protect drill point - Push only hard enough on the screw gun to engage clutch. This prevents excess friction and burn out of the drill point. orrect pressure will allow screw to drill and tap without binding. Drilling through sheet and insulation - Ease up on pressure when drilling through insulation to avoid striking the purlin or girt with the point - apply more pressure after drill point contacts purlin or girt. ONDITION OF SUBSTRUTURE Whether over solid substrate or open structural framing, panel distortion may occur if not applied over properly aligned and uniform substructure. The installer should check the roof deck for squareness before installing Stile panels. Several methods can be used to verify squareness of the structure for proper installation of the panels. METHOD "A" - One method for checking the roof for squareness is to measure diagonally across one slope of the roof from similar points at the ridge and eave and obtain the same dimension. METHOD "B" - The -4-5 triangle system may also be used. To use this system measure a point from the corner along the edge of the roof at a module of three (). Measure a point from the same corner along another edge at a module of four (4). Then by measuring diagonally between the two points established, the dimension should be exactly a module of five (5) to have a square corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square, the roof system cannot be installed as shown in these instructions. METHOD A 0 0 5 4 METHOD B PST-8 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/

Design / Installation onsiderations (cont) VENTILATION Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting problems of moisture damage and loss of insulation efficiency. ondensation occurs when moisture laden air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique with metal roofing; these problems are common to all types of construction. The underside of the metal roof on a typical Architectural building should be protected from condensation by installing panels directly over a minimum 0 lb moisture barrier and uniform solid substrate. This reduces airspace and the potential of condensation forming on the underside of the panels. Vent Vent Insulation Vent at wall Vent at eave Typical metal building (no attic) Building with attic or retrofitted PANEL APPLIATIONS The following chart highlights UL 580 lass 90 for fastener spacing on the selected applications (see Fastener Selection Guide page PGI-2-4 for other fasteners available). For more information on UL onstruction numbers, refer to UL Roofing Materials and System Directories. PANEL TYPE APPLIATION INSTALLATION REQUIREMENTS FASTENER SPAING TYPE OF FASTENER NUMBER REQUIRED STILE FASTENERS OVER 5 /8" PLYWOOD DEK ONST. #5 UL-90 26 GAUGE '-0" O..** /4"-4 x /2" ABMP XL - PAINTED 4 FASTENERS* * ABMP XL Fastener also available in # /4-4 x " - Painted. ** Based on UL-580. Subject to project loading, closer fastener spacing may be required. ontact your local Metal Sales branch representative for more information (see pages PGI-2-). Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-9

Eave Detail :2 Slope /4"-4 x /2" Woodscrew XL ('-0" o.c.) Stile Starter /6" x 6" Spacer Stile losure /4"-4 x /2" Woodscrew XL (see below) leat Eave #0-2 x " PHW ('-0" o.c.) /4"-4 x /2" Woodscrew XL STILE :2 Slope Extended Eave Detail /4"-4 x /2" Woodscrew XL ('-0" o.c.) Stile Starter /6" x 6" Spacer Stile losure /4"-4 x /2" Woodscrew XL (see below) Extended Eave #0-2 x " PHW ('-0" o.c.) leat /4"-4 x /2" Woodscrew XL PST-0 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/

Gutter Detail :2 Slope /4"-4 x /2" Woodscrew XL ('-0" o.c.) Stile Starter /6" x 6" Spacer Stile losure /4"-4 x /2" Woodscrew XL (see below) /8" x /6" Pop-Rivet Universal Gutter / Downspout Strap Box Gutter # /4-4 x /2" Woodscrew XL STILE Valley Detail :2 Slope /8" x /6" Pop-Rivet (every other rib) /4"-4 x /2" Woodscrew XL (see below) Universal losure Valley Valley Plate /4"-4 x /2" Woodscrew XL Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-

Slope hange Detail :2 Slope Stile losure /4"-4 x /2" Woodscrew XL (see below) Pitch Break /8" x /6" Pop-Rivet (every other rib) Stile losure /4"-4 x /2" Woodscrew XL (see below) /4"-4 x /2" Woodscrew XL STILE Endlap Detail /4"-4 x /2" Woodscrew XL (see below) Tube Sealant (put in flats) :2 Slope 4" overlap /4"-4 x /2" Woodscrew XL PST-2 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/

Rake Detail /8" x /6" Pop-Rivet ('-0" o.c.) Rake Rake Starter leat Fastener (by others) /4"-4 x /2" Woodscrew XL ('-0" o.c.) STILE Formed Rake Detail Formed Rake Rake Starter /4"-4 x /2" Woodscrew XL ('-0" o.c.) Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-

Rake Parapet Siding Detail Pitch Break Fastener (by others) Rake Starter /8" x /6" Pop-Rivet ('-0" o.c.) /4"-4 x /2" Woodscrew XL ('-0" o.c.) /4"-4 x /2" Woodscrew XL ('-0" o.c.) STILE :2 Slope Endwall with ounter Detail Tube Sealant ounter Flashing Fasteners (by others) Pitch Break /8" x /6" Pop-Rivet (every other rib) Stile losure /4"-4 x /2" Woodscrew XL (see below) /4"-4 x /2" Woodscrew XL PST-4 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/

Endwall with Reglet Detail :2 Slope Tube Sealant Reglet Flashing Fasteners (by others) Pitch Break /8" x /6" Pop-Rivet (every other rib) Stile losure /4"-4 x /2" Woodscrew XL (see below) /4"-4 x /2" Woodscrew XL STILE Junction Sheet Detail :2 Slope Tube Sealant Fasteners (by others) ounter Flashing Junction Sheet /4"-4 x /2" Woodscrew XL (see below) /4"-4 x /2" Woodscrew XL Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-5

Ridge/Hip Detail :2 Slope /8" x /6" Pop-Rivet (every other rib) Stile losure /4"-4 x /2" Woodscrew XL (see below) Ridge/Hip over /4"-4 x /2" Woodscrew XL STILE :2 Slope Formed Ridge/Hip Detail /4"-4 x /2" Woodscrew XL (see below) /8" x /6" Pop-Rivet (every other rib) Stile losure / Stile Hip losure Formed Ridge/Hip over /4"-4 x /2" Woodscrew XL PST-6 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/

:2 Slope 7 /8" Formed Vented Ridge Detail /8" x /6" Pop-Rivet ('-0" o.c.) Stile Ridge Drip Offset leat #4- x 2" ('-0" o.c.) Vent Material Vent Drip Stile losure / Stile Hip losure Formed Ridge /8" x /6" Pop-Rivet /4"-4 x /2" Woodscrew XL (see below) /4" /4"-4 x /2" Woodscrew XL STILE :2 Slope Roof Vent Detail 9 /2" /4"-4 x /2" Woodscrew XL Stile Roof Vent Stile Roof Vent 7" Stile Roof Panel Roof Opening 9 /2" x 7" Field ut Roof Opening Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-7

Notes PST-8 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/