General Construction Supervisory Authority Approval

Similar documents
Translation authorised by DIBt. to: 1 December January 2017 I /16

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

HUS3-H 8 / 10 / 14 Carbon steel concrete screw with hexagonal head. HUS3-C 8 / 10 Carbon steel concrete screw with countersunk head

DECLARATION OF PERFORMANCE

European Technical Assessment. ETA-11/0336 of 17 July English translation prepared by DIBt - Original version in German language.

Anchor Fastening. Technology Manual HUS3. Screw Anchor HUS3-H 6/8/10/14 HUS3-C 6/8/10 HUS3-HF 8/10/14 HUS3-A 6 HUS3-I 6 HUS3-P 6 HUS3-PS 6 HUS3

HLC. Hex head nut with pressed-on washer HLC-H. Bolt version with washer HLC-L. Torx round head HLC-SK. Torx Counter sunk head HLC-EC

HSA Carbon steel with DIN 125 washer. HSA-R Stainless steel A4 with DIN 125 washer. HSA-R2 Stainless steel A2 with DIN 125 washer

PRODUCT DATA SHEET SAFETY BOLT

SUPERPLUS M8-M16. The undercut fixing system that does not require a special setting tool. FUNCTION BENEFITS

English translation prepared by CSTB - Original version in French language. PoSB-PRO Power Screwbolt

HKD Push-in anchor, Single anchor application

Z from: 12 October 2016

English translation prepared by CSTB - Original version in French language. FRIULSIDER Via Trieste,1 I San Giovanni al Natisone (UDINE) ITALIE

HKD Push-in anchor, Single anchor application

Hilti HUS3 SCREW ANCHOR. Technical Datasheet Update: Oct-18

HVU with HAS/HAS-E rod adhesive anchor system

National technical approval Coupler

To: Firm: Project: Product Specified: Specified Location:

Hilti HIT-HY 170 mortar with HIT-V rod. Anchor Fastening Technology Manual. Hilti HIT-HY 170 with HIT-V HIS-(R)N 03 / /

HKD Push-in anchor, Single anchor application

HST3 Metal expansion anchor

DECLARATION OF PERFORMANCE

D E U T S C H E S I N S T I T U T F Ü R B A U T E C H N I K

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

SIMPLY THE BEST HEAVY DUTY SELF-UNDERCUTTING ANCHOR IN THE WORLD

HST Carbon steel. HST-R Stainless steel HST-HCR High corrosion resistance steel. Fire resistance

from: 1 st April 2017 to: 1 st April 2018

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

English translation authorized by DIBt Original version in German language

Concrete Screw-Anchors

European Technical Assessment. ETA-17/0237 of 15/05/2017. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

Declaration of Performance No1109-CPD-0080 According to the Regulation EU No 305/2011

EJOT Concrete screws. ETA-approved concrete screws for cracked and non-cracked concrete

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

HUS-HR / HUS-CR Screw anchor

General building approval

English translation prepared by CSTB - Original version in French language. Throughbolt PTB-ETA7-PRO

HUS3 SCREW ANCHOR. Technical Datasheet Update: May-18

SINGLE ANCHOR USE FOR NON-CRACKED CONCRETE

HDA-P HDA-PR HDA-PF Anchor for presetting. HDA-T HDA-TR HDA-TF Anchor for through-fasting. Nuclear power plant approval

ITW Construction Products Italy S.r.l. V.le Regione Veneto, PADOVA (PD) ITALIEN. V.le Regione Veneto, PADOVA (PD) ITALIEN

English translation prepared by CSTB - Original version in French language. Throughbolt TX

Z November 2011

English translation prepared by CSTB - Original version in French language POWERS PB-PRO-S

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

English translation prepared by CSTB - Original version in French language

Hilti HIT-HY 200-R 500 ml foil pack (also available as 330 ml foil pack) Static mixer

European Technical Approval ETA-08/0058

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

HKD redundant FLUSH ANCHOR. Technical Datasheet Update: Mar-18

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Technical data No. 17/0001 of 25/04/2017

Declaration of Performance No1109-CPD-0079 According to the Regulation EU No 305/2011 HXE01 - HXE02 - HXE12 - HXE85 - HXE03

European Technical Approval ETA-12/0456

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

General Design Approval

WARSAW ul. FILTROWA 1 phone: (48 22) , (48 22) fax: (48 22)

HILTI HSC UNDERCUT ANCHOR. Technical Datasheet Update: Sep-18


Hilti HIT-CT 1 with HIT-V

HSC UNDERCUT ANCHOR. Technical Datasheet Update: Jul-18

English translation prepared by DIBt Original version in German language

DRILL. DRIVE. DONE. EVERYWHERE.

DRILL. DRIVE. DONE. EVERYWHERE.

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

General Information. Installation Information Design Information Material Information Ordering Information

Hilti HIT-RE 100 mortar with rebar (as anchor)

NEW fischer concrete screw ULTRACUT FBS II A4

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.1.

Hilti HVU-TZ foil capsule. HAS-TZ HAS-R-TZ HAS-HCR-TZ rod. Shock

European Technical ETA-04/0023 Assessment of 17 October 2017 General Part

Hilti-HY 110 available in 330ml and 500ml foil packs. Static mixer HIT M1. Rebar BSt 500 S

Frame fixing SXS-F US

The high-performance frame fixing with SX-technology VERSIONS. zinc-plated steel stainless steel BUILDING MATERIALS

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

Hilti, Inc South 122 nd East Avenue Tulsa, OK

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

MULTI-MONTI Technical Manual

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

ETA-13/0584 of 24/09/2014. European Technical Assessment. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

PRODUCT DATA SHEET THROUGH BOLTS. facebook.com/sormat youtube.com/sormatfixing SORMAT Product data sheet 1217

European Technical Assessment ETA 14/0077

Declaration of Performance No. DPGEB1006 v2.1

Fig Beam Clamp Retaining Strap (B-Line B3367)

ULTRAPLUS M12-M36. The undercut anchor for exceptionally high loads in cracked and non-cracked concrete also for shock and seismic loads.

European Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the

(English language translation, the original version is in French language) SPIT FIX3. Société Spit Route de Lyon F BOURG-LES-VALENCE France

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

PRODUCT DATA SHEET THROUGH BOLTS S-KA S-KAK S-KAH A4 S-KAH HCR S-KAR A2 HHA A2

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS

Intended uses of the construction product, in accordance with the applicable harmonized technical specification as foreseen by the manufacturer:

ULTRAPLUS M12-M36. The undercut anchor for exceptionally high loads in cracked and non-cracked concrete also for shock and seismic loads.

The following excerpt are pages from the North American Anchor Fastening Technical Guide, 2011.

Transcription:

General Construction Supervisory Authority Approval (Translation of the German original text which has not been checked by the DIBt.) Approval no.: Z-21.8-2018 Period of validity: April 1, 2014 until: April 1, 2019 Hilti Deutschland AG Hiltistraße 2 86916 Kaufering Germany Subject of approval: Hilti Betonschraube HUS3-H Hilti HUS3-H concrete screw anchor The aforementioned subject of approval is herewith granted General Construction Supervisory Authority Approval. This General Construction Supervisory Authority Approval comprises five pages and five annexes.

General Construction Supervisory Authority Approval Approval no.: Z-21.8-2018 Page 2 of 5 April 1, 2014 I GENERAL PROVISIONS 1 This General Construction Supervisory Authority Approval verifies the suitability (fitness for the intended purpose) of the subject of the approval in keeping with the state construction ordinances. 2 If the General Construction Supervisory Authority Approval lays down requirements regarding the special expertise and experience that persons in charge of the manufacturing of construction products are required to have in accordance with state regulations corresponding to 17 Section 5 of the model building code, please note that this expertise and experience can be attested through equivalent evidence or verification provided by other member states of the European Union. This also applies to equivalent verification presented within the scope of the European Economic Area (EEA) or other bilateral agreement. 3 The General Construction Supervisory Authority Approval is no substitute for the mandatory authorization, consent, permission and certification required for prospective building projects. 4 The General Construction Supervisory Authority Approval is granted without prejudice to the rights of third parties, especially private protective rights. 5 Notwithstanding any further regulations in the Special Provisions Section, the manufacturer and distributor of the subject of the approval shall provide the user with copies of the General Construction Supervisory Authority Approval. Furthermore, they shall inform the user that the General Construction Supervisory Authority Approval must be available at the place of use. Copies of the General Construction Supervisory Authority Approval must be made available to the applicable authorities on request. 6 The General Construction Supervisory Authority Approval may be copied only in its entirety. Publication of extracts is subject to approval by the DIBt. The text and depiction of the product in advertising material must not contradict The General Construction Supervisory Authority Approval. Translations of the General Construction Supervisory Authority Approval must contain the following notice: Translation of the German original text which has not been checked by the DIBt. 7 The General Construction Supervisory Authority Approval is revocable. The provisions made in the General Construction Supervisory Authority Approval may be subsequently amended or modified, especially when new technical findings give reason for such amendment. Z12911.14 1.21.8-112/13

General Construction Supervisory Authority Approval Approval no.: Z-21.8-2018 Page 3 of 5 April 1, 2014 II SPECIAL PROVISIONS 1 Subject of approval and scope 1.1 Subject of approval 1.2 Scope The subject of this approval is the Hilti HUS3-H concrete screw anchor (hereinafter referred to as the anchor ) in the sizes 10 mm and 14 mm diameter, each with three different setting depths (length of thread engagement). The HUS3-H concrete screw anchor is a special screw bolt, with hexagonal head, made from galvanized steel. The anchor is screwed into a predrilled cylindrical drill hole. The special thread of the anchor cuts an internal thread into the member while setting. The anchorage is characterised by mechanical interlock in the special thread. The anchor in an installed state is shown in Annex 1. The anchor may be set in reinforced or unreinforced concrete of the grade (strength class) of at least C20/25 and maximum of C50/60 in accordance with DIN EN 206-1:2001-07 Concrete - Part 1: Specification, performance, production and conformity. The anchor may be set before the concrete has reached its required characteristic compressive strength so long as the strength of the concrete is verified in accordance with Section 4.1. The anchor may be used only for the temporary fastening of construction site equipment or facilities, e.g. supports, safety railings and scaffolds. After removal by unscrewing, the anchor may be reused in other drilled holes. It may not, however, be screwed back into the same hole a second time. Before each reuse, the anchor must be checked visually and using the sleeve gauge in accordance with the instructions given in Section 4.3. After installation, the anchors must be continuously checked for visible signs of damage (e.g. due to corrosion) and replaced if necessary. The anchor may be set in cracked or uncracked concrete. The anchor may be used only in situations where no requirements regarding fire resistance (duration of resistance to fire) require to be met by the entire structure, including the screw anchor. The anchor may be used only for the temporary fastening applications for which it is intended, in indoor and outdoor environments. 2 Provisions applicable to the construction product 2.1 Characteristics and composition The anchor must comply with the drawings and specifications given in the annexes to this approval and with the European Technical Approval ETA-13/1038. The anchor is made from a non-flammable material of the Class A in accordance with DIN 4102-1:1998-05 Fire behavior of building materials and building components - Part 1: Building materials; concepts, requirements and tests. Z12911.14 1.21.8-112/13

General Construction Supervisory Authority Approval Approval no.: Z-21.8-2018 Page 4 of 5 April 1, 2014 3 Provisions for planning and design 3.1 Planning 3.2 Design The anchor fastenings must be planned in accordance with good engineering practice. Checkable calculations and design drawings must be produced, taking into account the loads that are to be carried. The design drawings must contain details of the exact position and size of the anchor. The forces that can be taken up by the concrete in the immediately surrounding area have been verified. Verification must be provided of how the loads to be anchored are taken up by the structural member. Additional stresses in the screw anchor, in the part to be fastened or in the structural member in which the anchor is set, that may result from restricted changes in shape or size (e.g. due to temperature changes), must be taken into account. The minimum distances (spacing or distances from edges) and minimum member thicknesses given in Annex 5 must always be complied with. Proof must be provided that the design/rated value for the action F Ed does not exceed the design/rated value for the action F Rd : F Ed F Rd F Ed, F Rd in [kn] The design/rated resistance values apply to all loading directions, irrespective of the failure mode. The resistance values with reference to anchor size, setting depth and concrete strength f ck,cube are given in Annex 5. 4 Provisions for installation or use of the product 4.1 General points Installation of the anchors is to be carried out in accordance with the design drawings provided in Section 3.1. The screw anchor may be set in young concrete before it has reached its characteristic compressive strength f ck,cube (i.e. less than 28 days after the concrete was poured). In this case the concrete compressive strength must be determined according to the principles of DIN 1048 and it must reach a value of at least f c,cube 10 N/mm². 4.2 Drilling and cleaning of the hole The hole to be drilled must be positioned in such as way that it does not come into conflict with the reinforcement in the concrete, i.e. avoiding damage to the reinforcement. The hole must be drilled perpendicular to the surface of the concrete using a carbide-tipped concrete/masonry drill bit. The carbide-tipped concrete/masonry drill bit must comply with the requirements given in the information sheet published by the DIBt Specification, requirements and testing of carbide-tipped concrete/masonry drill bits used for drilling anchor holes (issued January 2002). Proof that the drill bit specification is adhered to must be provided in the form of acceptance test certificate 3.2 (DIN EN 10204) or by the test mark (see information sheet) issued by the Prüfgemeinschaft Mauerbohrer e.v., Remscheid (PGM Masonry Drill Bit Certification Board). Nominal drill bit diameter, diameter at the cutting edge and hole depth must meet the specifications given in Annex 3. The drilling dust must be removed from the hole. If a hole is drilled or positioned incorrectly, a new hole must be drilled at a distance equal to at least twice the depth of the incorrectly drilled hole. Z12911.14 1.21.8-112/13

General Construction Supervisory Authority Approval Approval no.: Z-21.8-2018 Page 5 of 5 April 1, 2014 4.3 Setting the anchor The anchor is intended only for temporary use in a single drilled hole. After unscrewing and removal, the anchor may be used in other drilled holes. It may not, however, be screwed into the same hole a second time. Before each reuse, thread wear must be checked using the corresponding sleeve gauge as shown in Annex 2. The anchor may be reused only if it does not project beyond the rear end of the sleeve when inserted into the gauge (see illustration B7.b, Annex 4). As a fundamental principle, anchors that show visible signs of damage, e.g. material loss due to corrosion, may not be reused. The screw anchor may be driven into the hole using a tangential impact wrench. In order to prevent the anchor spinning in the hole, wrenches with a high power output should be equipped with an automatic cut-out, e.g. controlled by way of the depth gauge. The anchor is anchored correctly when: - the entire surface of the foot plate of the part to be fastened is pulled against the surface of the concrete (no gap), - the head of the anchor is in contact with the foot plate, - the anchor cannot (easily) be tightened any further, - the setting depth h nom has been achieved. 4.4 Checking the installation When installing the anchors, the contractor responsible for the anchor installation work or his appointed site supervisor or a suitably qualified and experienced deputy site supervisor must be present on the site. He/she must ensure that the work is carried out correctly. While the installation of the anchors is being carried out, a record of the concrete compressive strength, in accordance with Section 4.1, must be kept by the site supervisor or his deputy for verification purposes and to confirm that the anchors have been installed correctly. The installed anchors must be checked correspondingly by the site supervisor or his deputy, in accordance with the information given in Section 1.2, and records kept of the results of the checks. The records must be kept available on the site for the duration of the construction work and must be presented on demand to persons authorized to check these records. After completion of the work they must be kept along with the supplier s delivery note for at least 5 years by the contractor responsible for the work. Z12911.14 1.21.8-112/13

Product after installation HUS3-H sizes 10 and 14 (hexagonal head) Hilti HUS3-H concrete screw anchor Product description State after installation Annex 1

Table 1: Specification and markings Anchor size 10 14 Length of anchor in concrete h nom1 h nom2 h nom3 h nom1 h nom2 h nom3 h nom [mm] 55 75 85 65 85 115 Threaded outer diameter d t [mm] 12.4 16.85 Core diameter d k [mm] 9.90 12.95 Shank diameter d s [mm] 10.55 13.80 Cross section A s [mm 2 ] 77.0 131.7 A HUS3 : Hilti Universal Screw, 3 rd generation H : Hex. head 10 : Nominal anchor bolt size 45/25/15 : Max. thickness of the fixture part t fix1 /t fix2 /t fix3 depending on embedment depth h nom1 /h nom2 /h nom3 Table 2: Sleeve gauge specification Anchor size 10 14 Sleeve inner diameter Ø i [mm] 11.7 16.0 Sleeve outside diameter Ø e [mm] 17.0 22.0 Sleeve length Lt [mm] 28.0 40.3 Hilti HUS3-H concrete screw anchor Product description Material and specification Annex 2

Table 3: Installation parameters Anchor size 10 14 h nom1 h nom2 h nom3 h nom1 h nom2 h nom3 Nominal embedment depth h nom [mm] 55 75 85 65 85 115 Nominal drill hole diameter d 0 [mm] 10 14 Cutting diameter of drill bit d cut [mm] 10.45 14.50 Clearance hole diameter d f [mm] 14 18 Wrench size AF [mm] 15 21 Depth of drill hole h 1 [mm] 65 85 95 75 95 125 Setting tool to set the anchor Hilti SIW 22 T A 1) 1) Installation using other impact screw driver with equivalent power output is permissible Table 4: Installation parameters: Screw length and max. thickness of part to be fastened t fix Anchor size 10 14 Thread length [mm] Nominal embedment depth [mm] h nom1 55 h nom2 75 h nom3 85 h nom1 65 h nom2 85 h nom3 115 Thickness of part to be fastened [mm] t fix1 t fix2 t fix3 t fix1 t fix2 t fix3 60 5 70 15 75 10 80 25 5 90 35 15 5 100 45 25 15 35 15 110 55 35 25 130 75 55 45 65 45 15 150 95 75 65 85 65 35 Hilti HUS3 H concrete screw anchor Intended use Installation parameters Annex 3

Anchor setting (driving) instructions for reuse in temporary fastening applications or Hilti HUS3 H concrete screw anchor Intended use Anchor setting instructions for reuse in temporary fastening applications Annex 4

Table 5: Minimum thickness of concrete member, minimum spacing and edge distances in cracked and uncracked concrete HUS3 anchor size 10 14 h nom1 h nom2 h nom3 h nom1 h nom2 h nom3 Nominal embedment depth h nom [mm] 55 75 85 65 85 115 Min. thickness of concrete member h min [mm] 115 150 175 130 175 255 Min. spacing distance s [mm] 225 300 345 255 345 510 Min. edge distance (load direction 1) c 1 [mm] 75 100 115 85 115 170 Min. edge distance (load direction 1) c 2 [mm] 115 150 175 130 180 260 Table 6: Design resistance for all loading directions in cracked and uncracked concrete HUS3 anchor size 10 14 h nom1 h nom2 h nom3 h nom1 h nom2 h nom3 Nominal embedment depth h nom [mm] 55 75 85 65 85 115 Design resistance in concrete with compressive strength f ck,cube 2 1) F Rd Design resistance in concrete with compressive strength f ck,cube 2 1) F Rd Design resistance in concrete with compressive strength f ck,cube 2 1) F Rd 1) Partial safety factor is included. [kn] 3.3 5.3 6.3 4.4 7.0 12.3 [kn] 4.0 6.4 7.8 5.4 8.5 15.0 [kn] 4.7 7.4 9.0 6.2 9.9 17.3 Hilti HUS3 H concrete screw anchor Performances Min. thickness of cocnrete member, min. spacing and distances and design resistance Annex 5