Micheal Okpara University of Agriculture Umudike. Abstract

Similar documents
An Assessment of Thermal Comfort in Hot and Dry Season (A Case Study of 4 Theaters at Bayero University Kano)

AN ASSESSMENT OF THERMAL COMFORT IN NATURALLY VENTILATED ARCHITECTURAL STUDIO IN ABIA STATE UNIVERSITY, UTURU

REDEFINING APPROPRIATE THERMAL COMFORT STANDARD FOR NATURALLY VENTILATED BUILDINGS IN TROPICS (SINGAPORE AND INDONESIA PERSPECTIVE)

Energy and indoor temperature consequences of adaptive thermal comfort standards

Perception of Thermal Comfort for Naturally Ventilated High School Classrooms in San Rafael, CA

PREDICTION OF THERMAL SENSATION IN NON-AIR- CONDITIONED BUILDINGS IN WARM CLIMATES

SUBJECTIVE AND MEASURED THERMAL COMFORT IN ITALIAN UNIVERSITY CLASSROOMS IN HEATED AND FREE RUNNING CONDITIONS

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

A Field Study of the Thermal Environment in Residential Buildings in Harbin

Shifting Comfort Zone for Hot-Humid Environments

THERMAL COMFORT OF A COURTYARD IN GUANGZHOU IN SUMMER

Adaptive Thermal Comfort in Warm Dry Climate: Economical dwellings in Mexico

Bio Climatic Analysis of Bhubaneswar-An Investigation to Arrive Human Comfort through Natural Ventilation

Assoc. Professor of Architecture and Env. Health, Enugu State University of Science and Tech.,Enugu. And

Air Movement Preference and Thermal Comfort A survey in classrooms during summer season in Brazil

Thermal comfort assessment of Danish occupants exposed to warm environments and preferred local air movement

A Comparison of Calculated and Subjective Thermal Comfort Sensation in Home and Office Environment

Thermal Comfort Zone for Thai People

Thermal comfort under transient seasonal conditions of a bioclimatic building in Greece

A Field Study of Thermal Comfort in Open-plan Office Buildings during Transition Seasons in Harbin. Yunsong Han 1, 2, Huixuan Sun 1, 2, Cheng Sun 1, 2

Thermal environment and thermal comfort in a passive residential building in the severe cold area of China

Field Studies of Subjective Effects on Thermal Comfort in a University. Classroom

COMFORT MODEL FOR LOCAL COOLING. Yufeng Zhang 1 and Rongyi Zhao 2. Beijing, , P.R. China

REAL-TIME CONTROL OF OCCUPANTS THERMAL COMFORT IN BUILDINGS. Galway, Ireland

Behaviour of People in Open Spaces in Dependence of Thermal Comfort Conditions

Findings of Field Survey for Thermal Comfort and Ventilation in US Office Buildings

Prediction of Thermal Comfort. mech14.weebly.com

Thermal Comfort in Architecture

Thermal Comfort Evaluation of HDB flats

Thermal comfort conditions in outdoor spaces

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

ATBU, Journal of Science, Technology & Education (JOSTE); Vol. 3 (4), December, 2015 ISSN:

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

Comparison between thermal comfort predictive models and subjective responses in Italian university classrooms

Allowing for Thermal Comfort in Free-running Buildings in the New European Standard EN15251

Energy simulation of traditional vs. adaptive thermal comfort for two

Thermal comfort study of residents in Mlaten housing Semarang, Indonesia

SET. An analysis of thermal comfort in primary schools in Vietnam BOLOGNA. Thi Ho Vi LE 1, Mark GILLOTT 2, Lucelia RODRIGUES 3

A deep courtyard as the best building form for desert climate, an introduction to effects of air movement (Case study: Yazd)

COMFORT IN AUSTRALIAN OFFICES

Bio-climatic Chart for Different Climatic Zones of Northeast India

THE EFFECTS OF INDOOR ENVIRONMENT IN SUPERMARKET ON CLIENTS' AND OPERATORS' SATISFACTION

Thermal Environment evaluation in commercial kitchens

GUIDELINES FOR DESIGN WITH CLIMATE IN THE SAVANNAH ZONE OF NIGERIA. (Implications for prototype mass housing) ADEGBENRO OLALEKAN O.

Development of the adaptive model for thermal comfort in Japanese houses

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

The applicability of the ISO 7730 (Fanger's comfort model) and the adaptive model of thermal comfort in Jakarta, Indonesia.

Assessment of thermal comfort near a glazed exterior wall

317: Thermal performance of houses located in Florianópolis, southern Brazil

Assessment of thermal comfort inside primary governmental classrooms in hot-dry climates Part II a case study from Egypt

Investigation on Indoor Thermal Satisfaction in the Humid Tropics of Malaysia

A Study of Thermal Comfort and Ventilation Parameters in Air-Conditioned Architectural Studios in a Hot Humid Abia State University, Uturu Environment

GREEN CONCEPT OF THERMAL COMFORT DESIGN FOR SUSTAINABLE HOUSING IN THE TROPICS: Learning from Thermal Comfort in School Buildings 1 INTRODUCTION

Energy simulation of traditional vs. adaptive thermal comfort for two moderate climate regions Hensen, J.L.M.; Hensen Centnerová, L.

IMPACT OF THE AIRFLOW INTERACTION ON OCCUPANTS THERMAL COMFORT IN ROOMS WITH ACTIVE CHILLED BEAMS

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

Cost-Benefit Analysis of Dwelling Retrofit Options

Thermal comfort and occupant adaptive behaviour in university offices with cooling and free running modes

ADAPTIVE THERMAL COMFORT IN THE WET TROPICS FOR HOUSING DESIGN WITH PASSIVE COOLING

Analysis of Night Ventilation Potential for Residential Buildings in Hot-Humid Climate of Malaysia

OUTDOOR DESIGN CRITERIA: For the Central Phoenix/East Valley Light Rail Transit System

PERSONAL COOLING USING THERMAL CONDUCTION ON THE DESK

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

RADIANT SLAB COOLING: A FIELD STUDY OF OCCUPANT THERMAL COMFORT. Zhen Tian 1, James A. Love 2

Neutral humidity in low cost dwellings in arid climate

Adaptive thermal comfort evaluation of typical public primary school classrooms in Imo state, Nigeria

Workshop: Architecture-Tradition and Modernization. Climate Responsive Urban Design

Investigation of comfort temperature and the adaptive model in Japanese houses

Investigation and Analysis of Winter Classroom Thermal Environment. In Chongqing

THE USE OF THE CORRECTED EFFECTIVE TEMPERATURE INDEX

Evaluation methods for indoor environmental quality assessment according to EN15251

Potential of passive design strategies using the free-running temperature

Comfort Temperatures Inside Low-Cost Housing Case: six warm climate cities in Mexico

Assessment of thermal comfort in shopping centre transitional spaces

Environmental and human factors influencing thermal comfort of office occupants in hot-humid and hot-arid climates

Human response to individually controlled micro environment generated with localized chilled beam

STUDIES ON THERMAL COMFORT AND ENERGY CONSUMPTION OF HVAC SYSTEM

THERMAL COMFORT IN LECTURE HALLS IN THE TROPICS

SUSTAINABLE BY PASSIVE ARCHITECTURE, USING COURTYARDS IN NON-DOMESTIC BUILDINGS IN SOUTHEAST QUEENSLAND

Information paper 17. Prepared by: David Clark. book:

SIMULATION OF BUILDING THERMAL PERFORMANCE IN AN INSTITUTIONAL BUILDING IN SUBTROPICAL CLIMATE

Impacts of Indoor Temperature and Velocity on Human Physiology in Hot Summer and Cold Winter Climate in China

Influence of Building Orientation on the Indoor Climate of Buildings

Designing Air-Distribution Systems To Maximize Comfort

Children thermal comfort in primary schools in Ho Chi Minh City in Vietnam

A PRELIMINARY THERMAL COMFORT STUDY IN TROPICAL BUILDINGS LOCATED IN MALAYSIA

Do the constants used in adaptive comfort algorithms reflect the observed responses of children in junior school classrooms?

Available online at ScienceDirect. Procedia Engineering 169 (2016 )

Relevant indoor ventilation by windows and apertures in tropical climate: a review study

Application of the adaptive model proposed by ASHRAE 55 in the Brazilian climate context: raising some issues

Outdoor Thermal Comfort in the Hot Arid Climate The effect of socio-economic background and cultural differences

A Study on Natural Ventilation Performance in Selected Historical Building in Kuala Lumpur

HUMAN-BEHAVIOR ORIENTED CONTROL STRATEGIES FOR NATURAL VENTILATION IN OFFICE BUILDINGS

Designing outdoor spaces with COMFORT-EX

Statistical Model Evaluation and Calibrations for Outdoor Comfort Assessment in South Florida.

IMPLICATIONS OF CLIMATE CHANGE AND OCCUPANT BEHAVIOUR ON FUTURE ENERGY DEMAND IN A ZERO CARBON HOUSE

Field Investigation of Comfort Temperature and Adaptive Model in Japanese Houses

Adaptive thermal comfort explained by PMV

Short-term acclimatization effects in an outdoor comfort study

A Study of Local Identity and Local Environment Factors Influenced Architectural Design

Transcription:

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1531 IMPACT OF AIR TEMPERATURE IN THERMAL COMFORT OF INDOORS OF RESIDENTIAL BUILDINGS IN UMUAHIA URBAN ABIA STATE, NIGERIA. Alozie, G.C 1. Ph.D, Odim O. O 1 Ph.D, Alozie, E.N 2 Ph.D 1 Department of Architecture Abia State University Uturu 2 Department of Hospitality Management and Tourism Micheal Okpara University of Agriculture Umudike Abstract Achieving indoor thermal comfort in residential buildings, is very essential, because little we do take place outside. Most residences in Umuahia urban of Abia State Nigeria are cells of unhappiness because their indoors are thermally uncomfortable, thus the aim of this study was to evaluate the impact of air temperature in thermal comfort of residential buildings in Umauhia urban. This was achieved by carrying out air temperature measurement and questionnaire survey of some randomly selected residences in the area to determine the thermal perception of inmates, also evaluate thermal performances of the same residences in response to air temperature. The experiment took place in rainy and dry seasons of 2012, 108 respondents were obtained from twenty seven (27) residences. Data loggers, digital thermometers and measuring tapes were major instruments used, while thermal comfort parameters measured were air temperature, relative humidity and air velocity. The result revealed that 70.3% of the residences did not achieve acceptable indoor thermal comfort, while 69.1% of the respondents voted discomfort. Analysis of respondents also revealed that the inhabitants of the residents with unacceptable temperature, also voted discomfort, thus agreeing with the study index. It was discovered that the residences failed, due to their designs. The study recommended that all building designs originate from the architect. Keywords: Thermal comfort, Residential buildings, Air temperature, Humidity.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1532 1. INTRODUCTION Buildings function mainly to adapt to the prevailing climates and to provide internal and external environment which will be comfortable and conducive for its inhabitants (Akande and Adebamowo 2010). The need for buildings to perform this all important function must be remarked, especially in this era of global warming and climate change. It also becomes essential due to the facts that architects and others in the built environment face a task of developing buildings that will be thermally comfortable and energy efficient (Alozie 2014). Thermal comfort is a necessary feature when considering the functional adequacy of any building space and the suitability of the built environment (Adunola 2015). In further opinion Adunola (2015) believe that in whatever location, that buildings are meant to provide the requisite thermal environment indoors, so that human activities may be carried out conveniently. He further stated that people are affected either positively or negatively inside the building because of their innate physiological responses to their indoor thermal environment. It is obvious then that there is a significant role, thermal comfort plays in human performance at both mental and physiological levels. This makes it necessary then to investigate how residential buildings in Umuahia, a warm humid climate urban environment of Abia State, Nigeria have fared in providing indoor thermal comfort, with particular regard to air temperature. American Society for Heating Refrigerating and Air Conditioning Engineers. ASHRAE, defined thermal comfort as the express satisfaction within the thermal environment, in which at least 80% of sedentary or slightly active

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1533 persons find their environment thermally acceptable. (ASHRAE 2004). Among other definitions of thermal comfort is that presented by Odim (2006) who defined thermal comfort as the condition human beings find themselves when they are satisfied with their environment. The need for the home maker to be thermally accommodated in his environment is seen in Adebayo, Ayuba and Oyetola (2013) assertion of thermal comfort being essential for the wellbeing, productivity and efficiency of occupants Adebayo(2013) then concluded that the preservation of thermal comfort should be defined as an imperative issue. The inability to meet this imperative issue of preservation of this state of mind defined as thermal comfort is described by Cheividyankarn (2007) as the cause of sick building syndrome, resulting from poor indoor air quality. According to Cheividyankarn (2007), because thermal comfort depends on weather and on the environment, therefore the design of the building contributes 75% role to its comfort level. This paper therefore examines the degree to which building designs have affected indoor air temperature, a major determinant of thermal comfort in Umuahia urban environment of Abia State. The study has become necessary because most residences in Umuahia urban environment are known cells of unhappiness, due to the major reason that their architecture does not support them providing thermal comfort naturally (Alozie, 2014). Many field studies carried out in humid climates did not consider the nature of Umuahia climate (warm humid). In warm humid climates temperature and

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1534 relative humidity are high, sometimes above 32 o C and 80% respectively. Air velocity is at 1m/s. The high humidity leaves damp and sticky feeling effect on people which causes discomfort. Studies by Auliciem(1985). Auliciem and de Dear (1986, 1986b); Busch (1990) and de Dear and Fountain (1994) were all in hot humid climates, only little thermal studies exist in warm humid climates, and no major studies exist on Umuahia urban environment. Findings from the study will enable architects, engineers and other environmental designers develop buildings that will be environmentally friendly (sustainable and energy efficient). Buildings that will require little or no mechanical enhancement to function, and provide the desired thermal comfort level indoors. 2 LOCATION AND CLIMATE OF STUDY AREA Umuahia the urban capital city of Abia State is in South Eastern, Nigeria, and located on latitude 51 25 I N and longitude 7 0 10 I E. (Ijioma 2000). Umuahia falls in the tropical rainforest vegetation belt and has an elevation of 250meters above sea height, and falls within the warm humid climate zone. In the warm humid zone, there is very high solar radiation and humidity but with relatively low wind speed (Hyde 2000). The climate data for Umuahia showed that the climate contex combined high temperature (mean max -32 0 C), high humidity (mean max -85%) and low air velocity (mean max -1.55m/s). the maximum

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1535 temperatures were above 30 0 C for all months with exception of August and September. The sequence of weather conditions in any place in Nigeria and other West African countries during the cost of a given year, actually depends on the location of the place in relation to the fluctuating surface reaction of the Inter Tropical Discontinuity (ITD). The ITD movements and effects on various locations in West Africa are discussed in Ojo (1977). 3. METHODOLOGY 3.1 FIELD STUDY The field study was conducted in Umuahia urban environment in the central senatoral area of Abia State. It was carried out with questionnaire survey and field measurements on indoor air temperature character and the nature of residential thermal environment, during the rainy and dry seasons of 2012. This was carried out to get a variation measurement in terms of the indoor and outdoor temperature, relative humidity and air velocity. The field study asked questions based on thermal sensations and were based on the Seven point (ASHRAE Scale -3 to +3), which represented the respondents comfort votes. At the same time, the following thermal variables were measured, indoor air temperature, relative humidity and air velocity. The aim of the field measurement was to match the responses from the questionnaire to the air temperature measurement from the twenty seven residences whose indoor thermal measurements were captured. This matching is

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1536 used to substantiate the Effective Temperature (ET) index thermal comfort range of (20-26 0 C) provided by Fagner (1970) as acceptable thermal comfort temperature range for warm humid climate. The effective temperature index can be defined as the temperature of still, saturated atmosphere which would in the absence of radiation, produce the same effect as the atmosphere in question (Koenigsberg et al, 1973). The ET scale was first developed by Houghton and Maglou in 1923, with subsequent revisions, integrates the effect of these fundamental environmental variables relevant to thermal comfort in any contex, these are air temperature, relative humidity and air movement. The effective temperature has been an internationally accepted thermal comfort scale which has been of wide applicability. However, with recent findings disqualifying the general applicability of thermal indices, it has become pertinent to use field survey results to examine index locally. According to Humphery (1975), field studies of thermal comfort are with two purposes, first is to find a way of describing the thermal environment which correlates well with human response, thus enabling reliable predictions to be made and secondly to define the range of conditions found to be pleasant or tolerable by the population concerned. This contextual study of Umuahia urban environment sought to assess indoor air temperature in residential buildings and compare them with that allowed by studies from Fanger (1970) as comfort limits in warm humid climates. The

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1537 study also includes the physical measurement and analysis of the architecture of the case study buildings, again this became necessary in order to find out the degree to which architectural designs contributed to variations in thermal comfort perception of indoor residential buildings in the study area. The study which considered the local climate characteristics was carried out during two extreme periods of dry and rainy seasons of 2012, while the questionnaire and its application were raised in accordance to 1S0,7730 and 10551 (1994) standards. The questionnaires were distributed and retrieved after a month in each of the seasons, this enabled the respondents assess without bias their perception. 3.2 POPULATION SIZE The research adopted Akande (2010) sampling technique for measurement of indoor thermal comfort in residential buildings in Bauchi due to similarities in both study, but limited to its own sample population. A sample size of 108 in (27) naturally ventilated residential buildings in the study location were collected in both dry and rainy seasons of (2012). Table 1 shows the summary of the subjects of residential occupants in the study area. The population for the study was made up of 52 females (48.1%) and 56 males (51.9%). The percentages of residence with and without mechanical ventilation system (i.e. those using windows only and those not using windows only) were

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1538 21% and 79% respectively. The average age of respondents lie between 30-50 years. Table 1: Summary of the subjects of residential occupants in the study area Season Dry season Rainy season Sample size (male/female) 108(52/56) 108(52/56) Gender (%of sample) Male 51.9 51.9 Female 48.1 48.1 Mean age (year) Mean 30-50 30-50 (Minimum, Maximum) (14, 72) (17, 72) Mean years living in local address Mean 10-16 10-16 (Minimum, Maximum) (1-5, 20) (1-5,20) Mean Height (m) Mean 1.60 1.65 (Minimum, Maximum) (1.37, 2.9) (1.37, 2.01) Mean weight (kg) Mean 60 68 (Minimum, Maximum) (46, 80) (46, 80) The questionnaire covered several areas including demography (name, gender, age etc), years of living in the present building and individual environmental measures, taken to achieve comfort. Table 1. The questionnaire also included the traditional scale of thermal sensation (TSENS) and thermal preference. The TSENS scale was the ASHRAE seven points scale of cold (-3) cool (-2) slightly cool (-1) neutral (0), slightly warm (+1) warm (+2) and hot (+3). The three points thermal preference scale used asked if respondents preferred a change in their present environment, possible answers were "want warmer, "no change", want cooler.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1539 3.3 Measurement of indoor climate Instruments used to carry out the study include, the data logger, which measured air temperature and relative humidity. These parameters referred to as variables formed the primary measured data. Each respondent answered the questionnaire. Questionnaires were given to each of the families based on the number of adults (i.e. between the age of 16years and above), an average of four adults per house-hold. In each building, a data logger hung on the wall at a height of 1.5meters from the finished floor level in the sitting room, while a sensor, was hung in a bedroom, at the same height. The data loggers measure the variable in the sitting room, and those in the bedrooms whose records were registered through the sensors. The data loggers were calibrated to read off measurements every three hours beginning from 6am. This became necessary to help capture the maximum and minimum values of the variables. In every building also a single logger was hung in shaded wall outside for outdoor variables measurement. 3.3.2 Physical Measurements of Case Study Buildings Architectural details of the buildings used for study were made. The measurement included the site plan(s), floor plan(s), the sections and the elevations. The building s orientations, percentage of plot areas developed, landscaping, set backs from adjoing structures, fencing heights, building materials used, and the building finishings. The research considered also the

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1540 location of living spaces (zoning), room sizes and heights, windows (types and sizes), opening locations among other things. This became necessary in order to pin down the extent to which the architecture of the buildings contributed to the thermal performances of the buildings in the study area. 4.0 Results and Discussion 4.1 Environmental Parameter Data The measurement recorded the essential variables of air temperature, relative humidity and air velocity, necessary to determine the thermal comfort level in residences using thermal indices such as the Effective Temperature (ET), the Predictable Mean Vote (PMV) and the Operative Temperature (T o ). The statistical data on the environment is shown in Table 2 to 3 below. In both seasons the average temperature result of the buildings whose measurement exceeded 26 0 C was 32 0 C, with an average relative humidity of 80%. While those whose temperature measurement did not exceed the index range of (20-26 0 C) was 22 0 C, with an average humidity of 78%. The air velocity remained at an average of 0.1m/s which falls within the (ISOEN 773424, 1994) range for sedentary activities.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1541 Table 2: Statistical results of residences with temperature within 20-26 C Climatic Parameters Dry Season Rainy Season Ave Min Max Ave Min Max Indoor air Temperature 0 C 22.0 20.4 26 22.4 19.8 25.9 Outdoor air Temperature 0 C 26.1 24.0 28.4 26.7 23 27 Indoor Relative Humidity % 78 70 80 78 72 81 Outdoor Relative Humidity % 80 73 78 80 75 80 Indoor air Velocity m/s 0.1 0.`3 00 - - - Table 3: Statistical results of residences with temperature exceeding 26 C Climatic Parameters Dry Season Rainy Season Ave Min Max Ave Min Max Indoor air Temperature 0 C 32 30 34 32 29.8 33 Outdoor air Temperature 0 C 26.1 25 28 26.0 24 27 Indoor Relative Humidity % 80 77 82 80 79 84 Outdoor Relative Humidity % 78 73 78 78 74 80 Indoor air Velocity m/s 0.1 0.3 00 - - - The result revealed that out of the twenty seven (27) residences used for the thermal comfort test, nineteen (19) or 70.3% of it exceeded the index temperature range of (20-26 0 C), while eight (8) or 29.7% did not.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1542 4.2 Analysis of Votes The results of the questionnaire survey of the thermal perception of residential dwellers in the randomly selected residence include thermal sensation and preference. The equation that relates thermal condition to the seven point ASHRAE thermal sensation scale of -3 (cold), -2 (cool), -1 (slightly cool), 0 (neutral), +1 (slightly Warm), +2 (warm), +3 (hot) known as the Predicted Mean Vote (PMV) index was considered in the analysis. The neutral temperature is the temperature when the PMV = 0. The result revealed that majority (69.3%) of the respondents voted for hot sensation while 25.7% voted cool. The rest 5% were distributed among neutral (0), slightly warm (1), cold (-3) and slightly cool. The ASHRAE Standard 55 (2004) specified that acceptable thermal environment should have 80% of the occupants vote for the centre categories (-1, 0, +1). In this study only 25.7% of the respondents votes fell within the ASHRAE standard 55 (2004) category. This therefore confirms that most indoor thermal environments in the study area were not acceptable or were thermally uncomfortable. It was also observed that the 69.1% thermal respondents who voted hot sensation (discomfort) all came from the 70.3% residences whose experimental results exceeded the Effective Temperature (ET) index range of (20-26 0 C). This confirms that at temperatures exceeding 26 0 C most indoors of residential buildings in Umuahia urban environment become thermally uncomfortable.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1543 The result revealed that the average indoor temperature of residences, whose thermal measurement exceeded the ET index range of (20-26 0 C) was 32 0 C, while that of those that did not was 22 0 C. It was also discovered that the architecture of the buildings used for examination contributed to their result. It was found that the design and construction of all buildings whose thermal measurements exceeded the Effective Temperature (ET) index range of (20-26 0 C) i.e those that failed thermal comfort test did not consider the climate in Umuahia, hence, did not imbibe passive potentials needed to improve indoor air quality and thermal comfort in wet humid climates. Such design deficiencies is significant in the orientation of such buildings on site, zoning of living spaces, lack of shading devices. Poor choice of windows and window locations, use of concrete as major landscape material, absence of vegetation, deliberate abuse of building regulations, such as over development of plot areas, inadequate building setbacks, high fence walls etc. The reason for poor indoor air quality, and also abuse of building ethics was found to result from lack of engagement of professionals, as all the buildings that did not have acceptable thermal result had no architects. Cheividyankan (2007) inferred that because thermal comfort depends on the weather and the environment, it therefore becomes necessary for the design of the building to contribute 75% role in its comfort levels.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1544 Recommendations and Conclusion Since indoor thermal comfort is essential for the well being of the occupant (Akande 2010), it becomes important therefore for the architect and all environmental designers to target essentially energy efficient and sustainable architectural products. When buildings are designed to attain thermal comfort or when buildings need little or no mechanical energy support to do so, they are energy efficient and are sustainable (Alozie, 2014). The indoor thermal condition of residential buildings in Umuahia urban environment could therefore be improved, by adopting and improving on the design potentials of the residences, where thermal assessment remained with the Effective Temperature (ET) index of (20-26 0 C). Such thermal aids which are passive potentials include. (1) Orienting building properly on site. (2) The use of thermally friendly materials. (3) Adhering to building codes and regulations such as (a) Keeping to permitted percentage of development. (b) Observing minimum building set backs from adjoining structures. (c) Avoiding high fencing walls. (4) Landscaping; avoiding the covering of the entire site area in concrete. Planting grasses, shrubs and trees as landscape material for shades and to increase air movement, and heat absorbtion.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1545 (5) Zoning spaces in a manner that living areas are separated from the direct sun effect, and directed towards the lee ward direction of the prevailing wind. (6) Providing plot sizes that are proportionate to the users need. (7) Making good use of colors. (8) Good application of windows; such as a) Proper choice of windows, eg casement and louvered. b) The window opening direction such that adequate air quantity is harvested. c) Proper consideration of air inlets and outlets in the building. CONCLUSION There is no doubt that if the architect, and his design allies implement the aforementioned recommendations which should begin from design inception, and taken to practical completion of the new buildings they design and the old ones they refurbish, that the new products will provide acceptable indoor temperature. When this happens, energy will be saved, and a green and sustainable environment will emerge. Then product of design would live from cradle to cradle and not cradle to grave.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1546 References Adebayo, O.F, Ayuba P., Oyetola, S.A and Audu H.I (2013) Analysis of user s perception on How to Achieve Thermal Comnfort in Kano State Luxury Homes. Developing Country Studies 3 (2) Adunola A.O (2015); Evaluation of Thermal Comfort in Warm-Humid Nigerian City Using a Thermal Index. International Journal of Engineering and Technology No 3. 5(3) 126-133 Akande, O.K and Adebamowo M.A (2010); Indoor thermal Comfort for Residential Buildings in Hot-Dry climate of Nigeria. Proceedings of Conference: Adapting to change; New thinking on comfort. Cumberland lodge, Windsor, UK, 9-11 April 2010. London: Network for Comfort and Energy Use in Buildings, http://nceub.org.uk Alozie C. (2014): Sustainable Environment: Assessment of indoor thermal comfort in Residential Buildings in Abia State, Nigeria. Unpublished PhD thesis. Department of Architecture, Abia State University Uturu, Nigeria. ASHRAE 55:2004, Thermal Environment Conditions for Human Occupancy Auliciems, A. and de Dear, R.J. (1986a) "Air conditioning in a tropical climate: Impacts upon European residents in Darwin Australia. " International Journal of Biometeorology, Vol.30(3), pp.259-282. 10 Auliciems, A. and de Dear, R.J. (1986b) "Airconditioning in Australia - I Human thermal factors." Architectural Science Review, Vol.29 (3), pp.6775 Busch, J.F. (1990) "Thermal response to the Thai office environment", ASHRAE Transactions, Vol.96 (1), pp.859-872. Chenvidyakarn, T. (2007) Passive Design for Thermal Comfort in Hot Humid Climates. Journal of Architectural/Planning Research and Studies (5), 1-27. de Dear, R.J. and Auliciems, A. (1985) "Validation of the Predicted Mean Vote model of thermal comfort in six Australian field surveys". ASHRAE Transactions, Vol.91(2), pp. 452-468. de Dear, R.J. and Fountain,M.E. (1994) Field experiments on occupant comfort and office thermal environments in a hot-humid climate, ASHRAE Transactions 100 (2), pp. 457 475. Fanger, P.O. (1970) Thermal Comfort, Copenhagen, Danish Technical Press.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October-2015 1547 Fanger, O., (1970), Thermal Comfort Analysis and Applications in Environmental Engineering. New York, McGraw Hill. Givoni, B. (1976) Man, Climate and Architecture. Applied science publishers. Humphreys, M.A. (1975) Fields studies of thermal comfort compared and applied. Symposium on physiological requirements of the microclimate. 8-10 Sept. 1975 Prague BRE. Humphreys, M.A. (1978) Outdoor temperatures and comfort indoors. Bld Res. and Practice (Journal of CIB),6 (2),92 105. Hyde, R. (2000) Climate Responsive Design,London. E and F.N. Spoon. ISO EN7730 (1994), Moderate thermal environments Determination of the PMV and PPD indices and specification of the conditions for thermal comfort, International Standards Organization, Geneva. Koenigsberger, O.H., Ingersoll, T.G., Mayhew, A. and Szokolay, S.V. (1973) Manual of Tropical Housing and Building Part 1 Climatic Design, London, Longman Inc. Odim, O.O (2006): Passive Design as Ecological technique for Energy Efficient Buildings in Warm Humid Climates. Unpublished PHD Dissertation submitted to the faculty of Engineering and Environmental Sciences. Imo State University, Owerri Nigeria.