A3D MAX FAQ. How to model column base % fixity.

Similar documents
CADS A3D MAX. How to model shear walls

tab, specify the default connection type for the three connections tab, specify the design code and steel, bolt and weld types.

Portal frame PLASTIC DESIGN OF PORTAL FRAMES

DIN EN : (E)

NON-LINEAR FINITE ELEMENT ANALYSIS OF BASE-PLATE CONNECTIONS USED IN INDUSTRIAL PALLET RACK STRUCTURES

ACCOUNTING FOR SECOND ORDER EFFECTS DUE TO GEOMETRIC NONLINEARITY AS PER EUROCODE 2 AND EUROCODE 3 IN ETABS 2016 AND SAP2000 V19

Contents. Tables. Notation xii Latin upper case letters Latin lower case letters Greek upper case letters Greek lower case letters. Foreword.

Analysis and Design of Steel

STT+ Single-span Steel Beam. FRILO Software GmbH As of 04/07/2016

Example of a modelling review Roof truss

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

Multiframe Steel Codes

Tekla Structural Designer 2016

twelve rigid frames: compression & buckling ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2019 lecture

The Structural Engineer, Vol. 84 No. 21, 7th November 2006

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 4: Detailed Design of Portal Frames

midas Gen Release Note

Bridge articulation No. 1.04

BS EN :2004 EN :2004 (E)

Half through bridges No. 1.10

STS+ Single-span Steel Column. FRILO Software GmbH Version 2/2017 As of 07/11/2017

SOUTH AFRICAN NATIONAL STANDARD

The Open Construction and Building Technology Journal

Chapter. Steel Member Design

Behaviour of single storey frames with tapered web members accounting for manufacturing and assembling imperfections

HOW TO DESIGN CONCRETE STRUCTURES Columns

ECONOMIC ASPECTS OF PARTIAL STRENGTH CONNECTION IN THE DESIGN OF BRACED STEEL FRAME USING TRAPEZOID WEB PROFILED STEEL SECTIONS

COMPARISON OF MULTISTORY WALL RESULTS BETWEEN ADAPT-EDGE 1 AND ETABS 2 CONCRETE FRAME WITH SHEARWALLS

SAFE 2016 (v16.0.0) Release Notes

STEEL BUILDINGS IN EUROPE. Multi-storey Steel Buildings Part 9: Description of simple connection resistance calculator

SIMPLIFIED ESTIMATION OF CRITICAL TEMPERATURES OF PORTAL FRAMES IN FIRE

eleven rigid frames: compression & buckling ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2014 lecture

CSiBridge Version Release Notes

Verification of Welded eaves moment connection of open sections

Lessons learned: 3.2.Stability concepts

THE ROLE OF COMPOSITE JOINTS ON THE PERFORMANCE OF STEEL-FRAMED BUILDINGS IN FIRE. Prof. Khalifa S. Al-Jabri

DESIGN OF THE LINKED COLUMN FRAME STRUCTURAL SYSTEM A NEW ZEALAND APPLICATION

1. BS 5950: Structural use of steelwork in building Part 1: Code of practice for design of simple and continuous construction, BSI, 1990

ETABS 2016 Tutorial: Trusses

Structural Design of Pergola with Airfoil Louvers

Theory Composite Beam Design

Universal Beam and Universal Column sections subject to pure bending are all Class 3 semi-compact or better.

Equilibrium. Of a Rigid Body

Renovation of Buildings using Steel Technologies (ROBUST)

Finland. ASteel Software User Manual 2

SCAD Office Implementation of EUROCODES in steel structural design

Structural Engineering, Mechanics, and Materials. Preliminary Exam - Structural Design

STRUCTURAL ANALYSIS AND DESIGN OF STEEL CONNECTIONS USING CBFEM METHOD

Steel Designer. Windows Version 10. User Manual

PORTAL FRAMES 1.0 INTRODUCTION

Determination of the main characteristics of semi-rigid beam-to-column connections through numerical and experimental method

Distribution of Forces in Lateral Load Resisting Systems

MULTI-STOREY BUILDINGS - II

US Composites User Guide and Theoretical Background

Comparison of Sway Analysis of RC Frames using Cracked Moment of Inertia

THE DESİGN OF SLENDER RC COLUMNS

Tekla Structural Designer 2017

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND

five trusses & columns Trusses Trusses Trusses ancient (?) wood 1800 s analysis efficient long spans

Level 6 Graduate Diploma in Engineering Structural analysis

Concrete Design Guide

Types : Metal rockers, rollers or slides or merely rubber or laminated rubber, POT - PTFE

five trusses & columns APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

five trusses & columns APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2017 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

GLOBAL CONSTRUCTION SOFTWARE AND SERVICES CADS SMART PORTAL 3D RELEASE NOTES

Figure 1: a) Web side plate (WP) connected to column flange b) Flexible end plate connected to column web c) Beam supported on column cap plate

International Journal of Civil and Environmental Research Volume 02, Issue 01, Pages 1-9, Structural Analysis of Steel Beam under Fire Loading

5.2 Design Section Moment and Web Capacities

CE Advanced Structural Analysis. Lab 3 SAP2000 Beam and Frame Structures

STAAD.Pro V8i. STAAD.Pro V8i. STAAD.Pro V8i AD Features Affecting the Analysis and Design Engine

The Design and Construction of Cast-in- Place Concrete Axial Load Carrying Members including Columns and Walls (both Shearwalls and Tilt-Up Walls)

Multi storey buildings

SEISMIC PERFORMANCE OF MULTISTOREY STEEL FRAMES WITH STRAIN HARDENING FRICTION DAMPERS

CIVL473 Fundamentals of Steel Design

ADAPT-BUILDER : General Analysis/Design Options

MULTI STOREY BUILDINGS IV

OPTUM COMPUTATIONAL ENGINEERING FEATURES

MASONRY INSIGHTS. Finite Element Modeling, Analysis, and Design for Masonry. Introduction

LESSONS FROM A FULL SCALE FIRE TEST

SIMPLE INVESTIGATIONS OF TENSILE MEMBRANE ACTION IN COMPOSITE SLABS IN FIRE

SETTLEMENTS DUE TO TUNNEL CONSTRUCTION

ANALYSIS OF BUILDINGS WITH

SEISMIC BEHAVIOR AND DESIGN OF STEEL SHEAR CONNECTIONS WITH FLOOR SLABS

Jurnal Teknologi STEEL WEIGHT SAVING DEVELOPED FROM SEMI- CONTINUOUS CONSTRUCTION IN MULTI-STOREY BRACED STEEL FRAME BASED ON EURO-CODE 3.

Direct Analysis Method in Robot Structural Analysis Professional

5.2 Design values of material coefficient (BS EN :2005)

User Guide. for Eurocode Modules. Design+ Interface General Column Design Combined Wall Design Strip Foundation Design Design Parameters

COMPOSITE STRUCTURES PREPARED BY : SHAMILAH

CONNECTION STIFFNESS IMPLEMENTATION PROCEDURE

Design of Composite Bridges Use of BS 5400: Part 5: 1979

ST13 Shear Panel Stiffness. FRILO Software GmbH Version 2/2016 As of 23/06/2017

VARIOUS TYPES OF SLABS

STEEL DESIGNERS MANUAL

CE 160 SAP 2000 Notes for 2D Problems. Element and Joint Drawing Tools Global Coordinates of Cursor Position Units in View Window

The concept of statical determinacy

DEPARTMENT OF ARCHITECTURE ABUBAKAR TAFAWA BALEWA UNIVERSITY, BAUCHI ARC 615: ADVANCED BUILDING STRUCTURES LESSON 4: VECTOR ACTIVE STRUCTURAL SYSTEMS

LARSA 2000/4th Dimension: Staged Construction Analysis

Steel Truss FWS+ FRILO Software GmbH As of 21/06/2018

British Steel Fire Test3: Reference ABAQUS model using grillage representation for slab. Research Report

INTRODUCTION STANDARDS AND REGULATIONS

Transcription:

A3D MAX FAQ How to model column base % fixity.

1.0 Introduction BS 5950-1:2000 Section 5.1.3 gives recommendations for modelling base stiffness and capacity. The recommendations are given in terms of proportions or percentages of the stiffness and moment capacity of the supported column. There is no comparable guidance in Eurocode 3 (BS EN 1993-1-1) so BS 5950-1 could be considered non-conflicting complementary information (NCCI) in this respect. CADS A3D MAX provides tools for specifying partial elastic fixity in these terms as well as other options. CADS A3D MAX additionally provides for partial plastic moment capacity limits to be applied at member ends including the column to base connection. This is described in section 3 below. Four categories of base fixity are defined in BS 5950-1 section 5.1.3. These are discussed in 1.1 to 1.4 below because the code recommendations are not clear. Instructions for modelling are given in section 2 below. If you do not require to read the discussion but only want guidance on using the software go straight to section 2. This guide has been prepared with appropriate professional engineering logic and care but it has no official status and its interpretation and application is the responsibility of the user. 1.1 Fully pinned bases Clause 5.1.3.1 states that the stiffness of a base with a true pin or rocker connection should be taken as zero. Such connections are only rarely adopted for columns in practice because they can be hazardous during temporary erection conditions. However the `pinned base support is commonly adopted as a safe default for frame analysis and design purposes even though the connection is actually detailed with four anchor bolts providing at least some rotational restraint. When applying a support to a frame joint at the foot of a column it is recommended to use the `pinned base support type rather than the `pinned type. The former has rotational restraint about the vertical axis which avoids `spinning column type mechanisms when pins or plastic hinges are inserted at higher level. Fully pinned bases require no further discussion. 1.2 Nominally pinned base Clause 5.1.3.3 implicity authorises an inconsistent design model (a `fudge ) whereby the steel frame design may include some allowance for base fixity whilst the base itself is designed for zero moments applied by the frame. This is used mainly to `massage portal frame deflection calculations but sometimes also used in stability calculations. This means that two or three frame models have to be maintained to take advantage of this clause:- 1: For calculating moments and forces in the frame under ultimate limit state (ULS) load combinations, and for the design of the bases the column base supports are assumed pinned. 2: For calculating deflections under serviceability limit state (SLS) load combinations, the column base supports may be assumed to have partial fixity up to 20% of the column stiffness. 3: For checking frame stability or determining in-plane effective lengths under ULS load combinations, the column base supports may be assumed to have partial fixity up to 10% of the column stiffness. In many cases the third condition is not worth pursuing and so the above simplifies to ULS and base design pinned, SLS deflections up to 20% fixity. 1 A3D MAX How to model column base % fixity

The justification for this widely used option is that the beneficial details of construction (eg effects of floor slabs, cladding) are more complex and uncertain than can be readily included in normal analysis models and limited partial fixity is a reasonable indirect allowance for this. 1.3 Nominally rigid base Clause 5.1.3.2 (a) states that in global elastic analysis the stiffness of the base [ie column support] should be taken as equal to the stiffness of the column for all ultimate limit state calculations. However, in determining deflections under serviceability loads, the base may be treated as rigid [ie a fully fixed or encastré support] Clause 5.1.3.2 (b) states that in plastic global analysis any base moment capacity between zero and the plastic moment capacity of the column may be assumed, provided that the foundation is designed to resist a moment equal to this assumed moment capacity, together with the forces obtained from the analysis. In elastic-plastic global analysis the assumed base stiffness should be consistent with the assumed base moment capacity, but should not exceed the stiffness of the column. Careful reading of 5.1.3.2(b) reveals that it actually permits the full range of partial fixity from zero to 100% to be assumed. This subclause is therefore incorrectly placed under the heading Nominally rigid base and should really be either under 5.1.3.4 Nominally semi-rigid base or preferably a new category Semi-rigid bases since they are not nominal but must be consistently designed. It will also be noted that no recommendations are given for the design of the base / foundation itself. In order to make some sense of the above confusion, the following categories are suggested to achieve consistent design: 1.3.1 Nominally rigid bases 1: For calculating moments and forces in the frame under ultimate limit state (ULS) load combinations, the column base supports should be assumed to have partial fixity equal to 100% of the stiffness of the supported column. If plastic analysis is applied (as available in A3D MAX), the plastic resistance moment at the foot of the column should be 100% of the plastic resistance moment of the column itself. 2: For calculating deflections under serviceability limit state (SLS) load combinations, the column base supports may be assumed to be rigid [ie a fully fixed or encastré support]. However if deflections are not critical it may be simpler to use the same model as for the ULS with partial fixity equal to 100% of the stiffness of the supported column. 3: The base connection should be designed for the same ULS conditions as the frame. 4: The base/foundation should be designed for the same ULS and SLS conditions as the frame. 1.3.2 Semi-rigid bases The column base supports may be assumed to have any value of partial fixity between zero and 100% of the stiffness of the supported column. If plastic analysis is applied (as available in A3D MAX), the plastic resistance moment at the foot of the column should be the same percentage of the plastic resistance moment of the column itself as the % elastic fixity. The same fixity should be assumed for ULS and SLS load combinations and for base/foundation design. 2 A3D MAX How to model column base % fixity

1.4 Nominally semi-rigid base BS 5950-1 Clause 5.1.3.4 states: nominal base stiffness of up to 20% of the stiffness of the column may be assumed in elastic global analysis, provided that the foundation is designed for the moments and forces obtained from this analysis. It is difficult to see the point of this clause when clause 5.1.3.2(b) allows any percentage stiffness to be adopted with consistent design and clause 5.1.3.3 allows 20% fixity to be assumed for deflection calculations for nominally pinned bases. Pending possible clarification, this clause will be ignored for the remainder of this note and instead reference will be made to consistent semi-rigid design as described in 1.3.2 above in accordance with clause 5.1.3.2(b). 2 Modelling base fixity examples and inputs The principles discussed in the above interpretation of BS 5950-1 section 5.1.3 will be applied to the modest example frame shown below in fig1 as a `stick model. Fig 1: Example frame stick model with pinned base supports of which four are selected for editing. 2.1 Fully fixed (encastré) bases Under BS 5950-1, strictly speaking, this option is only applicable to serviceability (SLS) deflection load combinations. Select the relevant supports or joints as shown in red in fig 1. Use the Quick support tool to select the fixed base option from the Quick support selection pallete. The support symbols will change accordingly as shown in fig 3. 3 A3D MAX How to model column base % fixity

Fig 2: Quick support selection pallete. Alternatively right click on one of the selected joints and select Properties to open the Joint properties dialog. Open the Support tab and select Fixed from the Restraint type drop menu. The support symbols will change accordingly as shown in fig 3 Fig 3: Example frame with four supports changed to `fixed 2.2 Fully pinned bases. Reselect the four support joints. Use either Quick support or Properties to select the Pinned base option. The support symbols will change accordingly as shown in fig 1. Note that when applying a support to a frame joint at the foot of a column it is recommended to use the Pinned base support type rather than the Pinned type. The former has rotational restraint about the vertical axis which avoids `spinning column type mechanisms when pins or plastic hinges are inserted at higher level. The simple Pinned type should be used only when the base connection (or other support) definitely provides no restraint to rotation about the Y axis. 2.3 Partially fixed bases linear analysis 4 A3D MAX How to model column base % fixity

The following applies to any partial fixity in the normal range 0.10 to 1.00 x member stiffness [ie 10% to 100% of member stiffness] as long as second-order P-delta effects are not required in the columns in analysis. For P-delta analysis see below (2.4). First ensure that the relevant support joints are set to `fixed as shown in fig 3. If not, edit as noted in 2.1 above. Then select the relevant column members as shown in fig 4 and select the member direction symbols. Note that the column members in this instance all have end 1 at their bases so they can be treated together. If the directions are not consistent the members must be considered separately or they should be made consistent by using the Swap function in the Member editor. Fig 4: Example frame with four columns selected having fixed supports. Member direction symbols selected. 5 A3D MAX How to model column base % fixity

Fig 5: Partial fixity page for the four selected column members showing default values. Right click on one of the selected members and select Properties to open the Member attributes dialog. Select the Partial fixity tab as shown in fig 5. In the Partial fixity tab use the drop menu for end 1 (or the relevant end) to select the fixity condition Partial. There are three options for entering and displaying partial fixity (fixity of the end connection:- Proportion of full fixity Proportion of member stiffness Absolute stiffness The definitions of these are given in A3D MAX>Help>Analysing the structure>partial fixity. The derivation of the relationships between the above is given in the CADS website technical note A3D MAX Derivation of proportional partial fixity factors. The selection defaults to Proportion of member stiffness with value 0.50 corresponding to connection partial fixity 50% of member stiffness 4EI/L. By selecting the other options you can see the equivalent values. Note that the absolute or actual value of fixity (as used in the analysis) depends on the length of the member. If for any reason the member is split into sub-members as exemplified in fig 6, the selection of the sub-member immediately above the base may cause the absolute value of partial fixity to be calculated on its length rather than the relevant overall length resulting in an overestimate of connection stiffness. For this reason the software allows the overall design length of the member to be entered as shown in fig 5. If necessary different values may be entered for each principal axis and the default value based on the selected member length may be restored. For 20% member fixity edit 0.50 to 0.20. Selection of Absolute stiffness causes 27167 knm/radian and 9712 knm/radian to be displayed for the normal and lateral values for the column section 356x368 UKB 202 kg as shown in fig 7. 6 A3D MAX How to model column base % fixity

Fig 6: Example frame with some columns split into sub-members. Fig 7: Partial fixity page for the four selected column members showing absolute stiffness values corresponding to member proportional stiffness 0.20 with 356x368 UKB 202 kg column 4.0 m long. 7 A3D MAX How to model column base % fixity

Check calculation: K normal = 0.20 x 4 x E x I / L = 0.20 x 4 x 205 x 66261 x 10 4 /(4000 x 10 3 ) = 27167 knm/radian When the relevant end fixities have been entered for the columns the frame may be subjected to linear elastic analysis. If an analysis with Pdelta effects (second order geometric) is required the following section should be followed. 2.4 Partially fixed bases non linear analysis It will be noted that if analysis with Pdelta effects is requested and there are members with partial end fixity included in the model, the following message will be displayed in the Error log:- Analysis limitations: Pdelta effects are not considered for partially fixed members. This means that the stiffness of all the partially fixed members in the model will be calculated assuming linear elastic behaviour. For the majority of conventional building frames, the members sustaining significant compression forces are columns and bracings and it is important for these to be calculated taking into account Pdelta effects. Generally it does not matter that partially fixed beams should be calculated as linear because they normally sustain only insignificant axial forces. However in cases where beams are also part of a bracing system and so carring significant axial compression, the neglect of Pdelta effects can be significant. Fig 8: Example frame with four column supports selected. 8 A3D MAX How to model column base % fixity

Although A3D MAX cannot calculate the stability functions for partially fixed members, this limitation can be avoided for columns connected to base supports by applying the partial fixity to the support instead of to the column member. In such cases follow the procedure given in 2.3 above and make a note of the absolute values of fixity (eg as in fig 7). Then change the end condition to fixed (ie rigidly connected). Next select the support(s) to which the column member(s) are attached as shown in fig 8: Right click on any of the selected supports and select Properties to open the Joint properties dialog in which select the Support tab. Select New support to enable the support rotational stiffnesses to be edited. From the drop menus select Spring stiffness input for rotation about the X and Z axes and enter the required values. Fig 9 shows the inputs for this example. Note that the previously calculated value has been entered for rotation about the X axis but for rotation about the Z axis the support is assumed to rotate freely about the Z axis to avoid designing the connection and base for partial fixity in the XY plane. This is a user decision. Obviously any appropriate and valid value can be input providing that the subsequent design checks are satisfied. Fig 9: Support properties input page for the column supports selected in fig 8 after applying partial fixity to rotation about the X axis. 9 A3D MAX How to model column base % fixity

Fig 10: Portion of example frame after applying partial fixity to selected supports. Note that support properties are specified relative to the global axes so care must be taken when relating to the member axes and orientation. For columns with skew orientations it will be necessary to resolve member stiffnesses to the global axes. 3.0 Plastic analysis Fig 11: Plastic limits input page with default settings and drop menu selection. In addition to elastic partial fixity A3D MAX allows the input of limiting moments using the Member attributes dialog. Select the relevant members eg: the columns in fig 4. Right click on 10 A3D MAX How to model column base % fixity

any of the selected members and select Properties to open the Member attributes dialog then select the Plastic limits page. Fig 11 shows the default settings in this page for which refer to A3D MAX>Help>Creating and adding members>member attributes>plastic limits for general guidance. For the purposes of the current example it is sufficient to say that the lower part of the page may be used to define or imposed limits on the resistance moment of the connection at either end of the member. The options are: Unlimited. Specified resistance moment. This can be used if the connection resistance is known. Proportion of resistance moment. In this case we will specify proportional resistance moments consistent with the proportional elastic stiffness values adopted in 2.4 and fig 9 above as shown in fig 12. Fig 12: Plastic limits page after editing. Note that: `Constant is not selected because we are limiting moments at end 1 only. At end 2 the full resistance moment of the member section is assumed. At end 1, 20% of the resistance moment of the section is to be assumed as the connection resistance in the normal/major direction. The resistance moments are here assumed symmetrical. The minimum value is entered for proportional moment resistance in the lateral/minor direction but in fact any value could be entered because in 2.4 we specified free rotation in this direction so no moment is generated by the stiffness analysis. ----oo0oo---- 11 A3D MAX How to model column base % fixity