Energy Reduction Strategy Through 2020

Similar documents
Auburn Facilities Energy Reduction Plan

SUSTAINABILITY An Energy & Emissions Case Study

Implementing Low-Cost Energy Savings Projects & Conducting Energy Audits

Fifteen Year Plan for Energy Efficiency and Conservation Projects

ACCOMPLISHMENTS IN ENERGY REDUCTION EFFORTS AT THE ARCHITECT OF THE CAPITOL IDEA CAMPUS ENERGY CONFERENCE MARCH 8, 2018

Gerald R. Ford Museum

WAKE TECHNICAL COMMUNITY COLLEGE SUSTAINABLE ENERGY PLAN. Energy Plan

The baseline building system for compliance with Senate Bill 668 is defined by Appendix G,

Executive Order RP 49 Quarterly Energy Report for Texas A&M University September 2012

Energy Management Report

2017Annual Energy and Utilities Report

Energy Use and the University of Kentucky Info Sheet and Frequently Asked Questions

DTE Energy Commercial & Industrial Energy Optimization Program. Trade Ally Meeting. Guardian Plumbing & Heating January 20, 2011

ENERGY AS SERVICES COMPANY ESCO. Jamal E. Alostaz. Projects Engineer Al-Salem Johnson Controls

Xavier University of Louisiana

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

IFMA Central Pennsylvania Chapter August 20, 2014

Better By Design Energy Efficiency in Needham s Public Construction Projects

Grunenwald Science and Technology Building

Commercial & Industrial Energy Optimization Programs

Texas Tech University Energy Savings Program FY 2017 Update

ENERGY MODELING GUIDELINES. D. Section Building Automation and Control System Guidelines

1.0 EXECUTIVE SUMMARY

FirstEnergy s Pennsylvania Utilities. Energy Efficiency Programs for Business

Campus Annual Energy Use Report

Do-It-Yourself Energy Audit. Bob Furgeson, PE CEM CBCP GBE CEA Shive-Hattery Architects+Engineering

nmqwertyuiopasdfghjklzxcvbnmqwer tyuiopasdfghjklzxcvbnmqwertyuiopas dfghjklzxcvbnmqwertyuiopasdfghjklzx cvbnmqwertyuiopasdfghjklzxcvbnmq

Sustainable Building Operations & Upgrades

Arkansas Building Authority

LOGO. Trivium Level II Energy Audit

Energy Savings Performance Contracting

Energy Management Report

International Certification Scheme 1.0

Lambton Kent District School Board

Centre for Addiction and Mental Health Queen Street Campus Energy Conservation and Demand Management Plan

2017 STRATEGIC ENERGY AND WATER ANNUAL REPORT

County of Ventura General Services Agency Maintenance Division Energy Action Plan April Policy

Bryant University s Energy Guidelines for Sustainability

South Carolina Society for Hospital Engineers

DOE Best Practice Software Tools. Joseph Chappell Adam Roget

Conservation & Demand Management Plan

Prerequisite. prerequisite.

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

Cornell University Energy and Sustainability: ECI Campus Energy Metrics Fiscal Year 2014 Annual Analysis Purpose and Methodology. ECI Campus Summary:

Energy Assessment Report Clayville Elementary School DRAFT October George Washington Highway, Clayville, RI DRAFT

DCAS Energy Management. August 15, 2014 Ellen Ryan & Mike Dipple

Mechanical Systems Redesign Proposal. Thesis Proposal. Morton Hospital Expansion

Texas Tech University Energy Savings Program October 2010 Update

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

2014 ENERGY REPORT. Mark J. Ferguson, P.E. Campus Operations & Plant Manager

Cornell University Energy and Sustainability: ECI Campus Energy Metrics Fiscal Year 2015 Annual Analysis Purpose and Methodology. ECI Campus Summary:

05/14/2012 THE CRIME OF IMPROPER ENERGY MANAGEMENT AGENDA

Energy Reduction Programs: Understanding, Implementing & Delivering. PL Energy Services

ANALYSIS OF THE POTENTIAL ENERGY SAVINGS FOR 14 OFFICE BUILDINGS WITH VAV SYSTEMS

Appalachian State University

Deep Energy Retrofit Modeling and Cost Effectiveness Study: A Technical Policy Brief. January 2013

Cornell University Chilled Water Best Management Practices Program 2015 Annual Report

Colorado Mountain College: Sustainable Design Standards

Retrocommissioning Investigation Report

0B MAGNOLIA HALL. Scale: 1:110. Date: Feb Time: 7:40 pm. User: brady. 10 ft

Cornell University Energy and Sustainability: ECI Campus Energy Metrics Fiscal Year 2017 Annual Analysis Purpose and Methodology. ECI Campus Summary:

RETRO-COMMISSIONING: AN OWNER S LOOK AT THE TRUE COSTS AND RETURN ON INVESTMENT. Adam Renzi, PE

Duluth Energy Future Chapter 2: Investigating Zero-Energy Potential

how to read an energy model

The Duke Endowment. Duke Facilities Fall Campus Sustainability Summit. Facilities Discussion. September 14, Management

43% reduction in water use below code maximum 100% 100% 14% reduction in lighting power density. 56% of offices have thermal comfort controls 100%

A Key Component of Environmental Sustainability Efforts and a Source of Substantial Cost Savings for FCGU. Dr. Simeon Komisar

Energy Reduction in Hospitals

George Brown College Energy Conservation and Demand ManagementPlan

The owner is Oral Roberts University, while management and leasing is handled by Trinity Corporate Real Estate Advisors, LLC.

What s My Baseline? ASHRAE

PARK PLACE CASE STUDY VANCOUVER. Heat reclaim system expected to reduce steam consumption 80%, GHG emissions 68%

PROJECT HIGHLIGHTS 49% 74% 15% 51% 45% CLASS OF 1959 MEMORIAL CHAPEL HARVARD BUSINESS SCHOOL HARVARD UNIVERSITY

TECHNICAL ASSISTANCE STUDY IN SUPPORT OF NEW CONSTRUCTION PROGRAM

STRATEGIC ENERGY MANAGEMENT PLAN FOR ST. THOMAS ELGIN GENERAL HOSPITAL 2015

Local Government Energy Audit: Energy Audit Report

Energy Efficiency in Multi-Tenant Office Buildings

Required Treatment of District Thermal Energy in LEED-NC version 2.2 and LEED for Schools

EnergyPro Building Energy Analysis. Single-story School Building

Existing Earth and Ocean Sciences (EOS) Building

Bridgewater State College. Energy and Water Conservation Project

Summary of Greening of State Government Executive Orders

Hawaii Energy Policy Forum and Energy Industries Energy by Example Audit Awards Status Report October 2006-November 2007

C. of O. / P.A. Program bonded. Energy Conservation bonded Science Lab Upgrades bonded Minor Repairs hard dollar

Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)

Kaiserslautern Energy Efficiency Cost Optimization (EECO) 12 MAY 2011

EnergyPro Building Energy Analysis. Nine-story Office Building

ENERGY PERFORMANCE CONTRACTING IN AUSTRALIA Thailand ESCO Fair By: Tony Dorotic National Sales & Marketing Manager Energy Conservation Systems

ENERGY AND WATER CONSERVATION AND DEMAND MANAGEMENT PLAN

Energy Auditing for Schools. Maryland Energy Administration Eric Oliver, EMO Energy Solutions, LLC May 10, 2007

The Low Hanging Fruit Energy Efficient Lighting

Design Standard Sustainability

NEWMOA June 30, Fran Boucher LEED AP, Certified Energy Manager Senior Energy Engineer

April 16 th Linda Morrison Jesse Stanley

Teague Research Center

IFMA's How-To Guide Highlight: Getting Started on the Path to Sustainable Facility Management. Facility Engineering Associates

Optimizing Energy Use in a HealthCare Setting. Michael P. Della Barba Environmental Health & Engineering, Director of Commissioning

Center for Energy Education Laboratory

Emerging Technologies

Army Exceeds Energy Goal Ahead of Mandate (Actual Energy Reduction of 38% vs 30% and Achieved in 2010 vs 2015)

Transcription:

Through 2020 Revised: August 2017

Executive Summary Auburn University is a land, sea and space grant university established in 1856. The university consists of 11,629,000 square feet on 1,840 acres and serves 25,000 students annually. The Energy Reduction Plan was developed in 2012 by Auburn University Facilities Management to be more proactive and intentional in pursuit of energy reduction while supporting Auburn University s sustainability goals. The plan established nine goals and identified baseline years to improve upon while including campus growth. The goals focused on reducing consumption of gas, water, and electricity and reducing greenhouse gas. The original 2012 goals have been revised for this update of the. The strategy includes an assessment of past energy reduction efforts and areas identified with the greatest potential for energy reduction. Figure one provided below illustrates the total electricity and gas purchase since fiscal year 2008 and reflects the efforts to reduce purchased energy while the campus continues to grow. MMBTUs Purchased (YTD is 35,067 MMBTUs less than the average of the past three years) 1,400,000 1,200,000 1,000,000 994,424 1,037,403 1,237,535 1,273,240 1,238,847 1,273,834 1,235,514 1,205,016 1,230,716 12,000 10,000 8,000 MMBtu 800,000 600,000 400,000 588,255 6,000 4,000 200,000 2,000 0 FY08 FY09 FY10 FY11 FY12 FY13 FY14 FY15 FY16 FY17 YTD Electricity Gas Total Campus Sq Ft (thousands) 0 Figure 1: Total MMBtus of Electricity and Gas Purchased Page 1 of 4

Appendix A lists the goals for the. The first three goals focus on maintaining purchased electrical consumption and reducing gas and water consumption when compared to a 2010 baseline for all utilities. Purchased utility consumption caps were chosen to drive campus building utility efficiency while pushing toward renewable energy options. The second set of goals (goals 4 to 7) focus on improving the efficiency of utility use within our buildings. Goal number 8 focus on our largest consumer of electricity on campus, the chilled water plants which can move us further towards our electricity goals. Finally we want to ensure we know where all purchased gas and water is being consumed which can be achieved by installing meters at unmetered locations. Table 1 below provides a status update of our purchased consumption and utility efficiency through fiscal year 2016. FY16 YTD Consumption Targets (only Master Meters) Consumption Intensity FY16 Target % Difference from Target Baseline* 2015 % Change Electricity (kwh) Sept 193,070,691 186,597,875 3.47% 23.72 20.420-13.91% Gas (Mcf) Sept 520,554 558,526-6.80% 0.0710 0.0586-17.46% Water (kgals) Sept 346,707 391,902-11.53% 0.0619 0.0400-35.38% Table 1: Fiscal Year 2016 Year to Date Consumption Targets To update the plan we convened a group that included representatives from the Office of Sustainability, University Architect, Facilities Management Maintenance, Energy Management, Campus Services, and the University Engineer. In addition to our diverse group that reviewed the original plan, we also researched energy reduction strategies developed at peer institutions and the Department of Energy. Four main objectives were identified to categorize types of projects necessary to achieve our goals. The objectives include increasing efficiency of utility plants and University building systems. Increasing the use of renewable energy and operational best practices and implementing behavior change efforts to reduce utility consumptions. Building energy efficiency has continued to increase year over year resulting in a campus EUI of 17.5%. At the current pace, we should exceed the university EUI goal of 20% by 2020. Page 2 of 4

Based on our status in relation to our goals our greatest area of need is with reducing electrical consumption. While water consumption is currently exceeding our 2020 goal, efforts are still necessary to reduce water consumption in order to achieve our goal. Figure 2 below displays the actual electrical consumption versus our baseline target and shows electrical consumption will miss our goal by more than 10%. 210,000,000 205,000,000 Electric Actual vs. Target Goal: 186,597,875 kwh 206,452,214 200,000,000 195,000,000 192,178,211 193,070,691 190,000,000 188,616,371 188,651,830 185,000,000 180,000,000 184,200,627 182,308,521 175,000,000 170,000,000 2011 2012 2013 2014 2015 2016 Est. 2020 Total Figure 2: Actual Electric Consumption vs. Target Ongoing Energy Reduction Strategies Yearly Target Yearly Actual 2020 Goal Table 2 below provides an assessment of ongoing and completed energy reduction projects performed recently. The table includes savings achieved and estimated savings. Project Savings Lowder Hall AHU Control Upgrades $75,236 Wilmore Labs Mechanical Modifications $80,000 (est.) CWP-2 Optimization $116,630 (est.) Poultry and BERL Exhaust Fan Optimization $55,000 (est.) Parking Deck Lighting Retrofits $17,000 (est.) Table 2: Energy Reduction Projects Page 3 of 4

Existing building commissioning is one of our most cost effective approaches for reducing energy and utility consumption in campus buildings. Existing building commissioning includes identifying and repairing systems and equipment that are no longer operating per the original design documents. Additionally we implement optimized sequences of operation that have been successful in other buildings around campus as well as schedules developed with input from building occupants. Existing building commissioning results in a 5 to 15% reduction in total energy use. We need to re-commission buildings every 3 to 5 years in order to maintain energy savings. Due to the high percentage of buildings that utilize pneumatic controls energy reduction projects begin with upgrading the controls to direct digital controls (DDC) and integration to our campus building automation system. This upgrade improves visibility of the system and improves our ability for scheduling of HVAC systems and equipment when buildings are unoccupied. Other projects include the installation of variable frequency drives (VFD) on air handling unit fans and pumps. Installation of LED lights at the Campus Green Parking Deck has resulted in a 40% reduction in electrical consumption since installation in December 2016. Similar projects are an ideal way to contribute to our electricity consumption goal. Areas of Greatest Potential The largest consumer of electricity on campus is our chilled water plants as this is where nearly all cooling is generated for main campus and the vet school campus. Replacement of equipment that has reached end of life will increase chilled water plant efficiency. In addition, new control strategies coupled with upgraded variable speed equipment will maximize chilled water plant efficiencies. Further improvement of the chilled water plant performance can be made by maximizing building chilled water return temperature. The chilled water plants are also our largest consumer of water. This could be mitigated with the development of projects for the use of reclaimed water for cooling tower makeup water. After chilled water, plants the largest consumers of energy on campus are laboratory buildings. Upgrading constant volume laboratories to variable volume will result in reduced energy consumption and improved laboratory airflow controls. Other options include repair and replace inefficient HVAC equipment in campus buildings, including repair and replacement of insulation, ductwork and other related equipment. Increase the use of low flow plumbing fixtures and water closets in existing campus restrooms. As our campus continues to grow, we will need to invest in renewable energy production such as photovoltaic solar panels in order to achieve our purchased electricity goals. Page 4 of 4

Appendix A: Energy Reduction Objectives and Goals Appendix A

Objectives: Auburn University Facilities Management will work to reduce energy use, utility consumption, energy costs, and the university s carbon footprint by utilizing the following strategies to: 1. Increase efficiency of utility production and distribution systems. 2. Improve performance and efficiency of University building systems. 3. Increase use of energy saving, energy efficient, renewable energy technologies and operational best practices. 4. Increase energy awareness and energy conservation efforts by all AU students, faculty and staff. Auburn Facilities Management Energy Goals: 1. To maintain the overall consumption of purchased electricity (kwh) for main campus through 2020 at the same level as the 2010 baseline. This consumption will include future growth of the campus. 2. To reduce the overall consumption of purchased gas (MMBtu) for main campus a minimum of 5% by 2020 when compared to a 2010 baseline. This consumption will include future growth of the campus. 3. To reduce the overall consumption of purchased water (kgals) for the university a minimum of 5% by 2020 when compared to a 2010 baseline. This consumption will include future growth of the campus. 4. Reduce the university s energy intensity index (energy use per square foot) by 20% by 2020 from the 2006 baseline. 5. To reduce the overall average electricity energy intensity (kwh per square foot) of Auburn University facilities 15% by 2020 when compared to a 2010 baseline. 6. To reduce the overall average gas energy intensity (Mcf per square foot) of Auburn University facilities 20% by 2020 when compared to a 2010 baseline. 7. To reduce the overall average water use intensity (kgals per square foot) of Auburn University facilities 20% by 2020 when compared to a 2010 baseline. 8. To improve total chilled water plants efficiency 10% by 2020 when compared to a 2014 baseline. 9. To reduce unmetered use and system loss by 40% for domestic water and natural gas distribution systems by 2020 based on a 2012 baseline. Appendix A

Appendix B: Projects Revision 4: May 2017 Appendix B

Objective 1: Increased Efficiency of Utility Production and Distribution Systems 1.1. Develop and implement chilled water plant optimization projects. Projects include: Expand chilled water plant optimization programming to increase efficiencies. Installation of chilled water heat exchanger for free cooling. Convert chilled water plants to variable primary plants. Replace inefficient equipment at end of life with new more efficient equipment. 1.2. Develop and implement hot water plant optimization projects. Projects include: Improvement of boiler operations and staging to increase efficiencies. Continue to connect campus buildings to the central hot water system. Convert central steam system buildings to connect to central hot water system. 1.3. Reduce chilled water and hot water system leaks by continuing to identify and repair leaks in systems. 1.4. Focus on increasing chilled water return temperature in poor performing buildings. Develop list of poor performing buildings and investigate possible solutions to improve performance of those buildings. 1.5. Investigate projects and develop standards for new buildings for the installation and use of reclaim water systems. Reclaim water systems to include grey water systems, rainwater capture systems, condensate capture systems and waste water treatment systems to produce reclaimed water. 1.6. Develop plan and schedule for the replacement of Chilled Water Plant 1 with a new more efficient chilled water plant. 1.7. Increase the metering of utility systems and campus buildings. Develop a long range plan to increase the metering of utility systems and buildings to provide increased capability to monitor utility/energy usage. Appendix B

Objective 2: Improved Performance and Efficiency of University Building Systems 2.1. Develop projects for the repair and replacement of inefficient HVAC equipment in campus buildings. Projects to repair/replace insulation, ductwork and other related equipment and complete air handling systems replacements. Projects to include control retrofits and upgrades (i.e. pneumatic controls). 2.2. Increase the use of low flow plumbing fixtures by developing a list of buildings to target that need to be retrofitted with low flow plumbing fixtures to meet the current campus standards. 2.3. Expand current HVAC scheduling program across campus. Updated list of buildings that are scheduled is needed and then plan developed to install schedules in buildings not currently scheduled. The plan will include buildings that are not digitally controlled. 2.4. Expand lighting improvements in buildings which include controls, delamping and conversion to LED. Develop a plan for the conversion of interior lighting to LED and the addition of lighting controls for major areas that show benefit. Develop standards for improved lighting design to increase the use of energy savings technologies like LED and daylighting. 2.5. Develop landscaping standards and plans with plantings that require little water and improve the operation of building systems. 2.6. Implement projects to improve the operation of the Coliseum. 2.7. Expand the existing building commissioning program to increase the number of buildings commissioned or recommissioned each year. 2.8. Conduct steam trap surveys in buildings and central systems to identify needed repairs. Develop plans and schedules for the repair or replacement of identified steam traps. 2.9. Identify list of air compressors used across campus. Develop plan and projects to improve the operation, upgrade or removal of air compressors across campus. Develop standards for the purchase of new air compressors on campus. 2.10. Develop new standards with support from OIT for IT rooms. Standards should address requirements for power, back up, equipment and HVAC. 2.11. Develop comprehensive lab improvement plan. Plan to address existing lab needs for improvement in safety and energy consumption. Appendix B

Objective 2: Improved Performance and Efficiency of University Building Systems 2.12. Review and update design standards to ensure energy efficient designs of new and renovated buildings. Standards should address the use of life cycle cost analysis, energy models, new building commissioning and equipment efficiency standards. 2.13. Conduct energy audit of campus greenhouses to identify potential energy savings. 2.14. Develop projects to evaluate and improve building envelopes. 2.15. Improve the Preventive Maintenance Program for the AHUs, distributed chillers, coils, heat exchangers, pumps, boilers, and other equipment to improve equipment performance, efficiency and reliability. Increase the use of industry best practices and the use of predictive maintenance practices. Train Maintenance staff personnel as needed to achieve this goal. Appendix B

Objective 3: Increased Use of Energy Saving or Energy Efficient Technologies 3.1. Develop exterior lighting LED retrofit plan for campus. 3.2. Schedule regular thermal imaging of central plant distribution systems and roofs to identify issues. 3.3. Identify and install energy management analysis software to track energy usage and help identify potential energy reduction projects. 3.4. Develop training for technicians and campus users in the use of the building automation systems (Metasys). 3.5. Develop standards for new buildings and renovation projects to incorporate renewable energy technologies. Appendix B

Objective 4: Increase energy awareness and energy conservation efforts by all Faculty, Students and Staff. AU 4.1. Develop website to communicate campus and building energy usage to faculty, staff and students across campus. 4.2. Develop energy reduction competitions between different buildings, departments, dorms or schools/colleges to promote energy reductions. 4.3. Develop training/education topics for students, faculty and staff on energy management and reduction. 4.4. Develop standards for new building training to improve the level of training received by building occupants and building technicians. 4.5. Develop campus purchasing policy for Manage Print and a purchasing policy on purchasing energy star and EPEAT certified equipment. Appendix B