Fire Protection Underground Piping. ASCE Meeting 12/17/14 Columbia, SC

Similar documents
Underground Piping for Private Hydrants & Sprinkler Supply Line

WATER MAIN EXTENSION DESIGN REQUIREMENTS

DALTON FIRE DEPARTMENT 404 School Street Dalton, GA 30720

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

4A General Information A. Concept... 1 B. Conditions... 1

PART VII - WATER SYSTEM DESIGN CRITERIA

CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

TABLE OF CONTENTS PART III MINIMUM DESIGN STANDARDS Section 115 WATER DISTRIBUTION SYSTEM GENERAL SIZING LINES 115.

DUKE UNIVERSITY CONSTRUCTION STANDARDS

HYDRANT FLOW TESTING

WATER SERVICE APPLICATION Not to be used for Fire Service

Article 1008: FIRE PROTECTION REGULATIONS (Adopted 03/27/2012)

CHAPTER 8 WATER SUPPLY SYSTEM

TECHNICAL SPECIAL PROVISION FOR FINANCIAL PROJECT ID:

The Notice of Drafting was published in the State Register on September 28, 2012.

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

SECTION WASTEWATER FORCE MAINS

City of Middletown WATER & SEWER DEPARTMENT 82 Berlin Street Middletown, CT TEL: (860) FAX: (860)

SECTION FIRE HYDRANTS

BWSE-PA10 (08/18) Page 1 of 5 Project No. WCP

Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES

University of Central Florida Main Campus. Domestic Water. Service and Meter Installations Requirements. Issued January 26 th, 2017.

NFPA 24 May 2002 ROP Copyright 2001, NFPA

EXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS

Permit for Construction of an Extension to a JEA Drinking Water Distribution System and/or JEA Wastewater Collection/Transmission System

DEPARTMENT OF PUBLIC UTILITIES

All service lines shall conform to the following requirements:

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

RESIDENTIAL FIRE SERVICE METERS Addendum #1

Exhibit A FOX CHAPEL AUTHORITY STANDARD SPECIFICATIONS FOR MATERIALS AND INSTALLATION OF WATER MAINS

SECTION 1 GENERAL NOTES

SECTION WATER DISTRIBUTION SYSTEM TABLE OF CONTENTS

(Memorandum from Saccardi & Schiff, Inc., dated 11/01/2005)

SECTION 2100 WATER MAIN

WATER ORDINANCE TABLE OF CONTENTS

SECTION 401 WATER PIPE AND FITTINGS 2.2 POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS

SECTION PLUMBING SPECIALTIES

SECTION WATER DISTRIBUTION SYSTEM

F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it.

SECTION WASTEWATER FORCE MAINS

CHAPTER 5 WATER SYSTEM DESIGN STANDARDS

SECTION I. (Sub-Section 3) Water Systems Design Standards. 3.1 General Plans Preparation 3-1

SECTION WATER MAINS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

SERVICE LINES, METERS AND APPURTENANCES

Ivins City Standard Specifications for Design and Construction Part 2 Engineering and Design Standards

2015 UPC Chapter 6 Water Systems Part 1 RV

City of Columbia Engineering Regulations - 2-i

SUPPLEMENTAL MECHANICAL CORRECTION SHEET FOR SEWAGE EJECTORS AND SUMP PUMPS 2011 LAPC

CITY OF COLUMBIA ENGINEERING REGULATIONS PART 2: WATER DISTRIBUTION DESIGN STANDARDS TABLE OF CONTENTS

YAKIMA COUNTY, WASHINGTON. Special Provisions For Water Main Construction

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

PERMIT SUBMITTAL GUIDE FOR COMMERCIAL PROJECTS

Texas Tech University Health Sciences Campus - MSBII Supplemental Bid Instructions March 3, 2017

SECTION FACILITY SANITARY SEWERS

Everett Water Department Rules. & Regulations. Notification Page 2. Public Water Mains Page 2. Private Water Mains Page 2. Water Conservation Page 3

STANDARD DETAILS. Revised January Bonita Springs Utilities, Inc East Terry Street (239)

SECTION FIRE HYDRANTS

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

TOWN OF ROMULUS WATER DISTRICTS RULES AND REGULATIONS

With Power Comes Responsibility

Oregon Building Officials Association

1. Required Minimum Flow:

SECTION 2 Design Manual

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Section 12 Hydraulics.

City of Pekin- Zoning and Inspections Department 111 S. Capitol Street, Pekin, Illinois (309)

SECTION PUBLIC WATER SERVICE CONNECTIONS

Water Services Guidelines

Irrigation Tech II HYDRAULIC TROUBLESHOOTING

DRINKING WATER LINE INSTALLATION STANDARDS

CALAVERAS COUNTY WATER DISTRICT Ebbetts Pass Water System Reach 3A Pipeline Replacement Project CCWD CIP No ADDENDUM 2

STANDARD SPECIFICATIONS

If a new residence s electrical service is not located within 200 feet of existing

SECTION WATER UTILITIES

TRUMAN STATE UNIVERSITY OPHELIA PARRISH FINE ARTS CENTER ACOUSTICAL RENOVATIONS TABLE OF CONTENTS DIVISION 21 FIRE PROTECTION SYSTEM

SPECIAL SPECIFICATION 3504 Septic Tank System

Backflow Prevention:The Forefront of Responsible Irrigation

TECHNICAL DATA. Foam 190a. June 1, 2008

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

CISTERN & DRY-HYDRANTS

401 Sanitary Sewer System Design Criteria. The following additional design requirements shall also apply:

120 WATER DISTRIBUTION SYSTEMS

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

SITE-UTILITY SYSTEMS

COMMERCIAL PROJECT PLAN REVIEW PROCESS

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

Engineering Design Center. Standard Drawings. 1st Edition -January 2016

ROUTE 3 OLD WINTHROP ROAD PROJECT LOCATION I-95 PROJECT LOCATION WESTERN AVENUE NORTH BELFAST AVE.

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

Engineering Specifications

Engineering Specifications

SECTION NATURAL GAS DISTRIBUTION

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

CHINO VALLEY FIRE DISTRICT FIRE PROTECTION STANDARD

CULINARY WATER SYSTEMS

CURRENT NORTH LAS VEGAS ADDENDA

Lecture 11. WATER PUMPING EQUIPMENT and DEWATERING SYSTEM

SEWER SYSTEM DESIGN GUIDELINES

Transcription:

Fire Protection Underground Piping Columbia, SC

What We ll Cover Today 2 Applicable NFPA standards Shop Drawing Requirements State Fire Marshal s Review Sprinkler Act Fire Sprinkler System Specification Sheet Certificate of Compliance Why you get pulled Strategies to Ease the Pain

How Well Do You Know NFPA 24? 3 Answer True or False: 1. Fire Protection piping may not be smaller than 6 2. Water meters are not allowed on fire protection lines 3. Fire Department Connections must use National Standard Threads 4. Underground piping must be restrained with thrust blocks 5. All fire protection lines must be equipped with a Post Indicator Valve 6. The top of a PIV shall be set so the top is 40 inches above valve 7. Hydrants must be located at least 40 feet from the building protected 8. FP underground may not be run underneath a building 9. FP underground must always be flushed to provide a velocity of 10 ft/sec 10. FP underground is always tested to 200 psi

NFPA Standards 4 National Fire Protection Association 13 2010 Standard for the Installation of Sprinklers Systems Chapter 10 National Fire Protection Association 24 2010 Standard for the Installation of Private Fire Service Mains and Their Appurtenances Can you use the 2013 editions of these codes - Yes State Agencies - Must accept full compliance with current codes 1-34-40 Local AHJ May accept more current code using Chapter 1 of the IBC & IFC

NFPA 24 Key Definitions 5 AHJ Authority Having Jurisdiction an approval authority Private Fire Service Main (3.3.11) Pipe and its appurtenances on private property between a source of water and: the base of the system riser for water-based fire protection systems, the base elbow of private hydrants or monitor nozzles, the fire pump suction and discharge piping, and the inlet side of the check valve on a gravity or pressure tank

6 Typical Riser Typical Hydrant

7 Fire Pump Water tanks

8 Working Plans (4.1.3) - drawn to an indicated scale on sheets of uniform size, with a plan of each floor as applicable, and include applicable information: Name of owner Location, including street address Point of compass A graphic representation of the scale used on all plans Name and address of contractor Size and location of all water supplies Size and location of standpipe risers, hose outlets, hand hose, monitor nozzles, and related equipment

9 Working Plans (continued) The following items that pertain to private fire service mains: Size Length Location Weight Material Point of connection to city main Sizes, types, and locations of valves, valve indicators, regulators, meters, and valve pits Depth at which the top of the pipe is laid below grade Method of restraint

10 Working Plans (continued) The following items that pertain to hydrants: Size and location, including size and number of outlets and whether outlets are to be equipped with independent gate valves Whether hose houses and equipment are to be provided, and by whom Static and residual hydrants used in flow Method of restraint Size, location, and piping arrangement of fire department connections May also need to show the BFP flushing connection

11 Size of Fire Mains (5.2) When supplying a hydrant 6 inches is the minimum size When supplying fire protection systems Sized by hydraulic calculations or Same size as the riser Not as clear in NFPA 24 are Class I & III standpipes These must be 6 inches

12 Pressure-Regulating Devices and Meters (5.3 ) Only with AHJ permission Devices must be listed for Fire Protection Backflow Preventers are required by International Building Code & International Fire Code (903.3.5) NFPA 24 requires they must be listed for Fire Protection BFP shall be protected against mechanical damage where needed (6.5.2)

13 Fire Department Connections (5.9) AHJ may permit omission of the FDC FDC must be an approved type This is why some AHJs require the Stortz connections FDC shall use NH internal threaded swivel fitting(s) with an NH standard thread(s) NH = National Hose or National Standard Thread Local FDC does not use NH -> the AHJ shall designate the connection to be used FDC must have a check valve allows for removal of hoses FDC must have a ball drip to prevent freezing

14 Valves Controlling Water Supplies A listed underground gate valve equipped with a listed indicator post (PIV) An underground gate valve with approved roadway box and T-wrench may be accepted by the AHJ Provide one per source of water supply No shutoff valve is permitted in the FDC Acceptable valve locations Not less than 40 ft from the building Buildings less than 40 ft high PIV may be installed at least as far from the building as the height of the wall facing the PIV (outside collapse zone) Roadway Valve, Wall PIV, and pit valves may serve as control valve

15 Post Indicator Valve (PIV) Top of the post is 32-40 inches above the final grade Provisions for electronic supervision of valve Required through IBC & IFC for all required sprinkler systems Protected against mechanical damage where needed

16 Requires AHJ approval Commonly missed is not providing a T-Wrench

17 Fire Hydrant 18 to CL of outlet (7.3.3) Above finished grade Protection from mechanical damage (7.3.6) Show method of restraint Rod size, number, etc Thrust blocking with correct soil bearing factor Ball drip or weep hole and drain field not shown

18 How many Rods? What size? All underground metal must be coated (10.8.3.5) Sacrificial anode not permitted

The Start of a Bad Day! 19

20 If you Fire Department Connections is at the pit Be sure you provide a check valve And it s pointed the correct direction Provide a ball drip to drain the FDC Don t create a churn between the FDC & the hydrant NFPA 24 does not specify a minimum height above grade Annex A.5.9 does state the FDC shall not be less than 18 inched nor more than 4 ft above finished grade Remember the Fire Department may use a wrench to tighten the hose

BFP Flushing Connection in a Pit 21

22 BFP Flushing Connections Required by NFPA 13 & 25 Size and number Requirement is to flush the system demand Rule of Thumb - one 2.5 outlet per 250 GPM For Light Hazard systems a 2 main drain will handle it

23 Depth of cover Buried below the frost line (10.5.2) In SC 30 42 inches deep works Under driveways shall be a minimum depth of 3 ft (10.4.4) under railroad tracks shall be a minimum depth of 4 ft (10.4.5 )

24 Under building(s) Special precautions shall be taken for pipe run under buildings (10.6.2) Arching the foundation walls over the pipe Running pipe in covered trenches Providing valves to isolate sections of pipe under buildings Try to locate risers immediately inside an exterior wall Pipe joints shall not be located under foundation footings (10.4.5) Underground piping shall not be used as a grounding electrode for electrical systems (10.6.8)

25 Testing of underground piping Pressure test to 200 psi OR 50 psi over static pressure exceeding 150 psi Leave joints exposed Some leakage allowed Flush until clean @ 10 ft/sec, system demand plus hose, OR full flow of supply Require a UG Contractors Materials & Test Certificate

Sprinkler Act 40-10 26 40-10-230 (6) allows utility contractors to install underground piping 40-10-250 B requires a Fire Sprinkler System Specification Sheet be completed by an Engineer 40-10-260 B requires the engineer completing the FSSSS review the shop drawings and prepare a Certificate of Compliance NOT required for sealed drawings SFM want you to complete a COC so they don t have to review the plans

How You Get Pulled In 27 Utility contractors don t prepare plans They install from the engineers drawings No shop drawings = no SFM review or approval letter Sprinkler contractors will exclude underground from their scope They start 1 foot above finished floor So guess who the GC calls when they don t have the SFM approval Mr Engineer, why didn t you get your plans approved? Mr GC, it was not in my scope of work! Don t forget the missing 6 ft!

Ways to Avoid the Emergency 28 Be proactive and submit drawings to the SFM for review and approval EOR for the sprinkler system can assist with data for the FSSSS Add it as a service & bill for it Exclude SFM submission and approval from you scope of work May still get dragged in Require contractor to generate shop drawings This would require you to review the shop drawings and prepare a COC

Let s Review 29 Applicable NFPA standards Shop Drawing Requirements State Fire Marshal s Review Sprinkler Act Fire Sprinkler System Specification Sheet Certificate of Compliance Why you get pulled Strategies to Ease the Pain

Thank You for Attending! Columbia, SC