EDISON ELECTRIC INSTITUTE OCCUPATIONAL SAFETY & HEALTH COMMITTEE

Similar documents
Indoor Air Quality Monthly Testing Services, Corcoran Gallery of Art, th Street NW, Washington, DC December 2017

Analysis of VOCs & Formaldehyde

Vapor Intrusion: The Conference An Analytical Perspective

TN Tatem Middle School Indoor Air Quality Assessment September 2016

2/22/2008. Indoor Environmental (Air) Quality. Time Spent in Locations: Indoors & Outdoors. Why Should You Care About Indoor Air Quality?

Sampling and Analysis in Vapor Intrusion Investigations. Andy Rezendes, Technical Sales-Air Analysis

THE EFFECT OF DUCT CLEANING ON INDOOR AIR QUALITY IN OFFICE BUILDINGS

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

VOCs) For more information, see EPA's Substance Registry System on VOCs. Contents

BREATHE A LITTLE EASIER WITH TSI

360-INDOOR AIR QUALITY PROGRAM

New Developments in Thermal Desorption (TD) Tube & Canister Technologies for Collection & Analysis of Soil Gas

Indoor Environmental Quality Policy

Notes on Indoor Air Quality

OSHA Exposure Assessment Onshore and Offshore in the Deepwater Horizon Oil Spill Response

April 21, Dear Mike,

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Environment. Indoor Air Quality and Ventilation in Photographic Processing Facilities. Kodak s health, safety, and environmental

APPENDIX 13.2 A. Immunoassay. Fluorescent immunoassay. Enzyme immunoassay (ELISA) Radio immunoassay (RAST)

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

Indoor Air Quality (IAQ) Requirements

Contractor's Letter of Assurance

Air Monitoring Methodology DATE: 3 November 2008 TO: Singhvi, U.S. EPAIERT Work Assig THROUGH: FROM: BACKGROUND

INDOOR AIR QUALITY ASSESSMENT

Comprehensive Procedures for Collecting Environmental Samples for Culturing Bacillus anthracis Revised April 2002

Indoor Air Quality Assessments during Renovations at Waverly Elementary School Project #J (January 4, 12, 15, 25 and 29, 2018)

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

SOIL VAPOR INTRUSION Frequently Asked Questions

Course Objectives. INDUSTRIAL HYGIENE A Vital Component In Manufacturing Safety 3/24/14. This training course will cover

Chapter 14 Indoor Air Quality

Sick Building Syndrome. By MaryJo Franciskovich. Every Product we use begins as a part of the earth, whether plant, mineral, or animal.

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

Contractor's Letter of Assurance

1204 North Road (Rt. 117) Groton, Connecticut 06340

Indoor Air Quality Assessment Report

HAZ-SCANNER. Model HIM Complete Air Monitoring Station

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

AIR QUALITY ASSESSMENT FOR TAYLOR STANLEY MARKETING PTE LTD 71, TANNERY LANE #-7-07, CITY INDUSTRIAL BUILDING SINGAPORE

When Building a New Home

Sioutas Cascade Impactor

INDOOR AIR QUALITY PROGRAM

Industrial Hygiene for the Telecommunications Professional. John Malone, CSP, CIH Senior Safety Manager

NCCEH Mould Investigation Toolkit

Collection of Samples for Analysis of Volatile Organic Compounds (VOCs) in Indoor Air Using Sorbent Tubes. BAA Guide October 1, 2007

AirRenew Gypsum Board Products - Frequently Asked Questions

Meet today s webinar team

First Do No Harm: Are You Creating Health Problems in Your Homes? IBS 2015, Las Vegas, NV

Illinois Department of Public Health Guidelines for Indoor Air Quality

What s in the Air - Truths, Myths & Simple Strategies

Indoor Air Quality Solutions

Improve Schools Indoor Environment

Basic Industrial Hygiene Sampling Overview of Indoor Air Quality

The attached report is the result of a mold and bacterial assessment conducted at th Street, Franklin, Ohio on April 24 and 25, 2008.

SKC PMI Samplers. 25-mm pre-oiled disposable porous plastic disc; reduces particle bounce

Sioutas Cascade Impactor

INDOOR AIR QUALITY ASSESSMENT. Department of Developmental Services & Department of Mental Health Service Center 35 Nagog Park Acton, Massachusetts

TEXAS FACILITIES COMMISSION Edit Date: 4/13/2012 ARCHITECTURAL/ENGINEERING GUIDELINES

Visible emissions were not observed in the school in the vicinity of the construction containment.

A measurement on chemicals emitted from computers and printers using test chamber method

INDOOR AIR QUALITY TESTING AT CARLISLE COUNTY ELEMENTARY SCHOOL

According to our research and study most occupant complaints relating to IAQ are attributable to the following factors:

Green Building Practice Summary 03/17/2011

Validation of Sulfur Dioxide Using. SKC UME x 200 Passive Sampler Cat. No Page 1 of 14 Publication 1781 Rev 1607

Fire & Smoke VOCs Sampling Plan & Collection

The 411 on emitting materials Designing Healthy Interiors A. Costello, P.E., LEED-AP

LEED Best Practices Save $$$

The Leader in Performance Indoor Air Quality Measurements

Storage Environments: Monitoring & Control. Howard Wellman Maryland Archaeological Conservation Laboratory

The Leader in Performance Indoor Air Quality Measurements

Health & Public Safety Management

AIR. Ambient, Indoor, Workplace Air and Stack Emissions Proficiency Testing Scheme Version 1 Issue Date 18/09/2018

INTERPRETING MICROBIAL MEASUREMENT AND ANALYSIS

Continental Aluminum Exposure Investigation Executive Summary

Improving Indoor Air Quality. Presented by Theo Cole, EIT

February 21, Mold Assessment. 400 East Avenue, Warwick, Rhode Island. Dear Mr. McCabe:

Interior surface materials as sources of indoor hygiene defects

MOLD REMEDIATION PROCEDURES AT A NEW JERSEY ELEMENTARY SCHOOL

SECTION INDOOR AIR QUALITY MANAGEMENT PLAN. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Dalrymple Consulting, Inc. "Your Environmental Engineering Source" 7841 SW 1 i b Street, Topeka, Kansas (785) FAX (785)

ANILINE, o-toluidine, AND NITROBENZENE 2017

SECTION SUSTAINABLE DESIGN REQUIREMENTS LEED FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS

Table of Contents. C. Recommended Remediation Firms: upon request

Washington State Department of Health Division of Environmental Health

Mold Remediation. 1. Purpose and Requirements. 2. Scope. 3. General Responsibilities HS13_IAQ_SOP_002. Occupational Safety & Health

Rowan University Department of Environmental Health and Safety. A Brief Overview for Building Maintenance

Mold Remediation. Containment guidelines: based on the size of the infected area.

Indoor Air Quality Tools for Schools

Indoor Air Pollution. Indoor air pollution can be an even greater health threat than outdoor air pollution. Common pollutants often

Do European standards for indoor air quality take into account outdoor air quality? Professor Bjarne W. Olesen, PhD, Department of Civil Engineering

MATERIAL SAFETY DATA SHEET

Indoor Air Quality Program

Quality and Performance in Construction Delivered by Trusted expertise for the product manufacturing sector

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

"INDOOR AIR QUALITY"

EOH 2504, Principals of Environmental Exposure: Lecture 12, Assessment of Exposures to Airborne Contaminants

Indoor Air Quality Grade Level 4-5

Air Pollution. tutorial by Paul Rich. Brooks/Cole Publishing Company / ITP

MICROBIO BIOAEROSOL SAMPLING

Indoor Air Pollution

Determination of Clearance Criteria Following Mercury Decontamination Projects

Transcription:

EDISON ELECTRIC INSTITUTE OCCUPATIONAL SAFETY & HEALTH COMMITTEE 1

TOOLS OF THE TRADE FOR EVALUATING INDOOR AIR QUALITY Debbie Dietrich, CIH SKC Inc. 2

BUT SINCE WE ARE IN THE SUPERBOWL CITY. A BETTER TITLE: WHO DAT DOING AIR SAMPLING?

THE CHALLENGES UNIQUE TO IAQ EVALUATIONS 1. Building occupants may complain of health effects at contaminant levels far below the OSHA limits. 2. NIOSH/OSHA sampling methods may not be able to detect the lower levels found. 3. Once you get the sampling results, it is difficult to interpret the data. 4. Building comfort factors may confound the investigation of air quality. 4

STEP UP TO THE CHALLENGE In the overall costs of operating a commercial building, people costs are by far the highest. If the workforce is absent, sick, or unproductive, the OSHA limits will be irrelevant to management. So health and safety professionals will serve both the building occupants and the building owner/employer by seriously addressing the indoor environmental quality concerns. 5

OVERCOMING THE CHALLENGES: RESPONDING TO COMPLAINTS THE FIRST STEP Before embarking on a program of air measurements, survey both the area and the people involved in the complaint. Use this time for information gathering. Look around. Listen. GATHER CRITICAL INFO Complaint vs noncomplaint areas. Date when problem was first noted. Days or times when problem is noted more and less. Seek input so you can formulate a hypothesis on the root cause of the complaints. 6

OVERCOMING THE CHALLENGES: SAMPLING METHODS NIOSH/OSHA sampling and analytical methods are designed for industrial workplace applications. If you want to use these methods to measure lower levels, talk to your analytical laboratory for advice prior to sampling. For gases/vapors, NIOSH suggests you sample a LONGER TIME rather than a higher flow rate to collect more contaminant onto the media. 7

OVERCOMING THE CHALLENGES: SAMPLING METHODS In 1990, U.S. EPA published a compendium of methods for the collection of indoor air pollutants. These methods are designed to collect typical indoor contaminants at the lower levels found in this environment. These methods can be found on the California EPA website at www.arb.ca.gov/research/indoor/methods.htm 8

OVERCOMING THE CHALLENGES: DATA INTERPRETATION OSHA PELs or ACGIH TLVs will not typically be useful in evaluating indoor air measurements. Data interpretation may involve comparison of results: complaint vs non-complaint areas; indoor vs outdoor; test area vs control area. Guidelines from professional associations or peer-reviewed journals are also useful and will be given in this presentation. 9

OVERCOMING THE CHALLENGES: CONFOUNDING FACTORS Even if the complaint seems at first to be related to air contaminants, also consider building comfort factors that may cause similar health effects. Building comfort factors include illumination levels, glare, temperature, relative humidity, and noise. 10

COMMON INDOOR AIR CONTAMINANTS SOURCES, SAMPLING METHODS, AND GUIDELINES FOR DATA INTERPRETATION 11

TARGET: MOLD NOT SUCH A FUN-GI 12

MOLD: A MOISTURE PROBLEM Mold can grow on any substance including wood, paper, carpet, and foods providing moisture is present. Most microorganisms can thrive in the temperature range and on the nutrient sources in buildings. 13

INVESTIGATING MOLD: MOISTURE INDICATORS Water marks on ceiling tiles and other surfaces Visual presence of mold Musty smell of microbial VOCs White, powdery or crystalline substance of the surface of concrete, plaster and masonry which are soluble salts dissolved from the building materials 14

INVESTIGATING MOLD: MOISTURE METERS Used to survey moisture in any nonconductive porous material to which the probes can be applied. Ceiling Tiles Gypsum Board Carpeting Wood Plaster Concrete 15

INVESTIGATING MOLD: MOISTURE METERS ECONOMY MODEL Operates by measuring the electrical conductance between two probes inserted into the material to be tested. Useful for construction or renovation projects or other situations when the test surface can be punctured by the probes. SKC 751-6060 16

INVESTIGATING MOLD: MOISTURE METERS PINLESS MODEL Measures resistance between two lowfrequency signals transmitted from conductive pads without the need for insertion into the test material. Specialty models available for testing concrete. SKC 759-101/102 17

DATA INTERPRETATION MOISTURE METERS Moisture levels can be compared from wall to wall to determine where moisture intrusion is occurring. Once the location of the moisture is found, an investigation can be made as to the cause and a control strategy can be developed. 18

DATA INTERPRETATION MOISTURE METERS The Western Wood Products Association (WWPA) has prepared a technical guide on preventing and controlling mold in lumber. See www.wwpa.org/moldff2.htm. WWPA recommends that the moisture content of the wood be kept below 20%. 19

DATA INTERPRETATION MOISTURE METERS Greenguard Environmental Institute (GEI) has received ANSI approval for a standard covering the management of moisture (and mold growth) during building construction. See www.greenguard.org 20

SAMPLING FOR MOLD WHY AND HOW Sampling is done: To test your hypothesis on the cause of the problem To positively confirm the presence of mold To identify the type of mold (genus/species) To confirm the effectiveness of mold decontamination. Sampling may include: Bulk samples Surface samples Air samples Followed by analysis at a qualified environmental microbiology laboratory. 21

BULK SAMPLING FOR MOLD Portions of materials in the building can be tested for mold or other biological contaminants. Typical test materials include sections of wallboard/wallpaper, carpet pieces, return-air filters, duct lining, and settled dust. These are very useful as air sampling may miss some mold contaminants due to temporal variations in spore release. 22

BULK SAMPLING FOR MOLD Portions of the test material are typically placed in a sealable plastic bag for transport to the lab. In some cases, sterile jars for dry items or sterile bottles for water samples may be required. Settled dust can be collected using conventional vacuum cleaners and a new vacuum cleaner bag for each sample. 23

SURFACE SAMPLING FOR MOLD MICROVACUUM CASSETTES Carpeting is an effective reservoir for fungal spores and sampling this surface can reveal the history of mold in the building. To sample fungal spores in carpeting, a vacuum-style cassette is available with a 0.45 um polycarbonate filter loaded into a 3-piece styrene cassette with 2-inch tubing nozzle. Sample at flows up to 16 L/min to vacuum a defined area. Work the inlet tube as deep as possible into the carpeting to collect a good sample of the dust. 24

CARPET SAMPLING KIT SKC 225-9540 25

DATA INTERPRETATION CARPET SAMPLES An 2003 AIHCE paper by MidWest Microbiology gave some numerical guidelines for fungal spores on surfaces like carpet using microvacuum cassettes: Normal- <5,000/1000 cm 2 Borderline- 25,000/1000 cm 2 Elevated- 75,000/1000 cm 2 26

SURFACE SAMPLING FOR MOLD STERILE WIPES A swab or filter wetted with sterile water or wash solution is used to wipe a specified area. Typically, the swab is then used to inoculate an agar plate for growth culture. SKC 225-2402 27

DATA INTERPRETATION SWAB SAMPLES The November 2001 AIHA Synergist guidelines for fungal spores in swab samples: Normal: <10,000 cfu/in 2 or <1,500 cfu/cm 2 Probable Contamination: >10,000 cfu/in 2 or >1,500 cfu/cm 2 28

SURFACE SAMPLING FOR MOLD LIFT TAPE Collected by placing clear adhesive or packing tape or commercially available sampling strips onto a surface and removing it with slow, steady force Following collection, the tape is attached to glass slides and examined using light microscopy. 29

SURFACE SAMPLING FOR MOLD LIFT TAPE ON A SLIDE Flexible plastic microscopic slides with a sticky adhesive sample area can be used like lift tape. Press on the test surface, place the slide in the provided mailer and send to a qualified laboratory. Stick-to-It Slides SKC 225-9808/9 30

DATA INTERPRETATION LIFT TAPE SAMPLES The November 2001 AIHA Synergist guidelines for fungal spores in tape samples: Normal: No significant fungal material or biomass; 1-5% spores Probable Contamination: 25-100% spores 31

AIR SAMPLING FOR MOLD: WHY AND HOW Like with chemical sampling, air sampling for mold or other biological contaminants is done for the purpose of evaluating actual human exposures. Air sampling for mold involves the use of: Impactors Filters or Liquid-based (impingertype) devices 32

AIR SAMPLING FOR MOLD SPORETRAP CASSETTES Easy, inexpensive screening device. Use with a pump at 15-30 L/min for up to 10 minutes. Spores impact onto a microscopic slide with a sticky surface. Slide is stained and analyzed microscopically. 33

VERSATRAP CASSETTES SKC 225-9820/1 34

AIR SAMPLING PUMPS FOR USE WITH SPORETRAPS Constant flows from 10-30 L/min User selectable sampling times Lithium-ion battery powered up to 4 hrs Indefinite run time from AC adapter Optional sampling wand SKC 228-9530 35

DATA INTERPRETATION SPORE TRAPS Spore trap analysis will provide the total number of spores and the genus of the spores found. This information can be used to compare the complaint area to non-complaint areas of the building and to the outdoors. The genus of the spores should be similar inside and out. The numbers should be lower inside. 36

DATA INTERPRETATION SPORE TRAPS November 2001 AIHA Synergist guidelines for air samples: Residential Buildings: Normal: <5,000 spores/m 3 Probable Contamination: >10,000 spores/m 3 Commercial Buildings: Normal: <2,500 spores/m 3 Probable Contamination: >10,000 spores/m 3 37

AIR SAMPLING FOR MOLD VIABLE CASCADE IMPACTOR Specified in NIOSH Methods 0800 and 0801 Used with a pump at 28.3 L/min for typical sample times of 2-5 minutes Mold impacts onto growth medium (agar). Agar plates are shipped to a microbiological laboratory for growth and culture. SKC 225-9610/11 38

BIOSTAGE SAMPLER PREPARATION 39

BIOSTAGE WITH SKC QUICKTAKE 30 PUMP Reminder: Must be cleaned with isopropyl alcohol before each use. Evaluate blank samples of agar plates. 40

AIR SAMPLING FOR MOLD FILTERS Collection of microorganisms is achieved by passage of air through a porous medium, typically a membrane filter. Polycarbonate, mixed cellulose ester, or polyvinyl chloride filters may be used depending upon the application. Gelatin filters will help to maintain viability by minimizing dehydration of the spores. 41

AIR SAMPLING FOR VIABLE MOLD USING FILTERS Filters, support pads and cassettes should be sterile. Samples are collected with a portable pump at 1-4 L/min for 5-30 minutes. After sampling, the material collected on the filters is inoculated onto agar plates. 42

AIR SAMPLING FOR MOLD COLLECTION INTO LIQUID Pumps are used to pull mold spores into glass impingers filled with a liquid collection medium, typically a dilute buffer solution or mineral oil. Portions of the collection liquid can be placed onto nutrient agar and incubated or analyzed using other methods. Biosampler SKC 225-9595 ADVANTAGE: 8-hr sampling 43

DATA INTERPRETATION VIABLE AIR SAMPLES November 2001 AIHA Synergist guidelines: Residential Buildings: Normal: <500 cfu/m 3 Probable Contamination: >1,000 cfu/m 3 Commercial Buildings: Normal: <250 cfu/m 3 Probable Contamination: >1,000 cfu/m 3 44

TARGET: FORMALDEHYDE 45

INDOOR SOURCES OF FORMALDEHYDE Formaldehyde is frequently used as a preservative and adhesive. Formaldehyde gas can be released indoors from particle board, veneered or laminated furniture and cabinets, paneling, permanent press fabrics, and drapes. Formaldehyde is a strong irritant that can cause burning in the eyes, nose, and throat. As of 2004, the IARC classified formaldehyde as a carcinogen. 46

AIR SAMPLING FOR FORMALDEHYDE USING SORBENT TUBES 2,4- DNPH-treated silica gel tube following EPA Method IP-6A, EPA TO-11A, or NIOSH 2016. SKC 226-119/120 This sorbent tube can detect lower levels than the OSHA workplace method. 47

AIR SAMPLING FOR FORMALDEHYDE USING PASSIVE SAMPLERS UMEX 100 Uses 2,4-DNPH chemistry following OSHA Method 1007 and EPA Method IP-6C. Can detect down to 2 ppb Validated sampling rates for 24-hours or 7-day sampling SKC 500-100 48

DATA INTERPRETATION FORMALDEHYDE Indoor Air Quality Association Inc. (IAQA) recommends an indoor air limit of 50 ppb. U.S. Green Building Council recommends an indoor air limit of 27 ppb in their LEED 2009 rating system for new construction and major renovations. 49

TARGET: PESTICIDES 50

SOURCES OF PESTICIDES INDOORS Indoor pesticide exposures may result from pesticides applied indoors or from pesticides inadvertently brought in from the outdoors on shoes. Pesticides may accumulate on carpeting and other flooring materials and become an exposure source. 51

AIR SAMPLING FOR PESTICIDES OSHA VERSATILE SAMPLER (OVS) Sorbent tubes with an internal pre-filter and 2 layers of XAD-2 sorbent. Simultaneously collect pesticide vapors and aerosols following various OSHA/NIOSH methods. SKC 226-30-16/226-58 52

AIR SAMPLING FOR PESTICIDES PUF TUBES Tubes containing specially prepared polyurethane foam are used at flows from 1-5 L/min for 4-24 hours for pesticide measurements following EPA Methods IP-8 and TO-10A. SKC 226-92 53

DATA INTERPRETATION PESTICIDES The Agency for Toxic Substances and Disease Registry has published Minimal Risk Levels (MRLs) for various compounds including pesticides. See the complete list of MRLs at http://www.atsdr.cdc.gov/mrls/index.html 54

TARGET: VOLATILE ORGANIC COMPOUNDS (VOCs) 55

SOURCES OF VOCs Many common cleaning and household products contain solvents that can result in airborne concentration of a variety of VOCs that can cause problems for some people. Furniture cleaners Wood preservatives Carpet shampoos Disinfectants Cleansers Paint/Paint strippers Moth repellants Hobby supplies 56

TOP 10 VOCs MEASURED IN OFFICE BUILDINGS Toluene Acetone n-hexane 1,1,1- Trichloroethane Chloromethane Benzene Ethanol 2-Propanol Dichlorodifluoromethane m- and p-xylenes 57

SCREENING DEVICES FOR VOCs PHOTOIONIZATION DETECTORS (PIDs) The new ppbrae 3000 can detect VOCs down to 1 ppb. These are good survey tools that can be used like a Geiger counter to ID vapor sources. SKC 730-C110-000 58

AIR SAMPLING FOR VOCs USING CANISTERS The canister vacuum pulls the air sample without the use of batteries or AC power. Flow restrictors maintain flow stability over the desired time period from <1 minute to 12 hours. Some labs will supply canisters with their analysis service following EPA Methods IP-1A and TO-15. SKC 228-Series 59

AIR SAMPLING FOR VOCs USING SORBENT TUBES Specialty tubes designed for thermal desorption are required to measure the low levels found in indoor air. These tubes are purged with heat by the laboratory and must be used within 30 days. After sample collection, the tubes are analyzed following EPA Methods IP-1B or TO-17. Thermal desorption tubes are stainless steel or glass open-ended tubes to allow for thermal purging before/after sampling. 60

AIR SAMPLING FOR VOCs USING PASSIVE SAMPLERS Standard IH organic vapor badges may be suitable to collect 24-hour samples of some VOCs at ppb levels in indoor air. Specialty passive samplers that utilize thermal desorption methods are better options for sub-ppb level measurements of VOCs. SKC 590- Series Ultra Samplers SKC 575- Series Samplers 61

DATA INTERPRETATION VOCs Indoor Air Quality Association Inc. (IAQA) recommends an indoor air limit of 3 mg/m 3 as total VOCs. U.S. Green Building Council recommends an indoor air limit of 500 µg/m 3 in their LEED 2009 rating system for new construction and major renovations. 62

TARGET: COMBUSTION POLLUTANTS 63

SOURCES OF COMBUSTION POLLUTANTS Any device that burns fuel can introduce a combustion pollutant into the indoor environment if not properly vented. Common sources include gas stoves and ovens, space heaters, automobiles in adjacent garages, and burning, welding, and soldering activities. Combustion pollutants include carbon monoxide, carbon dioxide, nitrogen dioxide, sulfur dioxide, and particulates. 64

AIR MONITORING FOR GASEOUS COMBUSTION POLLUTANTS Reminder: Check the measuring range of direct-reading instruments. 65

AIR SAMPLING FOR GASEOUS COMBUSTION POLLUTANTS SORBENT TUBES Sorbent sample tubes containing specially treated sorbents are available for: Sulfur Dioxide by OSHA Method ID 200 Nitrogen Dioxide by NIOSH Method 6014 or OSHA ID 182 PASSIVE SAMPLERS A new passive sampler utilizing a chemically treated filter paper technology is now available for measurements of SO 2 and NO 2. It can detect 0.05 ppm NO 2 with 24-hr sample time. 66

DATA INTERPRETATION CARBON MONOXIDE Indoor Air Quality Association Inc. (IAQA) recommends an indoor air limit of 9 ppm. U.S. Green Building Council recommends an indoor air limit of 9 ppm and no greater than 2 ppm above outdoor levels in their LEED 2009 rating system for new construction and major renovations. 67

DATA INTERPRETATION NITROGEN DIOXIDE WHO Indoor Air Guideline 0.08 ppm for 24 hours 0.21 ppm for 1 hour Health Canada Indoor Air Guideline 0.25 ppm for 1 hour 68

DIRECT-READING INSTRUMENTS FOR PARTICULATES EPAM-5000 Measures particulates as PM10, PM2.5, or PM1 using light scattering technology with various sampling heads. Has internal sampling pump for concurrent gravimetric samples using a 47-mm filter. SKC Cat. No. 770-201/3 69

AIR SAMPLING METHODS FOR PARTICULATES EPA Method IP-10A specifies the use of sizespecific Impactors and filters for PM10/PM2.5 followed by gravimetric analysis. The Personal Modular Impactor (PMI) meets the requirements this method using flows of 3 L/min. SKC 225-350/352 70

SAMPLING PUMPS: NOW WITH LI-ION POWER AirChek XR5000 Up to 5 L/min for 20+ hours Leland Legacy Up to 10+ L/min for 20+ hours 71

DATA INTERPRETATION PARTICULATES Both the IAQA and the USGBC have an indoor air guideline for particulates of 50 ug/m 3. 72

TARGET: COMFORT CONTROL AND BUILDING PARMETERS 73

ILLUMINATION LEVELS The amount of lighting in the workplace affects quality and quantity of output and can affect overall wellbeing of occupants. Improper illumination levels can result in poor performance and health effects including headache and eyestrain. 74

ILLUMINATION MEASUREMENTS LIGHT METERS Light meters use a photo diode that converts incident light into an electrical signal. Readings are displayed on the meter in either lux or footcandles. SKC 753-003 75

DATA INTERPRETATION ILLUMINATION LEVELS The Illuminating Engineering Society of North America publishes guidelines for office and industrial lighting as the ANSI Secretariat. Their publications are available from SKC: Office (SKC 877-612) Industrial (SKC 877-611) 76

BUILDING COMFORT PARAMETERS Improper control of physical parameters can result in adverse health effects that mimic chemical exposures. Physical parameters include: Temperature Relative Humidity Air Movement Ventilation (Carbon Dioxide) 77

INDIVIDUAL PARAMETERS USING ELECTRONIC MONITORS CARBON DIOXIDE Direct-reading monitors with non-dispersive infrared (NDIR) sensors can typically measure CO 2 levels up to several thousand ppm without the need for frequent calibration. SKC Cat. No. 751-535 78

MULTIPLE PARAMETERS USING ELECTRONIC MONITORS QUEST EVM-7 MEASUREMENT OPTIONS: VOCs using PID Toxic gases CO 2 Relative humidity and temperature Air velocity (with probe) Particulates SKC 755-EVM-7 79

DATA INTERPRETATION BUILDING COMFORT PARAMETERS IAQA INDOOR AIR GUIDELINES Temperature in Summer: 73-79 F Temperature in Winter: 68-74.5 F Relative Humidity: 30-65% Air Movement: 0.8 ft/s or 0.25 m/s 80

DATA INTERPRETATION BUILDING COMFORT PARAMETERS IAQA INDOOR AIR GUIDELINES Ventilation (as Carbon Dioxide)-650 ppm over ambient 81

THANK YOU FOR YOUR ATTENTION! If you have additional questions, please Email skctech@skcinc.com www.skcinc.com I am the first responder to these Emails. 82

WHO DAT FINISHED TALKIN BOUT AIR SAMPLING 83