A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

A. Section includes surface preparation and application of wood finishes[.]

Union County Vocational - Technical Schools Scotch Plains, New Jersey

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

MDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls

RD COATINGS -RD-ELASTOFLEX ELASTOMERIC ACRYLIC WALL COATING SPECIFICATION

80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

SECTION (09941) - TEXTURED FINISHING

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

Section COATING RESTORATION

80648R StoCoat Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

A. Section includes surface preparation and the application of paint systems on interior substrates.

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

ZONE 7 WATER AGENCY CWS 5 TURNOUT REPLACEMENT PROJECT # ADDENDUM NO. 3 April 02, 2019

Section COATING RESTORATION

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 09 - FINISHES

Acrylitex Interior Texture and Coating Submittal Documentation

80201 StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

SKIMM /DUROFLOAT A High Performance Filling Compound For Interior Walls DST301. SKIMM / DUROFLOAT Specifications

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

Technical Data Sheet

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

SECTION DRY ERASE COATING (IdeaPaint CREATE Black and White) A. Section Gypsum Board Assemblies; gypsum board substrate.

SPECIFIER SHALL REMOVE COMMENTS IN BOLD TEXT PRIOR TO SUBMITTING.

Technical Data Sheet

1/16 Single Broadcast Polymer Flooring System

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

80230 StoColor Coat Sand Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING

SECTION PENETRATION FIRESTOPPING PART 1- GENERAL PART 2- PRODUCTS 1.1 RELATED DOCUMENTS

Dist. by: BEST MATERIALS Ph:

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

Acrylitex Tilt UP Primer Guide Specification Revised August 1, 2008

DAYTONA BEACH PIER BUILDING RESTORATION 06/10

ARDEX GUIDE SPECIFICATION ARDEX GPS GENERAL PATCH & SKIMCOAT Trowelable underlayment

Interior Painting Artesi II & III Day Care Facilities at 777 & 333 W. Matthews Road

SECTION INTUMESCENT FIREPROOFING

RESINOUS FLOORING

ARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors

SECTION MULTICOLOR INTERIOR FINISHING

A BRIEF HISTORY OF SPRAYSTONE

Union County Vocational - Technical Schools Scotch Plains, New Jersey

80648 StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

SECTION JOINT SEALERS 1.03 THIS SECTION INCLUDES JOINT SEALERS FOR THE FOLLOWING LOCATIONS:

80657 StoColor Texture - Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION INTUMESCENT MASTIC FIREPROOFING

SECTION HIGH PERFORMANCE COATINGS Ramuc Type EP Epoxy Updated October 5, 2015

FLUID APPLIED WATERPROOFING SECTION SPECIALTY COATINGS

KOSTER AMERICAN CORPORATION

VengerElectrostatic Coatings Master Specification Page 1

SECTION CONCRETE AND MASONRY COATINGS

CSI SECTION MAINTENANCE OF CONCRETE Repair & Resurfacing with Rapid Hardening, High Strength, Low-Shrink, Non-Metallic Cementitious Materials

SECTION PAINTING Ultra Premium

Note: Delete any section below not relevant to this project; add others as required.

ARDEX GUIDE SPECIFICATION ARDEX FEATHER FINISH Self-Drying, Cement-Based Finish Underlayment

Copyright 2002 AIA MASTERSPEC 05/02

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

Broadcast Parking Garage System

Complementary Coatings Insl-x. Stix Bonding Primer Introduction

1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats.

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

ROOF REPLACEMENT AND ALTERATIONS TO WOODSTOCK Barrett Architecture, PC WASTE WATER TREATMENT FACILITY - Woodstock, VT February 28, 2019 SECTION

FLEXMAR 3-Coat High-Build Colored Quartz System

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

SECTION EPOXY TERRAZZO

Specifications. Specifications (Architectual) Metallic System. Metallic System

Rust-Oleum Industrial Brands Specification

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

SECTION Arisfor WallGuard

SECTION RESINOUS FLOORING

INSTALLATION GUIDE SPECIFICATION

SECTION HYDRAULIC CEMENT UNDERLAYMENT

ARDEX GUIDE SPECIFICATION ARDEX K 22 F High Flow, Fiber Reinforced, Self-Leveling Underlayment

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

A. This specification describes the sealing of vertical joints/cracks with a one-component, gungrade, elastomeric sealants. B.

Application Specification:

SECTION HYDRAULIC CEMENT UNDERLAYMENT

Venger Electrostatic Coatings Master Specification Page 1

Florock Seamless Flooring Systems

A. This Section includes resinous flooring systems with epoxy body coat(s).

POLYURETHANE FOAM SAMPLE DESIGN GUIDELINE ACRYLIC

There are many surface contaminants that can interfere with coating adhesion. The following are the most common:

Application Specification:

SECTION RESILIENT TILE FLOORING. A. Section includes vinyl composition floor tile and accessories indicated and as specified.

Ger-Eck, LLC SCRIBIL Dry Erase Clear Coat Section July 12, 2013 SECTION SCRIBIL Dry Erase Clear Coat

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

SIDER-POOL. Product Data. Features and Uses

Florock Seamless Flooring Systems

ARDEX GUIDE SPECIFICATION ARDEX SD-M Designer Floor Finish

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

Transcription:

SECTION 099650 ARCHITECTURAL COATINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section includes surface preparation and application of architectural coating systems on the following substrates: 1. Metal. 2. Brick. 3. Concrete and masonry. 4. Ceiling Tiles. 5. Fiberglass. 6. Gypsum board. 7. Vinyl. 8. Glass. 9. Tile. 10. Plastic. 11. Wood. 12. Previously painted surfaces. 1.3 ACTION SUBMITTALS A. Product Data: For each type of product indicated. Include preparation requirements and application instructions. B. Samples for Initial Selection: For each type of topcoat product indicated. C. Samples for Verification: For each type of coating system and in each color and gloss of topcoat indicated. 1. Samples to be prepared and submitted to Contractor by approved installer. 2. Submit Samples on rigid backing, 8 inches square. 3. Step coats on Samples to show each coat required for system. 4. Label each coat of each Sample. 5. Label each Sample for location and application area. D. Product List: For each product indicated, include the following: ARCHITECTURAL COATINGS 099650-1

1. Cross-reference to paint system and locations of application areas. Use same designations indicated on Drawings and in schedules. 2. VOC content. 1.4 MAINTENANCE MATERIAL SUBMITTALS A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. 1. Coatings: 5 percent, but not less than 1 gal of each material and color applied. 1.5 QUALITY ASSURANCE A. Installer Qualifications: A qualified installer who employs workers who are trained by coating system manufacturer for installation techniques required. B. Mockups: Apply mockups of each coating system indicated to verify preliminary selections made under sample submittals and to demonstrate aesthetic effects and set quality standards for materials and execution. 1. Architect will select one surface to represent surfaces and conditions for application of each coating system specified in Part 3. a. Wall and Ceiling Surfaces: Provide samples of at least 100 sq. ft. b. Other Items: Architect will designate items or areas required. 2. Simulate finished lighting conditions for review of mockups. 3. Final approval of color selections will be based on mockups. a. If preliminary color selections are not approved, apply additional mockups of additional colors selected by Architect at no added cost to Owner. 4. Approval of mockups does not constitute approval of deviations from the Contract Documents contained in mockups unless Architect specifically approves such deviations in writing. C. Samples shall be made by company doing the installation in accordance with Contractors requirements. D. Each installation is solely the responsibility of the Dealer. E., Inc. assumes no responsibility for on-site inspections or application of its products. 1.6 DELIVERY, STORAGE, AND HANDLING A. Store materials not in use in tightly covered containers in well-ventilated areas with ambient temperatures continuously maintained at not less than 45 deg F. ARCHITECTURAL COATINGS 099650-2

1. Maintain containers in clean condition, free of foreign materials and residue. 2. Remove rags and waste from storage areas daily. 1.7 FIELD CONDITIONS A. Apply coatings only when temperature of product, surfaces to be coated, and surrounding air temperatures are above 45 deg F and surface temperature is at least 5 deg F above the dew point. For optimum application properties, bring material to at least 50 deg F. B. Air and surface temperatures must remain above 45 deg F for the next 24 hours. C. Avoid exterior application late in the day when dew and condensation are likely to form or if rain or snow is expected. D. Lighting: Do not install interior coating systems until a permanent level of lighting, or a lighting level that simulates the finished lighting, is provided on surfaces to receive coating systems. 1.8 WARRANTY A. Warranty: Manufacturer's standard form in which manufacturer warrants that the SprayStone Coating materials shall be free from the following defects within specified warranty period. 1. Defects defined as: a. Loss of bond, peeling, flaking, blistering, and weathering to expose underlying substrate. 2. Warranty Period: 5 years from date of Substantial Completion. 3. Conditions: a. Warranty will apply provided that SprayStone is applied to a suitable substrate that has been properly prepared and primed. b. Installation must be performed by a SprayStone Factory Trained Applicator. PART 2 - PRODUCTS 2.1 ARCHITECTURAL COATINGS A. Exterior/interior factory pre-mixed single component paint, 100 percent acrylic, LOW VOC, environmentally friendly, conventional pressure-feed spray applied, and a cost effective alternative to real granite. 1. Manufacturer: Subject to compliance with requirements, provide the following: a. Spray Stone USA, Inc.; SprayStone GT Series Top Coat. 2. Colors: As selected by Architect from manufacturer's full range. ARCHITECTURAL COATINGS 099650-3

B. Performance Test Data: 1. Surface-Burning Characteristics: Comply with ASTM E 84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. a. Flame-Spread Index: 25 or less (Class A). b. Smoke-Developed Index: 10 or less (Class A). 2. Adhesion: According to ASTM D 3359. a. No loss of Adhesion between primer and SprayStone GT. b. No loss of Adhesion between SprayStone GT and clear sealer. 3. Yellowness Evaluation: According to ASTM E 313 using ASTM D 4587 UV Test Method. a. Initial yellowness Index: 6.89. b. Post UV Weathering Yellowness Index: 6.42. 4. Flexural Strength: No Cracking (Pre- and Post- 1000 hour UV testing) according to ASTM D 522 Mandrel Bend Test. 5. Tensile Strength: According to ASTM D 2370. a. Pre UV Weathering: 212 psi (average). b. Post UV Weathering: 540 psi (average). 6. Water-Vapor Permeance: 20.124 perms (average) according to ASTM E 96. 7. Water-Vapor Transmission: 121.8 g/(day m 2 ) according to ASTM E 96. 2.2 MIXING A. SprayStone GT Series is mixed by slow pouring from clean bucket to bucket a minimum of two times (2X) and a maximum of four times (4X) until the required consistency is reached. B. SprayStone OP (Outer Phase) may be required if container has been opened 7 days or more, or if the SprayStone Coating in an unopened bucket had been produced more than 2 months prior to it being opened, SprayStone OP should be added at a ratio of 5 percent maximum / per remaining SprayStone GT material, to get to the recommended consistency. 2.3 APPLICATION EQUIPMENT A. SprayStone GT must be applied using conventional spray equipment, including a pressurized paint tank*, an air compressor operating at 5.0 SCFM at 90psi with air and fluid hoses, and a pressure-feed spray gun with a 2.5 mm fluid tip. 1. *NOTE: professional spray equipment may cause harm; therefore manufacturer s instructions should be followed at all times. ARCHITECTURAL COATINGS 099650-4

2.4 AUXILIARY MATERIALS A. Substrate Primer: Compatible with substrate and recommended or approved by architectural coating manufacturer. B. Elastomeric Coating: Compatible with surface primer and recommended or approved by architectural coating manufacturer. C. Clear Sealer: Compatible with topcoat and recommended or approved by architectural coating manufacturer. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with Applicator present, for compliance with requirements for maximum moisture content, surface conditions, compatibility with existing finishes and primers, and other conditions affecting performance of the Work. B. Proceed with coating application only after unsatisfactory conditions have been corrected. 1. Beginning coating application constitutes Contractor's acceptance of substrates and conditions. 3.2 PREPARATION A. Comply with manufacturer's written instructions and recommendations applicable to substrates indicated. B. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting. 1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection. C. Surfaces to be coated must be dry, clean, sound, and free from all contamination including loose and peeling paint, dirt, grease, oil, wax, concrete curing agents and bond breakers, chalk, efflorescence, mildew, rust, product fines, and dust. Remove loose paint, chalk, and efflorescence by wire brushing, scraping, sanding, and/or pressure washing. Putty all nail holes and caulk all cracks and open seams. Sand all glossy, rough, and patched surfaces. Feather back all rough edges to sound surface by sanding. Prime all bare and porous substrates. D. Clean surfaces per ASTM D 4258: Standard Practice for Surface Cleaning Concrete for Coating. Vacuum cleaning, water cleaning, detergent water wash, power wash cleaning, steam cleaning, hand tool and mechanical cleaning are acceptable cleaning methods. Remove efflorescence by pressure washing or cleaning with dilute muriatic acid (following ARCHITECTURAL COATINGS 099650-5

manufacturer s instruction) or a solution of 1 part white vinegar to 4 parts water. Rinse thoroughly and allow to dry. E. Remove mildew by using a solution of 1 part chlorine bleach to 3 parts water. Before use, be sure to read and follow instructions and warnings on label. F. Dry substrate thoroughly to a moisture content under 12 percent. Clean chalky paint in good condition by sweep blasting, power washing, wire brushing, etc. to remove loose material. After cleaning, powdery or chalky, unpainted recommended substrates may be conditioned with a surface sealer. G. Brick: New brick and mortar should cure for at least 7 days and preferably 30 days prior to priming and painting. The ph of the substrate must be less than 13 before priming with this alkali resistant primer. Painting glazed brick is not recommended due to potential adhesion problems. H. Concrete And Masonry: For optimum performance, all new masonry, concrete, and stucco construction should cure for at least 7 days and preferably 30 days prior to priming and painting. The ph of the substrate must be less than 13 before priming with an alkali-resistant primer, and moisture content should be below 12 percent. Fill holes and cracks with an appropriate filler if a smoother uniform surface is desired. Surfaces previously coated with water thinned cement-based paint must be prepared with extra care. A masonry sealer may be applied to seal the surface. Check adhesion by applying a piece of masking tape. If the sealer peels off and has loose particles, remove all chalking or crumbling material, reseal and re-check adhesion. I. Aluminum: This substrate may present potential adhesion problems. Any coating applied directly to aluminum should be spot applied, allowed to cure overnight, and then evaluated for adhesion. If adhesion is good, the application may proceed. Check adhesion by applying a piece of masking tape. When the masking tape is removed, if the coating peels off, the surface must be scuff sanded prior to proceeding to ensure mechanical adhesion. J. Ferrous Metal: The surface must be cleaned thoroughly to remove any dust, rust, and surface contaminants, and then primed with an appropriate primer for metal. K. Galvanized Steel: Caution must be used when selecting coatings for use on all galvanized metal surfaces. These substrates may have a factory-applied stabilizer, which is used to prevent white rusting during storage and shipping. Such stabilizers must be removed by either brush blasting, sanding or chemical treatment prior to priming with an appropriate primer for metal. L. Wood: Unpainted wood or wood in poor condition should be sanded smooth, wiped clean, and then primed with an appropriate primer. Any knots or resinous areas must be primed before painting. Countersink all nails, putty flush with surface, then prime. M. Gypsum Wallboard-Drywall: Nails or screws should be countersunk, and they along with any indentations should be mudded flush with the surface, sanded smooth and cleaned to remove any dust, then prime prior to painting the substrate. ARCHITECTURAL COATINGS 099650-6

3.3 APPLICATION A. Select an appropriate primer for the chosen surface and apply according to manufacturer s instructions. Allow to dry. B. Once primer has dried (refer to manufacturer s instructions), apply an elastomeric coating (if specified by the Architect). Allow to dry. C. Apply SprayStone with the pressure-feed spray gun. Hold the gun 18-30 inches from the surface and spray in smooth, even back-and-forth movements. Use steady, horizontal strokes and apply a light coat, allowing for about an 80 percent coverage. Some substrate should still be visible at this point. Do not over apply SprayStone as it will inhibit proper drying. D. Allow the 1st coat to dry for a minimum of 4 hours, depending on atmospheric conditions, and apply the second coat, this time using vertical strokes. You should now achieve 100 percent coverage and substrate should not be visible. The finished coat has to be visually even and homogeneous, with no bald spots or leaks. E. Allow 2nd coat to dry for a minimum of 4 hours, depending on atmospheric conditions. Drying times may vary with temperature, humidity and other environmental factors. F. Once the 2nd coat is completely dry, apply a thin, even layer of clear top coat according to manufacturer s instructions. G. For detailed installation instructions, please contact the Manufacturer. 3.4 CLEANING AND PROTECTION A. At end of each workday, remove rubbish, empty cans, rags, and other discarded materials from Project site. B. After completing coating application, clean spattered surfaces. Remove spattered coatings by washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces. C. Protect work of other trades against damage from coating operation. Correct damage by cleaning, repairing, replacing, and recoating, as approved by Architect, and leave in an undamaged condition. D. At completion of construction activities of other trades, touch up and restore damaged or defaced coated surfaces. 3.5 MAINTENANCE A. Clean with a liquid or powdered laundry detergent (without bleach) in a normal solution of one cup to five gallons of water. Agitate with a soft bristled brush as needed. B. For resealing or other maintenance, please contact the Manufacturer. ARCHITECTURAL COATINGS 099650-7

3.6 EXTERIOR FIVE COAT SYSTEM A. Prepare surface as per Primer manufacturer s recommendations. B. 1 Coat recommended Surface Primer (per manufacturer s recommendations). C. 1 Coat Elastomeric Coating (per manufacturer for product and color recommendations). D. 1 Coat SprayStone GT series ~80 percent coverage. E. 1 Coat SprayStone GT series 100 percent coverage. F. 1 Coat recommended Clear Top Coat Sealer (Flat or Satin sheen) (per manufacturer s product recommendations). 3.7 INTERIOR THREE COAT SYSTEM A. Prepare surface as per Primer manufacturer s recommendations. B. 1 Coat recommended Surface Primer (per manufacturer s recommendations). C. 1 Coat SprayStone GT series ~80 percent coverage. D. 1 Coat SprayStone GT series 100 percent coverage. END OF SECTION DISCLAIMER SprayStone products must be installed in accordance with the manufacturer s current, published specifications, product instructions, and installation procedures. Each installation is solely the responsibility of the Installer. The architecture, design and engineering of a project using SprayStone products are the responsibilities of the project s design professional. A SprayStone coating can be installed as the exterior coating on a wall assembly approved and constructed pursuant to all applicable code requirements for that structure. The applicator must consult the applicable code requirements for the jurisdiction in which the construction is commencing, not only to the application of SprayStone, but also to the substrate upon which it is applied. Failure to adhere to those code requirements by the applicator could render the application deficient and nullify SprayStone product warranty from, Inc., Inc. will warrant the performance of a properly installed SprayStone coating as defined in, Inc. s published 5 Year Limited Warranty documents. Please contact, Inc., for additional information. ARCHITECTURAL COATINGS 099650-8