LEED TM Post-Occupancy Evaluation: Taking Responsibility for the Occupants

Similar documents
David and Lucile Packard Foundation

Assessment of Indoor Climate: Learning from Buildings

Using Segmentation Strategies to Create Targeted Climate Change Messaging for Office Workers

in UFAD Systems The control of room-air stratification is Design Guidelines for Stratification

Implications IN THIS ISSUE. A Newsletter by InformeDesign. A Web site for design and human behavior research.

UC Berkeley Indoor Environmental Quality (IEQ)

Satisfaction and self-estimated performance in relation to indoor environmental parameters and building features

WBC Occupant Comfort Survey

Thermal Comfort Research at the Center for the Built Environment

Center for the Built Environment CBE. An Industry/University Research Collaboration University of California, Berkeley.

LEED LEED LEED. Earth Tech, Inc. Earth Tech, Inc. A Firm With Experience. A Firm With Experience. Operational Efficiencies & Resources Preservation

LEED And Your Indoor Environment

Thermal, Visual and Energy Performance in LEED buildings: Two Case Studies

LEED Summary Window Treatment Coverings LEED v4 for BD+C: New Construction

THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS

Satisfying more while consuming less--

What is Green Building?

Innovations in Acoustical Ceilings for Today's Flexible Interiors

Architecture and Acoustic Design in Green Buildings

centerlinewinter Newsletter of the Center for the Built Environment at the University of California, Berkeley

Genentech Building 20 Office LEED-CI Gold XL CONSTRUCTION

Post-occupancy Evaluation of Green Buildings Are they as green as we thought? Guy Newsham, Ph.D. and colleagues

UC Berkeley HVAC Systems

LEED v4: the program

University of Wisconsin La Crosse Centennial Hall LEED Credit 7.2 Thermal Comfort Plan

What occupants really think about comfort in the buildings they work in, and why it matters

LEED v4 Building Design and Construction Quiz #8 EQ

INDDOR ENVIRONMENTAL QUALITY

You Can t Afford Discomfort. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Chapter 8: Indoor Environmental Quality

LEED Saving energy with Copaco sunscreens. COPACO LEED

Assessment of Indoor Environments

Green Building Rating System

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

WELCOME. Page 1. WELCOME to the Building Environmental Comfort Verification Survey.

LEED -Existing Buildings. Crescent Ridge Corporate Center I

Armstrong World Industries CAMPUS CORPORATE HEADQUARTERS BUILDING 701

Built to Succeed: Sustainable Learning Environment at UC Merced Library. Haipeng Li University of California, Merced June 2016

Building Operator Certification Level I

THE ECONOMICS OF LEED FOR EXISTING BUILDINGS FOR INDIVIDUAL BUILDINGS 2008 EDITION A WHITE PAPER APRIL 21, 2008

Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

LEED Certified Health Center

Building Typology Draft Metrics

An Introduction to the LEED TM Green Building Rating System

UC Berkeley Indoor Environmental Quality (IEQ)

Cleveland Clinic. Center for Functional Medicine

Paul Ehrlich, PE Ira Goldschmidt, PE

THE HUMAN FACTORS OF SUSTAINABLE BUILDING DESIGN: POST OCCUPANCY EVALUATION OF THE PHILIP MERRILL ENVIRONMENTAL CENTER, ANNAPOLIS, MD

A Building Commissioning Overview. Presented by: Goetting & Associates Commissioning

Indoor Thermal Environmental Control and Satisfaction: Advanced HVAC systems and occupant satisfaction and comfort

1. Select the group that best represents your connection with Eagle Hall.

LEED. Leadership in Energy and Environmental Design

California State University, Sacramento February 24, 2010

Tracking LEED Performance Metrics at Old Dominion University s Engineering & Computational Sciences Research Laboratory

A COMPARATIVE ANALYSIS OF LEED CHRISTINE LIN

CASE STUDIES OF A METHOD FOR PREDICTING SPEECH PRIVACY IN THE CONTEMPORARY WORKPLACE. Designing Acoustically Successful Workplaces:

Findings of Field Survey for Thermal Comfort and Ventilation in US Office Buildings

500 WEST PUTNAM AVENUE GREENWICH, CT

Indoor Environmental Quality + Workplace Environment Rochester Community and Technical College: Workforce Center Colocation (RCTC-WCC)

HPBS [ HIGH PERFORMANCE BUILDING STANDARD]

centerlinewinter 2010

Energy Harvesting Technologies for Buildings. Cory Vanderpool Business Development Director, North America

BUILDING PERFORMANCE MEASUREMENT PROTOCOLS and THEIR APPLICATION ASHRAE Triangle Chapter September 10, 2014 Raleigh, NC

The central atrium acts as a thermal chimney that drives natural ventilation flow in the building

MEP Engineer's Letter of Assurance

HELPING HVAC PROFESSIONALS TAKE THE LEED ACHIEVING LEED CERTIFICATION

23-28 = -5. Zero Net Energy Case Study WEST BERKELEY PUBLIC LIBRARY OVERVIEW. Planning & Design Approach. Measured Energy Stats

LEED Best Practices Save $$$

Thermal Comfort & Green Buildings. Dr. Ommid Saberi. "Green Retrofit Conference. WSP Environment & Energy (Middle East)

Center for the Built Environment UC Berkeley

Implementing Lighting Management Technologies and Practices to Drive Building Efficiency. NEMA Enlighten America 2011

NBI Getting to Zero National Forum: A Presentation by Clark Brockman, SERA Architects September 17, 2013

60 79 points 80 points and above. A complete explanation of the LEED credit weightings system is available on the USGBC website, at

Mind the Gaps: Post-Occupancy Discoveries from Design to Operation

LEED 2009 for Commercial Interiors. Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP

Blue Ridge Parkway Destination Center Earns a Rare 11 of 10 Points for Optimized Energy Performance

S-Lab: Laboratory for Sustainable Business Spring 2008

UC Berkeley Indoor Environmental Quality (IEQ)

Light Control and LEED

ENGINEERING UPDATE WHITE PAPER: BUILDING PERFORMANCE METRICS. price-hvac.com. May 2013 Vol. 10

EVER GREEN: A POST-OCCUPANCY BUILDING PERFORMANCE ANALYSIS OF LEED CERTIFIED HOMES IN NEW ENGLAND

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

ENGINEERING. Edition No. 20 April 2004

Improving Thermal Comfort & Reducing Energy Consumption in Naturally Ventilated University Buildings

Understanding LEED for Homes v4

Engaging Occupants in Green Building Performance: Addressing the Knowledge Gap

The USGBC booklet, LEED for Existing Buildings: Operations

Rob Samish, AIA, LEED AP. Architect, Lionakis CHPS Board Member

MEP's Letter of Assurance

Co-working Spaces: Designing For Profits and Health. PureLiving & naked HUB

Eaton Center - Shanghai LEED CI Certification Project

RRCI Reflective Roof Coatings & LEED Webinar Presentation. Speakers Bill Kirn & Robert Kobet

CONTENTS. 71 Section 01352, #7 (Life Cycle Cost and Life Cycle Assessment) 2/1/12 Modified entire section 72 Section 01352, #8 (Sustainability

LEED-CI ANALYSIS 115 STEVENS AVENUE VALHALLA, NY

Smart Building Facilitated by Wireless Sensor Networks and Integrated Terminal Control

USGBC & LEED. A Summary of the LEED Development as a primer for LEED ND

2010 CA Higher Education Sustainability Conference

LEED for Commercial Interiors

Research Analysis: Building Envelope and LEED Credits Introduction

All the Design Elements We Cannot See

Transcription:

LEED TM Post-Occupancy Evaluation: Taking Responsibility for the Occupants David Lehrer CBE Director of Communications Better Bricks, USGBC/CGBC Cascadia Chapter Portland, November 1 2006 Seattle, November 2 2006 CENTER FOR THE BUILT ENVIRONMENT UC BERKELEY Today s talk About the Center for the Built Environment (CBE) Tour of the Occupant Indoor Environmental Quality (IEQ) Satisfaction Survey Recent analysis and findings Acoustics Thermal comfort and air quality LEED IEQ Case studies Examples of POE studies using the survey Update on LEED and surveys Wrap-up & discussion Center for the Built Environment (CBE) 1

Center for the Built Environment (CBE) Our Mission: To improve the design, operation, and environmental quality of buildings by providing timely, unbiased information on building technologies and design techniques CBE Industry Partners Armstrong World Industries Arup* California Energy Commission Charles M. Salter Associates CPP Inc. Flack + Kurtz HOK Pacific Gas & Electric Co. Price Industries RTKL Skidmore Owings and Merrill Stantec Steelcase Syska Hennessy Group Tate Access Floors* Taylor Engineering Team: Taylor Engineering CTG Energetics Guttmann & Blaevoet Southland Industries Swinerton Builders Trane U.S. Department of Energy (DOE)* U.S. General Services Administration (GSA)* Webcor* York International Corporation *founding partner Center for the Built Environment (CBE) 2

CBE research programs Indoor Environmental Quality Envelope and Facade Systems HVAC Systems Controls and Information Technology CBE feedback loop Finding ways to take the pulse of buildings in operation Helping industry to make better buildlings Center for the Built Environment (CBE) 3

LEED Post-Occupancy Evaluation: Post occupancy evaluation (POE) process POEs rarely done by design teams POEs may include: Surveys of building occupants Observations and/or interviews with building users Performance in terms of energy and/or water consumption Physical measurements (temperature, humidity, acoustical, lighting, daylighting) When to do a POE Part of commissioning plan 6 months Post commissioning at least 12 months Center for the Built Environment (CBE) 4

Occupant IEQ survey Standardized methodology for studying building performance from occupants point of view Provide feedback to building designers, owners, and operators Helps us understand how buildings perform in practice Web format is inexpensive, fast, allows for branching questionos, automatic reporting, data mining Results can be used for: Diagnostics Benchmarking Survey history late 80 s ASHRAE Thermal Comfort Studies early 90 s Johnson Controls Tablet-based survey LAN-based survey mid 90 s 1999 First Web-based Survey Research projects evaluating effectiveness of various building attributes U.S. General Services Administration Developed current core survey, and special-purpose modules Center for the Built Environment (CBE) 5

Usability testing UCB Survey Research Center Focus groups Cognitive interviewing Assessed Comprehension of survey wording Scale size and aesthetics Survey length Core survey now highly standardized for accurate benchmarking Survey implementation Survey notification via email Occupants respond to web-based survey Data sent to SQL server database Results reported online Center for the Built Environment (CBE) 6

Survey welcome page Objective information Center for the Built Environment (CBE) 7

Typical survey page Drill-down questions Satisfaction Scale Next survey topic Branched to a follow-up page with probing questions regarding nature of dissatisfaction Center for the Built Environment (CBE) 8

Typical follow-up page Core survey Background Location Office Layout Office Layout Office Furnishings Office Furnishings Thermal Comfort Thermal Comfort Air Quality Air Quality Lighting Acoustics Clean/Maint General Comments Center for the Built Environment (CBE) 9

Custom modules Background Location Office Layout Office Layout Office Furnishings Office Furnishings Thermal Comfort Thermal Comfort Air Quality Air Quality Lighting Acoustics Clean/Maint. Wayfinding Commute Restrooms Safety/Security etc General Comments Custom modules Accessibility Building and Grounds Maintenance Service Commute Conference and Training Rooms Court Work Daylighting Laboratories Office Support Equipment Operable Windows Raised Floor and Floor Diffusers Restrooms Safety and Security Wayfinding Center for the Built Environment (CBE) 10

Automated reporting Diagnosing problems Center for the Built Environment (CBE) 11

Survey database growth To date: 290+ buildings, nearly 39,000+ respondents # building in database (Cumulative) 350 300 250 200 150 100 50 0 2001 2002 2003 2004 2005 2006 2007 Years Collecting building characteristics Excerpt from building profile form Center for the Built Environment (CBE) 12

Survey data mining tool IEQ satisfaction trends Source: CBE survey database as of April 15, 2006 Center for the Built Environment (CBE) 13

Acoustics analysis Acoustic Quality in Office Workstations, as Assessed by Occupant Surveys, Jensen, K., E. Arens, and L. Zagreus, 2005 Proceedings, Indoor Air 2005, Sept. 4-9, Beijing, China. Studied satisfaction with acoustics in office environments Acoustical satisfaction lowest category Analyzed data from 142 buildings 23,450 occupants Sound privacy vs. noise level Overall Database Average Category Scores 3 Mean Satisfaction Score 2 1 0-1 -2-3 Ofc Layout Ofc Furn Therm Air Q Light Acoust Clean Gen Wspce Gen Bldg Largest 15 CBE Bldgs (N=4096) Noise Level Sound Privacy Survey Category Center for the Built Environment (CBE) 14

Acoustic average satisfaction score Acoustic quality impact on productivity Center for the Built Environment (CBE) 15

Top sources of dissatisfaction Of those expressing dissatisfaction with acoustics Rank Source of dissatisfaction Private office Shared office Cubicles with high partitions Cubicles with low partitions 1 People talking on the phone 21% 50% 70% 83% 2 People overhearing private conversations 25% 40% 65% 71% 3 People talking in surrounding offices 15% 21% 45% 54% 4 People talking in the corridor 6% 12% 25% 27% 5 Telephones ringing 2.5% 8% 23% 31% 6 Office equipment 4% 5% 13% 14% Key findings Over 50% of occupants in cubicles think acoustics interfere with their ability to get their job done Acoustic satisfaction will not be improved much by making cubicles higher Occupants in open office more satisfied with acoustics than occupants in cubicles Of the 9 core survey categories, acoustics causes the greatest dissatisfaction Center for the Built Environment (CBE) 16

Potential solutions Acoustical consideration during design, using consultants or Speech Privacy Predictor (SPP) Focus on improving conditions for cube-dwellers Sound masking, improved sound absorption Lower telephone ringing volume, visual ring Provide varied workspace options Thermal comfort and air quality analysis Air Quality and Thermal Comfort in Office Buildings: Results of a Large Indoor Environmental Quality Survey, Huizenga, C., S. Abbaszadeh, L. Zagreus and E. Arens, 2006. Proceedings, Healthy Buildings 2006, June 4-8, Lisbon, Vol. III, 393-397. Studied satisfaction with thermal comfort, air quality, compared to existing standards Analyzed data from 215 buildings 34,169 occupants Center for the Built Environment (CBE) 17

Thermal comfort & air quality standards Standards define acceptable indoor environment: Conditions in which more than 80% of people do not express dissatisfaction ASHRAE Standard 55-2004 (Thermal comfort) ASHRAE Standard 62.1-2004 (Air quality) And others even more restrictive! (90% threshold) ISO Standard 7730:1994 (Thermal comfort) Top 3 (>0): satisfied Top 4 (>=0): not dissatisfied (CBE satisfaction threshold) (acceptability standard) Thermal satisfaction: 2 nd lowest category How satisfied are you with the temperature in your workspace? Number of respsonses 10,000 8,000 19% 6,000 14%13% 15% 16% 16% 4,000 6% 2,000 - -3-2 -1 0 1 2 3 very dissatisfied very satisfied Overall: 42% of respondents dissatisfied Center for the Built Environment (CBE) 18

Distribution of thermal satisfaction 11% of buildings meet acceptability standard Number of buildingsx 60 50 40 30 20 10 0 14% 15% 24% 21% 15% 9% 1% 1% 0-9% 10-19% 20-29% 30-39% 40-49% 50-50% 60-69% 70-79% 80-89% 90-99% 100% Percent satisfied Percent satisfied: Top 4 points (>=0) on 7-point satisfaction scale Sources of thermal discomfort Source of dissatisfaction with temperature in CBE survey database (one-person/one-vote) (total number of complaints = 32,806) My area is hotter/colder than other area Thermostat is inaccessible Thermostat is adjusted by other people Air movement too low Heating/cooling system does not respond Drafts from vents Air movement too high Incoming sun Other Humidity too high (damp) Hot/cold surrounding surfaces (floor, ce Humidity too low (dry) Drafts from windows Heat from office equipment Air coming out of vents too hot/cold Clothing policy is not flexible Heating/cooling capacity is insufficient 5% 5% 5% 4% 3% 3% 3% 3% 2% 1% 1% 7% 14% 13% 13% 11% 9% 0% 5% 10% 15% % of total thermal dissatisfaction votes Center for the Built Environment (CBE) 19

Thermal controls & satisfaction Personal control over environmental conditions has a positive impact on occupant satisfaction All occupants No thermostat Thermostat Difference % satisfied* 58% 56% 76% 20% N 32,749 29,313 3,437 No operable window 57% 30,018 Operable window 67% 2,732 Personal devices that compensate for building conditions can indicate dissatisfaction Difference No portable heater Portable heater Difference No portable fan 10% 59% 44% -15% 60% 29,435 3,315 25,422 Portable fan 51% 7,328 Difference -9% *(>=0 on the 3 to +3 satisfaction scale) (p<0.01) Air quality satisfaction: 3 rd lowest category How satisfied are you with the air quality in your workspace (i.e. stuffy/stale air, cleanliness, odors)? Number of respsonses 10,000 8,000 23% 18% 19% 6,000 13% 4,000 9% 10% 8% 2,000 - -3-2 -1 0 1 2 3 very dissatisfied very satisfied Among those who were dissatisfied with their air quality, major complaints were (in order): Air is stuffy/stale 74% Air is not clean 67% Air is smelling bad 51% Overall: 32% of respondents dissatisfied Center for the Built Environment (CBE) 20

Distribution of air quality satisfaction 26% of buildings meet acceptability standard Number of buildingsx 60 50 40 30 20 10 0 1% 1% 8% 19% 20% 25% 15% 9% 2% 0-9% 10-19% 20-29% 30-39% 40-49% 50-50% 60-69% 70-79% 80-89% 90-99% 100% Percent satisfied Percent satisfied: Top 4 points (>=0) on 7-point satisfaction scale LEED IEQ analysis Occupant Satisfaction with Indoor Environmental Quality in Green Buildings. Abbaszadeh Fard, S., L. Zagreus, D. Lehrer and C. Huizenga, 2006. Proceedings, Healthy Buildings 2006, June 4-8, Lisbon, Vol. III, 365-370. Compared occupant satisfaction in 21 green or LEEDcertified buildings with 160 non-green buildings Analyzed data from 181 buildings 33,285 occupants Center for the Built Environment (CBE) 21

What is Green Design? Design and construction practices that significantly reduce or eliminate the negative impact of buildings on the environment and occupants in five broad areas: Sustainable site planning Safeguarding water and water efficiency Energy efficiency and renewable energy Conservation of materials and resources Indoor environmental quality Source: Introduction to USGBC and LEED Green Rating System, 3/18/2004 Research opportunity: LEED IEQ analysis Do LEED-rated / green buildings in fact have better indoor environmental quality? Center for the Built Environment (CBE) 22

LEED-rated / green buildings in database 15 LEED-rated and 6 selfnominated buildings 160 other buildings in CBE database Chesapeake Bay Foundation Chicago Center for Green Technology NC 2 platinum NC 2 gold NC 2 silver NC 2.1 NC 2 certified NC 1 platinum EB pilot CI pilot 1 2 3 2 1 2 1 3 JohnsonDiversey Global Headquarters NC=New Construction; EB=Existing Buildings; CI=Commercial Interiors Self-nominated green buildings 6 buildings identified by building design team or owner: 2 received national AIA Top 10 Green Building Awards 2 received Environmental Design & Construction awards 1 received Savings by Design award 1 received local awards Carnegie Center for Global Ecology National Wildlife Federation World Resources Institute Center for the Built Environment (CBE) 23

Categories in LEED NC 2.1 & EB 2.0 LEED - NC LEED - EB Sustainable Sites 14 14 Water Efficiency 5 5 Energy & Atmosphere 17 23 Materials & Resources 13 16 Indoor Environmental Quality 15 22 Innovation & Design Process 5 5 Total 69 85 % of IEQ credit points 22% 26% Mapping survey categories to LEED Survey Satisfaction categories Office Layout Office Furnishing Thermal Comfort Air Air Quality Lighting LEED IEQ credit categories Thermal comfort Air Air Quality Daylight & views Controllability of of systems Acoustics Cleaning & Maint. Gen. Bldg Bldg & Workspace Center for the Built Environment (CBE) 24

IEQ in LEED-rated/green buildings paper (n=21) (n=160) Source: CBE survey database as of September 27, 2005 Percentile charts overview Very satisfied Overall Satisfaction - Building CBE Database, buildings with responses >15 (n=161) 3 Mean Satisfaction Score 0 Median 1.07 161 buildings Un-weighted average: 1 bldg. = 1 vote Approx. 28,000 occupant responses Average response rate 49% Median entire database -3 8000% 25% 50% 75% 100% 600 Very 400 Percentile Rank dissatisfied 200 0 Center for the Built Environment (CBE) 25

Building overall: satisfaction 3 Overall Satisfaction - Building LEED-rated/green (n=21) Compared to CBE Database (n=160) Mean Satisfaction Score 0 1.47 0.93 Median of rest of database Median of LEEDrated/green buildings -3 0% 25% 50% 75% 100% Percentile Rank Database building LEED-rated building Green building Thermal Comfort: satisfaction Overall Satisfaction - Thermal Comfort LEED-rated/green (n=21) Compared to CBE Database (n=160) Mean Satisfaction Score 3 0 0.36-0.16 Median of rest of database Median of LEEDrated/green -3 0% 25% 50% 75% 100% Percentile Rank Database building LEED-rated building Green building Center for the Built Environment (CBE) 26

Air Quality: satisfaction Overall Satisfaction - Air Quality LEED-rated/green (n=21) Compared to CBE Database (n=160) Mean Satisfaction Score 3 0 1.14 0.21 Median of rest of database Median of LEEDrated / green buildings -3 0% 25% 50% 75% 100% Percentile Rank Database building LEED-rated building Green building Lighting: satisfaction 3 Overall Satisfaction - Lighting LEED-rated/green (n=21) Compared to CBE Database (n=160) Mean Satisfaction Score 0 1.12 1.08 Median of rest of database Median of LEEDrated / green buildings -3 0% 25% 50% 75% 100% Percentile Rank Database building LEED-rated building Green building Center for the Built Environment (CBE) 27

Lighting complaints Average lighting complaints in LEED-rated/green buildings (n=21) and the rest of CBE database (n=160) not enough daylight Reflections in the computer screen too dark too bright no task lighting Not enough electric lighting Too much electric lighting Electric lighting is an undesirable color Shadows on the workspace Electric lighting flickers Other: too much daylight No control over sunlight/daylight Database building 0% 20% 40% 60% 80% 100% LEED-rated/green building Lighting dissatisfaction comments Building A task lights don t work the only light is above the light shelf, I had to bring in my own lamp.. Building B Too bright in some places, too dark in others, and not enough task lighting The light sensors need to be adjusted to come on sooner. Task light mounted on wrong side of workstation. Building C The lighting in my cube was woefully inadequate from day one. The task lighting does not shine where I do my reading and writing. Another light lights the space behind my computer monitor and over my telephone Center for the Built Environment (CBE) 28

Lighting controls Average lighting controls in LEED-rated/green buildings (n=21) and the rest of CBE database (n=160) Desk (task) light Light switch Window blinds or shades None of the above Other: Light dimmer 0% 20% 40% 60% 80% 100% Database building LEED-rated/green building Sustainable design strategies Lighting Common strategies include Provide lower levels of ambient electric lighting Rely more on daylight to conserve energy and enhance IEQ Can result in Thermal discomfort Glare/reflections Workspace too dark/bright Lessons learned Provide effective controls to occupants such as task lighting, blinds and shades Commission automated systems such as occupancy/daylight sensors and shading systems Center for the Built Environment (CBE) 29

Acoustics: satisfaction Overall Satisfaction - Acoustics LEED-rated/green (n=21) Compared to CBE Database (n=160) 3 Mean Satisfaction Score 0-0.20-0.27 Median of rest of database Median of LEEDrated / green buildings -3 0% 25% 50% 75% 100% Percentile Rank Database building LEED-rated building Green building Acoustic complaints Average acoustic complaints in LEED-rated/green buildings (n=21) and the rest of CBE database (n=160) People talking in neighboring areas People overhearing my private conversations People talking on the phone telephones ringing Mechanical (heating, cooling and ventilation systems) noise Office equipment noise outdoor traffic noise Other: people in corridor Office lighting noise Excessive echoing of voices or other sounds Database building 0% 20% 40% 60% 80% 100% LEED-rated/green building Center for the Built Environment (CBE) 30

Office type Average distribution of office types in LEED-rated/green buildings (n=21) and the rest of CBE database (n=160) Cubicles with low partitions (lower than five feet high) Cubicles with high partitions (about five or more feet high) Enclosed office, private Workspace in open office with no partitions (just desks) Other: Enclosed office, shared with other people Cubicles with partitions of different heights 0% 20% 40% 60% 80% 100% Database building LEED-rated/green building Acoustics dissatisfaction comments Building A (96% open office, n=703) Desks too close everyone can hear everything. Even a tiny sneeze. You can hear noises emanating 20 to 25 feet away. There is no sound deadening effect from the cubicle walls and the floor always sounds like a herd of elephants is doing a ballet. Building B (97% open office, n=173) obnoxious neighbors who think they are the only ones on the block. No one can ever hear my radio even though I think it's turned up loud. I'm a loud talker and I'm sure I disturb other people Center for the Built Environment (CBE) 31

Conclusions: LEED IEQ analysis LEED-rated / green buildings had significantly higher satisfaction scores in: building overall indoor air quality thermal comfort LEED-rated / green buildings did not have higher scores in: lighting acoustics No clear relationship found between LEED credit points and occupant satisfaction with IEQ LEED rating by itself does not guarantee better IEQ Case studies Very satisfied 3 Overall Satisfaction - Building LEED & GREEN (n=20) Compared to CBE Database (n=161) Chesapeake Chesapeake Bay Bay Foundation Foundation Mean Satisfaction Score 0 Johnson Johnson Diversey Diversey Carnegie Carnegie Center Center -3 0% 25% 50% 75% 100% Very Percentile Rank dissatisfied LEED-certified bldg. Self-nominated green bldg. Non-green bldg. Center for the Built Environment (CBE) 32

Case study: Chesapeake Bay Foundation First LEED-certified Platinum (version 1.0), completed in 2001 5 of 7 possible IEQ points (36 of 52 total possible points) Numerous sustainable features DOE-sponsored field study conducted by Judith Heerwagen, used extended version of occupant survey, interviews and observations Heerwagen, J. and L. Zagreus, The Human Factors of Sustainability: A Post Occupancy Evaluation of the Philip Merrill Environmental Center. April 2005 Case study: Chesapeake Bay Foundation Center for the Built Environment (CBE) 33

Case study: Carnegie Center for Global Ecology Stanford campus, Palo Alto, CA Clients understood green building priorities, did not rely on LEED Selected design team with extensive green building experience Designed to beat California energy code by 57% IEQ features include daylighting, radiant heating and cooling, natural ventilation with operable windows Case study: Carnegie Center for Global Ecology High marks overall Acoustical score puts building in top quartile 83% in open office, no partitions Center for the Built Environment (CBE) 34

Case study: JohnsonDiversey Survey client: JohnsonDiversey 2 buildings surveyed One LEED-EB certified The other not LEED certified Core survey plus washrooms and security modules JohnsonDiversey Headquarters LEED-EB pilot (gold) JohnsonDiversey survey results Certified building performed significantly better than the non-certified building in nearly every category Non LEED certified building LEED certified building Center for the Built Environment (CBE) 35

JohnsonDiversey survey results, cont d Operational applications resulting from the study Certified building Continue IAQ and other management programs Non-certified building Instituted new cleaning and lighting programs to align with LEED standard Plans improvements to HVAC, lighting and acoustics Both buildings Numerous low hanging fruit fixes Comments a rich source of information POE Applications: HOK HOK Process 1. CBE occupant satisfaction survey 2. Energy evaluation 3. Interviews Customized survey questions Solar control Automated lighting controls Occupancy sensors Building recycling program 9 buildings included Images: HOK Center for the Built Environment (CBE) 36

POE Applications: HOK Source: Sandra Mendler, AIA, HOK POE Applications: HOK Summary of POEs identified: Workplace Conservation of resources Placemaking & values What s working Room for improvement Occupant comments: There s not a day that goes by that I take these working conditions for granted... I feel like a rat in a cage,... Otherwise everything s fine. Thank you for asking my opinion. Source: Sandra Mendler, AIA, HOK Center for the Built Environment (CBE) 37

HOK POE outcomes Disseminated findings in guidebook Presentations to AIA membership, Green building confessions Motivate industry to conduct POEs Assist design of future projects Fosters closer relationship with clients Raise awareness of need to focus on issues like daylighting Study anticipated vs. actual energy use Show importance of building commissioning Southwestern B.C. study Detailed studies of five green buildings in SW British Columbia Led by Greater Vancouver Regional District, Green Buildings BC, and Stantec (Keen) Completed Nov. 2004 Project led to the development of building performance evaluation (BPE) protocol now in development with Stantec and the EcoSmart Foundation Center for the Built Environment (CBE) 38

Southwestern B.C. study Source: Stantec LEED NC 2.2 updates thermal comfort credits Previous version LEED NC 2.1 Credit 7.1 (Comply w/ ASHRAE 55-1992) Credit 7.2 (Permanent monitoring system) New version LEED NC 2.2 (November 2005) Credit 7.1 (Comply w/ ASHRAE 55-2004) Credit 7.2 (Verification) Center for the Built Environment (CBE) 39

IEQ Credit 7.2 Thermal Comfort: Verification Agree to implement a thermal comfort survey of building occupants within a period of six to 18 months after occupancy. This survey should collect anonymous responses about thermal comfort in the building including an assessment of overall satisfaction with thermal performance and identification of thermal comfort-related problems. Agree to develop a plan for corrective action if the survey results indicate that more than 20% of occupants are dissatisfied Additional resources CBE Publications Page: http://www.cbe.berkeley.edu/research/publications.htm Environmental Building News, Volume 12, Number 9, September 2003 (available free from BuildingGreen.com) Federal Facilities Council, Technical Report 145, Learning from our buildings: a state-of-the-practice summary of post-occupancy evaluation (2001) Mendler, S., W. Odell, M. A. Lazarus The HOK Guidebook to Sustainable Design (2006) Center for the Built Environment (CBE) 40

Questions/discussion David Lehrer lehrer@berkeley.edu Survey demo http://www.cbesurvey.org Center for the Built Environment http://www.cbe.berkeley.edu Survey researcher wanted! http://www.cbe.berkeley.edu/jobs Center for the Built Environment (CBE) 41